• Title/Summary/Keyword: Decreasing function

Search Result 865, Processing Time 0.028 seconds

The Efficacy of Fluorograb for Paediatric Patients Dose Reduction during Pneumatic Reduction and Voiding Cystourethrography(VCUG) (영.유아의 배뇨성 방광-요도 조영술 및 방사선 공기 주입 정복술시 피폭선량 경감을 위한 fluorograb의 유용성)

  • Kim, Sang-Tae;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.385-390
    • /
    • 2009
  • The Pneumatic Reduction and VCUG (Voiding Cystourethrography) are commonly used in the paediatric age group. The procedures had a particularly long fluroscopic screening time, despite a successful outcome for paediatric patients. Pneumatic Reduction and VCUG almost invariably requires fluoroscopic guidance which does confer a radiation dose. This article contains suggestions on how the radiation dose to paediatric patients from Pneumatic Reduction and VCUG can be made "as low as reasonably achievable" (ALARA). The aim of our study was eliminated in spot image applying the FluoroGrab, which has function of capturing an image of interest area from the picturing while fluoroscopic procedures. FluoroGrab has clinical value equivalent to the spot image, and is applied to the most recent fluoroscopic procedures. The radiologist and the radiographers should consider new option for decreasing the radiation exposure delivered to paediatric patients by making equipment modifications to the fluoroscopy to optimize radiation exposure reduction techniques. Thus, we propose the FluoroGrab instead of spot exposure for the reduction of patient exposure dose in paediatric, and try to confirm the effect of the mitigating amount of radiation exposure to paediatric patients when pneumatic reduction and VCUG. Fluorograb is the safe and useful method that shows the equivalent level of accuracy to spot exposure, and to minimize the radiation load to paediatric patients are to be the substitute for the spot exposure for Pneumatic Reduction and VCUG.

New VLSI Architecture of Parallel Multiplier-Accumulator Based on Radix-2 Modified Booth Algorithm (Radix-2 MBA 기반 병렬 MAC의 VLSI 구조)

  • Seo, Young-Ho;Kim, Dong-Wook
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.4
    • /
    • pp.94-104
    • /
    • 2008
  • In this paper, we propose a new architecture of multiplier-and-accumulator (MAC) for high speed multiplication and accumulation arithmetic. By combining multiplication with accumulation and devising a hybrid type of carry save adder (CSA), the performance was improved. Since the accumulator which has the largest delay in MAC was removed and its function was included into CSA, the overall performance becomes to be elevated. The proposed CSA tree uses 1's complement-based radix-2 modified booth algorithm (MBA) and has the modified array for the sign extension in order to increase the bit density of operands. The CSA propagates the carries by the least significant bits of the partial products and generates the least significant bits in advance for decreasing the number of the input bits of the final adder. Also, the proposed MAC accumulates the intermediate results in the type of sum and carry bits not the output of the final adder for improving the performance by optimizing the efficiency of pipeline scheme. The proposed architecture was synthesized with $250{\mu}m,\;180{\mu}m,\;130{\mu}m$ and 90nm standard CMOS library after designing it. We analyzed the results such as hardware resource, delay, and pipeline which are based on the theoretical and experimental estimation. We used Sakurai's alpha power low for the delay modeling. The proposed MAC has the superior properties to the standard design in many ways and its performance is twice as much than the previous research in the similar clock frequency.

A Clinical Analysis of Surgically Managed Thyroid Nodule (외과적으로 치료한 갑상선 결절에 대한 임상적 고찰)

