• Title/Summary/Keyword: Dark current

Search Result 369, Processing Time 0.023 seconds

High Performance InAIAs/InGaAs Metal-Semiconductor-Metal Photodetectors Grown by Gas Source Molecular Beam Epitaxy

  • Zhang, Y.G.;Chen, J.X.;Li, A.Z.
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.S2
    • /
    • pp.75-78
    • /
    • 1995
  • Gas source molecular beam epitaxy have been used in the growth of InAlAsAnGaAs MSM-PD structure, in which InAlAs ultra thin layer was used as Schottky barrier enhancement material. High performance MSM-PDs have been constructed on the grown wafer. High breakdown voltage of >30V, low dark current density of $3pA/\mu \textrm{cm}^2$ at 10V bias and fast transient response of <20ps rise time / <40ps FWHM have been measured, which confirm the results that GSMBE is a superior method for the growth of materials with high layer and interfacial quality, especially for InP based InAIAdInGaAs system.

  • PDF

ELECTRICAL BREAKDOWN INITIATION OF ANODIC FILMS DURING ANODIZING IN MOLTEN BISULPHATE MELT

  • Han, S.H.;Thompson, G.E.
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.3
    • /
    • pp.341-343
    • /
    • 1999
  • The morphology and composition of anodic films, formed on aluminium at various current densities, in the range $1-100{\;}Am^{-2}$, in the molten bisulphate melt at different temperatures (418-498K), have been studied using transmission electron microscopy of ultramicrotomed film sections, and ion beam thinned films. The first sign of incipient breakdown revealed by transmission electron microscopy of stripped films, is always the appearance of dark regions about 1,000 nm in diameter, representing local overgrowth of the film. The breakdown mechanism is closely related to thermal effects, because temperature rises at regions representing local overgrowth in the stripped films were observed at voltages close to the breakdown voltage, likely arising through impact ionization.

  • PDF

Spreading of a Lorentz-Gauss Vortex Beam Propagating through Oceanic Turbulence

  • Liu, Dajun;Yin, Hongming;Wang, Guiqiu;Wang, Yaochuan
    • Current Optics and Photonics
    • /
    • v.3 no.2
    • /
    • pp.97-104
    • /
    • 2019
  • Based on the extended Huygens-Fresnel principle, the analytical equation for a Lorentz-Gauss vortex beam propagating through oceanic turbulence has been derived. The spreading properties of a Lorentz-Gauss vortex beam propagating through oceanic turbulence are analyzed in detail using numerical examples. The results show that a Lorentz-Gauss vortex beam propagating through stronger oceanic turbulence will spread more rapidly, and the Lorentz-Gauss vortex beam with higher topological charge M will lose its initial dark center more slowly.

Autofluorescence Loss in Photobleaching for Human Dentin ex vivo

  • Lee, Seunghwan Goldmund;Kim, Minwoo;Jeong, Sunghee;Hwang, Jaejoon;Kim, Jisu;Gourrier, Aurelien;Vial, Jean Claude;Kyhm, Kwangseuk
    • Current Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.86-91
    • /
    • 2022
  • Two-photon fluorescence microscopy was performed on the enamel-dentin junction area of a human tooth using a femtosecond pulsed laser. We obtained a clear image contrast between the bright dentin and dark tubules with the autofluorescence generated from the endogenous fluorophores in dentin. The autofluorescence shows a broad spectrum due to complex cross links between dentinal collagens, which extend from blue to orange wavelengths (470-590 nm), but a gradual autofluorescence loss in photobleaching was observed for a long-term exposure under strong excitation. For increasing excitation power, we found that two-step decay becomes significant in the spectrally integrated autofluorescence.

