• Title/Summary/Keyword: Damage-controlled System

Search Result 107, Processing Time 0.03 seconds

The Review of Functional Electrical Stimulation (기능적 전기자극에 대한 고찰)

  • Park, Kyu-Hyun;Kim, Sun-Kyoo;Chung, Hyun-Ae;Park, Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.2
    • /
    • pp.399-405
    • /
    • 2001
  • Attainment of the goals of functional electrical stimulation(FES) applications such as strengthening of muscle, increasing muscular endurance, improvement in joint range of motion or the reduction of spasticity does not insure that patients will be able to produce voluntary muscle contraction sufficient to maintain posture or produce purposeful movements. In many patients who have sustained CNS damage, the control exerted by higher nervous system center over muscle contraction may impaired. In Searched patients, a variety of advanced therapeutic exercise techniques have been employed traditionally to facilitate the return of controlled functional muscular activity or maintain postural alignment until recovery from dysfunction occurs Among the most common clinical applications of FES for functional muscle contraction is as a substitute for static or dynamic orthotic devices

  • PDF

Vehicle Voltage Stabilizing Module Using Supercapacitors (슈퍼캐패시터를 이용한 자동차 전압 안정화 모듈)

  • Park, Sukhee;Jeong, Kyuwon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.1
    • /
    • pp.124-129
    • /
    • 2015
  • The performance of a passenger vehicle has been greatly improved recently owing to the intensive use of electronic controllers. Many components of a vehicle, including the engine, are controlled by electronic systems installed in the vehicle. Therefore, the electrical power required for such electronics has increased significantly. However, the electrical power generated by the vehicle's alternator, operated by the engine, is limited, and when the vehicle is started, a large instantaneous current is required. The voltage of the vehicle electrical system fluctuates to a very low level, then, it is gradually recovered. This case is very severe and can even cause damage to electronic systems. In this study, a voltage-stabilizing module comprising electric double layer supercapacitors, which could alleviate the voltage variation, was developed and tested.

Analysis of Natural Periods of Sloshing and Control of Sloshing Effect for a Launch Vehicle (슬로싱 고유주기 해석 및 발사체의 슬로싱 효과 제어)

  • 김동현;최재원
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.201-201
    • /
    • 2000
  • Recently in the design of fuel tanks(launch vehicle, ship, automobile) which transport a large amount of liquid in the cargo holds, the structural damage due to liquid-sloshing becomes an important problem. The impact pressure from sloshing is most violent when the liquid motion of a partially filled tank is in resonance with the motion of a system. In this paper, the sloshing natural periods in liquid tanks are estimated for partially filled tanks with various geometries. In addition to, controlled for a launch vehicle with liquid sloshing effect by PD controller and sloshing filter The PD gain and sloshing filter parameter arc determined by optimal algorithm.

  • PDF

Review Criteria for Reliability from Analysis of LOOP frequency in NPPs (소외전원상실사고 빈도수 분석을 통한 원전 신뢰도 검토기준)

  • Moon, Su-Cheol;Kim, Kern-Joong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.3
    • /
    • pp.300-305
    • /
    • 2013
  • LOOP(Loss of Offsite Power) and SBO(Station Blackout) events have been occurring in nuclear power plants should be reviewed and be controlled on important electrical equipments by professional engineer to prevent and to safety improvement from safety assessment and reliability analysis report. LOOP and SBO occasionally happened by internal or external causes. This paper contained that LOOP frequency in the United States NPPs and in the domestic NPPs have compared and analyzed data by the past lessons and probabilistic statistics. Additionally will be installed MG(Mobile Generator) according to the lessons of Fukushima nuclear accident in Japan, which CDF(Core Damage Frequency) and LOOP frequency have reconsidered. And this paper proposed to reduce reliability criteria using PSA(Probabilistic Safety Analysis).