  • Jung In-Kyu;Kim Lee-Su;Choi Won-Jin
    • Korean Journal of Head & Neck Oncology
    • /
    • v.9 no.1
    • /
    • pp.16-24
    • /
    • 1993
  • During 7 years, from Jan. 1986 to Dec. 1992, authors studied 208 cases of the surgically managed thyroid nodules at the Department of General Surgery, Han Kang Sacred Heart Hospital and obtained the following results. 1) Among the total 208 cases, male to female ratio was 1:11.2 in benign thyroid diseases and 1:9 in malignant thyroid diseases. The benign disease was prevalent between second and forth decade comparing with malignant disease between third and fifth decade. 2) The most common duration of illness was 3 months(26.0%). 3) Palpable neck mass was the most common chief complaint(100%). Palpitation. fatigue, and sweating were common complaints in patient with benign disease, and fatigue, palpitation, and sweating in malignant disease in decreasing order of frequency. 4) 55.8 % of lesions were in right lobe, 33.2% in left lobe, 5.8% in diffuse type, 4.8% in bilateral lobes, and 0.5% in isthmus. 5) The most common size of nodule was between 2.0cm and 3.9cm in diameter, which consisted of 55.1% of benign disease and 48.0% of malignant disease. 6) 86.5% of thyroid function test showed euthyroidism, 10.1% hyperthyroidism, and 3.4% hypothyroidism. 7) Thyroid scanning of 176 patients revealed cold nodules in 92.5% of benign diseases and in 92.9% of malignant diseases. 8) The most common benign disease was adenomatous hyperplasia(62.7%), and the most common malignant disease was papillary adenocarcinoma(80.0%). 9) Fine needle aspiration cytology was performed in 91 cases, and it showed 69.0% of sensitivity, 90.3% of specificity, and 83.5% of accuracy. 10) Frozen biopsy was performed in 109 cases. and it showed 93.9% of sensitivity, 100.0% of specificity, and 98.2% of accuracy. 11) The most commonly performed operation was unilateral lobectomy(including unilateral lobectomy with isthmectomy)(79.1%) in benign disease. and total thyroidectomy(62.0%) in malignant disease. 12) Postoperative complication showed 5 cases of wound infection (2.4%), 3 cases of transient hypoparathyroidism(1.4%), 3 cases of transient hoarseness(1.4%), 2 cases of postoperative bleeding(1.0%), 1 case of permanent hypoparathyroidism(0.5%), 1 case of permanent hoarseness(0.5%), and 1 case of postoperative pneumonia (0.5%).

  • PDF

Changes in the Blood Components Caused by Water Intake (물 섭취에 의한 혈액 성분 변화에 관한 연구)

  • Kim, Hyun-Kyung;Kim, Soo-Hwan;Ryu, Jae-Ki
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.3
    • /
    • pp.227-232
    • /
    • 2017
  • Although water is an essential component of the human body and is involved in many physiological processes, the effect of a steady and sufficient water intake on blood components has not well elucidated. Therefore, we investigated the changes in hematological parameters, high-sensitivity C-reactive protein (hs-CRP), and immunoglobulin G (IgG) after water intake in 13 healthy adults. They were divided into two groups: The control group (N=4), which consumed water ad libitum, and the experimental group (N=9), which consumed 2 L of water per day. Two weeks later, blood cell counts, hematocrit, and hemoglobin content had increased in the experimental group, although not significantly (p>0.05); however, there was a significant increase in the mean corpuscular hemoglobin (MCH) and mean corpuscular hemoglobin concentration (MCHC) (p<0.05; and p<0.01, respectively), and a significant decrease in the mean platelet volume (MPV) (p<0.05). Of the immunologic parameters, a non-significant decrease in the concentration of hs-CRP, an indicator of cardiovascular disease risk, was observed (p>0.05). However, there was a dramatic and significant increase in the concentration of IgG (p<0.05). In conclusion, a steady and sufficient water intake may contribute to alleviate anemia by increasing hemoglobin. Additionally, it may decrease the risk of cardiovascular disease by decreasing platelet activation and concentration of hs-CRP. Furthermore, a steady intake of water may improve immune function by increasing the concentration of the components of humoral immunity.