Morphological and Molecular Characterization of Pseudocercospora chionanthi-retusi Causing Leaf Spot on Chionanthus retusus in Korea

  • Choi, In-Young;Abasova, Lamiya;Choi, Joon-Ho;Shin, Hyeon-Dong
    • Research in Plant Disease
    • /
    • v.28 no.2
    • /
    • pp.57-60
    • /
    • 2022
  • Leaves of Chionanthus retusus were found to be damaged by leaf spot disease associated with a fungus in Iksan, Korea. Leaf spots were angular to irregular, vein-limited, scattered, 1-8 mm diameter, brownish-gray to dark brown when dry, with heavy fructification. The pathogen causes premature defoliation of C. retusus plant and was identified as Pseudocercospora chionanthi-retusi based on morphological and molecular-phylogenetic analyses. The phylogenetic tree was constructed using multi-locus DNA sequence data of partial actin (actA), partial translation elongation factor 1-alfa (tef1), partial DNA-directed RNA polymerase II second largest subunit (rpb2) genes, and internal transcribed spacer regions. Current study provides detail morphological description of P. chionanthi-retusi on C. retusus in Korea, with supports of phylogenetic analysis and pathogenicity test.

A Deep Convolutional Neural Network approach to Large Scale Structure

  • Sabiu, Cristiano G.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.53.3-53.3
    • /
    • 2019
  • Recent work by Ravanbakhsh et al. (2017), Mathuriya et al. (2018) showed that convolutional neural networks (CNN) can be trained to predict cosmological parameters from the visual shape of the large scale structure, i.e. the filaments, clusters and voids of the cosmic density field. These preliminary works used the dark matter density field at redshift zero. We build upon these works by considering realistic mock galaxy catalogues that mimic true observations. We construct light-cones that span the redshift range appropriate for current and near future cosmological surveys such as LSST, EUCLID, WFIRST etc. In summary, we propose a novel multi-image input CNN to track the evolution in the morphology of large scale structures over cosmic time to constrain cosmology and the expansion history of the Universe.

  • PDF

A Weak-lensing Study of the Double Radio Relic Galaxy Cluster Abell 1240

  • Cho, Hyejeon;Jee, Myungkook James;Finner, Kyle
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.34.1-34.1
    • /
    • 2021
  • Abell 1240 is a merging galaxy cluster hosting prominent, symmetric double radio relics. To constrain its merging history, we provide the first weak-lensing analysis of the dark matter distribution of the Abell 1240 field with Subaru/Suprime-Cam observations after robustly addressing instrumental systematics. We also investigate the cluster galaxy distributions, combining our new MMT/Hectospec observations and the spectroscopic redshifts from the literature. Both weak-lensing mass reconstruction and galaxy distribution show that Abell 1240 consists of two subclusters stretched north to south between the double radio relics. We quantify the significance of the substructures and present their mass estimates. Finally, we discuss a merging stage of Abell 1240 with the current weak-lensing results and the radio relic priors.

  • PDF

A Study of Color Scheme on Coastal Passenger Ship Seafarer's Workspace (연안여객선 선원의 작업공간 색채계획에 관한 연구)

  • Jin Park
    • Journal of Navigation and Port Research
    • /
    • v.48 no.3
    • /
    • pp.221-231
    • /
    • 2024
  • The aim of this study was to enhance the safety and care of mental health for seafarer working in passenger ship workspaces. Brightness, color values, and color distribution were investigated with issues and improvement ways identified through seafarers' interviews. Firstly, previous studies, references, current policy, regulations, and accident case studies were reviewed. Color compositions of wheelhouse and engine room of M Ship were then surveyed in the field. Color values of each space were analyzed using a colorimeter. Colormeter analysis of brightness and color measurements in the wheelhouse and engine areas indicated that ceilings, walls, and floors were generally dark, with the engine area being very dark. Regarding color, green and blue were distributed in the ceiling of the wheelhouse and engine area, while red and blue were in the walls and floors of the wheelhouse and engine area. According to interviews with seafarers currently working at engine rooms, they responded about their experience of near miss incidents due to a decrepit indoor environment, a dark working environment, slippery and bright flooring, and stairs that were not suitable for domestic users. Thus, when installing lighting in the future, the brightness of the space should be improved by distinguishing between night and day. A lighting plan considering the location of lighting, level of shadow formation and contrast, reflectance of the facility, glare, color of light, floor color plan, and material selection is needed. A facility design suitable for domestic users is also needed.

