• Title/Summary/Keyword: Data Acquisition Devices

Search Result 184, Processing Time 0.038 seconds

An Intelligent Bluetooth Intrusion Detection System for the Real Time Detection in Electric Vehicle Charging System (전기차 무선 충전 시스템에서 실시간 탐지를 위한 지능형 Bluetooth 침입 탐지 시스템 연구)

  • Yun, Young-Hoon;Kim, Dae-Woon;Choi, Jung-Ahn;Kang, Seung-Ho
    • Convergence Security Journal
    • /
    • v.20 no.5
    • /
    • pp.11-17
    • /
    • 2020
  • With the increase in cases of using Bluetooth devices used in the electric vehicle charging systems, security issues are also raised. Although various technical efforts have beed made to enhance security of bluetooth technology, various attack methods exist. In this paper, we propose an intelligent Bluetooth intrusion detection system based on a well-known machine learning method, Hidden Markov Model, for the purpose of detecting intelligently representative Bluetooth attack methods. The proposed approach combines packet types of H4, which is bluetooth transport layer protocol, and the transport directions of the packet firstly to represent the behavior of current traffic, and uses the temporal deployment of these combined types as the final input features for detecting attacks in real time as well as accurate detection. We construct the experimental environment for the data acquisition and analysis the performance of the proposed system against obtained data set.

A Study on the Measurement and Comparison(IEC 60079-32-2) of Flammable Liquid Conductivity (인화성 액체 도전율에 관한 측정 및 비교(IEC 60079-32-2) 연구)

  • Lee, Dong Hoon;Byeon, Junghwan
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.4
    • /
    • pp.22-31
    • /
    • 2019
  • The flammable liquid conductivity is an important factor in determining the generation of electrostatic in fire and explosion hazardous areas, so it is necessary to study the physical properties of flammable liquids. In particular, the relevant liquid conductivity in the process of handling flammable liquids in relation to the risk assessment and risk control in fire and explosion hazard areas, such as chemical plants, is classified as a main evaluation item according to the IEC standard, and it is necessary to have flammable liquid conductivity measuring devices and related data are required depending on the handling conditions of the material, such as temperature and mixing ratio for preventing the fire and explosion related to electrostatic. In addition, IEC 60079-32-2 [Explosive Atmospheres-Part 32-2 (Electrostatic hazards-Tests)] refers to the measuring device standard and the conductivity of a single substance. It was concluded that there is no measurement data according to the handling conditions such as mixing ratio of flammable liquid and temperature together with the use and measurement examples. We have developed the measurement reliability by improving the structure, material and measurement method of measuring device by referring to the IEC standard. We have developed a measurement device that is developed and manufactured by itself. The test results of flammable liquid conductivity measurement and the data of the NFPA 77 (Recommended Practice on Static Electricity) Annex B Table B.2 Static Electric Characteristic of Liquids were compared and verified by conducting the conductivity measurement of the flammable liquid handled in the fire and explosion hazardous place by using Measuring / Data Acquisition / Processing / PC Communication. It will contribute to the prevention of static electricity related disaster by taking preliminary measures for fire and explosion prevention by providing technical guidance for static electricity risk assessment and risk control through flammable liquid conductivity measurement experiment. In addition, based on the experimental results, it is possible to create a big data base by constructing electrostatic physical characteristic data of flammable liquids by process and material. Also, it is analyzed that it will contribute to the foundation composition for adding the specific information of conductivity of flammable liquid to the physical and chemical characteristics of MSDS.

A Study on Weight Estimation of Moving Vehicles using Bridge Weigh-in-Motion Technique (Bridge Weigh-in-Motion 기법을 이용한 주행차량 중량추정에 관한 연구)

  • Oh, Jun-Seok;Park, Jooyoung;Kim, Junkyeong;Park, Seunghee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.1
    • /
    • pp.29-37
    • /
    • 2015
  • In this study, the estimation of axial load and total axial load was conducted using Bridge Weigh-in-Motion(BWIM) technique which generally consists of devices for measuring the strain induced in the bridge by the vehicles. axle detectors for collecting information on vehicle velocity and axle spacing. and data acquisition equipment. Vehicle driving test for the development of the BWIM system is necessary but it needs much cost and time. In addition, it demands various driving conditions for the test. Thus, we need a numerical-simulation method for resolving the cost and time problems of vehicle driving tests, and a way of measuring bridge response according to various driving conditions. Using a bridge model reflecting the dynamic characteristic contributes to increased accuracy in numerical simulation. In this paper, we conduct a numerical simulation which reflects the dynamic characteristic of a bridge using the Bridge Weigh-in-Motion technique, and suggest overload vehicle enforcement technology.

