• 제목/요약/키워드: DR system

검색결과 533건 처리시간 0.027초

고분자물질 및 계면활성제의 유동마찰 저감 특성 비교 연구 (A Comparison Study on Flow-Friction Characteristic of Polymer Solution and Surfactant as Drag Reduction Additive)

  • 하재순;유재성;김성수;조성환;윤석만;엄재식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.863-868
    • /
    • 2009
  • The drag reduction(DR) for Betaine+Amin and Xantan Gum as kinds of surfactant and Polyacrylamide as kinds of polymer solution according to the fluid velocity, temperature and surfactant concentration were compared experimentally. For this study, two kinds of experimental apparatus for short time and long time measurement were established. Each experimental appratus was equipped with hot water storage tanks, pumps, testing pipe network, flowmeter, two pressure gauges and data logging system was built for them. Results showed that Betaine+Amin and Xanthan Gum as kinds of surfactant had appeared optimal DR around 200-500 ppm and their DR tended to be decreased when flow velocity increased but Polyacrylamide as kinds of polymer solution showed the opposite trend to be increased when flow velocity increased. The both of them showed above 40% DR in the case of better condition by the short term measurement. But Polyacrylamide as kinds of polymer solution showed more degradation than Betaine+Amin and Xanthan Gum as kinds of surfactant by the long term measurement. As a result, Betaine+Amin and Xanthan Gum as kinds of surfactant showed better materials to use to the district heating system.

  • PDF

소규모 분산자원의 효율적 운용을 위한 가상발전소 플랫폼 개발 (A study on the development of a virtual power plant platform for the Efficient operation of small distributed resources)

  • 김희철;홍호표
    • 디지털융복합연구
    • /
    • 제19권11호
    • /
    • pp.365-371
    • /
    • 2021
  • 본 연구에서 고찰되는 가상발전소(VPP; Virtual Power Plant) 솔루션 플랫폼은 전력회사가 발전·송전설비 등의 건설에 소요되는 비용과 이와 관련된 투자리스크를 최소화 한다. 또한, 소비자의 전력 수요를 충족할 수 있도록 수요대응(DR; Demand Response) 프로그램운영 기능을 포함시켜 VPP도입으로 발전 및 송·배전부문에 대한 대규모 설비투자 없이 현존하는 발전기와 DR 프로그램 등을 통해서 소비자의 부하변화에 실시간으로 대처하여 보다 친환경적이고 효율적인 전력공급이 가능하도록 한다. 태양광 및 ESS 연동 장치에 통신 Device를 연동하기 위해서는 Device 장치와 Edge System간 제어·상태에서 데이터를 전달하고 IoT Device 및 연동 플랫폼 개발(OneM2M)이 필요하다.

NC 기계 가공에서의 시스템 통합화 연구 (A study on the system integration for NC machining)

  • 강용근;김기엽
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.167-169
    • /
    • 1990
  • This paper describes the DNC technology as a partial approach to a achieving dr system integration of NC machines. The study deals with development of a system to unify NC machines by utilizing a DNC. The system is provided to have the potential of offering ft environment and application fundamentals to construct factory automation.

  • PDF

다른 온도에서 유전 특성을 통한 사이클로헥산-메틸 아세테이드 바이너리 시스템의 상호관계 (Interaction of Cyclohexane-Methyl Acetate Binary System through Dielectric Properties at Different Temperatures)

  • Kamble, Siddharth P.;Sudake, Y.S.;Patil, S.S.;Khirade, P.W.;Mehrotra, S.C.
    • 대한화학회지
    • /
    • 제55권3호
    • /
    • pp.373-378
    • /
    • 2011
  • 본 논문은288, 298, 308, 318 K에서 구성 요소의 전체 영역에서 이성분 혼합물과 그 특징을 발표하였다. 각각의 다른 온도에서 초과유전상수, 초과 몰 부피, 초과 굴절률, 몰 굴절, 초과 몰 굴절은 실험적으로 측정된 이전의 파라미터 값으로부터 계산되었고 Redlich-Kister 식으로 확인했다. 초과 유전상수, 초과 몰 부피, 초과 몰 편광은 음수인 반면에 초과 굴절률은 모든 온도에 대해 메틸 아세테이드의 전체 몰 분율에서 양수이다. 본 결과는 이성분 혼합물에서 발생하는 분자 사이의 상호작용을 고려하여 논의 되었다. Redlich-Kister 다항식의 예측된 계수와 계수에 따른 표준오차 또한 보고되었다.