Design of an Automatic Winch System for Small Fishing Vessel (소형 어선의 자동 권양 윈치시스템 설계)

  • 이대재;김진건;김병삼
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.3
    • /
    • pp.157-165
    • /
    • 2000
  • A small hydraulic winch system with an automatic tension control unit was designed to improve the work efficiency of coastal small vessels and the dynamic response characteristics of the winch system operated in the open loop condition was investigated. The inlet and the outlet pressures in hydraulic motor, the torque and the rotating speed of winch drum were measured as a function of time, and the behaviour in autotension mode for stepped load changes was analyzed. The results obtained are summarized as follows : 1. The developed winch system for coastal small vessels will result in better fishing with improved efficiency and lower manpower consumption by remote control of winch system. 2. The rotating delay times of winch drum for on/off operations of solenoid valve were 0.09 see at CW mode and 0.04 sec at CCW mode, respectively. After the solenoid valve was controlled, response characteristics were unstable slightly but showed good tracking behaviour over short time. 3. The driving torque of winch system in autotension mode was kept almost constant of 55.9 kgf·m, and 11.1 then the rotating speed of winch drum was kept almost constant of 5.1 rpm in the larger torque than 55.9 kgf·m and 11.1 rpm in the lower torque than that. 4. The 5% settling times in the transient response characteristics of autotension mode under rapid increasing and decreasing conditions of load were 0.12 sec and 0.2 sec, respectively, and then the rotating speeds were 11 rpm and 5.3 rpm, respectively. 5. The tracking behaviour of torque and rotating speed by remote control operation were stable within 0.23 sec at CW mode and 0.37 sec at CCW mode, respectively.

  • PDF

The Effects of Kinetics on the Leaching Behavior of Heavy Metals in Tailings-Water Interaction (광미-물 상호반응에서 반응시간이 중금속 용출에 미치는 영향)

  • Kang Min-Ju;Lee Pyeong-Koo;Kim Sang-Yeon
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.1
    • /
    • pp.23-36
    • /
    • 2006
  • Experimental leaching of tailings was performed as a function of times (1, 2, 4, 7, 14, 21 and 30 days) in the laboratory using reaction solutions equilibrated to three different pH set-points (pHs 1,3 and 5). The initial pHs of 5 and 3 stabilized at either 4.6-6.1 or 2.8-3.5 in 2 days and decrease gradually with time afterwards. The results of the leaching tests indicate that the significant increase in the sulfate concentrations and in acidity after 7 days of leaching results from the oxidation of sulfide minerals. There were no significant variations in the extractable Pb found in the leach solutions of pH 5 and 3 within the reaction time (1-30 days), while Zn, Cd and Cu concentrations tend to significantly increase with time. In tailings leaching at an initial pH=1, two trends were observed: i) The 'Zn-type' (Zn, Cd and Cu), with increasing concentrations between days 1 and 30, corresponding to the expected trend when continuous dissolution is the dominant process, ii) the 'Pb-type' (Pb), with decreasing concentrations over time, suggesting rapid dissolution of a Pb source followed by the precipitation of 'anglesite' in relation to the large increase in dissolved sulfates. The high sulfate concentrations were coupled with high concentrations of released Fe, Zn and Cd. Release of Zn and Cd and acidity from these leaching experiments can potentially pose adverse impact to surface and groundwater qualities in the surrounding environment. The kinetic problems could be the important factor which leads to increasing concentrations of trace metals in the runoff water.

Impacts Analysis of the operation of DVR(Driving Video Recorder) on Driver's Behavior Change and Reduction of Traffic Accident (교통사고 영상기록장치(DVR : Driving Video Recorder)의 설치가 운전자의 운전태도 변화와 교통사고 저감에 미치는 효과 분석)

