• 제목/요약/키워드: Debris extrusion

검색결과 15건 처리시간 0.02초

Effects of the endodontic access cavity on apical debris extrusion during root canal preparation using different single-file systems

  • Tufenkci, Pelin;Yilmaz, Koray;Adiguzel, Mehmet
    • Restorative Dentistry and Endodontics
    • /
    • 제45권3호
    • /
    • pp.33.1-33.10
    • /
    • 2020
  • Objectives: This study was conducted to evaluate the effects of traditional and contracted endodontic cavity (TEC and CEC) preparation with the use of Reciproc Blue (RPC B) and One Curve (OC) single-file systems on the amount of apical debris extrusion in mandibular first molar root canals. Materials and Methods: Eighty extracted mandibular first molar teeth were randomly assigned to 4 groups (n = 20) according to the endodontic access cavity shape and the single file system used for root canal preparation (reciprocating motion with the RCP B and rotary motion with the OC): TEC-RPC B, TEC-OC, CEC-RPC B, and CEC-OC. The apically extruded debris during preparation was collected in Eppendorf tubes. The amount of extruded debris was quantified by subtracting the weight of the empty tubes from the weight of the Eppendorf tubes containing the debris. Data were analyzed using 1-way analysis of variance with the Tukey post hoc test. The level of significance was set at p < 0.05. Results: The CEC-RPC B group showed more apical debris extrusion than the TEC-OC and CEC-OC groups (p < 0.05). There were no statistically significant differences in the amount of apical debris extrusion among the TEC-OC, CEC-OC, and TEC-RPC B groups. Conclusions: RPC B caused more apical debris extrusion in the CEC groups than did the OC single-file system. Therefore, it is suggested that the RPC B file should be used carefully in teeth with a CEC.

Shaping ability and apical debris extrusion after root canal preparation with rotary or reciprocating instruments: a micro-CT study

  • Emmanuel Joao Nogueira Leal da Silva;Sara Gomes de Moura;Carolina Oliveira de Lima;Ana Flavia Almeida Barbosa;Waleska Florentino Misael;Mariane Floriano Lopes Santos Lacerda;Luciana Moura Sassone
    • Restorative Dentistry and Endodontics
    • /
    • 제46권2호
    • /
    • pp.16.1-16.11
    • /
    • 2021
  • Objectives: The aim of this study was to evaluate the shaping ability of the TruShape and Reciproc Blue systems and the apical extrusion of debris after root canal instrumentation. The ProTaper Universal system was used as a reference for comparison. Materials and Methods: Thirty-three mandibular premolars with a single canal were scanned using micro-computed tomography and were matched into 3 groups (n = 11) according to the instrumentation system: TruShape, Reciproc Blue and ProTaper Universal. The teeth were accessed and mounted in an apparatus with agarose gel, which simulated apical resistance provided by the periapical tissue and enabled the collection of apically extruded debris. During root canal preparation, 2.5% sodium hypochlorite was used as an irrigant. The samples were scanned again after instrumentation. The percentage of unprepared area, removed dentin, and volume of apically extruded debris were analyzed. The data were analyzed using 1-way analysis of variance and the Tukey test for multiple comparisons at a 5% significance level. Results: No significant differences in the percentage of unprepared area were observed among the systems (p > 0.05). ProTaper Universal presented a higher percentage of dentin removal than the TruShape and Reciproc Blue systems (p < 0.05). The systems produced similar volumes of apically extruded debris (p > 0.05). Conclusions: All systems caused apically extruded debris, without any significant differences among them. TruShape, Reciproc Blue, and ProTaper Universal presented similar percentages of unprepared area after root canal instrumentation; however, ProTaper Universal was associated with higher dentin removal than the other systems.

