• Title/Summary/Keyword: Dark rim artifact

Search Result 3, Processing Time 0.017 seconds

Perceived Dark Rim Artifact in First-Pass Myocardial Perfusion Magnetic Resonance Imaging Due to Visual Illusion

  • Taehoon Shin;Krishna S. Nayak
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.462-470
    • /
    • 2020
  • Objective: To demonstrate that human visual illusion can contribute to sub-endocardial dark rim artifact in contrast-enhanced myocardial perfusion magnetic resonance images. Materials and Methods: Numerical phantoms were generated to simulate the first-passage of contrast agent in the heart, and rendered in conventional gray scale as well as in color scale with reduced luminance variation. Cardiac perfusion images were acquired from two healthy volunteers, and were displayed by the same gray and color scales used in the numerical study. Before and after k-space windowing, the left ventricle (LV)-myocardium boarders were analyzed visually and quantitatively through intensity profiles perpendicular the boarders. Results: k-space windowing yielded monotonically decreasing signal intensity near the LV-myocardium boarder in the phantom images, as confirmed by negative finite difference values near the board ranging -1.07 to -0.14. However, the dark band still appears, which is perceived by visual illusion. Dark rim is perceived in the in-vivo images after k-space windowing that removed the quantitative signal dip, suggesting that the perceived dark rim is a visual illusion. The perceived dark rim is stronger at peak LV enhancement than the peak myocardial enhancement, due to the larger intensity difference between LV and myocardium. In both numerical phantom and in-vivo images, the illusory dark band is not visible in the color map due to reduced luminance variation. Conclusion: Visual illusion is another potential cause of dark rim artifact in contrast-enhanced myocardial perfusion MRI as demonstrated by illusory rim perceived in the absence of quantitative intensity undershoot.

A Study on the Crime Investigation of Anonymity-Driven Blockchain Forensics (익명 네트워크 기반 블록체인 범죄 수사방안 연구)

  • Han, Chae-Rim;Kim, Hak-Kyong
    • Convergence Security Journal
    • /
    • v.23 no.5
    • /
    • pp.45-55
    • /
    • 2023
  • With the widespread use of digital devices, anonymous communication technologies such as the dark web and deep web are becoming increasingly popular for criminal activity. Because these technologies leave little local data on the device, they are difficult to track using conventional crime investigation techniques. The United States and the United Kingdom have enacted laws and developed systems to address this issue, but South Korea has not yet taken any significant steps. This paper proposes a new blockchain-based crime investigation method that uses physical memory data analysis to track the behavior of anonymous network users. The proposed method minimizes infringement of basic rights by only collecting physical memory data from the device of the suspected user and storing the tracking information on a blockchain, which is tamper-proof and transparent. The paper evaluates the effectiveness of the proposed method using a simulation environment and finds that it can track the behavior of dark website users with a residual rate of 77.2%.

Findings Regarding an Intracranial Hemorrhage on the Phase Image of a Susceptibility-Weighted Image (SWI), According to the Stage, Location, and Size

  • Lee, Yoon Jung;Lee, Song;Jang, Jinhee;Choi, Hyun Seok;Jung, So Lyung;Ahn, Kook-Jin;Kim, Bum-soo;Lee, Kang Hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.2
    • /
    • pp.107-113
    • /
    • 2015
  • Purpose: Susceptibility weighted imaging (SWI) is a new magnetic resonance technique that can exploit the magnetic susceptibility differences of various tissues. Intracranial hemorrhage (ICH) looks a dark blooming on the magnitude images of SWI. However, the pattern of ICH on phase images is not well known. The purpose of this study is to characterize hemorrhagic lesions on the phase images of SWI. Materials and Methods: We retrospectively enrolled patients with ICH, who underwent both SWI and precontrast CT, between 2012 and 2013 (n = 95). An SWI was taken, using the 3-tesla system. A phase map was generated after postprocessing. Cases with an intracranial hemorrhage were reviewed by an experienced neuroradiologist and a trainee radiologist, with 10 years and 3 years of experience, respectively. The types and stages of the hemorrhages were determined in correlation with the precontrast CT, the T1- and T2-weighted images, and the FLAIR images. The size of the hemorrhage was measured by a one- directional axis on a magnitude image of SWI. The phase values of the ICH were qualitatively evaluated: hypo-, iso-, and hyper-intensity. We summarized the imaging features of the intracranial hemorrhage on the phase map of the SWI. Results: Four types of hemorrhage are observed: subdural and epidural; subarachnoid; parenchymal hemorrhage; and microbleed. The stages of the ICH were classified into 4 groups: acute (n = 34); early subacute (n = 11); late subacute (n = 15); chronic (n = 8); stage-unknown microbleeds (n = 27). The acute and early subacute hemorrhage showed heterogeneous mixed hyper-, iso-, and hypo-signal intensity; the late subacute hemorrhage showed homogeneous hyper-intensity, and the chronic hemorrhage showed a shrunken iso-signal intensity with the hyper-signal rim. All acute subarachnoid hemorrhages showed a homogeneous hyper-signal intensity. All parenchymal hemorrhages (> 3 mm) showed a dipole artifact on the phase images; however, microbleeds of less than 3 mm showed no dipole artifact. Larger hematomas showed a heterogeneous mixture of hyper-, iso-, and hypo-signal intensities. Conclusion: The pattern of the phase value of the SWI showed difference, according to the type, stage, and size.