• Title/Summary/Keyword: Daylighting Performance

Search Result 125, Processing Time 0.019 seconds

A Study on the Window Planning of School Building Using ECOTECT Simulation -By Dynamic Daylight Simulation Using Weather Data- (ECOTECT 시뮬레이션을 활용한 학교건축의 창호계획에 관한 연구 -기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로-)

  • Choi, Woo Ram;Han, Seok Jong;Yun, Young Il
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.77-82
    • /
    • 2013
  • Light environment in the school building is one of the most important elements of the plan in order to improve student's ability to learn and the healthy growth. Thus, the window plan of the school building is a great addition to improve environmental-friendly performance through the daylight control. Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the school building design process, because of lack of previous studies on the light environment of student and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. ECOTECT simulation were performed using weather data. As a result, ECOTECT simulation are performed for daylight autonomy and useful daylight illuminance. Using this data, Window planing is to propose and effective method in the early stages of design.

The Performance Evaluation of Photovoltaic-integrated Lightshelf Systems (PV 일체형 태양광발전 광선반시스템의 성능평가)

  • Park, Hoon;Chung, Yu-Gun;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.129-134
    • /
    • 2012
  • The lightshelf system, a daylighting device, has been applied to improve the visual environment by optimal light distributions and intense illumination levels of a interior. Also, The photovoltaic is one of the most important sustainable technologies appliable to architectures. This study aims to evaluate the performance of photovoltaic integrated lightshelf system. For the study, the 1/5 scaled office models were made and the field tests were experimented under clear sky conditions. The power ratio has been analyzed to evaluate the performance of photovoltaic integrated lightshelf system. As results, the power performance was high on photovoltaic lightshelf installation angle $0^{\circ}$. And the performance was reduced on 23(%) by installation angle $15^{\circ}$ and 63(%) by installation angle $30^{\circ}$.

Embossed Structural Skin for Tall Buildings

  • Song, Jin Young;Lee, Donghun;Erikson, James;Hao, Jianming;Wu, Teng;Kim, Bonghwan
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.1
    • /
    • pp.17-32
    • /
    • 2018
  • This paper explores the function of a structural skin with an embossed surface applicable to use for tall building structures. The major diagrid system with a secondary embossed surface structure provides an enhanced perimeter structural system by increasing tube section areas and reduces aerodynamic loads by disorienting major organized structure of winds. A parametric study used to investigate an optimized configuration of the embossed structure revealed that the embossed structure has a structural advantage in stiffening the structure, reducing lateral drift to 90% compared to a non-embossed diagrid baseline model, and results of wind load analysis using computational fluid dynamics, demonstrated the proposed embossed system can reduce. The resulting undulating embossed skin geometry presents both opportunities for incorporating versatile interior environments as well as unique challenges for daylighting and thermal control of the envelope. Solar and thermal control requires multiple daylighting solutions to address each local façade surface condition in order to reduce energy loads and meet occupant comfort standards. These findings illustrate that although more complex in geometry, architects and engineers can produce tall buildings that have less impact on our environment by utilizing structural forms that reduce structural steel needed for stiffening, thus reducing embodied $CO^2$, while positively affecting indoor quality and energy performance, all possible while creating a unique urban iconography derived from the performance of building skin.

Evaluation of Daylighting Performance and Design of a Curved-Lightshelf by the Ray Tracing Method (광선추적기법을 활용한 곡면형 광선반시스템 설계 및 채광성능 평가)

