• Title/Summary/Keyword: DROP-IN

Search Result 6,161, Processing Time 0.041 seconds

Freshness Monitoring of Raw Salmon Filet Using a Colorimetric Sensor that is Sensitive to Volatile Nitrogen Compounds (휘발성 질소화합물 감응형 색변환 센서를 활용한 연어 신선도 모니터링)

  • Kim, Jae Man;Lee, Hyeonji;Hyun, Jung-Ho;Park, Joon-Shik;Kim, Yong Shin
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.93-99
    • /
    • 2020
  • A colorimetric paper sensor was used to detect volatile nitrogen-containing compounds emitted from spoiled salmon filets to determine their freshness. The sensing mechanism was based on acid-base reactions between acidic pH-indicating dyes and basic volatile ammonia and amines. A sensing layer was simply fabricated by drop-casting a dye solution of bromocresol green (BCG) on a polyvinylidene fluoride substrate, and its color-change response was enhanced by optimizing the amounts of additive chemicals, such as polyethylene glycol, p-toluene sulfonic acid, and graphene oxide in the dye solution. To avoid the adverse effects of water vapor, both faces of the sensing layer were enclosed by using a polyethylene terephthalate film and a gas-permeable microporous polytetrafluoroethylene sheet, respectively. When exposed to basic gas analytes, the paper-like sensor distinctly exhibited a color change from initially yellow, then to green, and finally to blue due to the deprotonation of BCG via the Brønsted acid-base reaction. The use of ammonia analyte as a test gas confirmed that the sensing performance of the optimized sensor was reversible and excellent (detection time of < 15 min, sensitive naked-eye detection at 0.25 ppm, good selectivity to common volatile organic gases, and good stability against thermal stress). Finally, the coloration intensity of the sensor was quantified as a function of the storage time of the salmon filet at 28℃ to evaluate its usefulness in monitoring of the food freshness with the measurement of the total viable count (TVC) of microorganisms in the food. The TVC value increased from 3.2 × 105 to 3.1 × 109 cfu/g in 28 h and then became stable, whereas the sensor response abruptly changed in the first 8 h and slightly increased thereafter. This result suggests that the colorimetric response could be used as an indicator for evaluating the degree of decay of salmon induced by microorganisms.

Removal Performance of Sticky Paint Aerosol Control System Generated from Small Scale Car Paint Overspray Booth (소형 자동차 페인트 도장부스에서 발생하는 점착성 paint aerosol 처리장치에서 제거성능)

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Sohn, Jong-Ryeul;Park, Young-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.1
    • /
    • pp.54-62
    • /
    • 2015
  • Small scale paint overspray booths are being operated nationwidely, for repair of passenger car body parts. paint aerosols are emitted from the paint overspray booth in operations. In paint overspray booth operations without ventilation system and air pollutants collection unit, it may land on nearby equipment. In this study a removal of sticky paint aerosol for application of the small-scale overspray paint booth. it's cause the surface of filter bag from generated sticky paint aerosol. To remove adhesion of paint aerosol the agglomerating agents are injected and mixed with sticky paint aerosols prior to reach the filter bag. The paint spray rate was set as $10{\pm}5g/min$ from air-atomized spray guns in the spray booth, injection rate of agglomerating was $10{\pm}5g/min$ in the mixing chamber. The filtration velocity including air pollutants varied from 0.2 m/min to 0.4 m/min. Bag cleaning air pressure was set as $5.0kg_f/min$ for detaching dust cake from surface of filter bag. Bag cleaning interval at the filtration velocity of 0.2 m/min was around 3 times longer than that of the 0.4 m/min. The residual pressure drop maintained highest value at the highest filtration velocity. Fractional efficiency of 99.952%~99.971% was possible to maintain for the particle size of 2.5 microns. Total collection efficiency at the filtration velocity of 0.2 m/min was 99.42%. During this study we could confirm high collection efficiency and long cleaning intervals for the test with filtration velocity of 0.2 m/min indicating an optimal value for the given dimensions of the test unit and test operating conditions.