  • Jang, Seok-Yong;Jeong, Heon-Yeong;Baek, Sang-Geun;Go, Sang-Seon
    • Journal of Korean Society of Transportation
    • /
    • v.27 no.3
    • /
    • pp.119-130
    • /
    • 2009
  • The aim of this study is to analyze the effects of DVR(Driving Video Recorder) operation on decreasing the number of traffic accidents, the cost of traffic accident claim, and the behavioral change in drivers' driving. The data for this research are obtained from taxi drivers in Busan. For this, Structural Equation Model and two-way ANOVA are employed for empirical analysis. Overall results of this study show that the number of traffic accidents of 4 taxi corporations in Busan has decreased by average 32.7 percent after using DVRs. In addition, as to the cost of taxi accident claims, it is expected that the DVR operation has a considerable effect on economic benefits of taxi corporations. Moreover, this study could make clear the difference in behaviors between DVR users and non-users, and discriminate the positive and negative impacts of the DVR operation on the drivers' driving behavior. The study quantitatively examined the indirect impact of 'attitude', 'subject norm' and 'behavioral control' factors on planned 'behavior', and the direct impact of 'behavioral control' factor on the planned 'behavior'. This study suggests that they should add the video recoding function of DVRs when operation recorder(blackbox for the car) is obligatorily set up on cars for business by traffic security law.

'Studies on diagnosis and Treatment of tumor.abscess.ulcer in intestinal carbuncle' (장옹(腸癰)에 있어서 종양(腫瘍).농양(膿瘍).궤양(潰瘍)의 진단(診斷)과 치료(治療)에 관(關)한 고찰(考察))

  • Han, Gyu-Eon;Ryu, Bong-Ha;Park, Dong-Won;Ryu, Gi-Won;Jang, In-Gyu
    • The Journal of Internal Korean Medicine
    • /
    • v.11 no.1
    • /
    • pp.93-107
    • /
    • 1990
  • Studies on diagnosis and treatment of tumor . abscess . ulcer in intestinal carbuncle were carried out. The result of studies were summerized as follows: 1. By Nai-Gyung carbuncle-tumor arose from disharmony between nutrient and defensive because of cold, abscess arose from fever victory between cold and fever, ulcer arose from decreasing function of Bi-Kam year. By latter literature Bi-Kam year could be interpreted that spleen stomach was invaded evil influence from unattainable vital force of the earth. 2. Sites of intestinal carbuncle were large intestine, small intestine, intestinal inside or outside between large and small intestine, Intestinal carbuncle was common name of a disease about large intestinal carbuncle, small intestinal carbuncle, pelvic intestinal carbuncle, shrink leg intestinal carbuncle etc.. Pain appeared Chunchu-Hyul in large intestinal carbuncle, and Gwanweon-Hyul in small intestinal carbuncle. 3. On abdominal diagnosis tumor had indistinct pain of Gwanweon Chunchu, edema and heary feeling in low abdomen, no excessive pain by hand press and intestinal boiling sound. In abscess pain descended from right side of low abdomen to huckle, and there was rejection against press, feeling about fever,water sound with flank movement. In ulcer hand approach was difficult since excessive pain diffuse to whole abdomen, and perforating ulcer sometimes caused a serious symptom of umbilical pus. 4. On fecal and urinary diagnosis in tumor urine was yellowish red pollakiuria like gonorrhoea and occasional constipation. In abscess uncomfortable rough pain short red early urine like gonorrhoea appeared during urination, and constipation with stinging pain appeared during defecation. In ulcer red rough pyuria appeared, and stinging and pain with puruloid blood appeared during defecation. 5. On treatment in tumor Daiwhang-Tang Daisenggi-Tang Dangui-Jun by dissipation method, calming down method, interior reliance maturation method, in abscess Mokdan-San Euiiin-Tang Jeokduiin-Tang by the method of water repelling pus discharge, acute breaking, in ulcer Takridanggui-Tang Paljin-Tang Bojungikki-Tang were each used by the method of interior reliance, virulence astriction, supplement vital force and blood, supplement spleen stomach. 6. On treatment patient may have to be careful of excessive moving and suprising anxiety. Abuse of acupuncture and moxibustion made patient worse, misuse of analgesics purgative intestinal irrigation etc. could provoke difficult diagnosis and perforation. So you must treat after exact diagnosis. 7. Prognosis of ease tumor ease abscess ease ulcer and ease astriction was good. If the intestinal carbuncle were not to promote to abscess and ulcer for a long time, its prognosis was bad and it could metastasize to cancer because of dark purple with hardness. So tumor abscess ulcer in intestinal carbuncle may be significant of precancerous lesion.

