• Title/Summary/Keyword: Damper Control System

Search Result 701, Processing Time 0.025 seconds

Characteristics of Filters for Signal Processing Applied to Wind Turbine Controllers (풍력발전 제어에 적용되는 계측신호처리 필터에 대한 특성 고찰)

  • Moon, Seok-Jun;Shin, Yun-Ho;Chung, Tae-Young;Rim, Chae-Whan;Ryu, Ji-Yune
    • New & Renewable Energy
    • /
    • v.7 no.4
    • /
    • pp.58-65
    • /
    • 2011
  • In variable-speed variable-pitch wind turbines, the conventional approach for controlling power-production operation relies on a generator-torque controller and a rotor-collective blade-pitch controller. Both controllers use the generator speed measurement as the sole feedback input. In order to mitigate unwanted excitation of the control system, many filters are adopted. In this study, the characteristics of some filters for signal processing are investigated based on frequency response function. They include low-pass filters, band-pass filters, and notch filters. Especially, this study focuses on design parameters of their filters.

Electromagnetic Design and Performance Evaluation of an MR valve (MR 밸브의 전자기적 설계와 성능 평가)

  • Kim, Ki-Han;Nam, Yun-Joo;Park, Myeong-Kwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.968-973
    • /
    • 2007
  • This paper presents an electromagnetic design for the magneto-rheological fluid valve. The MR valve can control high-level fluid power without moving parts, due to the apparent viscosity controllability of the MR fluid in magnetic fields. In order to improve the static characteristic of the MR valve, the length of the flux path is decreased by removing the unnecessary bulk of the yoke. Then, in order to improve the dynamic and hysteretic characteristics, the magnetic reluctance of the ferromagnetic material is increased by minimizing the cross sectional area through which the flux passes. Two MR valves, one is a conventional type valve and the other is the proposed one, were fabricated and performance evaluation is experimentally achieved through the comparison study using by-pass damper system.

  • PDF

Dynamics Modeling of Beams with Shunted Piezoelectric Elements (압전 공진 션트회로가 부착된 빔의 동적 모델링)

  • Park, Chul-H.;Park, Hyun-C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.228-233
    • /
    • 2002
  • General modeling of a resonant shunting damper has been made from piezoelectric sensor/actuator equation. It is found that an additional damping, which is augmented to a system, is generated by the shunt damping effect. The transfer function of the tuned electrical absorber is derived for both series and parallel shunt circuit. The governing equations and associated boundary conditions are derived using Hamilton's Principle. The shunt voltage equation is also derived from the charge generated in PZT due to beam vibration. The frequency response function of the obtained mathematical model is compared with that of the tuned electrical absorber and experimental work. The vibration amplitude is reduced about 15 dB at targeted second mode frequency.

  • PDF

Dynamics Modeling of Beams with Piezoelectric Resonant Shunting (압전 공진 션트회로가 부착된 빔의 동적 모델링)

  • Park Cheol Hyu;Park Hyeon Cheol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.328.2-328
    • /
    • 2002
  • General modeling of a resonant shunting damper has been made Iron piezoelectric sensor/actuator equation. It is found that an additional damping, which is augmented to a system, is generated by the shunt damping effect The transfer function of the tuned electrical absorber is derived for both series and parallel shunt circuit. The governing equations and associated boundary conditions are derived using Hamilton's Principle. The shunt voltage equation is also derived from the charge generated in PZT due to beam vibration. The frequency response function of the obtained mathematical model is compared with that of the tuned eledtrical absorber and experimental work. The vibration amplitude is reduced about 15 dB at targeted second mode frequency.

  • PDF

Response Property of Multi-directional Mount Using Magneto-Rheological Fluid (MR유체를 이용한 다방향 제진형 마운트의 응답특성)

  • 안영공;신동춘;양보석;이일영;김동조
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.7
    • /
    • pp.517-523
    • /
    • 2003
  • This paper presents response property of the squeeze mode type mount using Magneto-Rheological fluid (MR fluid) . The MR mount for the isolation of multi-directional vibrations was constructed in this study. Both the mechanism and shape of the mount are the same as squeeze film dampers for a rotor system. In the present work, the performance of the mount was experimentally Investigated according to the magnetic field strength. The experimental results present that the MR mount can effectively reduce the vibration in a wide range of frequency by controlling the applied electromagnetic filed strength. Viscous damping and stiffness coefficients of the MR mount tend to be changed according to the variation of the applied currents In this study.

