• Title/Summary/Keyword: Daily delivery loads

Search Result 14, Processing Time 0.023 seconds

Development of the Estimation Model on Daily Pollutant Loads for the Watersheds in the Nakdong River Basin I. Correction and Verification for the Model (낙동강 유역에 대한 일별 유달부하량 산정모델개발 I. 모델식의 보정 및 검증)

  • Yoon, Young-Sam;Kim, Moon-Soo;Yu, Jae-Jung;Lee, Hae-Jin;Lee, Jun-Bae;Yang, Sang-Yong
    • Journal of Environmental Science International
    • /
    • v.16 no.2
    • /
    • pp.203-210
    • /
    • 2007
  • The delivery load data obtained from Nakdong river basin are used for developing the model estimating the daily delivery load on the main side streams of Nakdong River. The developed model assesses the daily contamination loads of the main thirteen side streams that contribute to the main stream of Nakdong river. It is developed that the model using the simplified equation that can estimate the daily delivery loads on the side main streams of Nakdong river for a period of having no data of the water quality and flow. The developed model for estimating the daily delivery loads from the main side streams in Nakdong river basin on each item such as BOD, TN, and TP is expressed as Daily delivery load ($\frac{kg}{day}$) = Production load $(\frac{kg}{day}){\times}(1-{\alpha}){\times}(\frac{daily\;runoff}{average\;runoff\;per\;year}){\gamma}$. The estimated values obtained by using the model are almost fit to the calculated values (real data) that have been acquired from the thirteen main side streams in Nakdong river basin. The correlation coefficient values, R, that indicate the correlation between the estimated and the calculated show over 0.7 that mean the estimated values from the used model are adapted to the real data except TN values of Nam-river, Hwang-river, Gam-river, We-river. Especially, the correlation of TP values between the estimated and the calculated implies quite a creditable data to use.

Evaluation of Application to Pre-Developed Delivery Load Equation at Upper Watershed of the Daechung Reservoir (대청호 상류유역의 기 개발된 유달부하량 산정식의 적용성 평가)

  • Lee, Jun-Bae;Kim, Kap-Soon;Lee, Kyu-Seung;Yoon, Young-Sam;Lim, Byung-Jin;Jung, Jae-Woon
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.1
    • /
    • pp.16-23
    • /
    • 2012
  • BACKGROUND: To improve the Daechung reservoir water quality, a quantitative estimation of the delivery load from upper watershed need to be conducted prior to others. To do so, an intensive monitoring is necessary because of the complexity and uncertainty of the delivery load from uppper watershed. However, intensive monitoring need to invest much time, cost, and effort. So, many researcher have developed an equation to estimate the delivery loads. But, relatively little research has been conducted on the applicability of pre-developed equation using other sites. Therefore, the objective of this study was to evaluate application of the equation for BOD, T-N and T-P delivery load. METHODS AND RESULTS: To verify the applicability of the equation, the following equation was used; Delivery loads(kg/day)=generated pollutant loads${\times}(1-{\alpha}){\times}$(daily outflow/${\beta})^{\gamma}$. The equations could be calculated the daily delivery loads of streams without any data of water quality, only with the data of daily runoff of study sites. The equations were applied to Youngdogcheon, Chogangcheon, Bocheongcheon, Sookcheon to examine its applicability using monitoring data. The results showed that the estimated delivery loads were in a good agreement with the observed data and indicated reasonable applicability of the equations. CONCLUSION(s): Overall, the equations were satisfactory in estimation of delivery loads at upper watershed of the Daechung reservoir. Therefore, the equations could be contributed to better water quality management in the Daechung reservoir.

