• Title/Summary/Keyword: Dacron

Search Result 182, Processing Time 0.028 seconds

Surgical Observations of Diseases of the Aorta (대동맥질환에 대한 외과적 고찰)

  • Rho, Joon Ryang
    • Journal of Chest Surgery
    • /
    • v.9 no.2
    • /
    • pp.251-264
    • /
    • 1976
  • Forty three patients with disease of the aorta were admitted in this department during the period from beginning of 1956 to the end of 1976. They consisted of eighteen cases of aortic aneurysms, eight cases of Takayasu's arteritis, eight Leriche syndromes, six dissecting aneurysms, two aortic coarctations and one case of vascular ring. Of eighteen aortic aneurysms, twelve were operated resulting in eight survivors. Three of four mortalities were in shock preoperatively because of aneurysmal rupture. Among six dissecting aortic aneurysms, four were type III and two were type I according to DeBakey's classification. For the purpose of relief of acute arterial insufficiency in the lower extremities, a re-entry operation grafting a Y-shaped dacron vessel between abdominal aorta and common iliac arteries was performed. The patient regained consciousness soon after the operation and was well until postoperative second day, when severe convulsion developed abruptly and died. And in a chronic case of type III dissecting aneurysm, a dacron graft bypass shunt between ascending aorta and lower descending thoracic aorta with resection of the aneurysm was performed, but acute severe aortic insufficiency developed soon after the operation and fell into intractable heart failure resulting in death. The cause of the aortic insufficiency seems to be retrograde dissection from the proximal anastomosis site in the ascending aorta. Three cases were treated medically with Wheat's regimen. Two of them survived with relief of symptoms. Eight patients of Takayasu's arteritis were all females and aged between twenty and forty-four averaging twenty nine. Bypass graft operation between aortic arch and carotid arteries using Y-shaped nylon prostheses were performed in three patients resulting in death in two cases postoperatively due to severe cerebral arterial insufficiency during the procedure. All the patients with Leriche syndrome were males and over forty. In two cases, bypass graft with Y-shaped dacron vessel between terminal aorta and common iliac or femoral arteries were performed with good result. Thromboembolectomy or thromboendarterectomy was employed in three patients, of whom one was aggravated in sexual problem postoperatively. One out of two aortic coarctations and a vascular ring were treated surgically with excellent results.

  • PDF

Infective Endocarditis Involving Aortic Valve, Mitral Valve, Tricuspid Valve, and luterventricular Septum -A Case Report (대동맥판막, 승모판막, 삼첨판막과 심실중격을 침범한 심내막염 -1예 보고-)

  • 박종빈;서동만
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.200-204
    • /
    • 1997
  • This is a report of a successful management of a patient with infective endocarditis involving native aortic valve, mitral valve, tricuspid valve, and Interventric lar septum. A 16 year-old patient who underwent VSD patch closure, and aortic valvuloplasty at the age of 1 1 years showed Intractable congestive heart failure during antibiotics treatment for infective endocarditis. Operative findings revealed that there were large defect along the previous patch, aortic regurgitation with multiple perforations and vegetations, mitral regurgitation with vegetation, aortic paraannular abscess, interventricular myocardial abscess, and tricuspid regurgitation with perforations and vegetations. We reconstructed the interventricular defect with Dacron patch extending to the aortic valve annulus after radical debridement of all infected or devitalized tissues, and could implant aortic valve by anchoring to the reconstructed Dacron patch. Mitral valve was replaced and tricuspid valve was repaired with patient's own pericardium. The patient was discharged after antibiotics treatment for 6 weeks and in good condition without any sequelae for 12 months.

  • PDF

A Case of Metastatic breast Cancer and Reconstruction of Superior Vena Cava by Woven Dacron Y Graft (전이성 유암에서 Woven Dacrorl Y graft를 이용한 상대공정맥 재건술 -치험 III-)

  • 이원진;신호승
    • Journal of Chest Surgery
    • /
    • v.29 no.3
    • /
    • pp.346-349
    • /
    • 1996
  • This 32 year old female patient underwent left radical mastectomy due to ductal carcinoma on May 1990, and treated with FAM (5-fluorouracil, Adriamycin and Mitomycin C) regimen postoperatively. However, right cervical Iymph node enlargement and facial edema progressively developed since December 199). On April 1994, operation was performed, and findings were as followes; x4$\times$5$\times$7 to 1 : 1 $\times$ 1 cm sized multiple enlarged and hyperemic Iymph nodes were scatterred throughout submandibular area to the junction of superior vents cave and pericardium, and partially invaded both anterior segmental lobe, sternum and both distal tip of clavicles. After radical dissection of the nodes of neck and mediastinal nodes, and wedge resection of both anterior segments of lung, and partial resection of both clavicle tips and total sternum. The both innominate veins and superior vena cava were partially obstructed by invaded cancer SVC reconstruction was done with preclotted 10$\times$ 10$\times$ 18mm Y shap d woven Dacron graft, which was anastomosed to the point of the junction of subclavian vein and jugular vein after cross clamping both veins and 2cm above the pericardial junction with one arm clamp. After maintaining blood drainage to the SVC from the right side, left innominate vein was anastomosed with 4-0 Prolene continuous running suture. Bone cement was used for resected sternal portion and clavicular ends were fixed to postal portion with 18 Gauge wires. The patient was treated with radiation and chemotherapy after discharge, and there were no evidence of regrowing of the mass nor obstruction of the graft inspite of no antithrombotic therapy.