  • Kim, Dong-Su;Yoon, Jong-Ho;Shin, Woo-Chul;Lee, Kwang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.136-141
    • /
    • 2011
  • The lightshelf system reduces intense illumination levels of indoor from direct sun light and reflect to lead diffused light into indoor deeply. This study aims to design acurved-lightshelf by a ray tracing method and evaluate the daylighting performance of window integrated with the curved-lightshelf by computer simulations. For this purpose, evaluation test model was designed for the experiments to validate the simulation model, and the curved-lightshelf was designed by the ray tracing method using Ecotect. After the office model was designed using 3D simulation, the average indoor illuminance, luminance and distribution of illuminance were evaluated by simulation which has a algorithm of Radiosity and Ray-Tracing method under four different cases(case1;no lightshelf, case2; Flat board, case3; tilted at $30^{\circ}$ angle, case4; the curved-lightshelf). As results, it turns out that case1 showed higher average illuminance and case4 was more uniformly distributed than case2 and case3, In addition average luminance of case1 was also lower. indicating that the curved-lightshelf would reduce the possibility of the glare, while maintaining the sufficient daylight level.

Genetic algorithms for balancing multiple variables in design practice

  • Kim, Bomin;Lee, Youngjin
    • Advances in Computational Design
    • /
    • v.2 no.3
    • /
    • pp.241-256
    • /
    • 2017
  • This paper introduces the process for Multi-objective Optimization Framework (MOF) which mediates multiple conflicting design targets. Even though the extensive researches have shown the benefits of optimization in engineering and design disciplines, most optimizations have been limited to the performance-related targets or the single-objective optimization which seek optimum solution within one design parameter. In design practice, however, designers should consider the multiple parameters whose resultant purposes are conflicting. The MOF is a BIM-integrated and simulation-based parametric workflow capable of optimizing the configuration of building components by using performance and non-performance driven measure to satisfy requirements including build programs, climate-based daylighting, occupant's experience, construction cost and etc. The MOF will generate, evaluate all different possible configurations within the predefined each parameter, present the most optimized set of solution, and then feed BIM environment to minimize data loss across software platform. This paper illustrates how Multi-objective optimization methodology can be utilized in design practice by integrating advanced simulation, optimization algorithm and BIM.

Analysis of Energy Performance and Green Strategies in the Foreign High-Performance Buildings

  • Park, Doo-Yong;Kim, Chul-Ho;Lee, Seung-Eon;Yu, Ki-Hyung;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.21-28
    • /
    • 2015
  • Purpose: In this study, we analyzed the energy performance levels and high-performance technology trends through the case studies of foreign high-performance buildings. Method: Buildings built within 10 years were selected for the analysis of recent trends. we analyzed the buildings of U.S.A, Germany and Japan using LEED certified buildings, Passive House certified buildings and CASBEE certified buildings database for the case study of foreign high-performance buildings. A total of 20 high-performance buildings including 14 cases in U.S.A, 4 cases in Germany and 4 cases in Japan were selected. Annual energy consumption levels for 20 high-performance buildings were collected with the actual energy consumption data or data from simulation programs officially recognized by DOE. Annual energy consumption were compared with the energy performance standard of the office buildings in the CBECS database, ASHRAE Standard 90.1-2004 and Building Energy Efficiency Rating System in Korea. Result: The order of the green strategies applied in the main categories are Renewable Energy(63%), Indoor Environment Control(51%), Envelope Improvement(44%) and HVAC System & Control(28%). Specified strategies most widely used in the sub-categories are high-performance Insulation (70%), High Efficiency Heating, Cooling Source Equipment(85%), Photovoltaic&Solar Thermal(80%) and Daylighting(80%).

A Time series Analysis on the Performance Items of the "Housing Performance Grading Indication System" (주택성능등급표시제도 성능항목의 특성 및 시계열분석( I ))

  • Lee, Sung-Ok;Kim, Soo-Am;Shin, Sung-Eun
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.213-216
    • /
    • 2009
  • The purpose of this study is analyzing temporal flow about 20 detailed performance items in the "Housing Performance Grading Indication System". This study try to figure out situations according grade in detailed performance item and to analyze change item about 112 cases(2 cases in 2006, 15 cases in 2007, 46 cases in 2008, 49 cases in 2009), from January 9, 2006 which system is undertaken, to October, 2009. This system consists of 5 main performance section, 14 performance categories and 20 detailed performance items. 5 main performance parts are Noise and Acoustics(Light-weight impact sound control, heavy-weight impact sound control, sound control of toilet, sound control of party wall), Long-life(flexibility, remodeling & maintenance, durability), Landscape & Indoor Environment(landscape, formaldehyde control & ventilation, daylighting, thermal environment), Welfare & Barrier-free(playground and community center, welfare space, barrier-free design), Fire Safety(fire safety, safe place, fire-resisting quality). Total efficiency about housing can understand systematically of 20 perfomance items though this research.