Effect of R-Z Relationships Derived from Disdrometer Data on Radar Rainfall Estimation during the Heavy Rain Event on 5 July 2005 (2005년 7월 5일 폭우 사례 시 우적계 R-Z 관계식이 레이더 강우 추정에 미치는 영향)

  • Lee, GyuWon;Kwon, Byung-Huk
    • Journal of the Korean earth science society
    • /
    • v.33 no.7
    • /
    • pp.596-607
    • /
    • 2012
  • The R-Z relationship is one of important error factors to determine the accuracy of radar rainfall estimation. In this study, we have explored the effect of the R-Z relationships derived from disdrometer data in estimating the radar rainfall. The heavy rain event that produced flooding in St-Remi, Quebec, Canada has been occurred. We have tried to investigate the severity of rain for this event using high temporal (2.5 min) and spatial resolution ($1^{\circ}$ by 250 m) radar data obtained from the McGill S-band radar. Radar data revealed that the heavy rain cells pass directly over St-Remi while the coarse raingauge network was not sufficient to detect this rain event. The maximum 30 min (1 h) accumulation reaches about 39 (42) mm in St-Remi. During the rain event, the two disdrometers (POSS; Precipitation Occurrence Sensor System) were available: One used for the reflectivity calibration by comparing disdrometer Z and radar Z and the other for deriving disdrometric R-Z relationships. The result shows the significant improvement with the disdrometric reflectivity-dependent R-Z relationships against the climatological R-Z relationship. The bias in radar rain estimation is reduced from +12% to -2% and the root-mean squared error from 16 to 10% for daily accumulation. Using the estimated radar rainfall rate with disdrometric R-Z relationships, the flood event was well captured with proper timing and amount.

Organic Matter Dynamics on Golf Course Greens (골프장 그린에서 토섬별 유기물의 경시적 변화)

  • Huh, Keun-Young;Ko, Byong-Gu
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.36 no.3
    • /
    • pp.21-28
    • /
    • 2008
  • The management of soil organic matter(SOM) is a key component of golf course green maintenance. As part of a major project examining the sustainable management of SOM on golf course greens, the SOM status of different age greens maintained in the same root zone composition and management were compared. Then the microbial activity, tiller number, bulk density, water content, pH, EC, and T-N in the soil were measured. In the 0${\sim}$5cm depth SOM accumulation showed no significant difference between greens. Below 5cm SOM showed a strong significance between greens and had a positive(+) correlation with year and negative(-) correlation with depth. when regression equations were used to predict SOM accumulation with year and depth, SOM below 5cm tended to increase with a rate of 0.061% . year$^{-1}$ and decrease with a rate of 0.079% . $cm^{-1}$(R2==0.841). Soil microbial activity was investigated with age and depth by using a dehydrogenase assay. Results showed a sharp drop with depth in all greens. The soil microbial activity below 5cm showed no difference between greens. The accumulated SOM below 5cm may be very resistant to decomposition in the long-term. Five years after establishment, the bulk density did not significantly change. The water content, EC, and T-N had a significant correlation with SOM. The pH decreased with the year, which may influence SOM accumulation. Organic matter accumulation was mainly affected by the pH decrase,low soil microbial activity, and high organic matter resistant to decomposition, but the effects of water content, EC, and T-N were obscure.