  • PDF

Short-term Outcomes of Aortic Wrapping for Mild to Moderate Ascending Aorta Dilatation in Patients Undergoing Cardiac Surgery

  • Park, Ji-Young;Shin, Je-Kyoun;Chung, Jin-Woo;Kim, Jun-Seok;Chee, Hyun-Keun;Song, Meong-Gun
    • Journal of Chest Surgery
    • /
    • v.45 no.3
    • /
    • pp.148-154
    • /
    • 2012
  • Background: The adequate management of mild to moderate dilatation of the ascending aorta during cardiac operations remains controversial. In this study, we present the short-term outcomes of 90 patients undergoing ascending aortic wrapping with a Dacron graft during other cardiac operations. Materials and Methods: From March 2008 to January 2011, 90 consecutive patients underwent treatment for ascending aortic aneurysm using the external wrapping technique during the concomitant procedure. The study group consisted of 49 male and 41 female patients with a mean age of $58.7{\pm}13$years. The primary cardiac surgical procedures were coronary artery bypass grafting (CABG) in 3, aortic valve replacement in 2, and aortic valvuloplasty in 85 patients (isolated in 62 and combined with CABG or mitral valvuloplasty in 23). The ascending aorta diameter was measured using a computed tomography scan within 4 weeks after surgery, and was compared with the preoperative value. Results: The diameters of the ascending aorta wrapped with the Dacron graft were significantly reduced within a month after surgery from $46.4{\pm}4.3$ mm to $33.0{\pm}3.5$ mm (p<0.05). There was no early mortality or major surgical complication. During the mean follow-up period of $15.4{\pm}5.2$ months, there was only one late death caused by septic multiorgan failure. Conclusion: Dacron wrapping of the ascending aorta offers excellent results with very low mortality and morbidity, and it can be regarded as a safe and effective method for the treatment of moderately dilated ascending aorta in selected patients.

One case report of abdominal aortic aneurysm (복부대동맥파류 1예수술치험)

  • 김학제
    • Journal of Chest Surgery
    • /
    • v.19 no.3
    • /
    • pp.522-527
    • /
    • 1986
  • There have been several reports of abdominal aortic aneurysm according to increase in life span and greater awareness of the diagnosis in Korea. We had a surgical experience of abdominal aortic aneurysm due to arteriosclerosis in 76 years old male. With abdominal sonogram, he was diagnosed. Aortoiliac bypass was done with double velour Dacron Y graft. Postoperative course was uneventful.

  • PDF

Syphilitic aortic aneurysm -A case report- (매독성 대동맥류의 수술치험 -1예 보고-)

  • 김범식
    • Journal of Chest Surgery
    • /
    • v.19 no.3
    • /
    • pp.475-478
    • /
    • 1986
  • Syphilitic aortic aneurysm is a rare lesion today. We experienced a case of huge syphilitic ascending aortic aneurysm with aortic insufficiency. Surgical correction was done by replacement of ascending aorta with woven Dacron graft and aortic valve replacement under cardiopulmonary bypass. There is no abnormality in postoperative aortography. The postoperative course was uneventful.

  • PDF

Surgical Treatment of Traumatic Ventricular Septal Defect by Penetrating Chest Injury (흉부관통상으로 인한 심실중격결손의 치료)

  • 김시욱;한종희;강민웅;나명훈;임승평;이영;최시완;유재현
    • Journal of Chest Surgery
    • /
    • v.37 no.12
    • /
    • pp.999-1002
    • /
    • 2004
  • Thirteen year old boy who had been stabbed in his left chest by the knife was transferred to our department from a general hospital, because of the massive bleeding from the intercostal tube drainage. Chest X-ray showed homogeneous density in the left lung field. He was confused and his vital signs were unstable. He was moved into a operating room as soon as possible. After resuscitation, his lacerated left ventricle wound was sutured through median sternotomy. The interventricular shunt was detected with intraoperative transesophageal echocardiography. The traumatic ventricular septal defect was closed via left ventricle using Dacron patch. His postoperative course was uneventful, and he was discharged with small residual shunt.

