• 제목/요약/키워드: Daylighting system

검색결과 113건 처리시간 0.034초

지하주차장 빛환경 개선을 위한 광파이프 시스템의 채광성능 평가에 관한 연구 (Performance Assessment of Light Pipe System for the Advanced Luminous Environment of the Underground Parking Lot)

  • 신주영;황태연;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제30권1호
    • /
    • pp.25-33
    • /
    • 2010
  • Use of daylight in underground space interacts with physiological need for human beings and provides relief from feeling secluded. Light pipe system can deliver natural light into the space where it is needed and can be used as primary or a secondary light source with benefits of energy, productivity and health. To use light pipe system effectively under various conditions, it is important to investigate the effectiveness of light pipe system with reliable monitoring protocol. This paper presents the results of light pipe system performance used in underground parking lot under different sky conditions. Comparisons were made between the illuminance standards of underground parking lot and the monitored data. The results indicated that adequate illuminance level was shown until 4.5m distance from the light pipe under clear sky condition. However, additional lighting device showed be used under overcast sky to meet the proper illuminance level.

소규모 사무공간에서 디밍제어를 이용한 조명에너지 절약에 관한 연구 (A Study on lighting Energy Conservation in a Small Office Space with Daylight Dimming Control System)

  • 김한성;김강수
    • 조명전기설비학회논문지
    • /
    • 제17권5호
    • /
    • pp.15-21
    • /
    • 2003
  • 본 연구에서는 소규모 사무공간을 대상으로 주광과 인공조명의 성능 평가를 위한 디밍제어 시스템의 실험을 실시함으로써, 사무소 건물의 조명에너지 절약을 도모할 수 있는 성능 평가 자료를 제시하고자 한다. 본 연구에서는 성능 평가폭 위해 Mock-Up Room(3.6${\times}$7.2${\times}$2.6(m))을 사용하여 측정하였으며, 연구 결과는 다음과 같다; 1) 주광작업면조도와 센서조도간의 상관관계는 디밍 시스템의 성능에 영향을 미치는 중요한 요소이다. 2) 디밍 시스템을 적용한 본 실험에서는 주광과 인공조명을 포한함 총 작업면조도는 월평균 579[lux], 월간 에너지 절감율은 약 53[%]로 나타났다.

주택성능등급표시제도 성능항목의 특성 및 시계열분석( I ) (A Time series Analysis on the Performance Items of the "Housing Performance Grading Indication System")

  • 이성옥;김수암;신성은
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.213-216
    • /
    • 2009
  • The purpose of this study is analyzing temporal flow about 20 detailed performance items in the "Housing Performance Grading Indication System". This study try to figure out situations according grade in detailed performance item and to analyze change item about 112 cases(2 cases in 2006, 15 cases in 2007, 46 cases in 2008, 49 cases in 2009), from January 9, 2006 which system is undertaken, to October, 2009. This system consists of 5 main performance section, 14 performance categories and 20 detailed performance items. 5 main performance parts are Noise and Acoustics(Light-weight impact sound control, heavy-weight impact sound control, sound control of toilet, sound control of party wall), Long-life(flexibility, remodeling & maintenance, durability), Landscape & Indoor Environment(landscape, formaldehyde control & ventilation, daylighting, thermal environment), Welfare & Barrier-free(playground and community center, welfare space, barrier-free design), Fire Safety(fire safety, safe place, fire-resisting quality). Total efficiency about housing can understand systematically of 20 perfomance items though this research.

  • PDF

광기능성 창호시스템의 동절기 채광특성에 관한 목업연구 (Full-scale Mock-up Measurement of a Double Glazed Window System Equipped with Sunlight Controls)

  • 김곤
    • 한국태양에너지학회 논문집
    • /
    • 제28권4호
    • /
    • pp.35-42
    • /
    • 2008
  • Besides genuine skin and clothes, it is called that building is third skin for us. That means the skin of buildings is the most important factor for our man-made environment. The issues in designing the building envelope include the insulation, infiltration, ventilation and bridging in windows. Getting light into the space safely and providing views to outdoor, additionally, are key things with the building envelope design. A deep-rooted preference for full view is still alive with large area of glass. Balcony expansion is legalized in apartment houses, which causes lots of environmental problems. Without balcony space, the adjacent space to unshaded window is exposed to the direct sun. A window can have many layers and the inner space can be utilized with an automatic blind system. Recently, the refurbished version of a double-glazed window system has been developed for the purpose of minimizing energy loss occurred around windows. For the better daylight control with equipped blind system, a set of adjustment technique of blind slats was tested in a mock-up building and recommended the detail operation. Not surprisingly, the optimized blind system can be oriented to enhance the uniformity in light distribution and direct glare from the sky as well..