  • PDF

A Study on Improvement of Flexibility for the Activation of the "Housing Performance Grading Indication System" (주택성능등급표시제도의 활성화를 위한 가변성 성능범주의 현황 및 개선방안연구)

  • Lee, Sung-Ok;Kim, Soo-Am
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.479-482
    • /
    • 2008
  • The purpose of this study is a proposal about the flexibility of the performance category to revitalize the "Housing Performance Grading Indication System". This system consists of 5 main performance parts, 14 performance categories and 20 detailed performance lists. 5 main performance parts are Noise and Acoustics(Light-weight impact sound control, heavy-weight impact sound control, sound control of toilet, sound control of party wall), Long-life(flexibility, remodeling & maintenance, durability), Landscape & Indoor Environment(landscape, formaldehyde control& ventilation, daylighting, thermal environment), Welfare & Barrier-free(playground and community center, welfare space, barrier-free design), Fire Safety(fire safety, safe place, fire-resisting quality). The flexibility of the performance category is conformed to Long-life housing related grading and can realize the Long-life housing in response to resident needs about the space rearrangement. Now, The flexibility of the performance category is limited to the evaluation of the private space, that is, the Skeleton evaluation. This study would suggest alternatives to improve uppermost limits through analyzing 60 examples from January 9th 2009 to October 30th 2008. The flexibility of the performance category is possible to estimate not only the Skeleton evaluation but also the Infill evaluation in response to social changes.

  • PDF

Design and Performance Evaluation of Hybrid Window Walls With Variable Transmittal Materials (투과시스템의 광학특성을 고려한 복합적 외벽채광부의 성능평가에 관한 연구)

  • Do, Jin-Seok;Kim, Gon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.4 no.2
    • /
    • pp.11-18
    • /
    • 2004
  • Growing use of entire glass facades with metal frames are popularly witnessed in modern building practices and design competition as well. In spite of architectural aesthetics and view to outdoors, environmental issues still exist in that kind of buildings. One of the solutions for the problems might be the use of functional glasses such as a heat-resistant glass or various tinted glasses for the glass walls. This paper aims to provide performance data related to the impact of various transmittal materials of window systems on the light distribution. A series of computer simulation deals with the basic geometrical and optical design elements of a commonly used all-glass facades. Additionally an experimental configuration of the vertical window is proposed for better result of daylighting. A window system equipped with an inner-light shelf can improve the uniformity of natural light in a space by reducing the level of illumination near the window and redirecting light deeply into the space.

A Correlation Analysis between DSC (Dye Sensitized Cell) and Daylighting-Focusing on Educational Space (염료감응형 태양전지(DSC)와 자연채광의 상관관계 분석-교육공간을 중심으로)

  • Lee, Eung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.1
    • /
    • pp.35-47
    • /
    • 2020
  • Due to the large window area, the lighting environment of the educational space between the window and deep part of the room is not uniformly illuminated, and the phenomenon of glare is severe. For this reason, the daylight performance of DSC-BIPV windows was analyzed in order to improve the natural lighting in the educational sector. The method derives the correlation with natural lighting by measurement and simulation. Dynamic simulation confirmed that the average illuminance of the target space was higher at later than the early afternoon. The performance of natural lighting at 40% and 30% transmission of DSC has the effect of significantly reducing the amount of excess light in existing windows. Nevertheless, the actual average illuminance in all seasons corresponds to the standard illuminance of the educational facility, 300 Lux. In addition, the uniformity is also seen through the skylight illuminance ratio.