Impact of root canal curvature and instrument type on the amount of extruded debris during retreatment

  • Burcu Serefoglu;Gozde Kandemir Demirci;Seniha Micoogullari Kurt;Ilknur Kasikci Bilgi;Mehmet Kemal Caliskan
    • Restorative Dentistry and Endodontics
    • /
    • 제46권1호
    • /
    • pp.5.1-5.13
    • /
    • 2021
  • Objectives: The aim of the current study was to assess whether the amount of extruded debris differs for straight and severely curved root canals during retreatment using H-files, R-Endo, Reciproc and ProTaper Universal Retreatment (PTU-R) files. Additionally, the area of residual filling material was evaluated. Materials and Methods: Severely curved (n = 104) and straight (n = 104) root canals of maxillary molar teeth were prepared with WaveOne Primary file and obturated with gutta-percha and AH Plus sealer. Root canal filling materials were removed with one of the preparation techniques: group 1: H-file; group 2: R-Endo; group 3: Reciproc; group 4: PTU-R (n = 26). The amount of extruded material and the area of the residual filling material was measured. The data were analyzed with 2-way analysis of variance (ANOVA) and 1-way ANOVA at the 0.05 significance level. Results: Except for Reciproc group (p > 0.05), PTU-R, R-Endo, and H-file systems extruded significantly more debris in severely curved canals (p < 0.05). Each file system caused more residual filling material in severely curved canals than in straight ones (p < 0.05). Conclusions: All instruments used in this study caused apical debris extrusion. Root canal curvature had an effect on extruded debris, except for Reciproc system. Clinicians should be aware that the difficult morphology of the severely curved root canals is a factor increasing the amount of extruded debris during the retreatment procedure.

Influence of size and insertion depth of irrigation needle on debris extrusion and sealer penetration

  • Uzunoglu-Ozyurek, Emel;Karaaslan, Hakan;Turker, Sevinc Aktemur;Ozcelik, Bahar
    • Restorative Dentistry and Endodontics
    • /
    • 제43권1호
    • /
    • pp.2.1-2.10
    • /
    • 2018
  • Objectives: To determine the effect of size and insertion depth of irrigation needle on the amount of apical extruded debris and the amount of penetration depth of sealer using a confocal laser scanning microscope (CLSM). Materials and Methods: Twenty maxillary premolars were assigned to 2 groups (n = 10), according to the size of needle tip, 28 G or 30 G. Buccal roots of samples were irrigated with respective needle type inserted 1 mm short of the working length (WL), while palatal roots were irrigated with respective needle type inserted 3 mm short of the WL. Prepared teeth were removed from the pre-weighed Eppendorf tubes. Canals were filled with F3 gutta-percha cone and rhodamine B dye-labeled AH 26 sealer. Teeth were transversally sectioned at 1 and 3 mm levels from the apex and observed under a CLSM. Eppendorf tubes were incubated to evaporate the irrigant and were weighed again. The difference between pre- and post-weights was calculated, and statistical evaluation was performed. Results: Inserting needles closer to the apex and using needles with wider diameters were associated with significantly more debris extrusion (p < 0.05). The position of needles and level of sections had statistically significant effects on sealer penetration depth (p < 0.05 for both). Conclusions: Following preparation, inserting narrower needles compatible with the final apical diameter of the prepared root canal at 3 mm short of WL during final irrigation might prevent debris extrusion and improve sealer penetration in the apical third.

Efficacy of reciprocating and rotary retreatment nickel-titanium file systems for removing filling materials with a complementary cleaning method in oval canals