태양정밀추적 알고리즘의 LabVIEW 적용 연구 (The Study on the Application of Accurate Solar Tracking Algorithm by using LabVIEW)

  • 오승진;김영민;이윤준;조일식;천원기
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.121-125
    • /
    • 2009
  • There have been many developed systems for harnessing the solar energy such as solar water heaters, solar thermal power systems, PV systems, daylighting and solar hydrogen systems. all of them are capable of reducing $CO_2$ emission. However, the efficiency of those systems which work without a solar tracker is lower. This paper is a step by step procedure for fabrication and a performance test of a solar tracking system. The system developed in this study consists of motion controllers, motor drives, step-motors, feedback devices and application. CdS sensors are introduced into the solar tracking system for playing a primary role in poor conditions for tracking due to a gear backlash and a strong wind. Mini-dish was used as a concentrator for collecting sun light. The solar position data, in terms of azimuth and elevation, sunrise and sunset times was compared with those of KASI(Korea Astronomy & Space Science Institute). The results presented in this article provide the high accuracy of the present system in solar tracking and indicate a potential for energy savings.

  • PDF

프레넬 필름을 이용한 태양광 채광시스템 연구 (A Study on Solar Light Collector using Fresnel Lens Film)

  • 정학근;한수빈;정봉만;이의준;임상훈
    • 한국태양에너지학회 논문집
    • /
    • 제22권1호
    • /
    • pp.81-86
    • /
    • 2002
  • Solar daylighting system provides free and comfort lighting, but its design and control has been key issue due to heavy light collecting system. One of the solutions for the heavy weight issues would be using a light framed film such as fresnel and prism lens. This prototype system consists of light collector, light transformer and light guide luminaire. The light collector which is installed at window or the rooftop concentrates solar light, the collected beam is converted to suitable light by the light transformer. and the prism light guide luminaire has been used to distribute light emitted from light transformer for illumination. In this paper, the design concept and performance of light collector in this prototype system are presented.

국제 자연채광 측정 프로그램의 동향 (Trends of International Daylight Measurement Programme)

  • 김회서
    • 태양에너지
    • /
    • 제13권2_3호
    • /
    • pp.30-36
    • /
    • 1993
  • 본 논문(論文)은 자연채광 측정(測定)에 대한 국제적 동향(動向)으로서 건물에 있어서 자연채광을 다양한 기후조건(氣候條件)에 따라 보다 최대한으로 이용하고자 국제 조명학회(照明學會)(CIE)는 세계적으로 연구(硏究)클래스와 일반(一般)클래스 등 몇개의 클래스로 연구측정계획을 추진중에 있으며 전 세계의 여러 국가에 있어서 조도(照度)와 일사량에 대한 측정(測定) 데이터를 수집하여 천공(天空) 상태에 따른 자연채광 설계에 대한 기초적 자료를 확립 시키고자 하고 있다.

  • PDF

투과시스템의 광학특성을 고려한 복합적 외벽채광부의 성능평가에 관한 연구 (Design and Performance Evaluation of Hybrid Window Walls With Variable Transmittal Materials)

  • 도진석;김곤;김정태
    • KIEAE Journal
    • /
    • 제4권2호
    • /
    • pp.11-18
    • /
    • 2004
  • Growing use of entire glass facades with metal frames are popularly witnessed in modern building practices and design competition as well. In spite of architectural aesthetics and view to outdoors, environmental issues still exist in that kind of buildings. One of the solutions for the problems might be the use of functional glasses such as a heat-resistant glass or various tinted glasses for the glass walls. This paper aims to provide performance data related to the impact of various transmittal materials of window systems on the light distribution. A series of computer simulation deals with the basic geometrical and optical design elements of a commonly used all-glass facades. Additionally an experimental configuration of the vertical window is proposed for better result of daylighting. A window system equipped with an inner-light shelf can improve the uniformity of natural light in a space by reducing the level of illumination near the window and redirecting light deeply into the space.

중정형 공동주택의 공간계획 특성 연구 (A Study on the Characteristics of Court Housing Design in Korea)

  • 강인호;박소영
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2005년도 추계학술대회 논문집
    • /
    • pp.263-268
    • /
    • 2005
  • The aim of this study was to analyse the design characteristics of court housing. In spite of changes of housing design condition, especially density, there have been changes only in the height of housing block, not in the housing types, layout system and other design properties. Due to the situation, housing design in Korea has been criticised as too routine and monotonous one. As one of the alternatives to respond to the criticism, this study focused on the positive aspects of the court housing type, and suggested the design strategies throughout the analysis of 8 entries in the design competition of EunPyeong NewTown, which attempted to overcome the negative problems - mainly the daylighting, orientation, and privacy- of this housing type. Throughout the analysis, there suggested design strategies to respond to the problems of court housing type, which can be the basis for the court housing design in Korea.

  • PDF

첨단 태양광채광시스템의 개발현황 및 활용실태 분석에 관한 연구 (An Analysis on Development and Application of Solar Sunlighting Systems)

  • 김정태;황민구;한봉수
    • KIEAE Journal
    • /
    • 제2권1호
    • /
    • pp.63-68
    • /
    • 2002
  • Solar sunlighting systems are useful to apply for most buildings. This study aims to analysis the development and architectural application of solar sunlighting systems. For the purpose, abroad developing situation of solar sunlighting systems were investigated and analyzed literally. And, by case studies, architectural application methods are analyzed. As results, light pipe systems are mainly used for small building and houses. Also solar mirror systems are used for atrium and underground spaces. Lens-fiber systems are applied for high rise buildings and office buildings which internally have no influx of sunlighting. Some application suggestion in our country are discussed.