• 제목/요약/키워드: Daily Maximum Air Temperature

검색결과 135건 처리시간 0.024초

NOAA/AVHRR 자료를 이용한 일 최고기온 추정에 관한 연구 (Estimation of daily maximum air temperature using NOAA/AVHRR data)

  • 변민정;한영호;김영섭
    • 한국GIS학회:학술대회논문집
    • /
    • 한국GIS학회 2003년도 공동 춘계학술대회 논문집
    • /
    • pp.291-296
    • /
    • 2003
  • This study estimated surface temperature by using split-window technique and NOAA/AVHRR data was used. For surface monitoring, cloud masking procedure was carried out using threshold algorithm. The daily maximum air temperature is estimated by multiple regression method using independent variables such as satellite-derived surface temperature, EDD, and latitude. When the EDD data added, the highest correlation shown. This indicates that EDD data is the necessary element for estimation of the daily maximum air temperature. We derived correlation and experience equation by three approaching method to estimate daily maximum air temperature. 1) non-considering landcover method as season, 2) considering landcover method as season, and 3) just method as landcover. The last approaching method shows the highest correlation. So cross-validation procedure was used in third method for validation of the estimated value. For all landcover type 5, the results using the cross-validation procedure show reasonable agreement with measured values(slope=0.97, intercept=-0.30, R$^2$=0.84, RMSE=4.24$^{\circ}C$). Also, for all landcover type 7, the results using the cross-validation procedure show reasonable agreement with measured values(slope=0.993, Intercept=0.062, R$^2$=0.84, RMSE=4.43$^{\circ}C$).

  • PDF

태양복사 및 기상요소의 고농도 오존형성에 대한 상관성 분석 (Correlation analysis of solar radiation and meteorological parameters on high ozone concentration)

  • 안재호
    • KIEAE Journal
    • /
    • 제12권6호
    • /
    • pp.93-98
    • /
    • 2012
  • The concerns on high ozone concentration phenomenon is significantly growing in Seoul metropolitan area including the industry complex area, like Shiwha Banwol area. The aims of this research is the analysis of relationship between high concentrations of $O_3$ and solar radiation parameters in atmosphere. The understanding of the effects of solar radiation intensity, humidity, high air temperature on ozone concentration in a day is very useful to provide a direction for reducing of the high ozone concentration to a local government or a metropolitan government. The correlation analysis between maximum ozone concentration and various meteorological parameters in 2009 - 2011 carried out using IBM's SPSS program. The results showed that the mean correlations coefficient (R) between daily Ozone maximum and solar radiation resulted R = 0.64 during 2011. May - September in 10 air pollution stations. In case of correlations between daily ozone maximum and relative humidity showed negative correlation R = -0.61. The correlation analysis with mean air temperature during 1-3 PM resulted R = 0.29. This low correlation coefficient could be corrected by using of categorized data of ozone concentration. The daily maximum ozone concentration is more dependent on peak solar radiation and high air temperature during 1-3 PM than its simple daily maximum values. The results of this research would be used to develop the high ozone alert system around Seoul metropolitan area. This correlation analysis could be partially integrated to prediction of ozone peak concentration in connection with other methods like classification and regression tree(CART).

지상 고밀도 관측 시스템을 이용한 대구의 여름철 고온현상 조사 (Investigation of Urban High Temperature Phenomenon in Summer using the High Density Ground Monitoring System in Daegu Metropolitan Area)

  • 김상헌;조창범;김해동
    • 한국환경과학회지
    • /
    • 제23권9호
    • /
    • pp.1619-1626
    • /
    • 2014
  • We analyzed diurnal variations in the surface air temperature using the high density urban climate observation network in Daegu metropolitan city, the representative basin-type city in Korea, in summer, 2013. We used a total of 28 air temperature observation points data(16 thermometers and 12 AWSs). From the distribution of monthly average air temperature, air temperature at the center of Daegu was higher than the suburbs. Also, the days of daily minimum air temperature more than or equal to $25^{\circ}C$ and daily maximum air temperature more than or equal to $35^{\circ}C$ at the schools near the center of Daegu was more than those at other schools. This tendency appeared more clearly on the days of daily minimum air temperature more than or equal to $25^{\circ}C$. Also, the air temperature near the center of the city was higher than that of the suburbs in the early morning. Thus it was indicated that the air temperature was hard to decrease as the bottom of the basin. From these results, the influence of urbanization to the formation of the daily minimum temperature in Daegu was indicated.

