• Title/Summary/Keyword: Decay rate

Search Result 603, Processing Time 0.026 seconds

CORE THERMAL HYDRAULIC BEHAVIOR DURING THE REFLOOD PHASE OF COLD-LEG LBLOCA EXPERIMENTS USING THE ATLAS TEST FACILITY

  • Cho, Seok;Park, Hyun-Sik;Choi, Ki-Yong;Kang, Kyoung-Ho;Baek, Won-Pil;Kim, Yeon-Sik
    • Nuclear Engineering and Technology
    • /
    • v.41 no.10
    • /
    • pp.1263-1274
    • /
    • 2009
  • Several experimental tests to simulate a reflood phase of a cold-leg LBLOCA of the APR1400 have been performed using the ATLAS facility. This paper describes the related experimental results with respect to the thermal-hydraulic behavior in the core and the system-core interactions during the reflood phase of the cold-leg LBLOCA conditions. The present descriptions will be focused on the LB-CL-09, LB-CL-11, LB-CL-14, and LB-CL-15 tests performed using the ATLAS. The LB-CL-09 is an integral effect test with conservative boundary condition; the LB-CL-11 and -14 are integral effect tests with realistic boundary conditions, and the LB-CL-15 is a separated effect test. The objectives of these tests are to investigate the thermal-hydraulic behavior during an entire reflood phase and to provide reliable experimental data for validating the LBLOCA analysis methodology for the APR1400. The initial and boundary conditions were obtained by applying scaling ratios to the MARS simulation results for the LBLOCA scenario of the APR1400. The ECC water flow rate from the safety injection tanks and the decay heat were simulated from the start of the reflood phase. The simulated core power was controlled to be 1.2 times that of the ANS-73 decay heat curve for LB-CL-09 and 1.02 times that of the ANS-79 decay curve for LB-CL-11, -14, and -15. The simulated ECC water flow rate from the high pressure safety injection pump was 0.32 kg/s. The present experimental data showed that the cladding temperature behavior is closely related to the collapsed water level in the core and the downcomer.

GLOBAL EXISTENCE AND ASYMPTOTIC BEHAVIOR OF A PLATE EQUATION WITH A CONSTANT DELAY TERM AND LOGARITHMIC NONLINEARITIES

  • Remil, Melouka
    • Communications of the Korean Mathematical Society
    • /
    • v.35 no.1
    • /
    • pp.321-338
    • /
    • 2020
  • In this paper, we investigate the viscoelastic plate equation with a constant delay term and logarithmic nonlinearities. Under some conditions, we will prove the global existence. Furthermore, we use weighted spaces to establish a general decay rate of solution.

Physiological properties of grape cluster portions between cultivars and the effect of postharvest cooling on the marketability (포도 품종간 송이 부위별 생리적 특성과 수확 후 냉각과 유통성 관계)

  • Min, Jeong-Ho;Lim, Byung-Seon;Choi, Yeon-Soo;Lee, Kyung-Min;Kim, Dal-Woo;Hwang, Yong-Soo
    • Korean Journal of Agricultural Science
    • /
    • v.39 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • Rapid loss of grape berry quality after harvest occurs due to poor postharvest management. Understanding physiological properties between cultivars is required to develop practical technologies to control fast quality deterioration of tables grapes. Physiological characteristics of whole cluster, rachis and berries were examined to find their effects on postharvest behaviour of table grapes. 'Tamnara' showed high respiration rate and browning of rachis compared to 'Campbell Early'. Weight loss of rachis of 'Cheongsoo' was highest of three cultivars. Berry decay in 'Cheongsoo' begins at the connection portion between peduncle and berry, and berry decay of 'Cheongsoo' was the most severe among three cultivars. Precooling at $0^{\circ}C$ showed better results than cooling at $10^{\circ}C$ regardless of cultivars but cooling effect decreased when simulated marketing period increased up to 10 days. Plastic film wrapping was effective on reducing decay in general but not at higher marketing temperature. For successful commercialization of newly developed grapes, the inhibition technology of rachis browning in 'Tamnara' is required and decay control in 'Cheongsoo' through establishment of cold chain system is recommended.

Evaluation of Chlorine Demand and Chlorine Decay Kinetics for Drinking Water (정수처리에서 염수요구량 및 반응거동에 관한 연구)

  • 이윤진;조관형;최종헌;명복태;남상호
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.1
    • /
    • pp.27-35
    • /
    • 2001
  • This aim of the work presented in this paper is to investigate the factors that affcet chlorine decay and to develop functional relationships that can be used to enhance the durability of network models. predictive relationships were established that correlated the rate of chlorine decay to the various water conditions such as DOC, N $H_3$-N, initial chlorine, contact time, temperature and pH values. Free chlorine residual decreased with increasing temperature, DOC, N $H_3$-N, reaction time and chlorine dose. At 2$0^{\circ}C$, pH 7, The initial chlorine demand per mg as DOC/L and mg as N $H_3$-N/L was about 0.43, 2.69 mg/$\ell$ respectively at 180 minutes contact time. The Reaction between chlorine and humic acids was lasted intil 48hr, but the reaction between chlorine and N $H_3$-N was almost completed in 180 min. When the temperature is raised by 1$0^{\circ}C$, chlorine is more consumed about 0.25 mg/$\ell$ in the absence of organic substances and it is more consumed about 3.4 mg/$\ell$ in the presence of humic acid (5 mg/$\ell$) in water at pH 7 for 180 min. Regression Analysis created the resulting prediction equation for the chlorine decay in a SPSS package of the computer system. The model is as follows; $C_{t}$=1.239+0.707(Co)-0.000529(Time)-0.0112(Temp)+0.02227(pH)-0.42(DOC)-2.132(N $H_3$-N).).

