• Title/Summary/Keyword: DR system

Search Result 528, Processing Time 0.029 seconds

The Effects of Total Variation (TV) Technique for Noise Reduction in Radio-Magnetic X-ray Image: Quantitative Study

  • Seo, Kanghyen;Kim, Seung Hun;Kang, Seong Hyeon;Park, Jongwoon;Lee, Chang Lae;Lee, Youngjin
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.593-598
    • /
    • 2016
  • In order to reduce the amount of noise component in X-ray imaging system, various reduction techniques were frequently used in the field of diagnostic imaging. Although the previous techniques -such as median, Wiener filters and Anscombe noise reduction technique - were able to reduce the noise, the edge information was still damaged. In order to cope with this problem, total variation (TV) noise reduction technique has been developed and researched. The purpose of this study was to evaluate and compare the image quality using normalized noise power spectrum (NNPS) and contrast-to-noise ratio (CNR) through simulations and experiments with respect to the above-mentioned noise reduction techniques. As a result, not only lowest NNPS value but also highest CNR values were acquired using a TV noise reduction technique. In conclusion, the results demonstrated that TV noise reduction technique is proved as the most practical method to ensure accurate denoising in X-ray imaging system.

A Normative Review on Non-Invasive Prenatal Diagnosis (NIPD): Focusing on the German Discussion on PrenaTest®

  • Kim, Na-Kyoung
    • Development and Reproduction
    • /
    • v.25 no.2
    • /
    • pp.113-121
    • /
    • 2021
  • This article aims to introduce German discussion on the approval of the non-invasive prenatal diagnosis (NIPD), which started with the development of PrenaTest® by LifeCodexx AG. The discussion started with the concern that the non-invasive nature of NIPD, such as PrenaTest®, may rapidly expand the use and scope of similar tests, thus leading to a new era of eugenics. Based on this concern, the need for clear clinical guidelines on specific indications for NIPD has been suggested. Along the same line, it was discussed whether PrenaTest® is against the Basic Law prohibiting discrimination on grounds of disability and whether the test is outside the scope of the purpose of gene testing limited by Genetic Diagnosis Act. Through such discussion, the Federal Ministry of Health of Germany established the preconditions for inclusion of NIPD in the German public health insurance system. For this, the German motherhood guideline was amended and the information for the insured persons provided to pregnant women was included in the amended guideline. Such discussion made in Germany provides insight on which points should be considered when various gene testings are accepted in Korea, in which genetic communication has not been systematized yet. In particular, German counseling system for pregnant women will provide valuable insights for Korea where the direction for regulations on abortion has not been established even after the ruling by the Constitutional Court that charges for abortion are against the constitution.

Expression of Kisspeptin in the Adult Hamster Testis

  • Park, Jin-Soo;Cheon, Yong-Pil;Choi, Donchan;Lee, Sung-Ho
    • Development and Reproduction
    • /
    • v.26 no.3
    • /
    • pp.107-115
    • /
    • 2022
  • Kisspeptins, products of KISS1 gene, are ligands of the G-protein coupled receptor (GPR54), and the kisspeptin-GPR54 signaling has an important role as an upstream regulator of gonadotropin releasing hormone (GnRH) neurons. Interestingly, extrahypothalamic expressions of kisspeptin/GPR-54 in gonads have been found in primates and experimental rodents such as rats and mice. Hamsters, another potent experimental rodent, also have a kisspeptin-GPR54 system in their ovaries. The presence of testicular kisspeptin-GPR54 system, however, remains to be solved. The present study was undertaken to determine whether the kisspeptin is expressed in hamster testis. To do this, reverse transcription-polymerase chain reactions (RT-PCRs) and immunohistochemistry (IHC) were employed. After the nest PCR, two cDNA products (320 and 280 bp, respectively) were detected by 3% agarose gel electrophoresis, and sequencing analysis revealed that the 320 bp product was correctly amplified from hamster kisspeptin cDNA. Modest immunoreactive (IR) kisspeptins were detected in Leydig-interstitial cells, and the weak signals were detected in germ cells, mostly in round spermatids and residual bodies of elongated spermatids. In the present study, we found the kisspeptin expression in the testis of Syrian hamster. Further studies on the local role(s) of testicular kisspeptin are expected for a better understanding the physiology of hamster testis, including photoperiodic gonadal regression specifically occurred in hamster gonads.

Nationwise Survey of the X-ray Beam Collimator Utilization in General Diagnostic Radiograph (진단방사선 일반촬영에서의 X-ray Beam Collimator 사용 전국 실태조사)

