• Title/Summary/Keyword: Damage Magnitude

Search Result 336, Processing Time 0.024 seconds

A Study on the Deduction of performance Point of Nonseismically Designed Reinforced Concrete Apartment (비내진 설계된 철근콘크리트 아파트의 성능점 도출에 관한 연구)

  • Kwon, Ki-Hyuk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.4 s.19
    • /
    • pp.85-93
    • /
    • 2005
  • It has been commonly assumed that during the 21st century, the korean peninsula may suffer huge earthquake damage to people, society, and economic system. The recent report of "Seoul Earthquake Response model development" conducted by the city of Seoul indicated that a magnitude 6.3 earthquake possibly hit Seoul, the capital of Korea. However, due to the insufficient amount of study on seismic performance of structures reflecting the various types of element peculiar to Korea application of the currently available earthquake damage evaluation methods has limitations. In order to conduct various studies on seismic hazards that are suitable for the actual conditions in Korea, therefore, fundamental studies first have to be properly conducted. The purpose of this study is to serve as the basis of establishing a reliable earthquake damage estimation system, and to provide essential data for the seismic damage evaluation of nonseismically reinforced concrete apartment structures. In this study, a standard type of nonseismically reinforced concrete apartments has been determined based on an extensive survey and careful review of such structures in Korea, and their performance level on seismic loading has been estimated.

Smart sensors for monitoring crack growth under fatigue loading conditions

  • Giurgiutiu, Victor;Xu, Buli;Chao, Yuh;Liu, Shu;Gaddam, Rishi
    • Smart Structures and Systems
    • /
    • v.2 no.2
    • /
    • pp.101-113
    • /
    • 2006
  • Structural health monitoring results obtained with the electro-mechanical (E/M) impedance techniqueand Lamb wave transmission methods during fatigue crack propagation of an Arcan specimen instrumented with piezoelectric wafer active sensors (PWAS) are presented. The specimen was subjected in mixed-mode fatigue loading and a crack was propagated in stages. At each stage, an image of the crack and the location of the crack tip were recorded and the PWAS readings were taken. Hence, the crack-growth in the specimen could be correlated with the PWAS readings. The E/M impedance signature was recorded in the 100 - 500 kHz frequency range. The Lamb-wave transmission method used the pitch-catch approach with a 3-count sine tone burst of 474 kHz transmitted and received between various PWAS pairs. Fatigue loading was applied to initiate and propagate the crack damage of controlled magnitude. As damage progressed, the E/M impedance signatures and the waveforms received by receivers were recorded at predetermined intervals and compared. Data analysis indicated that both the E/M impedance signatures and the Lamb-wave transmission signatures are modified by the crack progression. Damage index values were observed to increase as the crack damage increases. These experiments demonstrated that the use of PWAS in conjunction with the E/M impedance and the Lamb-wave transmission is a potentially powerful tool for crack damage detection and monitoring in structural elements.

Damage Analysis of Meteorological Disasters for Each District Considering the Characteristics of a District (지자체별 특성을 고려한 자연재해에 따른 피해유형 분석)

  • Jun, Hwan-Don;Park, Moo-Jong;Kim, Guen-Young
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.2
    • /
    • pp.75-82
    • /
    • 2008
  • Heavy rains and typhoons are the most critical meteorological disaster occurred in the Korean peninsular. Due to the global warming, the magnitude of heavy rains and typhoons is becoming heavier resulting in more damage annually. Therefore, it is required to establish a mitigation plan to reduce the damage from meteorological disasters. To do so, in general, it is better to establish a mitigation plan for each district considering the characteristics of a district than a single mitigation plan for the entire districts without considering the characteristics of an individual district. In this study, we provide fundamental data for establishing a mitigation plan from analysis considering the frequency and damage in monetary value by heavy rain and typhoon with the geological and social characteristics of districts. The annual damage reports published by the National Emergency Management Agency, dated from 1994 to 2003, are used for the analysis. The districts are classified into six categories by the geological and social characteristics. Also, the frequency and damage in monetary value are assessed for each district. Based on them, the damage degree by heavy rain and typhoon from 1st to 4th is assigned to each district. The assigned damage degree is, then, analyzed with geological and social characteristics of each district to show the status of damage by meteorological disasters on the district.