  • PDF

Synthesis and Densification Behavior of Al Doped (La0.8Ca0.2)(Cr0.9Co0.1)O3(LCCC) Ceramics for SOFC Interconnects (SOFC 연결재용 Al이 도핑된 (La0.8Ca0.2)(Cr0.9Co0.1)O3(LCCC)계 세라믹스의 합성 및 치밀화 특성)

  • Lee, Ho-Young;Kang, Bo-Kyung;Lee, Ho-Chang;Heo, Young-Woo;Kim, Jeong-Joo;Kim, Jae-Yuk;Lee, Joon-Hyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.5
    • /
    • pp.392-397
    • /
    • 2012
  • In the $(La_{0.8}Ca_{0.2})(Cr_{0.9}Co_{0.1})O_3$ (LCCC), which has been using as interconnector materials in SOFC, Al ions were substituted for Co because ionic radius of Al is similar to that of Co. Because of the almost identical ionic radius of Al and Co, the substitution was not thought to be affect the tolerance factor of LCCC, and the densification behavior, high temperature electrical conductivity and thermal expansion coefficient were examined as a function of Al concentration. In the cases of the x= 0 and x= 0.02 in $(La_{0.8}Ca_{0.2})(Cr_{0.9}Co_{0.1-x}Al_x)O_3$ (x= 0~0.1), the samples showed the relative densities above ${\geq}95%$ when those were sintered at ${\geq}1,350^{\circ}C$. In the case of the $x{\geq}0.06$ the sintered density deteriorated greatly at lower sintering temperatures. High temperature electrical conductivity of the samples decreased as the content of Al increased. Since the valence state of Al ion is unchangeable, while Cr or Co ions contribute to the electrical conduction by changing those valence states, Al substitution resulted in the decreased electrical conductivity. Al doping of LCCC was an effective way of decreasing the thermal expansion coefficient (TEC).

Physical Modeling of Chemical Exchange Saturation Transfer Imaging

  • Jahng, Geon-Ho;Oh, Jang-Hoon
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.135-143
    • /
    • 2017
  • Chemical Exchange Saturation Transfer (CEST) imaging is a method to detect solutes based on the chemical exchange of mobile protons with water. The solute protons exchange with three different patterns, which are fast, slow, and intermediate rates. The CEST contrast can be obtained from the exchangeable protons, which are hydroxyl protons, amine protons, and amide protons. The CEST MR imaging is useful to evaluate tumors, strokes, and other diseases. The purpose of this study is to review the mathematical model for CEST imaging and for measurement of the chemical exchange rate, and to measure the chemical exchange rate using a 3T MRI system on several amino acids. We reviewed the mathematical models for the proton exchange. Several physical models are proposed to demonstrate a two-pool, three-pool, and four-pool models. The CEST signals are also evaluated by taking account of the exchange rate, pH and the saturation efficiency. Although researchers have used most commonly in the calculation of CEST asymmetry, a quantitative analysis is also developed by using Lorentzian fitting. The chemical exchange rate was measured in the phantoms made of asparagine (Asn), glutamate (Glu), ${\gamma}-aminobutyric$ acid (GABA), glycine (Gly), and myoinositol (MI). The experiment was performed at a 3T human MRI system with three different acidity conditions (pH 5.6, 6.2, and 7.4) at a concentration of 50 mM. To identify the chemical exchange rate, the "lsqcurvefit" built-in function in MATLAB was used to fit the pseudo-first exchange rate model. The pseudo-first exchange rate of Asn and Gly was increased with decreasing acidity. In the case of GABA, the largest result was observed at pH 6.2. For Glu, the results at pH 5.6 and 6.2 did not show a significant difference, and the results at pH 7.4 were almost zero. For MI, there was no significant difference at pH 5.6 or 7.4, however, the results at pH 6.2 were smaller than at the other pH values. For the experiment at 3T, we were only able to apply 1 s as the maximum saturation duration due to the limitations of the MRI system. The measurement of the chemical exchange rate was limited in a clinical 3T MRI system because of a hardware limitation.