제주도 초지피복 기생화산("오름")의 방위별 일 최고기온 분포 (Azimuthal Distribution of Daily Maximum Temperatures Observed at Sideslopes of a Grass-covered Inactive Parasitic Volcano ("Ohreum") in Jeju Island)

  • 서희철;전승종;윤진일
    • 한국농림기상학회지
    • /
    • 제10권1호
    • /
    • pp.25-31
    • /
    • 2008
  • 초지피복 조건에서 사면의 일사수광량 차이가 일 최고기온에 미치는 영향을 파악하기 위해 2007년 하지부터 동지까지 밑면지름 570m, 높이 90m인 원추형 기생화산 "높은오름"의 측면 경사 8 지점에서 일 최고기온을 측정하였다. 8개 지점 평균값을 기준온도로하여 각 지점의 기온편차를 구해 비교한 결과 기온편차는 하지로부터 동지로 갈수록 커지는 경향이었고, 관측기간 평균은 남향사면에서 $1.0^{\circ}C$, 북향사면에서 $-0.8^{\circ}C$로서 그 차이가 평균 $1.8^{\circ}C$에 달했다. 기온편차의 월별 평균은 11월에 가장 크며 남향사면에서 $2.1^{\circ}C$, 북향사면에서 $-1.3^{\circ}C$였다. 일별 기온편차의 최대값은 남향사면에서 $3.8^{\circ}C$, 북향사면에서 $-2.7^{\circ}C$에 달했는데, 이러한 기온편차 변이는 일사수광량 편차에 근거한 지형특성지수와 높은 상관을 보여 복잡지형의 일 최고기온 추정모형 개발에 활용될 수 있을 것으로 기대된다.

Daily Changes in Red-Pepper Leaf Surface Temperature with Air and Soil Surface Temperatures

  • Eom, Ki-Cheol;Lee, Byung-Kook;Kim, Young-Sook;Eom, Ho-Yong
    • 한국토양비료학회지
    • /
    • 제47권5호
    • /
    • pp.345-350
    • /
    • 2014
  • This study was conducted to investigate the changes in daily surface temperature of red pepper leaf compared to air and soil surface temperature. The maximum, minimum and average daily temperatures of red pepper leaf were 27.80, 11.40 and $19.01^{\circ}C$, respectively, which were lower by 0.10, 7.60 and $3.86^{\circ}C$ than air temperature, respectively, and lower by 15.00, 0.0 and $4.38^{\circ}C$ than soil surface temperature, respectively. Mean deviations of the difference between measured and estimated temperature by the E&E Model (Eom & Eom, 2013) for the air and surface temperature of red pepper leaf and soil were 0.64, 1.82 and $4.77^{\circ}C$, respectively. The relationships between measured and estimated scaled factor of the air and surface temperature of red pepper leaf and soil were very close to the 1:1 line. Difference between air and surface temperature of red pepper leaf showed a linear decreasing function with the surface temperature of red pepper leaf. Difference between soil surface temperature and air and surface temperature of red pepper leaf linearly increased with the soil surface temperature.

河川의 日別 水溫差에 대한 推計學的 特性 (Stochastic Properties of Daily Temperature in Rivers)

  • Ahn, Ryong Me;Lee, Hong Keun
    • 한국환경보건학회지
    • /
    • 제10권1호
    • /
    • pp.1-12
    • /
    • 1984
  • The stochastic characteristics of the daily range of water temperature variation was analyzed by employing the techniques of autocorrelation coefficient, autoreggresive model and crosscorrelation model. These time series included daily observations on maximum and minimum values of water temperature and air temperature. The measurement was made by automatic recording instrument at Gu-yee and Dook-do in Han River, and at Waegwan and Gu-mi in Nackdong River in 1981. As a result of this study, it was found that (1) The correlogram of daily water temperature ranges $\Delta AT_i$ and daily air temperature $\Delta AT_i$ at Gu-mi and Gu-yee showed the exponential curves. (2) The most high frequency values of $\Delta AT_i$ and $\Delta WT_i$ were 11$\circ$C and 0.5${\circ}C$ respectively at every measuring site. (3) The correlation coefficients between the daily mean air temperature AT$_i$ and the daily mean water temperature were fairly high as 0.966 at Dook-do and 0.949 at Gu-yee, but the correlation coefficients between $\Delta AT_i$ and $\Delta WT_i$ were very low as 0.1074 at Gu-yee and 0.0324 at Dook-Do.

  • PDF

여름철 일 최고기온과 일사량의 최근 변동에 관하여 (On Recent Variations in Solar Radiation and Daily Maximum Temperature in Summer)

  • 최미희;윤진일
    • 한국농림기상학회지
    • /
    • 제11권4호
    • /
    • pp.185-191
    • /
    • 2009
  • 여름을 제외한 다른 계절의 온난화 혹은 일 최저기온에 대한 온실효과와 도시열섬효과에 관한 연구가 활발히 수행되었던 것에 비하면 여름철의 기온상승, 특히 일 최고기온의 상승에 대한 연구는 미흡하다. 최근 25년간 전국 18개 지점에서 관측된 우리나라의 여름철(6-8월) 일 최고기온 변화를 조사하고 그 변화에 미친 일사량의 영향을 분석한 결과, 평년(1971-2000)에 비해 하루 평균 일사량은 $0.61MJ\;m^{-2}$ 증가하였으며 같은 기간 일 최고기온은 $0.1^{\circ}C$ 상승한 것으로 확인된다. 이 기간 중 일사량의 연차변이는 여름 최고기온 연차변이의 65%를 설명할 수 있었다. 일사량의 증가는 대기투과율의 증가에 기인하며 대기투과율의 증가는 에어로졸 농도 특히 아황산가스 농도 감소 때문인 것으로 판단된다. 1999년부터 2007년까지 여름철 아황산가스 농도가 계속 감소해왔는데 이와 같은 경향이 앞으로도 지속된다면 대기투과율 증가 및 이에 따른 일사량 증가와 증가된 일사량으로 인한 최고기온 상승을 예상할 수 있다.