  • PDF

Critical Role of Glu175 on Stability and Folding of Bacterial Luciferase: Stopped-flow Fluorescence Study

  • Shirazy, Najmeh Hadizadeh;Ranjbar, Bijan;Hosseinkhani, Saman;Khalifeh, Khosrow;Madvar, Ali Riahi;Naderi-Manesh, Hossein
    • BMB Reports
    • /
    • v.40 no.4
    • /
    • pp.453-458
    • /
    • 2007
  • Bacterial luciferase is a heterodimeric enzyme, which catalyzes the light emission reaction, utilizing reduced FMN (FMNH2), a long chain aliphatic aldehyde and $O_2$, to produce green-blue light. This enzyme can be readily classed as slow or fast decay based on their rate of luminescence decay in a single turnover. Mutation of Glu175 in $\alpha$ subunit to Gly converted slow decay Xenorhabdus Luminescence luciferase to fast decay one. The following studies revealed that changing the luciferase flexibility and lake of Glu-flavin interactions are responsible for the unusual kinetic properties of mutant enzyme. Optical and thermodynamics studies have caused a decrease in free energy and anisotropy of mutant enzyme. Moreover, the role of Glu175 in transition state of folding pathway by use of stopped-flow fluorescence technique has been studied which suggesting that Glu175 is not involved in transition state of folding and appears as surface residue of the nucleus or as a member of one of a few alternative folding nuclei. These results suggest that mutation of Glu175 to Gly extended the structure of Xenorhabdus Luminescence luciferase, locally.

Effects of an ice pack and sulfur generating pad treatment for home delivery on the quality of 'Duke' blueberry fruits

  • Lim, Byung-Seon;Choi, Mi-Hee;Lee, Jin-Su
    • Korean Journal of Agricultural Science
    • /
    • v.45 no.4
    • /
    • pp.811-821
    • /
    • 2018
  • This study focused on the improvement of blueberry delivery service using pre-cooled ice and $SO_2$ pads to prevent an increase in the fruit temperature as well as decay. To maintain the fruit quality during low temperature storage, the effect of a $SO_2$ pad and modified atmosphere packaging was also examined. Harvested blueberries were precooled at $15^{\circ}C$, sorted, and packaged. And the fruits were placed in a similar environment as that for the parcel service. Part of the fruits were stored at $0^{\circ}C$ for long term storage. The air temperature in the delivery box increased along with an increase in the simulated delivery time regardless of the treatment. However, the rate of temperature increase was lower in the ice pad treatment. No significant difference was not found after 48 h. The oxygen concentration in the box ranged between 10.5 - 14.5% in the ice pad treatment, which was higher than that of the untreated control (7.5 - 11.9%) whereas the $CO_2$ concentration was lower in the ice pad treatment. No differences were found in the occurrence of off-flavor, decay, and sensory quality loss during the 48 hours of the parcel service simulation. The combined treatment of the $SO_2$ pad and modified atmosphere packaging (MAP) using a perforated film increased the shelf-life of the blueberry fruits, the overall quality such as firmness, and the soluble solid content was not different between the treatments except for the decay incidence. No decayed fruit was found in the combined treatment. However, the percentage of decayed fruit in the control was 25% on day 15 of storage and 75% on day 33 of storage, respectively.

The effects of activated cooler power on the transient pressure decay and helium mixing in the PANDA facility

  • Kapulla, R.;Paranjape, S.;Fehlmann, M.;Suter, S.;Doll, U.;Paladino, D.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2311-2320
    • /
    • 2022
  • The main outcomes of the experiments H2P6 performed in the thermal-hydraulics large-scale PANDA facility at PSI in the frame of the OECD/NEA HYMERES-2 project are presented in this article. The experiments of the H2P6 series consists of two PANDA tests characterized by the activation of three (H2P6_1) or one (H2P6_2) cooler(s) in an initially stratified and pressurized containment atmosphere. The initial stratification is defined by a helium-rich region located in the upper part of the vessel and a steam/air atmosphere in the lower part. The activation of the cooler(s) results i) in the condensation of the steam in the vicinity of the cooler(s), ii) the corresponding activation of large scale natural circulation currents in the vessel atmosphere, with the result of iii) the re-distribution and mixing of the Helium stratification initially located in the upper half of the vessel and iv) the continuous pressure decay. The initial helium layer represents hydrogen generated in a postulated severe accident. The main question to be answered by the experiments is whether or not the interaction of the different, localized cooler units would be important for the application of numerical methods. The paper describes the initial and boundary conditions and the experimental results of the H2P6 series with the suggestion of simple scaling laws for both experiments in terms of i) the temperature difference(s) across the cooler(s), ii) the transient steam and helium content and iii) the pressure decay in the vessel. The outcomes of this scaling indicate that the interaction between separate, closely localized units does not play a prominent role for the present experiments. It is therefore reasonable to model several units as one large component with equivalent heat transfer area and total water flow rate.