  • Said Dhaimy;Hyeon-Cheol Kim;Lamyae Bedida;Imane Benkiran
    • Restorative Dentistry and Endodontics
    • /
    • 제46권1호
    • /
    • pp.13.1-13.9
    • /
    • 2021
  • Objectives: This study aimed to evaluate and compare the efficacy of the S1 reciprocating system and the D-Race retreatment rotary system for filling material removal and the apical extrusion of debris. Materials and Methods: Sixty-four freshly extracted maxillary canines were shaped with size 10 and size 15 K-files, instrumented using ProTaper Gold under irrigation with 2.5% sodium hypochlorite (NaOCl), obturated according to the principle of thermo-mechanical condensation with gutta-percha and zinc oxide eugenol sealer, and allowed to set for 3 weeks at 37℃. Subsequently, the teeth were divided into a control group (n = 4), the D-Race rotary instrument group (n = 30), and the S1 reciprocating instrument group (n = 30). After classical retreatment, the canals were subjected to a complementary approach with the XP-Endo Shaper. Desocclusol was used as a solvent, and irrigation with 2.5% NaOCl was performed. Each group was divided into subgroups according to the timing of radiographic readings. The images were imported into a software program to measure the remaining filling material, the apical extrusion, and the root canal space. The data were statistically analyzed using the Z-test and JASP graphics software. Results: No significant differences were found between the D-Race and S1 groups for primary retreatment; however, using a complementary cleaning method increased the removal of remnant filling (p < 0.05). Conclusions: Classical removal of canal filling material may not be sufficient for root canal disinfection, although a complementary finishing approach improved the results. Nevertheless, all systems left some debris and caused apical extrusion.

근관의 치경부 조기 확대가 치근단 잔사 정출에 미치는 효과 (THE EFFECT OF EARLY CORONAL FLARING ABOUT APICAL EXTRUSION OF DEBRIS)

  • 김민경;미정범;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제29권2호
    • /
    • pp.147-152
    • /
    • 2004
  • The purpose of this study was to investigate the quantity of debris which was extruded apically after canal instrumentation using different types of enlarging instrument in endodontic resin models. Five groups of 9 endodontic resin models were instrumented using each different technique : hand instrumentation without early coronal flaring. hand instrumentation after early coronal flaring. and three nickel-titanium engine-driven instrumentations (Hero 642, Protaper, $K^$). Debris extruded from apical foramen during instrumentation was collected on preweighed CBC bottle, desiccated and weighted using electronic balance. The results were analyzed using Kruskal-wallis test and Mann-Whitney U rank sum test at a significance level of 0.05. The results were as follows: 1. All of instrumentation techniques produced apically extruded debris. 2. Group without early coronal flaring extruded significant more debris than groups with early coronal flaring. 3. There was no significant difference among early coronal flaring groups. The early coronal flaring is very important to reduce the amount of debris extruded apically.

A study on the quantity of apical extrusion of debris according to early coronal flaring

  • Kim, Min-Kyung;Hwang, Ho-Keel
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.580-580
    • /
    • 2003
  • I. Objectives This study investigated the quantity of debris which was extruded apically after canal instrumentation using different types of enlarging instrument in endodontic resin models. II. Materials and Methods Five groups of 9 endodontic resin model were instrumented using each different technique:hand instrumentation without early coronal flaring, hand instrumentation after early coronal flaring, and three nickel-titanium engine-driven instrumentations(Hero 642, Protaper, K3) after early coronal flaring.(omitted)

  • PDF

근관형성법이 근관잔Δ사의 치근단 정출에 미치는 영향 (EFFECT OF CANAL PREPARATION METHODS ON THE APICAL EXTRUSION OF DEBRIS)

