• 제목/요약/키워드: Dean vortex

검색결과 17건 처리시간 0.023초

Effects of Natural Convection Instability on Membrane Performance in Dead-end and Cross-flow Ultrafiltration

  • Youm, Kyung-Ho;Anthony G. Fane
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1995년도 춘계 총회 및 학술발표회
    • /
    • pp.6-10
    • /
    • 1995
  • An inevitable problem feature of membrane processing is concentration polarization (CF) which is a result of the accumulation of retained solutes at the membrane surface. In ultrafiltration (UF), this accumulation can lead to fouling due to the irreversible deposition of macromolecules both at the membrane surface and in the membrane pores. To reduce or control CP and folding, many possible methods have been considered [1]. One of the most effective approaches is to induce fluid instability near the membrane surface by using pusation flow [2, 3], Taylor [4] and Dean [5, 6] vortex flows. Winzeler and Belfort [6] have comprehensively reviewed several possible attempts to use fluid instabihties for improved membrane performance.

  • PDF

회전하는 덕트내 설치된 $70^{\circ}$ 경사요철의 열전달 특성 (Heat Transfer in Rotating Duct with $70^{\circ}$ Angled Ribs)

  • 최청;이세영;원정호;조형희;박병규
    • 한국유체기계학회 논문집
    • /
    • 제4권3호
    • /
    • pp.7-13
    • /
    • 2001
  • The present study investigates convective heat/mass transfer and flow characteristics inside a cooling passage of rotating gas-turbine blades. The rotating duct has staggered ribs with $70^{\circ}$ attack angle, which are attached on leading and trailing surfaces. Naphthalene sublimation technique is employed to determine detailed local heat transfer coefficients using the heat and mass transfer analogy. Additional numerical calculations are conducted to analyze the flow patterns in the cooling passage. The present experiments employ two-surface heating conditions in the rotating duct because the exposed surfaces to hot gas stream are pressure and suction side surfaces in the middle passages of an actual gas-turbine blade. Secondary flows are generated by Coriolis and centrifugal forces in the spanwise and streamwise directions. The ribs attached on the walls disturb the mainflow resulting in recirculation and secondary flows near the ribbed wall. The local heat transfer and flow patterns in the passage are changed significantly according to rib configurations and duct rotation speeds. Therefore, the geometry and arrangement of the ribs are important for the advantageous cooling performance. The experimental results show that the ribs enhance the heat transfer more than $70\%$ from that of the smooth duct. The duct rotation generates the heat transfer discrepancy between the leading and trailing walls due to the secondary flows induced by the Coriolis force. The overal heat transfer pattern on the leading and trailing walls for the first and second passes are depended on the rotating speed, but the local heat transfer trend is affected mainly by the rib arrangements.

  • PDF

곡관부를 가지는 내부 냉각유로에서 회전수 변화에 따른 열전달 및 유동 특성 ( I ) - 엇갈린 요철배열 덕트 - (Effects of Rotation Speed on Heat Transfer and Flow in a Coolant Passage with Turning Region ( I ) - Cross Ribbed Duct -)

  • 김경민;김윤영;이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제29권6호
    • /
    • pp.737-746
    • /
    • 2005
  • The present study investigates heat/mass transfer and flow characteristics in a ribbed rotating passage with turning region. The duct has an aspect ratio (W/H) of 0.5 and a hydraulic diameter ($D_h$) of 26.67 mm. Rib turbulators are attached in the cross arrangement on the leading and trailing surfaces of the passage. The ribs have a rectangular cross section of $2\;mm\;(e){\times}\;mm\;(w)$ and an attack angle of $70^{\circ}$. The pitch-to-rib height ratio (p/e) is 7.5, and the rib height-to-hydraulic diameter ratio ($e/D_h$) is 0.075. The rotation number ranges from 0.0 to 0.20 while the Reynolds number is constant at 10,000. To verify the heat/mass transfer augmentation, internal flow structures are calculated for the same conditions using a commercial code FLUENT 6.1. The heat transfer data of the smooth duct for various Ro numbers agree well with not only the McAdams correlation but also the previous studies. The cross-rib turbulators significantly enhance heat/mass transfer in the passage by disturbing the main flow near the surfaces and generating one asymmetric cell of secondary flow skewing along the ribs. Because the secondary flow is induced in the first-pass and turning region, heat/mass transfer discrepancy is observed in the second-pass even for the stationary case. When the passage rotates, heat/mass transfer and flow phenomena change. Especially, the effect of rotation is more dominant than the effect of the ribs at the higher rotation number in the upstream of the second-pass.

회전하는 터빈 블레이드 이차유로내 요철 배열이 열/물질전달에 미치는 영향 (Effect of Heat/Mass Transfer in the turbine blade internal passage with various rib arrangement)

  • 이세영;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.22-29
    • /
    • 2001
  • The present study investigates the effects of various rib arrangements and rotating on heat/mass transfer in the cooling passage of gas turbine blades. The cooling passage has very complex flow structure, because of the rib turbulator and rotating effect. Experiments and numerical calculation are conducted to investigate the complex flow structures and heat transfer characteristics; the numerical computation is performed using a commercial code, FLUENT ver.5, to calculate the flow structures and the experiments are conducted to measure heat/mass transfer coefficients using a naphthalene sublimation technique. For the rotating duct tests, the test duct, which is the cross section of is $20mm\times40mm$ (the hydraulic diameter, $D_h$, of 26.7 mm, has two-pass with $180^{\circ}$ turning and the rectangular ribs on the wall. The rib angle of attack is $70^{\circ}$ and the maximum radius of rotation is $21.63D_h$. The partition wall has 10 mm thickness, which is 0.5 times to the channel width, and the distance between the tip of the partition wall and the outer wall of the turning region is 26.7 mm $(1D_h)$. The turning effect of duct flow makes the very complex flow structure including Dean type vortex and high turbulence, so that the heat/mass transfer increases in the turning region and at the entrance of the second pass. The Coriolis effect deflects the flow to the trailing surface, resulting in enhancement of the heat/mass transfer on the trailing surface and reduction on the leading surface in the first pass. However, the opposite phenomena are observed in the second pass. The each rib arrangement makes different secondary flow patterns. The complex heat/mass transfer characteristics are observed by the combined effects of the rib arrangements, duct rotation and flow turning.