Empirical Equation for Pollutant Loads Delivery Ratio in Nakdong River TMDL Unit Watersheds (낙동강 오염총량관리 단위유역 유달율 경험공식)

  • Kim, Mun Sung;Shin, Hyun Suk;Park, Ju Hyun;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.580-588
    • /
    • 2009
  • In this study daily flow rates and delivered pollutant loads of Nakdong river basin are simulated with modified TANK model and minimum variance unbiased estimator. Based on the simulation results, flow duration curves, load duration curves, and delivery ratio duration curves have been established. Then GIS analysis is performed to obtain several hydrological geomorphic characteristics such as watershed area, stream length, watershed slope and runoff curve number. Finally, multiple regression analysis is carried out to estimate empirical equations for pollutants delivery ratio. The results show that there is positive relation between the flow rates and delivery ratios, and the proposed empirical formulas for delivery ratio can predict well river pollutant loads.

Estimation of Pollutant Loads Delivery Ratio by Flow Duration Using Regression Equation in Hwangryong A Watershed (회귀식을 이용한 황룡A 유역에서의 유황별 유달율 산정)

  • Jung, Jae-Woon;Yoon, Kwang-Sik;Joo, Seuk-Hun;Choi, Woo-Young;Lee, Yong-Woon;Rhew, Doug-Hee;Lee, Su-Woong;Chang, Nam-Ik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.6
    • /
    • pp.25-31
    • /
    • 2009
  • In this study, pollutant loads delivery ratio by flow duration in Hwangryoung A watershed was estimated. The delivery ratio was estimated with measured data by Ministry of Environment(MOE) and the regression equation based on geomorphic parameters. Eight day interval flow data measured by the MOE were converted to daily flow to calculate daily load and flow duration curve by correlating data of neighboring station which has daily flow data. Regression equation developed by previous study was tested to study watershed and found to be satisfactory. The delivery ratios estimated by two methods were compared. For the case of Biochemical oxygen demand(BOD), the delivery ratios of low flow condition were 7.6 and 15.5% by measured and regression equation, respectively. Also, the delivery ratios of Total phosphorus(T-P) for normal flow condition were 13.3 and 6.3% by measured and regression equation, respectively.

The Simulation of Nutrients using SWAT Model and its Application to Estimate Delivery Ratio (SWAT 모형을 이용한 영양물질 모의 및 유달율 추정에의 적용)

  • Choi, Daegyu;Shin, Hyun Suk;Yoon, Young Sam;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.3
    • /
    • pp.375-385
    • /
    • 2009
  • The estimation of delivery ratio is a essential part of Korean Total Maximum Daily Loads (TMDL) procedure which needs a number of observed stream flow and pollutants data. If observed data were not sufficient, researchers have to find other alternatives. One of them is to make indirect data by using watershed models, such as Soil and Water Assessment Tool (SWAT) and Hydrological Simulation Program - FORTRAN (HSPF) and so on. In this study, indirect daily data was made by using SWAT model. To build the Byongseong-SWAT model accurately, crop cultures are reflected by handling the MGT.file in SWAT model. Especially, mass of manure and schedule of crop culture are inputted through investigating domestic research papers as well as fieldwork. After calibrating SWAT model in comparison with the 22-years flow and pollutants observed outlet data, the delivery ratio of Byongseong watershed is calculated by using daily simulated data during 2004-2007. Empirical equations for delivery ratio through multi-regression analysis are developed by using meteorological and physical factors such as flow, watershed area, stream length, catchment slope, curve number (CN) and subbasin's pollutant discharge loads.

Development of the Estimation Model on Daily Pollutant Loads for the Nakdong River Basin II. Application of the Model (낙동강 유역에 대한 일별 유달부하량 산정모델개발 II. 모델식의 활용)