2016년 여름철 폭염 시기 대구의 기온공간분포 특성 (Spatial Distribution of Air Temperature during an Extreme Heat Period in Daegu Metropolitan Area in 2016)

  • 김지혜;김해동
    • 한국환경과학회지
    • /
    • 제26권9호
    • /
    • pp.1023-1029
    • /
    • 2017
  • We studied the distribution of air temperature using the high density urban climate observation network data of Daegu. The observation system was established in February 2013. We used a total of 38 air temperature observation points (23 thermometers and 18 AWSs). From the distribution of monthly averaged air temperatures, air temperatures at the center of Daegu were higher than in the suburbs. The daily minimum air temperature was more than or equal to $25^{\circ}C$ and the daily maximum air temperature was more than or equal to $35^{\circ}C$ at the elementary school near the center of Daegu. Also, we compared the time elements, which are characterized by the diurnal variation of surface air temperature. The warming and cooling rates in rural areas were faster than in urban areas. This is mainly due to the difference in surface heat capacity. These results indicate the influence of urbanization on the formation of the daily minimum temperature in Daegu.

복합형 태양열 가열기의 일일 운전 특성 및 축열 성능에 관한 연구 (A Study on Thermal Storage Performance and Characteristics of Daily Operation of a Hybrid Solar Air-Water Heater)

  • 최휘웅;파쿠르 로커만;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제35권3호
    • /
    • pp.73-79
    • /
    • 2015
  • In this study, a thermal storage performance and characteristics of daily operation were investigated when the air and the liquid were heated simultaneously by a hybrid solar air-water heater that can make hot water as well as heated air. The hybrid solar air-water heater is kind of a flat plate solar collector that can make hot water and heated air by installing air channel beneath absorber plate of traditional flat plate solar collector for hot water. As a result of daily operation, maximum water temperature reached in a thermal storage was shown $44^{\circ}C$ on 73kg/h of air mass flow rate and about $40^{\circ}C$ on 176kg/h of air mass flow rate. Thus, the necessity of heating water in thermal storage by operating only liquid side was confirmed when the temperature of liquid in thermal storage is lower than we need. In case of efficiency investigated on daily operation, the thermal efficiency of the liquid side was decreased with increment of the inlet liquid temperature and decrement of the solar radiation, but efficiency of the air side was increased with increment of inlet liquid temperature difference as the traditional solar air heater. Total thermal efficiency of the collector was shown from 65.85% to 78.23% and it was decreased with increment of the inlet liquid temperature and decrement of solar radiation same as the traditional system.

서울 및 6대 광역시의 기상요인을 고려한 대기오염이 주요 알레르기질환에 미치는 영향 (The Effect of Air Pollution on Allergic Diseases Considering Meteorological Factors in Metropolitan Cities in Korea)

  • 김효미;허진아;박윤형;이종태
    • 한국환경보건학회지
    • /
    • 제38권3호
    • /
    • pp.184-194
    • /
    • 2012
  • Objectives: We investigated the effects of air pollution on allergic diseases (allergic rhinitis, asthma, atopic dermatitis) in metropolitan cities in Korea, adjusting for meteorological factors. Methods: Data on daily hospital visits and hospital admissions for 2003-2010 was obtained from the National Health Insurance Cooperation. Meteorological data was obtained from the Korea Meteorological Administration. We then calculated daily mean temperature, daily mean humidity, daily mean air pressure at sea level, and diurnal temperature range. We used data on air pollution provided by the National Institute of Environmental Research. Maximum daily eight-hour average ozone concentrations and the daily mean $PM_{10}$ were used. We estimated excess risk and 95% confidence interval for the increasing interquatile range (IQR) of each air pollutant using Generalized Additive Models (GAM) that appropriate for time series analysis. Results: In this study, we observed an association between ozone and hospital visits for allergic rhinitis, asthma, and atopic dermatitis in all metropolitan cities, adjusting for temperature, humidity, air pressure at sea level, diurnal temperature range, and day of the week. Ozone was associated with hospital visits for allergic rhinitis, asthma, and atopic dermatitis across all metropolitan cities. However $PM_{10}$ was associated with allergic-related diseases in only select cities. Also, ozone and $PM_{10}$ were associated with hospital admission for asthma in all cities except Gwangju. Hospitalization for the other diseases failed to show consistent association with air pollutants. Conclusion: In the findings of this study, there was a significant association between air pollutants and allergic-related diseases. More detailed research subdivided age group or conducting meta-analyses combining data of all cities is required.