X선 기기의 자동화를 위한 BLDC 모터 제어 장치 (BLDC Motor Control Unit for Automation of X ray Equipment)

  • 김태곤;김영표;천민우
    • 한국항행학회논문지
    • /
    • 제15권5호
    • /
    • pp.833-838
    • /
    • 2011
  • 진단용 X선 기기는 다양한 장치의 개발에 힘입어 보다 효과적이고 정밀한 진단이 가능하게 되었다. 정밀 진단이 가능하게 되면서 X선 기기는 임상의학에 있어 가장 기본적이고 핵심적인 진단 장치로 자리 잡고 있다. X선을 이용한 영상획득 분야에서는 영상의 획득 시간 단축과 전송이 용이하고, 조사선량의 감소가 가능한 DR(Digital Radiography)의 사용이 확대되고 있다. 하지만 DR은 1개의 디텍터를 이용하는 구조로 되어있어 기존의 X선 장치와는 달리 구조적인 변경이 필요하며 촬영위치에 따라 디텍터를 원하는 위치까지 움직여야하는 단점을 가진다. 따라서 본 연구에서는 BLDC 모터와 PID 제어방식을 사용해 DR에서 가장 움직임이 많은 디텍터의 상하, 좌우, 회전의 3축 위치자동 제어 시스템을 설계 제작하고 그 성능을 평가 하였다.

무선 센서 네트워크에서 1-2-1 협력 프로토콜에 관한 연구 (Performance Analysis of 1-2-1 Cooperative Protocol in Wireless Sensor Networks)

  • 최대규;공형윤
    • 한국인터넷방송통신학회논문지
    • /
    • 제8권5호
    • /
    • pp.113-119
    • /
    • 2008
  • 기존의 1-1-1 협력 프로토콜은 멀티 홉이 가지고 있는 경로손실감소 이득과 함께 MIMO와 동일한 공간 다이버시티를 제공한다. 이를 통해 싱글 홈, 멀티 홉보다 뛰어난 정보의 신뢰도 및 에너지 소비 감소를 얻을 수 있다. 하지만 기존의 1-1-1 협력 프로토콜은 단일의 협력 중계기를 사용하므로 경로손실감소 이득과 다이버시티 이득 계수가 2로 제한되어 있다. 따라서 본 논문에서는 두개의 협력 중계기 R1, R2를 사용한 1-2-1 협력 프로토콜을 제안한다. 1-2-1 협력 프로토콜은 경로손실감소 이득을 높이고 계수가 3인 다이버시티 이득을 얻는다. 또한, 협력 중계가 R2에서도 계수가 2인 다이버시티 이득을 얻을 수 있다. 협력 중계기는 DF (Decode and Forward)와 DR (Decode and Reencode) 방식을 사용하여 1-2-1 DF 또는 DR 협력 프로토콜을 형성하고, 클러스터링 기반의 무선 센서 네트워크 (WSNs)에 적용한다. 제안한 프로토콜의 성능평가를 위해 레일리 페이딩과 AWGN (Additive White Gaussian Noise) 채널이 합해진 채널에서 모의실험을 한다.

  • PDF

Dr. Speech Science를 이용한 정상 및 후두질환 환자의 음향분석 (Acoustic Analysis of Normal and Vocal Pathologic Voice Using Dr. Speech Science)

  • 이형석;태경;장경진;김경우;김경래;박철원
    • 대한후두음성언어의학회지
    • /
    • 제8권2호
    • /
    • pp.166-172
    • /
    • 1997
  • Background : For example, aerodynamic study, vibratory study, acoustic study, neuro-muscular test and psychoacoustic evaluation, a number of objective methods are now available for assessing pathologic voice change. They help to differentiate pathologic condition from normal condition and to monitor pathologic and aging change. These laboratory analyses are used commonly to monitor speech therapy and to follow a patient's recovery after surgery. Objectives : We investigated the values of jitter, shimmer and NNE of normal person and hoarseness patients in Korea. The values of Jitter and shimmer might be meaningful parameters distinguishing pathologic vibration from normal and recovery after surgery. Materials and Methods : Statistical significance between normal control and 48 subjects taken microlaryngeal surgery were compared with Dr. speech science program that is computerized system for acoustic analysis of voice production employed to determine vocal characteristics of pitch perturbation(jitter) and amplitude perturbation(shimmer). Results : The mean normal values of jitter and shimmer were 0.226${\pm}$0.110(%), 2.200${\pm}$0.421(%) in male and 0.164${\pm}$0.060(%), 2.063 ${\pm}$0.575(%) in female. In patients with vocal nodule, the preoperative and postoperative values of jitter and shimmer were valueless. In patients with vocal polyps, the preoperative and postoperative values of jitter and shimmer were valuable. Conclusion : Dr. speech science program was effective to monitor laryngeal disease and aging changes.