Surgical Treatment of the Pseudoaneurysm of the Ascending Aorta after Bentall Operation (Bentall씨 수술후 발생한 상행대동맥 가성동맥류 치험 1례)

  • Hong, Jong-Myun;Ahn, Hyuk;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.24 no.9
    • /
    • pp.926-929
    • /
    • 1991
  • A 31 year-old male patient underwent surgical treatment of the pseudoaneurysm of the ascending aorta complicating after the Bentall operation, He had undergone the replacement of the ascending aorta using the composite valved graft with direct coronary reimplantation under the diagnosis of the annuloaortic ectasia of ascending aorta associated with Marfan syndrome. Eleven months after the operation, he started to feel dyspnea and anterior chest pain, and was diagnosed as pseudoaneurysm around the ascending aortic graft. The second operation consisted of the dacron patch closure of the defect of the aortic graft which was the hole for previous coronary reimplantation, and the anastomosis between the coronary orifice and the aortic graft with the intermediate graft of a 10mm woven dacron tube, and suture closure of the fistula opening from the aneurysm. His postoperative course was uneventful and discharged without complication. He is doing well 10 months postoperatively.

  • PDF

Truncus Arteriosus -Report of a Case- (동맥간(動脈幹) 1례(例) 보고(報告))

  • Hong, Jang Soo;Park, Joo Chul;Rho, Joon Ryang;Kim, Chong Whan;Suh, Kyung Phil;Lee, Yung-Kyoon
    • Journal of Chest Surgery
    • /
    • v.9 no.2
    • /
    • pp.271-275
    • /
    • 1976
  • Truncus arteriosus is a rare and highly lethal cardiac anomaly characterized by a single arterial trunk emerging from the heart and supplying the coronary, systemic, and pulmonary circulations, The first successful correction of truncus arteriosus was reported by McGoon et al. in 1968 and was based on experimental work reported by Rastelli et al. in 1967 in which a conduit consisting of a homograft of the ascending aorta and aortic valve was used to establish continuity between the right ventricle and the pulmonary arteries, Modification of this procedure using a Dacron tube valved with porcine xenograft instead of a homograft have resulted in the current definite treatment for truncus arteriosus. This report describes an 3 years and 4 months old boy with heart failure from type I truncus arteriosus who was diagnosed as the V. S. D. with pulmonary hypertension preoperatively and underwent corrective surgery employing the Rastelli procedure using a Dacron conduit valved with canine xenograft, but died due to massive bleeding from the anastomosis sites in operating room.

  • PDF

Ebstein`S Anomaly: A Case Report of Plication and Tricuspid Valve Replacement (Ebstein 심기형 수술 1례[Plication 및 삼첨판막 이식예])

  • 송명근
    • Journal of Chest Surgery
    • /
    • v.11 no.3
    • /
    • pp.342-347
    • /
    • 1978
  • A 8 year old male was admitted to the Department of Thoracic Surgery, Korea University Hospital on June 22, 1978. The chief complaints were cyanosis and exertional dyspnea since at birth. EKG shows BVH and dextrocardia, phonocardiogram revealed the accentuation of second heart sound in aortic area. Echocardiogram from the left ventricle to the base of the heart, there is a discontinuity between the ventricular septum and the anterior aortic margin with a large aortic root & aortic overriding. His cardiac catheterization data and cardiac angiogram shows situs inversus totalis, dextrocardia, right aortic arch, large ventricular septal defect etc., and finally diagnosed Truncus Arteriosus. Edwards type IV with retrograde aortogram and selective bronchial angiogram. This is the first operative case reported as Rastelli operation for Truncus Arteriosus type IV in the literatures in Korea. Authors have experienced I case of Truncus Arteriosus, Edward type IV and Rastelli operation with Dacron Arterial Conduit Graft under cardiopulmonary bypass on July 3, 1978. The procedures were as follows; 2] Cardiopulmonary bypass: Origin of bronchial arteries excised from descending aorta bilaterally; defects in aorta closed. 2] Horizontal incision made high in right ventricle. 2] Ventricular septal defect [Kirklin type I+II] closed with Teflon patch. 4] Bifurcated dacron arterial graft with pericardial monocusp sutured to the bilateral pulmonary arteries. [Diameter 9 mm: Length 7 cm]. 5] Proximal end of the conduit graft anastomosed to right ventricle. [Diameter 19 mm: Length 5 cm]..Total perfusion time was 220 min. The result of operation was poor due to anastomotic leakage and increased pulmonary vascular resistance resulting acute right heart failure. The patient was died on the operation table. Literatures were briefly reviewed.

  • PDF