Microprocessor Based Permanent Magnet Synchronous Motor Drive (마이크로 프로세서에 의한 영구자석동기 전동기의 구동)

  • Yoon, Byung-Do
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.12
    • /
    • pp.541-554
    • /
    • 1986
  • This paper presents the results of driving performance analysis of permanent magnet synchronous motor using a microprocessor based control system. The system consists of three phase power transistor inverters, three phase controlled rectifier, three central processing units, and sensors. The three CPUs are, respectively, used to generate PWM control signals for the inverter generating three phase sine wave, to generate the gate control signals for firing the converter, and to supervise other two CPUs. The supervisor is used to compute PI control algtorithm to three phase reference sine wave for the inverter. It is also used to maintain a constant voltage frequency ratio for the converter operating as a constant torque controller. The inverter CPU retrieves precomputed PWM patterns from look up tables because of computation speed limitations found in almost available microprocessors. The converter CPU also retrieves precomputed gate control patterns from another look-up tables. For protecting the control ststem from any damage by extraordinary over currents, the supervisor receives the data from current sensor, CT, and break down the CB to isolate the circuits from source. A resolver has a good performance characteristics of overall speed range, especially on low speed range. Therefor the speed control accuracy is impoved. The microprocessor based PM synchronous motor control system, thus, has many advantages such as constant torque characteristics, improvement of wave, limitation on extraordinary over currents, improvement of speed control accuracy, and fast response speed control using multi-CPU and look-up tables.

  • PDF

A Study on Risk Assessment Model for Occupational Health and Safety Management System - Focused on Organization Using Chemical Material - (안전보건경영시스템 구축을 위한 위험성평가모델에 대한 연구 - 화학물질 사용조직을 중심으로 -)

  • Cho, Kyeong-Seok;Lee, Chang-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.1-9
    • /
    • 2014
  • The occupational health and safety accidents were continuously increased during handling, usage and manufacturing the chemical materials according to increase of small and medium sized enterprises in domestic industries. These accidents mainly resulted from insufficient occupational health and safety management and deteriorative facilities and focused on corresponding operation to minimize the damage of accidents after occurrence. But, it was required that we grasped the occurrence causes of occupational health and safety risk in handling, usage and manufacturing the chemical materials and develop the adequate corresponding operation and system according to the possible occurrence of occupational health and safety risk. This study deals with the development of risk assessment model to derive the risk and important risk of occupational health and safety and then help to construct the self-controlled occupational health and safety system for small and medium sized enterprises handling the chemical materials.

Seismic Capacity Evaluation of Low-Rise Reinforced Concrete Buildings in Korea (국내 저층 철근콘크리트 건물의 내진성능 평가)

  • Lee, Kang-Seok;Kim, Yong-In;Min, Kyung-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.241-244
    • /
    • 2008
  • The authors proposed a new rapid-screening method for more reasonably evaluating seismic capacities of medium and low-rise RC buildings controlled by both shear and flexure in Ref. [1]. The method proposed in Ref. [1] was based on relationships between required strengths of each failure system for ductility factors and damage degrees of overall system derived from the view-point of ductility factors. The proposed method was also verified using observed real damage data of low-rise RC buildings caused by past earthquakes. Results indicated that the methodology proposed in Ref. [1] compares well with real damages and is a useful strategy for rapidly identifying low-rise RC buildings having high potential seismic risk. In this study, in order to verify the applicability of the new methodology proposed in Ref. [1] to real RC building systems, seismic capacities of existing eleven low-rise RC buildings in Korea are evaluated based on the new method.

  • PDF

Semi-active storey isolation system employing MRE isolator with parameter identification based on NSGA-II with DCD