Studies on the Maintenance of Bioluminescence from Stored Photobacterium phosphoreum (Photobacterium phosphoreum의 생체발광 유지도에 관한 연구)

  • 김현숙;정성제;전억한
    • Microbiology and Biotechnology Letters
    • /
    • v.28 no.2
    • /
    • pp.117-123
    • /
    • 2000
  • The object of this work is to improve the maintenance of bioluminescence from stored Photobacterium phosphoreum in a view of developing continuous monitoring system for pollutants. The long-term experiments were performed to determine the effect of storage temperature and immobilization on the maintenance of bioluminescence and viability of P. phosphoreum. A naturally luminescent bacterium, P. phosphoreum was starved in 2.5% Nael solution at $20^{\circ}C$, $4^{\circ}C$, -$20^{\circ}C$ and -$70^{\circ}C$ for 30 days. In vivo luminescence was measured by luminometry, and total cell concentrations and concentrations of culturable and viable cells were determined by acridine orange staining, dilution plate counting, and direct viable counting, respectively. The bioluminescence emission from cells stored at 4De was maintained up to 10 days while those with starved cells at other temperature ranges decreased to background level within 3 days. In terms of viability of cells, concentrations of cells stored at $20^{\circ}C$ were rapidly decreased as a result of cell lysis, leading to a drop in culturable and viable counts while cells stored at $4^{\circ}C$ was shown viable but nonculturable state during starvation. With immobilized cells on strontium alginate, the bioluminescence showed higher maintenance than free cells and decreased with count number of nonculturable cells.

  • PDF

Structural Safety Analysis of Openable Working Table in ACP Hot Cell for Spent Fuel Treatment (사용후핵연료 처리를 위한 ACP 실증시설내 개폐형 작업대의 구조적 안전성 평가)

  • Kwon, Kie-Chan;Ku, Jeong-Hoe;Lee, Eun-Pyo;Choung, Won-Myung;You, Gil-Sung;Lee, Won-Kyung;Cho, Il-Je;Kuk, Dong-Hak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.1
    • /
    • pp.17-24
    • /
    • 2006
  • A demonstration facility for advanced spent fuel conditioning process (ACP) is under construction in KAERI. In this hot cell facility, all process equipments and materials are taken in and out only through the rear door. The working table in front of the process rear door is specially designed to be openable for the efficient use of the space. This paper presents the structural safety analysis of the openable working table, for the normal operational load condition and accidential drop condition of heavy object. Both cases are investigated through static and dynamic finite element analyses. The analysis results show that structural safety of the working table is sufficiently assured and the working table is not collapsed even when an object of 500 kg is dropped from the height of 50 cm.

  • PDF

Preliminary Analysis of the CANDU Moderator Thermal-Hydraulics using the CUPID Code (2상 유동 해석코드 CUPID를 이용한 CANDU 원자로 감속재 열수력 예비해석)

  • Park, Sang Gi;Lee, Jae Ryong;Yoon, Han Young;Kim, Hyoung Tae;Jeong, Jae Jun
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.419-426
    • /
    • 2012
  • A transient, three-dimensional, two-phase flow analysis code, CUPID, has been developed in KAERI. In this work, we performed a preliminary analysis using the CUPID code to investigate the thermal-hydraulic behavior of the moderator in the Calandria vessel of a CANDU reactor. At first, we validated the CUPID code using the three experiments that were performed at Stern Laboratories Inc. To avoid the complexity to generate computational mesh around the Calandria tube bundles, a porous media approach was applied for the region. The pressure drop in the porous media zone was modeled by an empirical correlation. The results of the calculations showed that the CUPID code can predict the mixed flow pattern of forced and natural convection inside the Calandria vessel very well. Thereafter, the analysis was extended to a two-phase flow condition. Also, the local maximum temperature in the Calandria vessel was plotted as a function of the injection flow rate, which may be utilized to predict the local subcooling margin.