Development of Two-color Radiation Thermometer for Harsh Environments

  • Mohammed, Mohammed Ali Alshaikh;Kim, Ki-Seong
    • Journal of ILASS-Korea
    • /
    • v.21 no.4
    • /
    • pp.184-194
    • /
    • 2016
  • Many industrial processes require reliable temperature measurements in harsh environments with high temperature, dust, humidity, and pressure. However, commercially-available conventional temperature measurement devices are not suitable for use in such conditions. This study thus proposes a reliable, durable two-color radiation thermometer (RT) for harsh environments that was developed by selecting the appropriate components, designing a suitable mechanical structure, and compensating environmental factors such as absorption by particles and gases. The two-color RT has a simple, compactly-designed probe with a well-structured data acquisition system combined with efficient LabVIEW-based code. As a result, the RT can measure the temperature in real time, ranging from 300 to $900^{\circ}C$ in extremely harsh environments, such as that above the burden zone of a blast furnace. The error in the temperature measurements taken with the proposed two-color RT compared to that obtained using K-type thermocouple readouts was within 6.1 to $1.4^{\circ}C$ at a temperature range from 200 to $700^{\circ}C$. The effects of absorption by gases including $CO_2$, CO and $H_2O$ and the scattering by fine particles were calculated to find the transmittance of the two wavelength bands of operation through the path between the measured burden surface and the two-color probe. This method is applied to determine the transmittance of the short and long wavelength bands to be 0.31 and 0.51, respectively. Accordingly, the signals that were measured were corrected, and the true burden surface temperature was calculated. The proposed two-color RT and the correction method can be applied to measure temperatures in harsh environments where light-absorbing gases and scattering particles exist and optical components can be contaminated.

Conceptual Design of PLS-II Control System for PLS (가속기 제어시스템의 성능향상을 위한 연구)

  • Yoon, J.C.;Lee, J.W.;Lee, E.H.;Ha, H.G.;Kim, J.M.;Park, S.J.;Kim, K.R.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1658_1659
    • /
    • 2009
  • PLS(Pohang Light Source) will begin the PLS-II project that has been funded by the KOREA Government in order to further upgrade the PLS which has operated since 1992. The control system of the PLS-II has distributed control architecture, with two layers of hierarchy; operator interface computer (OIC) layer and machine interface computer (MIC) layer. The OIC layer is based on SUN workstation with UNIX. A number of PC-based consoles allow to remotely operating the machine from the control room. PC-based consoles use the Linux or Windows operation system. Similar consoles in the experimental hall are used to control experiments. The MIC layer is directly interfaced to individual machine devices for low-level data acquisition and control. MIC layer is based on VMEbus standard with vxWorks real-time operating system. Executable application software modules are downloaded from host computers at the system start-up time. The MIC's and host computers are linked through Ethernet network. It should enable the use of hardware and software already developed for specific light source requirements. The core of the EPICS (Experimental Physics and Industrial Control System)[1] has been chosen as the basis for the control system software.

  • PDF

Development of an Embedded Solar Tracker using LabVIEW (LabVIEW 적용 임베디드 태양추적장치 개발)

  • Oh, Seung-Jin;Lee, Yoon-Joon;Kim, Nam-Jin;Oh, Won-Jong;Chun, Won-Gee
    • Journal of Energy Engineering
    • /
    • v.19 no.2
    • /
    • pp.128-135
    • /
    • 2010
  • This paper introduces step by step procedures for the fabrication and operation of an embedded solar tracker. The system presented consists of application software, compactRIO, C-series interface module, analogue input module, step drive, step motor, feedback devices and other accessories to support its functional stability. CompactRIO that has a real-tim processor allows the solar tracker to be a stand-alone real time system which operates automatically without any external control. An astronomical method and an optical method were used for a high-precision solar tracker. CdS sensors are used to constantly generate feedback signals to the controller, which allow a solar tracker to track the sun even under adverse conditions. The database of solar position and sunrise and sunset time was compared with those of those of the Astronomical Applications Department of the U.S. Naval Observatory. The results presented here clearly demonstrate the high-accuracy of the present system in solar tracking, which are applicable to many existing solar systems.

