A Case Study for the Determination of Time Distribution of Frequency Based Rainfall (확률강우의 적정시간분포 결정에 관한 연구)
-
- Journal of Wetlands Research
- /
- v.6 no.3
- /
- pp.71-81
- /
- 2004
In recent, the heavy rainfall is frequently occurred and the damage tends to be increased. So, more careful hydrologic analysis is required for the designs of the hydraulic or disaster prevention structures. The time distribution of a rainfall is one of the important factors for the estimation of peak flow in hydrologic and hydraulic designs. This study is to suggest a methodology for the estimation of a rainfall time distribution which can reflect the meteorologic and topographical characteristics of Daejeon area. We collect the 34 years' rainfall data recorded in the range of 1969 to 2002 for Daejeon area and we performed the rainfall analysis with the data in between May and October of each year. According to the Huff method, the collected data corresponds to the first quartile which the rainfall is concentrated in the primary stage but the suggested method shows the different rainfall distribution with the Huff method in time. The reason is that the Huff method determines the quartile in each storm event while the suggested one determines it by estimating the dimensionless distribution of rainfall in duration after the accumulation of rainfall in time. The rainfall distributions estimated by two methodologies were applied to the Gabcheon basin in Daejeon area for the estimation of flood flow. Here we use the SCS method for the effective rainfall and unit hydrograph for the flood discharge. As the results, the peak flow for 24-hour of 100-year frequency was estimated as a
The effects of pectin on obesity was studied using 3T3-L1 pre-adipocytes and rats fed 20% high fat diets. The concentration of leptin released from 3T3-L1 adipocytes in the presence of pectin was significantly decreased by 85% compared to that of the control (p<0.05), however, glycerol concentration was not changed. These data indicate that pectin seems to inhibit lipids accumulation in the adipocytes rather than enhance the lipolytic activity. Forty Sprague Dawley rats were fed 20% high fat diet for 8 weeks to induce obesity and then divided equally into four groups. Experimental groups were normal diet group (ND), high fat diet group (HFD), HDF with 10% pectin group (HFP10), and HDF with 20% pectin group (HFP20). Diet for the each group was prepared to be iso-caloric following AIN-76 guideline. After obesity was induced, rats were placed on an restricted diet for 9 weeks. The body weight of HFD increased 50% (p<0.05) compared to the ND, while it was decreased by 12% and 16% for HFP10 and HFP20, respectively (p<0.05). The relative amount of visceral fats for HFDl0 and HFD20 were decreased by 45% and 59% compared to that of HDF (130%), respectively (p<0.05). Pectin seems to have a greater effect on reducing visceral fats accumulation than weight reduction. Significantly increased level of triglyceride, total cholesterol or LDL-cholesterol in the plasma of HFD was returned to the normal or even below the normal by pectin diet, while the level of HDL-cholesterol increased. Lipid lowering effect was also observed in the liver and heart. These effects of pectin were dosedependent. In conclusion, the beneficial effect of pectin on the obesity was observed from cell culture experiment and animal study in terms of inhibiting the accumulation of lipids in the adipocytes.
The purpose of this study was to obtain the basic information for the improvement of dental environment by investigating the presence of methicillin- or vancomycin-resistant Staphylococcus aureus (MRSA or VRSA) isolated from dental health care workers (DHCWs) and environment of the Chosun University Dental Hospital (CUDH) and a private dental clinic (control group). Staphylococcus aureus (S. aureus) was isolated from anterior nares of 42 DHCWS and 38 sites, unit chairss, x-ray devices, computers, etc., at 10 departments of the CUDH and 20 DHCWs and 11 sites at the private dental clinic. S. aureus was isolated on mannitol salt agar plate and confirmed by PCR with S. aureus species-specific primer. Antimicrobial susceptibility test of clinical isolates of S. aureus against several antibiotics including methicillin (oxacillin) was performed by investigating minimum inhibitory concentration (MIC) using broth microdilution assay. In addition, PCR was performed to detect the methicillin- or vancomycin-resistant gene. The data showed that one strain of S. aureus was isolated from DHCWs of the CUDH and three strains of S. aureus was isolated from 3 samples of the private dental clinic, respectively. All of the isolates from the CUDH and the private dental clinic had resistance to penicillin G, amoxicillin and vancomycin and susceptibility to oxacillin and ciprofloxacin. The S. aureus strains were already obtained the resistance to penicillin G and amoxicillin. These results suggest that two dental clinics were under relatively safe environment.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.
Purpose : Chronic renal failure is often accompanied by severe dyslipidemia, a known risk factor for cardiovascular disease. Lipoprotein(a) [Lp(a)] has recently been characterized as a risk factor for atherosclerosis and thrombosis. Cardiovascular disease is the leading cause of death in adult patients on dialysis. However, there are only limited data available concerning risk factors for atherosclerosis in uremic children. We have measured serum levels of lipids, lipoproteins, apolipoproteins and Lp(a) in uremic children with maintenance dialysis. Methods : Ten uremic children with hemodialysis (HD) and 14 with peritoneal dialysis (PD) in our dialysis unit were included in this study. The mean age of HD patients was
Purpose: The purpose of this study was to investigate the effect of different thread designs on the marginal bone stresses around dental implant. Materials and methods: Standard ITI implant(ITI Dental Implant System; Straumann AG, Waldenburg, Switzerland), 4.1 mm in diameter and 10 mm in length, was selected as control. Test implants of four different thread patterns were created based on control implant, i.e. maintaining all geometrical design of control implant except thread pattern. Four thread designs used in test implants include (1) small V-shape screw (model A), (2) large V-shape screw (model B), (3) buttress screw (model C), and (4) trapezoid screw (model D). Surface area for unit length of implant was 14.4
Purpose DMIDR(Discovery Molecular Imaging Digital Ready, General Electric Healthcare, USA) is a PET/CT scanner designed to allow application of PSF(Point Spread Function), TOF(Time of Flight) and Q.Clear algorithm. Especially, Q.Clear is a reconstruction algorithm which can overcome the limitation of OSEM(Ordered Subset Expectation Maximization) and reduce the image noise based on voxel unit. The aim of this paper is to evaluate the performance of reconstruction algorithms and optimize the algorithm combination to improve the accurate SUV(Standardized Uptake Value) measurement and lesion detectability. Materials and Methods PET phantom was filled with