• Title/Summary/Keyword: Daylighting Autonomy

Search Result 8, Processing Time 0.018 seconds

Evaluation of the daylight performance of adjacent interior spaces in four-sided atrium according to the height ratio of atrium, and the transmittance of atrium canopy (4면형 아트리움의 높이비와 천창 투과율에 따른 인접 실내공간의 자연채광성능 평가)

  • Yu, Ha-Nui;Lee, Ju-Yun;Song, Kyoo-Dong
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.57-62
    • /
    • 2010
  • Studies on daylighting of buildings have been continuously increased due to the recent escalating oil price and low-carbon strategies in developed countries. Daylighting of buildings not only saves electric energy, but provide the occupants with a comfort visual environment. Atrium spaces are adopted by many modern buildings to improve daylight performance of deep interior spaces. Among the various types of atria, the four-sided type atrium is frequently adopted by library buildings, governmental buildings and office buildings. This study aims to suggest daylighting design data for adjacent occupied spaces by conducting dynamic simulations using Daysim program. Daylight Factor(DF), Daylight Autonomy(DA) and Useful Daylight Illuminance(UDI) levels for 12 measurement points in adjacent occupied spaces were calculated for square-shape four-sided atria with different SAR(Section Aspect Ratio) and different canopy transmittance.

The study on the Analysis of Useful Daylight Illuminance in rural standard house model - By Dynamic Daylight Simulation Using Weather Data - (농어촌주택 표준설계의 유용조도 분석에 관한 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Yun, Young Il;Song, Jeong Suk;Lee, Hyo Won
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.47-55
    • /
    • 2011
  • Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the Rural standard house models design process, because of lack of previous studies on elderly-light environment and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. Moreover, dynamic daylight simulation were performed using whether data. Static simulation are performed to compute static metrics such as daylight factor, whereas dynamic simulation are performed for dynamic metrics such as daylight autonomy and useful daylight illuminance using annual weather data On the basis of daylight autonomy and useful daylight illuminance analysis result, variations in annual daylight performances. A parametric and regression analysis of the window-to-wall ratio and visible transmittance showed that daylight factor, daylight autonomy increased with window-to-wall ratio and visible transmittance. It can be concluded that this new daylight criteria. useful daylight illuminance, will enable architect to obtain better fenestration design.

The Study on the Analysis of Useful Daylight Illuminance in Care Facilities - By Dynamic Daylight Simulation Using Weather Data - (요양시설의 유용조도 분석에 관한 연구 -기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로-)

  • Yun, Youngil;Cho, Juyoung;Lee, Hyowon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.17 no.1
    • /
    • pp.33-40
    • /
    • 2011
  • Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the care facility design process, because of lack of previous studies on elderly- light environment and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. Moreover, dynamic daylight simulation were performed using whether data. Static simulation are performed to compute static metrics such as daylight factor, whereas dynamic simulation are performed for dynamic metrics such as daylight autonomy and useful daylight illuminance using annual weather data On the basis of daylight autonomy and useful daylight illuminance analysis result, variations in annual daylight performances. A parametric and regression analysis of the window-to-wall ratio and visible transmittance showed that daylight factor, daylight autonomy increased with window-to-wall ratio and visible transmittance. It can be concluded that this new daylight criteria. useful daylight illuminance, will enable architect to obtain better fenestration design.

Daylighting Performance based Parametric Design focused on the Office Building at the conceptual phase of BIM (설계 초기 단계 BIM 형상정보 파라메트릭 연동을 통한 오피스 실내조도 분석)

  • Park, Jung-Dae;Jo, Chan-Won;Jeon, Min-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.475-481
    • /
    • 2019
  • The importance of performance-based design feedback is being emphasized when it comes to the potential impact that affects all the lifecycle of the building. However, the latency and disconnection of domain expert in the sector of AEC/FM remain current obstacles between design and performance feedback. It is hard to utilize performance feedback information for design exploration and support design decision making during the conceptual phase of design. Using parametric design, this paper proposes various design alternatives from a set of rules and constraints defined by algorithms for the geometric configurations of an Office Building. A Building Performance Analysis (BPA) was to developed using Autodesk® Revit® 2019 which integrates Autodesk® Green Building Studio® to predict its sufficient daylighting conditions of the LEED v4's Daylighting Autonomy (DA). The parametric-based performance feedback of this study outlines potential design improvements for further exploration in application to the early design process.