Oilspill Damage Assessment of Natural Fisheries Resources by Ecological Models (생태학적 모델을 이용한 유류유출 사고에 의한 자연 수산자원 피해의 추정)

  • YOO Sin jae;SHIN Kyoung Soon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.29 no.2
    • /
    • pp.174-190
    • /
    • 1996
  • Damage assessment based on in situ surveys for oil spills in marine environment is limited by fundamental difficulties as well as tremendous expenses. Except for intertidal zones, the damage is not preserved well. Also such surveys are usually confined to adult organisms. To overcome these limitations a computer model, NRDAM/CME, was developed in the case of USA (Reed et al., 1989), where an acute toxicity data base was used to assess indirect damages through food webs and loss due to recruitment as well as adult losses. In the present study damage assessment of natural biological resources for hypothetical oil spills is attempted using a computer model for hypothetical spills of Bunker C and heavy crude oil. In the model, the logical structure of NRDAM/CME was adopted, and biomass and productivity database were compiled for the Korean waters. The results showed that the damage increased in a nonlinear fashion as the spill amount increased. The magnitude of the damage depended upon the chemical properties of oil viscosity and solubility in particular, which implies that usage of oil dispersant might increase the damage by dispersing oil. The results also indicate that long term damage due to recruitment loss could be greater than short term damage.

  • PDF

A comprehensive approach to flow-based seismic risk analysis of water transmission network

  • Yoon, Sungsik;Lee, Young-Joo;Jung, Hyung-Jo
    • Structural Engineering and Mechanics
    • /
    • v.73 no.3
    • /
    • pp.339-351
    • /
    • 2020
  • Earthquakes are natural disasters that cause serious social disruptions and economic losses. In particular, they have a significant impact on critical lifeline infrastructure such as urban water transmission networks. Therefore, it is important to predict network performance and provide an alternative that minimizes the damage by considering the factors affecting lifeline structures. This paper proposes a probabilistic reliability approach for post-hazard flow analysis of a water transmission network according to earthquake magnitude, pipeline deterioration, and interdependency between pumping plants and 154 kV substations. The model is composed of the following three phases: (1) generation of input ground motion considering spatial correlation, (2) updating the revised nodal demands, and (3) calculation of available nodal demands. Accordingly, a computer code was developed to perform the hydraulic analysis and numerical modelling of water facilities. For numerical simulation, an actual water transmission network was considered and the epicenter was determined from historical earthquake data. To evaluate the network performance, flow-based performance indicators such as system serviceability, nodal serviceability, and mean normal status rate were introduced. The results from the proposed approach quantitatively show that the water network is significantly affected by not only the magnitude of the earthquake but the interdependency and pipeline deterioration.

A Study on Fireproofing Application by Fire Magnitude (화재규모에 따른 화학공장의 내화구조 적용에 대한 연구)

  • Lee, Dong Hyeok;Yoo, Byung Tae
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.46-52
    • /
    • 2018
  • Interest in fire prevention/fighting has been increased by large fire. It is important to install/manage the detector, alarm, firefighting facility, evacuation route and so on to minimize the damage from fire. Chemical plant is generally constructed by steel structure. So fireproofing is significantly required to chemical plant because steel structure should endure during fire. Currently, fireproofing should be applied up to 6m from ground by local regulation. But chemical plant can handle the large amount of flammable materials or only non-flammable materials. Required of fireproofing height by fire magnitude is studied in this thesis.

Initial Second Harmonic Generation in Narrowband Surface Waves by Multi-Line Laser Beams for Two Kinds of Spatial Energy Profile Models: Gaussian and Square-Like

  • Choi, Sungho;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.3
    • /
    • pp.257-263
    • /
    • 2013
  • Acoustic nonlinearity of surface waves is an effective method to evaluate the micro damage on the surface of materials. In this method, the $A_1$ (magnitude of the fundamental wave) and $A_2$ (magnitude of the second-order harmonic wave) are measured for evaluation of acoustic nonlinearity. However, if there is another source of second-order harmonic wave other than the material itself, the linear relationship between $A_1{^2}$ and $A_2$ will not be guaranteed. Therefore, the second-order harmonic generation by another source should be fully suppressed. In this paper, we investigated the initial second-order harmonic generation in narrowband surface waves by multi-line laser beams. The spatial profile of laser beam was considered in the cases of Gaussian and square-like. The temporal profile was assumed to be Gaussian. In case of Gaussian spatial profile, the generation of the initial second-order harmonic wave was inevitable. However, when the spatial profile was square-like, the generation of the initial second-order harmonic wave was able to be fully suppressed at specific duty ratio. These results mean that the multi-line laser beams of square-like profile with a proper duty ratio are useful to evaluate the acoustic nonlinearity of the generated surface waves.

