Dead-end Mode Operation of a Large Scale PEM Fuel Cell Stack (대면적 고분자전해질 연료전지의 데드엔드 운전)

  • Jeong, Jeehoon;Shin, Hyunkhil;Han, In-Su;Seo, Hakyu;Kim, Minsung;Cho, Sungbaek;Hur, Taeuk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.83.1-83.1
    • /
    • 2010
  • A Dead-end mode operation is one of the best way to maximize the gas usage rate. But, some components of fuel cell stack like gas diffusion layer(GDL) or membrane can be damaged in dead-end mode operation. In this study, a Large Scale Polymer electrolyte membrane fuel cell(PEMFC) for a dead-end operation has been developed. The stack is composed with 4 cells which has over 400cm2 of active area. Hydrogen is used as a fuel, and oxygen is used as a oxidant. The dead-end operation performance was evaluated by a long-term dead-end mode operation. The fuel cell stack is operated over 1,500 hours in dead-end mode operating fuel cell test station. And the performance change of the fuel cell stack was investigated.

  • PDF

Density-surfactant-motivated removal of DNAPL trapped in dead-end fractures

  • 여인욱;이강근;지성훈
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.51-54
    • /
    • 2003
  • Three kinds of experiments were conducted to test existing methods and develop an effective methodology for the remediation of DNAPL trapped in vertical dead-end fractures. A water-flushing method failed to remove TCE from vertical dead-end fractures where no fluid flow occurs. A water-flushing experiment implies that existing remediation methods, utilizing water-based remedial fluid such as surfactant-enhanced method, have difficulty in removing DNAPL trapped from the vertical downward dead-end fractures, because of no water flow through dead-end fractures, capillary, and gravity forces. Fluid denser than TCE was injected into the fracture network, but did not displace TCE from the vertical dead-end fractures. Base(B on the analysis of the experiments, the increase in the density of the dense fluid and the addition of surfactant to the dense fluid were suggested, and this composite dense fluid with surfactant effectively removed TCE from the vertical dead-end fractures.

  • PDF

Small Hydrogen Regulator for Mobile Fuel Cells (모바일 연료전지용 초소형 수소 레귤레이터)

  • Kim, Hyung-Jin;Seo, Young-Ho;Kim, Byeong-Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.2
    • /
    • pp.129-132
    • /
    • 2011
  • This paper presents small hydrogen regulator for the mobile fuel cell. Mobile fuel cell is generally classified into open-end type and dead-end type. In the open-end type, flow rate of hydrogen is constantly controlled, while pressure of hydrogen is constantly maintained in the dead-end type. Considering the efficiency and stability of the fuel usage, dead-end type is more suitable with mobile fuel cell. Mobile fuel cell operated by dead-end mode requires hydrogen regulator which controls the hydrogen pressure from 0.1bar to 0.5bar within 3% error. In this paper, small hydrogen regulator (volume of 2.6cc) was fabricated by stainless steel. Regulation characteristics was experimentally evaluated.

A Study on the Methodologies of Korean Language Processing Avoiding Dead-end State (통제불능 상태를 회피하는 한국어 정보처리 방법론 연구)

  • Kang, Seung-Shik
    • Speech Sciences
    • /
    • v.5 no.1
    • /
    • pp.89-103
    • /
    • 1999
  • It is relatively easy to develop a prototype of a Korean language processing system, but it is very difficult to make it an operational system. In this paper, we survey the current status and methodological issues of the Korean language processing systems such as morphological analyzer, parser and machine translator. In most cases, Korean language processing system easily comes to a dead-end state where its performance can not be improved any more. The reason is that it adopts a general algorithm covering similar problems as a whole because specific low-level problems are not clearly defined and their algorithms are unclear. So, when we add some restrictions to solve an individual linguistic problem, they are also applied to other linguistic phenomena as a side effect. It causes a critical problem that the improvement of the algorithm is very difficult. This paper proposes a 2-step paradigm, a divide-and-conquer method by the functional modularization, a simplification method, and an exception handling technique to develop an operational system that does not fall into a dead-end state.

  • PDF

Permeation Behavior of Semiconductor Rinsing Wastewater Containing Si Particles in Ultrafiltration System -II. Permeation Characteristics of Tubular Membrane (Si 입자를 함유한 반도체 세정폐수의 한외여과 특성 [II] -Polyolefin 관형막에 의한 투과분리-)

  • 남석태;여호택;전재홍;이석기;최호상
    • Membrane Journal
    • /
    • v.9 no.1
    • /
    • pp.36-42
    • /
    • 1999
  • Permeation behavior of the semiconductor rinsing wastewater contammg Si particles was examined by ultrafiltration using the polyolefin tubular membrane. Flux decline with time was due to the growth of Si cake deposited on the membrane surface and the pore plugging by Si particles. Cake filtration from the cross flow application is compared to the combination of pore blocking and cake filtration from the dead-end application. The cake resistance is 3.16 x $10^{12}$ -4.34 X $\times$$10^{12}$ $m^{-1}$ for the cross flow and 6.6 x $\times$$10^{12}$ -12.19 X $\times$$10^{12}$ $\times$$m^{-1}$for the dead-end flow, respectively. At the initial stage of operation, permeation flux of cross flow type was 1.7 time higher than that of the dead end flow type. Permeation flux of cross flow was about 42 e 1m2 hr and the rejection rate of Si particles was about 96 %. The average particle size of Si particle in the permeate was 20 nm.