  • Yoon, Young-Sam;Yu, Jae-Jeong;Kim, Moon-Soo;Lee, Hae-Jin;Lee, Jun-Bae;Yang, Sang-Yong
    • Journal of Environmental Science International
    • /
    • v.16 no.3
    • /
    • pp.333-345
    • /
    • 2007
  • As analyzed the estimated values of the daily delivery loads from thirteen major side streams such as Naesung-river, Keumho-river, Hwang-river, Nam-river during five years (from 1999 to 2003), the daily BOD inflow into the main stream of Nakdong river in 2003 shows the highest quantity as 31.1 ton and the daily BOD inflows in 1999, 2000, 2001, and 2002 are 26.7 ton, 22.5 ton, 21.0 ton, 25.8 ton, respectively. The daily TN in-flow into the main stream of Nakdong river in 2003 shows also the highest quantity as 64.9 ton and the daily TN inflows in 1999, 2000, 2001, and 2002 are 55.19 ton, 46.27 ton, 39.5 ton, 53.38 ton, respectively. The daily TP inflow into the main stream of Nakdong river in 2003 shows the highest quantity as 2.70 ton likewise and the daily TP inflows in 1999, 2000, 2001, and 2002 are 2.17 ton, 1.87 ton, 1.60 ton, 2.10 ton, respectively The rate of BOD loads from each side main stream into the main stream of Nakdong river shows that the BOD loads of Keumho-river are the highest as the values range from 32.8 % (2002) ${\sim}$ 35.1 % (2003) and the BOD loads of Nam-river, Naesung-river, Hwang-river are high in the order named. The rate of TN loads to the main stream is also similar to the trend of BOD loads. The contribution of the TN loads of Geumho-river to the contamination of the main stream is also the highest having a range from 27.0 % (2002) to 28.8 % (1999) among the main side streams and the TN loads of Naesung-river, Nam-river, and Heachun-river are high in the order named. The rate of TP loads is quite different from the trend of BOD and TN loads. The TP rate of Keumho-river, however, is still the highest as ranging 58.6 % (2002) to 61.7 % (2003) and the river has the biggest portion (over 50%) of the entire pollution to the main stream of Nakdong river.

Estimation of Delivery Ratio Based on BASINS/HSPF Model for Total Maximum Daily Load (BASINS/HSPF 모형을 이용한 수질오염총량관리 유달율 산정방법 연구)

  • Park, Ju-Hyun;Hwang, Hasun;Rhew, Doughee;Kwon, Oh-Sang
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.833-842
    • /
    • 2012
  • In this study Window interface to Hydrological Simulation Program-FORTRAN (HSPF) developed by the United States Environmental Protection Agency (EPA) was applied to the upstream of Namgang watershed to estimate its applicability for estimating Delivery Ratio (DR) of water pollutants for Total Maximum Daily Load (TMDL). BASINS/HSPF which is selected in this study, is found to be appropriate for simulation of daily flow and water quality in target basins. DR was estimated utilizing discharge loads of unobserved sub-basin and delivery load of unobserved locations obtained not by actual evaluation but by simulation through validation and verification. Annual average DR of BOD, TN and TP were 0.97 ~ 1.50, 2.23 ~ 3.21, and 0.81 ~ 1.09 respectively. Net DR of dependent basins excluding influence of upstream basin was 1.50 ~ 1.70, 0.55 ~ 0.69, and 0.24 ~ 0.31, all of which are lower than those of independent basins area. Utilizing the model selected by this research, DR and Net DR of unobserved basins will be estimated, which will help determine priorities in management of basin areas.

Environmental Analysis of a Windowless Delivery Swine Building : Temperature and Relative Humidity (무창분만돈사의 온.습도 환경 분석)