  • PDF

3차원 R-트리를 이용한 이동체 색인에 관한 연구 (A Study on Indexing Moving Objects using the 3D R-tree)

  • 전봉기
    • 한국컴퓨터정보학회논문지
    • /
    • 제10권4호
    • /
    • pp.65-75
    • /
    • 2005
  • 이동체 데이터베이스는 연속적으로 이동하는 이동체의 위치와 궤적을 검색하기 위한 데이터베이스 질의를 효과적으로 처리해야 한다. 질의 처리의 성능 향상을 위하여, 연속적으로 이동하는 이동체를 위한 효과적인 색인 기법이 필요하다. 3D R-tree와 TB-tree는 현재 위치에 대한 영역 질의를 처리할 수 없다. 현재와 과거 위치에 대한 영역 질의를 처리하기 위하여, 기존의 3D R-tree를 태그 now를 가지도록 수정하였다. 대부분의 시공간 색인 구조들은 이동체의 과거 위치에 대한 영역 질의를 효과적으로 처리할 수 없다. 이와 같은 쟁점을 설명하기 위하여 기존의 3D R-tree를 기반으로 하는 TA3DR-tree이라 불리는 색인 방법을 제안한다. TA3DR-tree는 기존의 3D R-tree와 TB-tree와의 성능 평가의 우수한 성능 결과를 보였다.

  • PDF

A Stochastic Bilevel Scheduling Model for the Determination of the Load Shifting and Curtailment in Demand Response Programs

  • Rad, Ali Shayegan;Zangeneh, Ali
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1069-1078
    • /
    • 2018
  • Demand response (DR) programs give opportunity to consumers to manage their electricity bills. Besides, distribution system operator (DSO) is interested in using DR programs to obtain technical and economic benefits for distribution network. Since small consumers have difficulties to individually take part in the electricity market, an entity named demand response provider (DRP) has been recently defined to aggregate the DR of small consumers. However, implementing DR programs face challenges to fairly allocate benefits and payments between DRP and DSO. This paper presents a procedure for modeling the interaction between DRP and DSO based on a bilevel programming model. Both DSO and DRP behave from their own viewpoint with different objective functions. On the one hand, DRP bids the potential of DR programs, which are load shifting and load curtailment, to maximize its expected profit and on the other hand, DSO purchases electric power from either the electricity market or DRP to supply its consumers by minimizing its overall cost. In the proposed bilevel programming approach, the upper level problem represents the DRP decisions, while the lower level problem represents the DSO behavior. The obtained bilevel programming problem (BPP) is converted into a single level optimizing problem using its Karush-Kuhn-Tucker (KKT) optimality conditions. Furthermore, point estimate method (PEM) is employed to model the uncertainties of the power demands and the electricity market prices. The efficiency of the presented model is verified through the case studies and analysis of the obtained results.

Efficiency of MVP ECG Risk Score for Prediction of Long-Term Atrial Fibrillation in Patients With ICD for Heart Failure With Reduced Ejection Fraction

  • Levent Pay;Ahmet Cagdas Yumurtas;Ozan Tezen;Tugba Cetin;Semih Eren;Goksel Cinier;Mert Ilker Hayiroglu;Ahmet Ilker Tekkesin
    • Korean Circulation Journal
    • /
    • 제53권9호
    • /
    • pp.621-631
    • /
    • 2023
  • Background and Objectives: The morphology-voltage-P-wave duration (MVP) electrocardiography (ECG) risk score is a newly defined scoring system that has recently been used for atrial fibrillation (AF) prediction. The aim of this study was to evaluate the ability of the MVP ECG risk score to predict AF in patients with an implantable cardioverter defibrillator (ICD) and heart failure with reduced ejection fraction in long-term follow-up. Methods: The study used a single-center, and retrospective design. The study included 328 patients who underwent ICD implantation in our hospital between January 2010 and April 2021, diagnosed with heart failure. The patients were divided into low, intermediate and high-risk categories according to the MVP ECG risk scores. The long-term development of atrial fibrillation was compared among these 3 groups. Results: The low-risk group included 191 patients, the intermediate-risk group 114 patients, and the high-risk group 23 patients. The long-term AF development rate was 12.0% in the low-risk group, 21.9% in the intermediate risk group, and 78.3% in the high-risk group. Patients in the high-risk group were found to have 5.2 times higher rates of long-term AF occurrence compared to low-risk group. Conclusions: The MVP ECG risk score, which is an inexpensive, simple and easily accessible tool, was found to be a significant predictor of the development of AF in the long-term follow-up of patients with an ICD with heart failure with reduced ejection fraction. This risk score may be used to identify patients who require close follow-up for development and management of AF.