Evaluation of the daylight performance of four-sided atria with various well configurations for interior vegitation growth (실내 조경 식물의 생육을 고려한 4면형 아트리움의 형태변수별 자연채광 성능평가)

  • Song, Il-Hak;Kim, Ji-Hyun;Song, Kyoo-Dong
    • KIEAE Journal
    • /
    • v.11 no.5
    • /
    • pp.137-143
    • /
    • 2011
  • An atrium space, unlike ordinary office rooms, accommodates variety of activities such as moving and resting of people and usually houses variety of vegitation to improve amenity and indoor environment. Many atrium buildings in Korea have been designed by considering the environmental criteria for human beings, not for the vegitation in the atrium space. Especially the daylighting designs are mostly focused on the required illuminances for various visual tasks of the occupants and glare controls. As a result, some atrium spaces do not provide sufficient light to the interior plants. Consequently, these atrium spaces require a high level of electric lighting to compensate the deficit of natural light for the photosynthesis of the vegitation. The purpose of this study was to suggest design guidelines for 4-sided atrium spaces having different well indices (WI), plan aspect ratio (PAR), and cardinal orientation. The findings from this study might be referenced by building designers when designing or selecting canopy systems by considering the daylight performances of the uncovered atrium spaces. In the study, the daylight performance was evaluated in terms of daylight autonomy (DA).

A Study on the Window Planning of School Building Using ECOTECT Simulation -By Dynamic Daylight Simulation Using Weather Data- (ECOTECT 시뮬레이션을 활용한 학교건축의 창호계획에 관한 연구 -기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로-)

  • Choi, Woo Ram;Han, Seok Jong;Yun, Young Il
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.77-82
    • /
    • 2013
  • Light environment in the school building is one of the most important elements of the plan in order to improve student's ability to learn and the healthy growth. Thus, the window plan of the school building is a great addition to improve environmental-friendly performance through the daylight control. Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the school building design process, because of lack of previous studies on the light environment of student and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. ECOTECT simulation were performed using weather data. As a result, ECOTECT simulation are performed for daylight autonomy and useful daylight illuminance. Using this data, Window planing is to propose and effective method in the early stages of design.

Evaluation of Daylighting Performance in Office Building with Detailed Global Illuminance Data of Selected Korean Cities (정밀 전천공조도 데이터를 활용한 국내 주요도시 업무용 건물의 자연채광 활용성능 평가)

  • Choi, Su-Hyun;Shin, Sang-Yong;Seo, Dong-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.37-46
    • /
    • 2016
  • In this study, long-term global illuminance data for 19 selected cities are calculated from modeled solar radiation data, AEER's TMY2. Perez model in Daysim daylight simulation tool is used for the solar radiation to illuminance conversion. And then, daylight availability in an unit office space is evaluated for the 19 cities. For this evaluation, various daylight performance indices are reviewed since static daylight performance index such as daylight factor (DF) and annual average global illuminance value is not suitable for actual performance evaluation in terms of visual comfort and light energy saving of a space. This study evaluated daylighting performance of prototypical office space module by introducing DA (daylight autonomy) and UDI (Useful Daylight Illuminance) index for major cities of Korea. Result shows that there is upto 18% of illuminance level difference with annual average global illuminance data, but if we consider useful daylight in a space the illuminance level difference among the cities are only within 5%. This means that for sustainable building design especially in daylight design, amount of annual global illuminance is not important factor even in cloudy cities. Daylight design and daylight harvesting system would return similar energy saving impact regardless of building location.

A study on Daylighting inducement within bedroom of Elderly care facility by light shelf attaching method for Therapeutic environment - By Dynamic Daylight Simulation Using Weather Data - (치유환경을 위한 광선반 부착방법에 따른 노인요양시설 침실 내 자연채광 유입 환경 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Cho, Ju-Young;Lee, Ki-Ho;Yun, Young-Il;Lee, Hyo-Won
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.71-79
    • /
    • 2011
  • There are high recognitions on the importance of comforts in Elderly living environment, but the circumstance is that studies on seniors facility space itself are approached only in planning level, and studies on lighting environment which is significantly associated with the comfort in the indoor environment of seniors where they actually spend the majority of their time are not that active. This study was intended to deduce cozy bedroom environment to which existing elderly care facility can be improved by using light shelf the lighting system with the advantage of being able to serve both as building sun visor and lighting window simultaneously in order to analyze the interior environment of bedroom space of elderly care facility the indoor space where the aged spend the majority of their life and examine the directions for the improvement of existing building lighting system through remodeling and renovation. In this study, lighting performance analysis was done in a way that the windows of the bedroom unit in existing facility were set in southbound direction based on two standard types and were put under initial simulation with the use of Autodesk Revit 2011, and after the simulation results were converted to Green Building Studio gbXML file to be used in ECOTECT, Daylight Autonomy a dynamic simulation and static natural lighting simulation the existing method of calculating daylight factors were deduced through Ecotect Analysis 2011. In conclusion, exiting standard model was found in such a condition that the daylight factors for both type A and type B were above 5% the proper standard value, and required improvement. In case light shelf the natural lighting system was attached, the daylight factor was improved to proper standard value for type A, and also was improved above existing facility for type B.