Study on Cavitation Noise Predictions for an Elliptic Wing (타원형 날개에 대한 공동소음 예측 연구)

  • Jeong, Seung-Jin;Hong, Suk-Yoon;Song, Jee-Hun;Kwon, Hyun-Wung;Park, Il-Ryong;Seol, Han-Shin;Kim, Min-Jae
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.6
    • /
    • pp.757-764
    • /
    • 2019
  • Depressurization occurs around underwater objects moving at high speeds. This causes cavitation nuclei to expand, resulting in cavitation. Cavitation is accompanied by an increase in noise and vibration at the site, particularly in the case of thrusters, and this has a detrimental ef ect on propulsion performance. Therefore, predicting cavitation is necessary. In this study, an analytical method for cavitation noise is developed and applied to an elliptic wing. First, computational fluid dynamics are performed to obtain information about the flow fields around the wing. Then, through the cavitation nuclei density function, number of cavitation nuclei is calculated using the initial radius of the nuclei and nuclei are randomly placed in the upstream with large pressure drop around the wing tip. Bubble dynamics are then applied to each nucleus using a Lagrangian approach for noise analysis and to determine cavitation behavior. Cavitation noise is identified as having the characteristics of broadband noise. Verification of analytical method is performed by comparing experimental results derived from the large cavitation tunnel at the Korea Research Institute of Ships & Ocean Engineering.

Gemological Comparison between Gwangdong Tektite and Baikdusan Obsidian (텍타이트와 흑요석의 보석학적 특징비교 - 중국 광동 텍타이트와 백두산 흑요석을 중심으로 -)

  • Kim, Won-Sa
    • Journal of the Mineralogical Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.181-191
    • /
    • 2007
  • The gemological charateristics of Gwangdong tektites and Baikdusan obsidians were investigated, using microscopy, density and refractive index measurements, X-ray fluorescence spectrometry, Inductively Coupled Plasma Mass spectrometry, X-ray powder diffraction, and electron microprobe analysis. The Gwangdong tektites and Baikdusan obsidians are both black in colour and slightly trans-lucent with various shades of brown when cut into a few mm thick. Both the materials yield conchoidal fracture on broken surface. The tektites occur as tear-drop shapes, ranging from 4 to 10 cm long, and in spheres, from 3 to 5 cm in diameter. On the surface numerous shallow pits up to 3 mm in diameter are present. Mohs' hardness and specific gravity are 5 to 5.5 and 2.66, respectively. The tektites are singly refractive, with an refractive index of 1.51. Numerous spherical air bubbles are randomly scattered throughout the tektites, and silica-rich glass inclusions are occasionally seen. X-ray powder diffraction analysis verifies that they are non-crystalline. The Baikdusan obsidians show very similar properties to those of the Gwangdong tektites, especially in hardness, amorphous nature and fracture. Nevertheless, the Baikdusan obsidian can readily be distinguished from the Gwangdong tektites by refractive index ($1.49{\sim}1.50$), specific gravity (2.67 to 2.68), and inclusions (absence of bubbles and presence of sanidine and magnetite crystals).

A Novel Cooling Method by Acoustic Streaming Induced by Ultrasonic Resonator (초음파 진동자에 의해 유도된 음향유동을 이용한 첨단 냉각법)

  • 노병국;이동렬
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.217-223
    • /
    • 2003
  • A novel cooling method induced by acoustic streaming generated by ultrasonic vibration at 30㎑ is presented. Ultrasonic vibration is obtained by piezoelectric devices and the maximum vibration amplitude of 50 m is achieved by including a horn, mechanical vibration amplifier in the system and making the complete system resonate. To investigate the enhancement of heat transfer capability of acoustic streaming, the temperature variations of heat source and air in the vicinity of heat source are measured in real-time. It is observed that acoustic streaming is instantly induced by ultrasonic vibration, resulting in the significant temperature drop due to the bulk air flow caused by acoustic streaming. In addition, it is observed that the cooling effect on the heat source is maximized when the gap between the ultrasonic vibrator and heat source coincides with the multiples of half-wavelength of the ultrasonic wave. This fact results from the resonance of the sound wave. The theoretical analysis of the dependence on the gap is also accomplished and verified by experiment. The advantage of the proposed cooling method by acoustic streaming is noise-free due to the ultrasonic vibration and maintenance-free because of the absence of moving parts. Moreover. This cooling method can be utilized to the nano and micro-electro mechanical systems, where the fan-based conventional cooling method can not be employed.