  • Gu, Xiaoyu;Yu, Yang;Li, Jianchun;Li, Yancheng;Alamdari, Mehrisadat Makki
    • Earthquakes and Structures
    • /
    • v.11 no.6
    • /
    • pp.1101-1121
    • /
    • 2016
  • Base isolation, one of the popular seismic protection approaches proven to be effective in practical applications, has been widely applied worldwide during the past few decades. As the techniques mature, it has been recognised that, the biggest issue faced in base isolation technique is the challenge of great base displacement demand, which leads to the potential of overturning of the structure, instability and permanent damage of the isolators. Meanwhile, drain, ventilation and regular maintenance at the base isolation level are quite difficult and rather time- and fund- consuming, especially in the highly populated areas. To address these challenges, a number of efforts have been dedicated to propose new isolation systems, including segmental building, additional storey isolation (ASI) and mid-storey isolation system, etc. However, such techniques have their own flaws, among which whipping effect is the most obvious one. Moreover, due to their inherent passive nature, all these techniques, including traditional base isolation system, show incapability to cope with the unpredictable and diverse nature of earthquakes. The solution for the aforementioned challenge is to develop an innovative vibration isolation system to realise variable structural stiffness to maximise the adaptability and controllability of the system. Recently, advances on the development of an adaptive magneto-rheological elastomer (MRE) vibration isolator has enlightened the development of adaptive base isolation systems due to its ability to alter stiffness by changing applied electrical current. In this study, an innovative semi-active storey isolation system inserting such novel MRE isolators between each floor is proposed. The stiffness of each level in the proposed isolation system can thus be changed according to characteristics of the MRE isolators. Non-dominated sorting genetic algorithm type II (NSGA-II) with dynamic crowding distance (DCD) is utilised for the optimisation of the parameters at isolation level in the system. Extensive comparative simulation studies have been conducted using 5-storey benchmark model to evaluate the performance of the proposed isolation system under different earthquake excitations. Simulation results compare the seismic responses of bare building, building with passive controlled MRE base isolation system, building with passive-controlled MRE storey isolation system and building with optimised storey isolation system.

Development of a Water-Spraying Type Automatic Glochids Removal System for Cactus (Opuntia humifusa) Stem

  • Jang, Ik Joo;Park, Tusan;Ha, Yu Shin
    • Journal of Biosystems Engineering
    • /
    • v.41 no.3
    • /
    • pp.201-207
    • /
    • 2016
  • Purpose: A water-spraying type automatic glochids removal system for cactus (Opuntia humifusa) stem was developed, and its performance was evaluated. The system was developed to reduce intensive human labor in removing glochids from cactus stem skin without inducing damage prior to further processing into value-added products. Methods: The developed system consists of conveyor and water-spraying systems. The conveyor system delivers cactus stems through water-spraying compartments and finally to a collecting box. In order to remove the glochids, rotating nozzles spray water over all areas (i.e., front and back faces and sides) of the cactus skin under controlled water pressure. Operating conditions such as conveyor speed, water pressure, angle of water-spraying nozzles, distance between conveyor belt and rotating nozzles, and angle of cactus flipping slide were adopted from our previous study and applied on the system design and manufacturing. The performance of glochids removal was evaluated by counting the number of glochids on the cactus stem before and after processing on the system. Results: The developed system performed efficiently and effectively under the pre-studied operating conditions except for the angle of cactus flipping slide. The new system had a glochids removal ratio of 94.1% without damaging the cactus skin. Considering the original number (approximately 30-60) of glochids, the remaining number was low (1-4), and most of them were found at the side edge of the cactus stem. This system can remove glochids from 360 cactus stems in 1 hr regardless of cactus size. Conclusions: The performance of the new system in glochids removal without damaging cactus skin is superior to any other existing device (i.e., brush type, rubber-friction type, and agitation type). The system is expected to be applied in cactus (O. humifusa) processing facilities.

Application of simple adaptive control to an MR damper-based control system for seismically excited nonlinear buildings

  • Javanbakht, Majd;Amini, Fereidoun
    • Smart Structures and Systems
    • /
    • v.18 no.6
    • /
    • pp.1251-1267
    • /
    • 2016
  • In this paper, Simple Adaptive Control (SAC) is used to enhance the seismic response of nonlinear tall buildings based on acceleration feedback. Semi-active MR dampers are employed as control actuator due to their reliability and well-known dynamic models. Acceleration feedback is used because of availability, cost-efficiency and reliable measurements of acceleration sensors. However, using acceleration feedback in the control loop causes the structure not to apparently meet some requirements of the SAC algorithm. In addition to defining an appropriate SAC reference model and using inherently stable MR dampers, a modification in the original structure of the SAC is proposed in order to improve its adaptability to the situation in which the plant does not satisfy the algorithm's stability requirements. To investigate the performance of the developed control system, a numerical study is conducted on the benchmark 20-story nonlinear building and the responses of the SAC-controlled structure are compared to an $H_2/LQG$ clipped-optimal controller under the effect of different seismic excitations. As indicated by the results, SAC controller effectively reduces the story drifts and hence the seismically-induced damage throughout the structural members despite its simplicity, independence of structural parameters and while using fewer number of dampers in contrast with the $H_2/LQG$ clipped-optimal controller.