  • PDF

An experimental study on the performance improvement of dead-end type PEMFC with pulsating effect (맥동 효과를 이용한 dead-end type 연료전지의 성능향상에 대한 실험적 연구)

  • Choi, Jong-Won;Seo, Jeong-Hoon;Hwang, Yong-Sheen;Lee, Dae-Heung;Cha, Suk-Won;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.567-571
    • /
    • 2008
  • PEM Fuel Cell operation mode can be classified into dead-end mode or open mode by whether the outlet port is blocked or not. Generally, dead-end type fuel cell has some merits on the pressure drop and system efficiency because it can generate more power than the open type fuel cell due to high operating pressure condition. However, the periodic purging process should be done for removing water which is formed as product of a reaction in the gas diffusion layer. In this study, cathode side dead-end type operation has been conducted. Moreover, pulsating flow generator at the outlet of cathode side has been suggested for increasing the period to purge the formed water because the pulsating flow can make formed water scattered uniformly over the whole channel. As a result, the purging period with pulsation increased by 1.5-2 times longer than that without pulsating.

  • PDF

Characteristics of a Corona between a Wiring Clamp (Dead End Clamp) and a Porcelain Insulator Used in a 154kV Power Receptacle

  • Han, Woon-Ki
    • International Journal of Safety
    • /
    • v.7 no.1
    • /
    • pp.21-25
    • /
    • 2008
  • The occurrence of a corona is that electrical discharge due to the heterogeneity that occurs when an electrical field is concentrated in an electrode due to a cusp formed on said electrode. Wire treatment at the end of a 154kV dead end clamp for end users accelerates the occurrence of corona, which in turn leads to power loss and noise. In this study, the characteristics of the corona which occurs between porcelain insulators and support clamps of overhead lines used in l54kV power receiving facilities for end users were investigated. The corona, which cannot be identified by one common method, was measured utilizing a UV image camera. A risk assessment for fire damage and its status was suggested. The stress distribution of the electrical field by length of bare wire was suggested by means of the finite element method (FEMLAB). As a result, it was found to affect a porcelain insulators. These results can be utilized for the enhancement of clamp installation and safety in power facilities.

Preventing Method against the Occurrence of a Corona between a Dead End clamp and a Porcelain Insulator Used in 154kV Substation

  • Han, Woon-Ki;Choi, Jong-Soo;Lee, Jun;Kim, Jae-Chul
    • International Journal of Safety
    • /
    • v.6 no.2
    • /
    • pp.22-26
    • /
    • 2007
  • An episode of corona is a heterogeneity-caused electric discharge that occurs when electric fields are formed layer on layer and concentrated on an electrode. Electric wires built at the tip of 154kV private facilities use dead end clamp spawns corona from homogeneity caused by field concentration. Corona induces power loss, noise, insulator failure and more. In this research, we've studied the characteristics of coronas that take place in porcelain insulators and terminal electric wires of supporting hard wares (dead end clamp) that are set up as spares in the 154kV private facilities use hydroelectricity installations to support electric wires. Corona, which cannot be identified by regular methods, was measured utilizing UV image camera. As the result of measuring corona via UV image camera, we've confirmed that the depletion of insulators was accelerated following the wire end treatment method and validated the stress intensity of insulators at various lengths of bare wires caused by electric fields via FEMLAB. We have also proposed a new model for relieving homogeneity-caused field concentration, and after analyzing the proposed model via FEMLAB, we've confirmed that the concentration of field distribution was indeed reduced. Such results are exploited in installation of private facilities use equipments, maintenance of insulators and hard wares as well as safety enhancement, and are anticipated to be effectively utilized in corona prevention measures.

A study on the characteristic of the anodic dead-end mode PEM fuelcell and performance improvement by pulsation effect (수소 데드 앤드 연료전지의 특성 및 맥동을 이용한 성능 향상에 관한 실험적 연구)

  • Choi, Jong-Won;Hwang, Yong-Sheen;Kim, Sung-Il;Ha, Jeong-Hoon;Park, Joon-Ho;Cha, Suk-Won;Kim, Min-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.336-340
    • /
    • 2009
  • This paper presents experimental results carried out on the purge characteristic of the anodic dead-end mode fuelcell and how to improve the cell performance by pulsation effects. The dead-end mode fuelcell has some merits that a fuel supplying device is not needed and the cell power is higher than that in the open mode fuelcell. However, the purge is necessary for preventing the porous media from being flooded by liquid water formed in the channel. At this time, the un-reacted fuel is discharged with the liquid water together in purge process. The discharged fuel can make the fuel efficiency lower. Therefore, the number of purge times should be decreased for the better fuel efficiency. In this study, the outlet of the anode channel was equipped with a purge solenoid valve and a pulsation generator. The purge times was decreased when the current density decreased and operation pressure increased without the pulsation effects. In addition, when the pulsation effects such as various frequencies or amplitudes were applied, purge times was alleviated up to 40%.

  • PDF