Development of Vibration Absorption Device for the Transportation-Trailer System (IV) - Connecting Hitch, Leaf Spring and Shock Absorber Suspension - (수송 트레일러의 충격흡수장치 개발 (IV) - 동력경운기 적재함의 연결히치, 판스프링, 쇽업쇼바 -)

  • Hong, Jong Ho;Wu, Yong Gen
    • Journal of Biosystems Engineering
    • /
    • v.37 no.6
    • /
    • pp.359-364
    • /
    • 2012
  • Purpose: This study was conducted to analyze the vibration absorption effect for the agricultural product transportation-trailer equipped with vibration absorbable connecting hitch, leaf spring suspension, and shock absorber simultaneously (HLS), comparing with the trailer equipped with vibration absorbable connecting hitch only(H), trailer equipped with connecting hitch and leaf spring suspension (HL), and existing trailer with no vibration absorption device (E). Methods: Vertical accelerations were measured at driver seat and front, middle, rear parts of trailer bottom with no load for 4 types of transportation-trailer, and analyzed using FFT analyzer. Results: The magnitude of average vibration accelerations occurred up to 20 Hz, at this low frequencies the severe damage for agricultural products could be represented, was lower (maximum 6 times) for HLS trailer compared with H trailer. And vibration absorption effect for HLS trailer was also higher up to 40-80 Hz and 80-100 Hz, but the difference was less. At driver seat, the vibration absorption effect was high severely for HL and HLS trailer, and the magnitude of vibration acceleration was showed less difference in comparing at trailer bottom. Conclusions: From the test results, it could be recommended that the agricultural products transportation trailer should be equipped with vibration absorption device of HLS.

Generation of Artificial Earthquake Ground Motions for the Area with Low Seismicity (국내 지진 기록을 이용한 약진 지역에서의 인공지진파 발생에 관한 연구)

  • 김승훈;이승창;한상환;이리형
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.10a
    • /
    • pp.497-504
    • /
    • 1998
  • In the nonlinear dynamic structural analysis, the given ground excitation as an input should be well defined. Because of the lack of recorded accelerograms in Korea, it is required to generate an artificial earthquake by a stochastic model of ground excitation with various dynamic properties rather than recorded accelerograms. It is well own that earthquake motions are generally non-stationary with time-varying intensity and frequency content. Many researchers have proposed non-stationary random process models. Yeh and Wen (1990) proposed a non-stationary stochastic process model which can be modeled as components with an intensity function, a frequency modulation function and a power spectral density function to describe such non-stationary characteristics. This model is based on the simulation for the strong-motion earthquakes with magnitude greater than approximately 5.0~6.0, because it will be not only expected to cause structural damage but also involved the characteristics of earthquake motions. Also, the recorded earthquake motion within this range are still very scarce in Korea. Thus, it is necessary to verify the model by the application of it to the mid-magnitude (approximately 4.0~6.0) earthquakes actually recorded in domestic or foreign area. The purpose of the paper is to generate an artificial earthquake using the model of Yeh and Wen in the area with low seismicity.

  • PDF

Unified Reliability and Its Cost Evaluation in Power Distribution Systems Considering the Voltage Magnitude Quality and Demand Varying Load Model (전압 크기의 품질 및 전력수요 변동모델을 고려한 배전계통의 통합적인 신뢰도 및 비용 평가)

  • Yun, Sang-Yun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.12
    • /
    • pp.705-712
    • /
    • 2003
  • In this paper, we propose new unified methodologies of reliability and its cost evaluation in power distribution systems. The unified method means that the proposed reliability approaches consider both conventional evaluation factor, i.e. sustained interruptions and additional ones, i.e. momentary interruptions and voltage sags. Because the three voltage quality phenomena generally originate from the outages on distribution systems, the basic and additional reliability indices are summarized considering the fault clearing mechanism. The proposed unified method is divided into the reliability evaluation for calculating the reliability indices and reliability cost evaluation for assessing the damage of customer. The analytic and probabilistic methodologies are presented for each unified reliability and its cost evaluation. The time sequential Monte Carlo technique is used for the probabilistic method. The proposed DVL(Demand Varying Load) model is added to the reliability cost evaluation substituting the average load model. The proposed methods are tested using the modified RBTS(Roy Billinton Test System) form and historical reliability data of KEPCO(Korea Electric Power Corporation) system. The daily load profile of the each customer type in domestic are gathered for the DVL model. Through the case studies, it is verified that the proposed methods can be effectively applied to the distribution systems for more detail reliability assessment than conventional approaches.