  • 박주명;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.399-407
    • /
    • 1999
  • 근관 형성중 잔사의 치근단 정출은 치근단 조직의 반응을 유발하여 동통과 부종을 일으키며 치유를 지연시킬 수 있다. 본 연구의 목적은 수종의 기구와 방법을 사용하여 근관을 형성하고 이에 따른 근관 잔사의 치근단 정출량을 비교함으로써 잔사의 정출을 최소화 할 수 있는 기구 조작법을 알아보고자 하는 것이다. 120개의 발거된 사람의 하악 절치에서 근관형성중 치근단으로 정출되는 잔사의 양을 비교하였다. 첫 번째 실험에서는 40개의 치아를 10개씩 4군으로 나누어 2.52% 치아염소산나트륨용액으로 근관을 세척하면서 다음의 4방법 중 하나를 이용하여 근관을 형성하였다. 수동 스테인레스 스틸 K-화일을 이용하여 step-back technique, crown-down pressureless technique으로 근관을 형성하였고 전동 니켈 티타늄 기구로는 Quantec SC series 2000과 Profile .04 taper series 29를 이용하여 근관을 형성하였다. 두 번째 실험에서는 80개의 치아를 16개씩 5군으로 나누고 근관 세척에 의한 잔사의 치근단 정출 영향을 배제하고자 근관 세척을 시행하지 않고 근관을 형성하였다. 이 때에는 첫 번째 실험의 방법중 Quantec SC series 2000 대신에 Quantec SC 및 Quantec LX를 이용하여 근관을 형성하였고 나머지는 첫 번째 실험과 동일하게 시행하였다. 각 치아로부터 정출되는 잔사를 용기에 모아 24 시간동안 건조시킨 후 전자 저울로 무게를 측정, 비교하여 다음과 같은 결과를 얻었다. 근관 세척을 시행한 경우와 시행하지 않은 경우 공히 step-back technique을 사용한 군에서는 다른 군에 비해 현저히 많은 량의 치근단 정출 잔사가 나타났다. 그러나, crown-down technique을 이용하여 근관 형성한 군과 수종의 Ni-Ti 파일을 이용하여 전동으로 근관 형성한 군들 사이에는 정출 잔사량에 유의한 차이가 나타나지 않았다. 따라서, 본 실험에 사용된 수동 및 전동 기구의 종류는 근관 잔사의 치근단 정출에 영향을 미치지 않는 것으로 생각되며, 근관잔사의 치근단 정출을 최소화하기 위해서는 수동 및 전동 기구 공히 step-back 방법에 의한 filing 동작보다는 crown-down technique의 reaming 동작을 사용하여 근관을 형성하는 것이 바람직하다고 사료된다.

  • PDF

Cu-TiB2 복합재료의 마모거동에 따른 미세조직 관찰 (Observation on the Microstructures of Cu-TiB2 Composites with Wear Behavior)

  • 이태우;강계명
    • 한국재료학회지
    • /
    • 제16권8호
    • /
    • pp.511-515
    • /
    • 2006
  • The dispersion hardened $Cu-TiB_2$ composites are a promising candidate for applications as electrical contact materials. The $Cu-TiB_2$ composites for electrical contact materials can reduce material cost and resource consumption caused by wear, due to their good mechanical and electrical properties. In this study, we investigated the wear phenomenon for $Cu-TiB_2$ composites fabricated with hot extrusion, by varying particle sizes and volume fractions of $TiB_2$. The wear tests were performed under the dry sliding condition with a fixed total sliding distance of 40 m. The contact loads at a constant speed of 3.5 Hz were 20, 40, 60, and 80 N. The friction coefficients and wear losses were measured during wear tests. Worn surfaces and wear debris after wear tests were investigated using the scanning electron microscope and the optical microscope. The microstructures of interface between Cu matrix and $TiB_2$ particle before and after wear tests were studied by the transmission electron microscope.

TiB2 분말로 강화된 Cu-TiB2 복합재료의 내마모특성 (The Characteristics of Wear Resistance of Cu-TiB2 Composites Reinforced by TiB2 Powders)

  • 이태우;최종운;강계명
    • 한국재료학회지
    • /
    • 제15권12호
    • /
    • pp.824-828
    • /
    • 2005
  • In this study the effect of the content of $TiB_2$ on wear properties was investigated. $Cu-TiB_2$ composites have been fabricated by hot extrusion. Sliding wear tests were peformed by a pin-on-disk type wear test machine under dry condition and loads varied with from 20N to 80N at sliding speed 3.5Hz. The test results showed that the wear losses and the friction coefficients decreased with increasing $Cu-TiB_2$ volume fraction and increasing the size of $Cu-TiB_2$ particle. Wear property of $10{\mu}m,\;5 vol\%\; TiB_2$ specimen was excellent all of the wear specimens. It is thought that the increase of plastic flow resistivity due to uniform distribution of $10{\mu}m,\;5 vol\%\; TiB_2$ wear specimen would improve wear property. The worn surface and wear debris were examined by optical microscope and scanning electron microscope.