  • PDF

덕트 종횡비가 회전덕트 내 압력강하에 미치는 영향 (Effect of Duct Aspect Ratios on Pressure Drop in a Rotating Two-Pass Duct)

  • 김경민;이동현;조형희
    • 대한기계학회논문집B
    • /
    • 제30권6호
    • /
    • pp.505-513
    • /
    • 2006
  • The pressure drop characteristics in a rotating two-pass duct with rib turbulators are investigated in the present study. Three ducts of different aspect ratios (W/H=0.5, 1.0 and 2.0) are employed with a fixed hydraulic diameter ($D_h$) of 26.7 mm. $90^{\circ}$-rib turbulators with $1.5mm{\times}1.5mm$ cross-section are attached on the leading and trailing surfaces. The pitch-to-rib height ratio (p/e) is 1.0. The distance between the tip of the divider and the outer wall of the duct is 1.0 W. The thickness of divider wall is 6.0 mm o. 0.225 $D_h$. The Reynolds number (Re) based on the hydraulic diameter is kept constant at 10,000 and the .elation number (Ro) is varied from 0.0 to 0.2. As duct aspect ratio increases, high friction factor ratios show in overall regions. The reason is that the rib height-to-duct height ratio (e/H) increases, but the divider wall thickness-to-duct width ($t_d/W$) decreases. The rotation of duct produces pressure drop discrepancy between the leading and trailing surfaces. However, the pressure drop discrepancy of the high duct aspect ratio (AR=2.0) is smaller than that of the low duct aspect ratio (AR=0.5) due to the decrement of duct hight (H).

열교환기 내부 유로의 꺾임각 변화에 따른 국소 열/물질전달 특성 고찰 (Effects of Corrugation Angle on Local Heat/Mass Transfer in Wavy Duct of Heat Exchanger)

  • 장인혁;황상동;조형희
    • 대한기계학회논문집B
    • /
    • 제28권7호
    • /
    • pp.789-799
    • /
    • 2004
  • An experimental study is conducted to investigate the effects of duct corrugation angle on heat/mass transfer characteristics in wavy ducts of a primary surface heat exchanger application. Local heat/mass transfer coefficients on the wavy duct sidewalls are determined by using a naphthalene sublimation technique. The corrugation angles(${\alpha}$) of the wavy ducts are 145$^{\circ}$, 130$^{\circ}$, 115$^{\circ}$ and 100$^{\circ}$. And the Reynolds numbers based on the duct hydraulic diameter vary from 300 to 3,000. The results show that at the low Re(Re $\leq$1000), the secondary vortices called Taylor-Gortler vortices perpendicular to the main flow direction are generated due to effect of duct curvature. By these secondary vortices, high heat/mass transfer regions are formed on both pressure-side and suction-side walls. At the high Re(Re $\geq$ 1000), these secondary flows are vanished with helping flow transition to turbulent flow and the regions which show high heat/mass coefficients by flow reattachment are formed on suction side. As corrugation angle decreases, the local peak Sh induced by Taylor-Gortler vortices increase at Re $\leq$1000. At high Re(Re $\geq$ 1000), by the existence of different kind of secondary flows called Dean vortices, non-uniform Sh distribution appears along spanwise direction at the narrow corrugation angle (${\alpha}$=100$^{\circ}$). Average Sh also increase by the enhanced effect of secondary vortices and flow reattachment. More pumping power (pressure loss) is required with the smaller corrugation angle due to the enhancement of flow instability.

미세 유체 기반의 형광 다중 암 진단 센서 플랫폼 설계 (Design of Fluorescence Multi-cancer Diagnostic Sensor Platform based on Microfluidics)

  • 이병권;칼리크 아민;정명영
    • 마이크로전자및패키징학회지
    • /
    • 제29권4호
    • /
    • pp.55-61
    • /
    • 2022
  • 다중 암의 동시 진단 기술에 대한 관심이 전 세계적으로 증가하는 추세이며, 진단 난이도를 낮추기 위해 혈액과 같은 미량의 바이오 유체를 이용하여 질병을 진단하는 미세 유체 소자 기반의 액체 생검 기술이 연구되고 있다. 바이오 유체를 이용하여 형광 영상 등을 통해 분석물질의 농도를 측정하는 광학적 바이오 센싱에 있어 민감도를 향상시키기 위한 기술개발이 필요하다. 본 논문에서는 모세관력에 의한 자가구동 기반의 마이크로 채널의 기하학적 구조와 미세 유체 현상만으로 수동적 자기 혈장 분리 기술과 유체 혼합을 통한 분자 인식 활성화 기능을 구현하는 형광 다중 암 진단 센서 플랫폼 구조를 제안하고 설계하였다. 설계된 센서의 혈장 분리부의 성능에 영향을 미치는 파라미터를 확인하기 위해 채널의 수력학적 직경과 종횡비, 유체의 점도를 변수로 설정하여 딘 와류 형성 여부를 시뮬레이션을 통해 확인하였고 최적의 센서 플랫폼 구조를 제시하였다.