Characteristics of Filters for Signal Processing Applied to Wind Turbine Controllers (풍력발전 제어에 적용되는 계측신호처리 필터에 대한 특성 고찰)

  • Moon, Seokjun;Shin, Yunho;Chung, Taeyoung;Rim, Chaewhan;Ryu, Jiyune
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.36.2-36.2
    • /
    • 2011
  • In variable-speed variable-pitch wind turbines, the conventional approach for controlling power-production operation relies on a generator-torque controller and a rotor-collective blade-pitch controller. Both controllers use the generator speed measurement as the sole feedback input. In order to mitigate unwanted excitation of the control system, many filters are adopted. In this study, the characteristics of some filters for signal processing are investigated based on frequency response function. They include low-pass filters, band-pass filters, and notch filters. Especially, this study focuses on design parameters of their filters.

  • PDF

Improvement of aeroelastic stability of hingeless helicopter rotor blade by passive piezoelectric damping

  • Yun, Chul-Yong;Kim, Seung-Jo
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.7 no.1
    • /
    • pp.54-64
    • /
    • 2006
  • To augment weakly damped lag mode stability of a hingeless helicopter rotor blade in hover, piezoelectric shunt with a resistor and an inductor circuits for passive damping has been studied. A shunted piezoceramics bonded to a flexure of rotor blade converts mechanical strain energy to electrical charge energy which is dissipated through the resistor in the R-L series shunt circuit. Because the fundamental lag mode frequency of a soft-in-plane hingeless helicopter rotor blade is generally about 0.7/rev, the design frequency of the blade system with flexure sets to be so. Experimentally, the measured lag mode frequency is 0.7227/rev under the short circuit condition. Therefore the suppression mode of this passive damping vibration absorber is adjusted to 0.7227/rev. As a result of damping enhancement using passive control, the passive damper which consists of a piezoelectric material and shunt circuits has a stabilizing effect on inherently weakly damped lag mode of the rotor blades, at the optimum tuning and resistor condition.

A Controller Design for Semi-active Suspension System Using Wavelet Treasform and Evolution Strategy (웨이브릿 변환과 진화전략에 의한 반능동 현가장치의 제어기 설계)

  • Kim, Dae-Jun;Kim, Han-Soo;Jeon, Hyang-Sig;Choi, Young-Kiu;Kim, Sung-Shin
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.3
    • /
    • pp.120-129
    • /
    • 2001
  • A two-degree-of-freedom quarter-car model is used as the basis for LQ and the proposed controller design for a semi-active suspension. The LQ controller results in the best rms performance trade-offs(as defined by performance index) between ride, handling and packaging requirements. In LQ controller, however, the conflict between road holding and ride comfort remains. The adaptive semi-active suspension control based on the road frequency are introduced in this paper. With this method, the trade-off between road holding and ride comfort can be relaxed. The road frequency is estimated by wavelet transform if rattle space signal. The simulation results show that the proposed controller is superior to the conventional LQ controller.

  • PDF

A Development of Active Controller for the Vibration of Tall Civil St (고층 빌딩의 진동에 대한 능동제어기의 개발)

  • Lee, Y.J.;Chang, Y.H.;Song, B.M.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.689-692
    • /
    • 1997
  • This paper is attempt to develop an active controller for the vibration of tall civil structures due to earthquake-induced ground acceleration. Various active control methods are applied to an 8 story base isolated system(BIS) with a fumed mass damper(TMD) at the base of the building. The results are also investigated.

  • PDF

Dynamic Analysis of the Valves installed in the swash plate type of Hydraulic Driving Motor (사판식 구동 모터에 장착된 밸브의 동적거동 해석)

  • Noh, D.K.;Jang, J.S.
    • Journal of Drive and Control
    • /
    • v.9 no.4
    • /
    • pp.62-69
    • /
    • 2012
  • Recently, hydraulic motor is getting the spotlight. It is resulted from rapid civil engineering public works by a lot of developing countries around the world. In this study, we divided the valves which are affixed in the hydraulic motor into some parts, implemented them through computer simulation, verified validation of each component, and analyzed behavior adding driving condition. Through the analyzed results with general driving condition, we found the reason why behavior became unstable as the motor had started spinning. Through the analyzed results with tough driving condition, we verified that the valve works well with it's production purpose.