  • 이성현;조한근;장유섭
    • Journal of Animal Environmental Science
    • /
    • v.3 no.2
    • /
    • pp.77-85
    • /
    • 1997
  • Recently, local swine producers are rapidly adopting the indoor production system which developed in foreign countries. However, this imported system is reported as not functioning properly because of different climate conditions. The objective of this project was to investigate the environment characteristics of a windowless delivery swine building. The parameters studied were the heating and cooling loads, the daily changes of indoor temperature and relative humidity, the horizontal and the vertical distributions of indoor temperature, and the effect of mist cooling on indoor temperature. From this study, the following are founded : 1. The maximum cooling and heating loads were - 317.0kcal/㎡$.$h and 336.5kal/㎡$.$h in summer and in winter. The large loads seems to be on account of inappropriate operations of ventilating fans. 2. The daily variations of relative humidity in indoor were smaller than those in outside. Those values both in summer and in winter as relative humidities in door was lower than optimum for growing pigs, the additional humidifier might be helpful to increase the relative humidity in indoor. 3. The horizontal distribution of the indoor temperature was found to be uniform in the variation range of 1$^{\circ}C$. 4. The vertical distribution of the indoor temperature was not found to be uniform; the temperature of upper part was higher than that of slot part. 5. Average values of indoor temperature became lower by 3$^{\circ}C$ by mist cooling. But the variation of temperature was found to be larger; The middle part of the room was cooled down, but the corner part of the room was not affected by misting due to uneven nozzle configuration.

Delivered Pollutant Loads of Point and Nonpoint Source on the Upper Watershed of Lake Paldang - Case Study of the Watershed of Namhan River and Gyeongan Stream (팔당호 상류유역의 점·비점오염원 유달부하 특성 - 남한강·경안천 수계를 대상으로)

  • Park, Ji Hyoung;Kong, Dong Soo;Min, Kyung Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.750-757
    • /
    • 2008
  • This study is conducted to characterize and evaluate delivered pollutant loads of point and nonpoint source on the upper watershed of lake paldang. The study area consists of 12 watersheds in Namhan-river and Kyungahcheon, which are approximately 80% of total area of Namhan-river and Kyungahcheon. Based on daily delivered loads from watersheds, 61% of $BOD_5$, 81% of T-N and 70% of T-P were from nonpoint sources, suggesting that delivered loads of nonpoint pollutants be crucial to water quality. On the other hand, 78% of $BOD_5$, 92% of T-N and 87% of T-P as delivered load were from nonpoint sources in an upper watershed of Namhan-river, while 48% of $BOD_5$, 70% of T-N and 57% of T-P as delivered load were from nonpoint sources in a lower watershed of Namhan-river, suggesting higher dependency of point sources than upper watershed of Namhan-river. In the characteristic of delivered loading pollutants from point and nonpoint pollution sources, delivered load of nonpoint pollutants differed significantly by seasonal flow, and as though discharged load of point pollutants were yearly uniform, delivered load of point pollutants was found to be flow-dependent because its delivery ratio was changed.

Evaluation of Discharge-Water Quality Characteristics and River Grade Classification of Jinwi River Unit Basin (진위천 단위유역의 유량-수질 특성 및 하천 등급화 평가)

  • Cho, Yong-Chul;Choi, Jin-Woo;Noh, Changwan;Kwon, Phil-Sang;Kim, Sang-hun;Yu, Soonju
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.6
    • /
    • pp.704-716
    • /
    • 2018
  • The aim of this study is to examine the characteristics analysis of the discharge and water quality based on TPLMS (Total Pollution Load Management System) in the Jinwi River unit basin, and to propose a management plan by selecting the point that needs improvement of water quality in order to achieve the target water quality. We evaluated the discharge and water quality characteristics, statistical analysis, daily delivery load and daily delivery density, grade classification, for 14 total pollution load site's from 2014 to 2016 year in Jinwi river unit basin. The average discharge of Jinwi river unit basin is $22.411m^3/s$ and discharge of Hwangguji River is 32.8% and the water quality characteristics along the tributary river were clarified spatially. As the result, it was analyzed that Seongeun River is an indirect indicator of organic pollutants, Gwanri River is a seasonal factor, Osan River and Hwangguji River both affect water quality. Estimation of delivered pollutant loads at the HG-3 site was 6,470.4 BOD kg/day, 6,846.7 TN kg/day and delivered pollutant loads density increased to $220.9BOD\;kg/day/km^2$, $22.4TP\;kg/day/km^2$ at the HG-4 site. This result demonstrates that the total pollution load site needed to improve water quality of the Jinwi River unit basin was HG-3 site.