Development of Pulse Analysis System Based on Convenience and Compactness (사용 편의성과 소형화 기반의 맥파 측정장치 개발)

  • Cho, JungHee;Bae, JangHan;Kim, YoungMin;Jun, MinHo;Yang, TaeHeon;Jeon, YoungJu
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.168-174
    • /
    • 2017
  • To improve and downsize the KIOM-Pulse Analysis System(KIOM-PAS), which has been traditionally used in clinical trials, a miniaturized PAS(M-PAS) with a pneumatic pump has been developed. M-PAS is composed of a measurement module and an arm-mounting module, on which an arm can be placed. The measurement module is equipped with a pressing component and sensor, which is a wearable wristband. The arm-mounting module includes a pneumatic motor, data acquisition board and valves. In addition, the measurement module is divided into a fixing module of band type for attachment to a pulsation site and a sensing module, which includes a sensor and a tube. The fixing module and sensing module are constructed independently, and the detachable fastening method improves the posture convenience of the subject during measurement. M-PAS has been reduced to 1/6 the size of KIOM-PAS, and the measurement time is shortened by 22%. Using a simulator, the difference between the waveforms measured by the two devices exhibited a high degree of similarity of within 3.65%. M-PAS represents improvements in size and convenience compared with KIOM-PAS, and it is expected to be widely used in clinics in the future because it improves the attachment method of the fixing module.

Clinical Application of 3-D Compensator in Head and Neck Cancer (두경부암 환자 치료시 3차원 보상체의 임상 적용에 대한 고찰)

  • Hong, Dong-Ki;Lee, Jeong-Woo;Lee, Koo-Hyun;Park, Kwang-Ho;Kim, Jeong-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.9 no.1
    • /
    • pp.64-70
    • /
    • 1997
  • The goal of radiation treatment planning is to deliver the dose to the patient within $5\%$ of that prescribed. We have often encountered the situation that the area which have not only several irregular contours but also tissue heterogeneities should be treated. With conventional devices such as wedges, missing tissue compensator. there are some limitations to achieve the uniform dose distribution in treatment volume. The use of CT simulator, 3-D planning system, computer-controlled milling machine enables it to deliver the dose uniformally. This report includes the whole procedure which have patient data acquisition 3D planning, computer-controlled milling, performance verification of 3D compensator, and TLD evaluation. We applied it for the treatment of head and heck cancer only. In Spite of the irregular contour and different electron density of tessue, we have achieved the uniformity of the dose distribution within ${\pm}3\%$ relatively. Although there are some problems which are not only verification of performance but uncertainties of using the new treatment device, we believe that the improvement of dosimetry will eliminate the uncertainties of that application. so the other lesions besides head and neck can will be ale to use the 3D compensator to achieve the dose uniformity

  • PDF

A Study on Modified Average Filter using Standard Deviation of Local Mask in AWGN Environments (AWGN 환경에서 국부 마스크의 표준편차를 이용한 변형된 평균 필터에 관한 연구)

  • Kwon, Se-Ik;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.4
    • /
    • pp.840-846
    • /
    • 2016
  • Recently, with the rapid demand expansion on the devices of digital image processing, the excellent quality of the images is required. However, the degradation of the images occurs in the processes of data acquisition, processing, and transmission by various external causes and the noise has been well known as the major cause of image degradation. There are a variety of noises to be added on the images, with typical example of AWGN. Hence, in this article, we suggested average filter algorithm processed by the threshold values using them applying standard deviation of local mask under the AWGN environment in this study. As the result of the simulation, The proposed algorithm shows a high PSNR of 24.56[dB] for Barbara images that had been damaged of AWGN(${\sigma}=15$), compared to the existing MF, CWMF and AWMF there were improvements by 3.34[dB], 2.57[dB], and 3.32[dB], respectively.

Development of a Integrated Modifiable Micro Gas Turbine Engine Test Rig using LabVIEW (LabVIEW를 이용한 소형 가스터빈 엔진의 통합 시험장치 개발)

  • Kang, Young-Soo;Kim, Do-Hun;Lee, In-Chul;Yoon, Sang-Hoon;Koo, Ja-Ye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.354-358
    • /
    • 2009
  • Micro gas turbine engine is well known as a power plant of unmanned aerial vehicle and a small scale emergency generation system and also, it is significant as initial research of large gas turbine and educational purpose of gas turbine. Many sort of Micro gas turbine test set for education is produced by several manufacturers, but all of the engine control system of them is separated with data acquisition system; moreover, the engine control algorithms are inaccessible and related variables could not be collected. In this investigation, the Integrated Modifiable Test Rig which has modifiable engine start-up, drive and situational control logics is developed by LabVIEW with I/O devices and it provides wide experimental applicability to studies of dynamic characteristics of fuel system and combustion instability.

  • PDF