Comparison of Electrical Signal Properties about Top Electrode Size on Photoconductor Film (광도전체 필름 상부 전극크기에 따른 전기적 신호 특성 비교)

  • Kang, Sang-Sik;Jung, Bong-Jae;Noh, Si-Cheul;Cho, Chang-Hoon;Yoon, Ju-Sun;Jeon, Sung-Pyo;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.93-96
    • /
    • 2011
  • Currently, the development of direct conversion radiation detector using photoconductor materials is progressing in widely. Among of theses photoconductor materials, mercuric iodide compound than amorphous selenium has excellent absorption and sensitivity of high energy radiation. Also, the detection efficiency of signal generated in photoconductor film varies by electric filed and geometric distribution according to top-bottom electrode size. Therefore, in this work, the x-ray detection characteristics are investigated about the size of top electrode in $HgI_2$ photoconductor film. For sample fabrication, to solve the problem that is difficult to make a large area film, we used the spatial paste screen-print method. And the sample thickness is $150{\mu}m$ and an film area size is $3cm{\times}3cm$ on ITO-coated glass substrate. ITO(Indium-Tin-Oxide) electrode was used as top electrode using a magnetron sputtering system and each area is $3cm{\times}3cm$, $2cm{\times}2cm$ and $1cm{\times}1cm$. From experimental measurement, the dark current, sensitivity and SNR of the $HgI_2$ film are obtained from I-V test. From the experimental results, it shows that the sensitivity increases in accordance with the area of the electrode but the SNR is decreased because of the high dark current. Therefore, the optimized size of electrode is importance for the development of photoconductor based x-ray imaging detector.

Characterization of New Avalanche Photodiode Arrays for Positron Emission Tomography

  • Song, Tae-Yong;Park, Yong;Chung, Yong-Hyun;Jung, Jin-Ho;Jeong, Myung-Hwan;Min, Byung-Jun;Hong, Key-Jo;Choe, Yearn-Seong;Lee, Kyung-Han
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.45-45
    • /
    • 2003
  • The aim of this study was the characterization and performance validation of new prototype avalanche photodiode (APD) arrays for positron emission tomography (PET). Two different APD array prototypes (noted A and B) developed by Radiation Monitoring Device (RMD) have been investigated. Principal characteristics of the two APD array were measured and compared. In order to characterize and evaluate the APD performance, capacitance, doping concentration, quantum efficiency, gain and dark current were measured. The doping concentration that shows the impurity distribution within an APD pixel as a function of depth was derived from the relationship between capacitance and bias voltage. Quantum efficiency was measured using a mercury vapor light source and a monochromator used to select a wavelength within the range of 300 to 700 nm. Quantum efficiency measurements were done at 500 V, for which the APD gain is equal to one. For the gain measurements, a pencil beam with 450 nm in wavelength was illuminating the center of each pixel. The APD dark currents were measured as a function of gain and bias. A linear fitting method was used to determine the value of surface and bulk leakage currents. Mean quantum efficiencies measured at 400 and 450 nm were 0.41 and 0.54, for array A, and 0.50 and 0.65 for array B. Mean gain at a bias voltage of 1700 V, was 617.6 for array A and 515.7 for type B. The values based on linear fitting were 0.08${\pm}$0.02 nA 38.40${\pm}$6.26 nA, 0.08${\pm}$0.0l nA 36.87${\pm}$5.19 nA, and 0.05${\pm}$0.00 nA, 21.80${\pm}$1.30 nA in bulk surface leakage current for array A and B respectively. Results of characterization demonstrate the importance of performance measurement validating the capability of APD array as the detector for PET imaging.

  • PDF