  • Kim, Jee Hye;Sung, Dong-Wook;Kim, Jeong Wook;Shin, Jin Ho;Lee, Soon Keun;Jung, Kyung Il;Uhm, Jong Kwan;Lee, Ki Nam;Seong, Ho Jin;Kim, Youn Hyun;Kim, Hyeog Ju
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.119-126
    • /
    • 2013
  • Due to the introduction of CR and DR, it has been neglected the use of the X-ray beam collimator and field size. This study examines nationwide survey of the proper use of collimator and field size by area in a specific field of plain radiography and the current status. Authors emphasized the need for the field size criteria, and propose a standard reference field size in each specific radiologic examination. Total 333 medical institutions (included in Seoul, Gyeonggi-do, Jeolla, Chungcheong, Gangwon-do, Busan area), were investigated in relation to the status of the X-ray beam collimation field size, type specific inspection areas, medical facilities, and image analyses by type to figure out whether they use the adjustment of image field to the specific examination. To assess the awareness and the impact of radiation exposure to the collimation adjustable, 168 radiographers who was working in 10 general hospitals, 10 hospitals, and 10 clinics, were surveyed how they haver adjusted the actual field size. We examine that 61.3% of medical institutions used the "Proper collimation" and only 49.9% of them employed proper one in lumbar spine densely crowded by major organs. 69% among general hospitals, and 65% among hospitals using DR system were using proper collimation. Radiographers recognized that proper adjustment of collimation could reduce the harmful radiation dose on patients. In the survey, 97.6% of respondents were aware of this fact, but only 83.3% of respondents did the adjustment of the size of the collimation field. The using of proper collimation field was low in the nationwide survey, so the effort to reduce the radiation dose on the patients is urgently needed. A unified standard for the field accompanied by thorough education should be needed.

Design of Digitalized SECAM Video Encoder with Modified Anti-cloche filter and SECAM Video Decoder with BPF and Error-free Square Root (개선된 Anti-cloche Filter와 BPF 그리고 오차가 없는 제곱근기를 사용한 SECAM Encoder와 Decoder의 설계)

  • Ha, Joo-Young;Kim, Joo-Hyun;Kang, Bong-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.3
    • /
    • pp.511-516
    • /
    • 2006
  • In this raper, we propose the Sequentiel Couleur Avec Memoire or Sequential Color with Memory (SECAM) video encoder system using modified anti-cloche filters and the SECAM video decoder system using a band pass filter (BPF) and an error-free square root. The SECAM encoder requires an anti-cloche filter recommended by International Telecommunication Union-Recommendation (ITU-R) Broadcasting service Television (BT) 470. However, the design of the anti-cloche filter is difficult because the frequency response of the anti-cloche filter is very sharp around rejection-frequency area. So, we convert the filter into a hish pass filter (HPF) by shifting the rejection frequency of 4.286MHz to 0Hz frequency. The design of HPF becomes very easy, compared to that of the anti-cloche filter. The proposed decoder also uses an error-free square root, two differentiators and trigonometric functions to extract color-component information of Db and Dr accurately from frequency modulation (FM) signals in SECAM systems. Also, the BPF in decoder it used for removing color noise in chrominance and dividing CVBS into chrominance and luminance. The proposed systems are experimentally demonstrated with Altera FPGA APEX20KE EP20K1000EBC652-3 device and TV sets.

In-vitro Production of Glutathione Using Yeast ATP Regeneration System and Recombinant Synthetic Enzymes from Escherichia coli. (효모의 ATP 재생산계와 대장균 유래의 재조합 생산효소를 이용한 in vitro 글루타치온 생산)

  • 고성영;구윤모
    • Microbiology and Biotechnology Letters
    • /
    • v.26 no.3
    • /
    • pp.213-220
    • /
    • 1998
  • An ATP regeneration system was used for the production of glutathione which was synthesized by a sequential action of ${\gamma}$-glutamyl-cysteine synthetase and glutathione synthetase. The synthetases above were produced in the recombinant E. coli (TG1/pDG7) with the highest specific production yield of 31 mg glutathione/g wet cell. Bakers yeast was considered to have economically a better ATP regeneration system although the glutathione production yield was lower than that of acetate kinase. It was also observed that the ATP regeneration system of bakers yeast was superior to that of Saccharomyces cerevisiae ATCC24858. The yield of glutathione production with bakers yeast was 36% with the ATP concentration of 5 mM. To avoid the cysteine limitation during the early phase of glutatione production, an extra cysteine was added at 2 hours after reaction and the production yield increased 1.91 times. The effectiveness of bakers yeast as an ATP regeneration system was proved by several sets of extra feeding experiments. The product inhibition by glutathione above 14 mM was also observed.

  • PDF

Image System Using Dual Energy Detector (이중 에너지 검출기를 이용한 영상 시스템)

  • Yeo, Hwa-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3517-3523
    • /
    • 2010
  • Single exposure dual X-ray imaging can be used to separate soft and dense-material images for medical and industrial applications. This study keep focusing baggage inspection system(BIS) specifically. New detector modules for single exposure dual X-ray imaging are consisted of low energy detector (LED) and high energy detector (HED). First, the optimized thickness of copper filter coupled HED to separate low energy and high energy was simulated by the given X-ray energy (140 kVp, 1 mA) using Monte Carlo simulation codes, MCNPX. So as a result of simulation, the copper filter thickness is 0.7 mm. For the design of PIN photodiode, ATLAS device simulation tool was used. 16 channels PIN photodiode of 1.5 mm ${\times}$ 3.2 mm for Dual X-ray imaging detector was fabricated in the process of ETRI. And its dark current and quantum efficiency, terminal capacitance were measured. It was proven that the Lanex Fast B coupled HED were a sufficient candidate to replace the CsI(Tl) commerced in dual X-ray system, since these give a strong signal, overcoming system noise. Finally dual X-ray image was acquired through correction of the LED X-ray Image and the HED X-ray Image.

Interconnection Capacity Evaluation of Distributed Resources at the Distribution Networks in View of Distribution Protection Coordination (배전계통의 보호협조측면에서 본 분산전원 연계용량 검토)

  • Choi, Joon-Ho;Ro, Kyoung-Soo;Park, Sung-Jun;Song, Kyung-Bin;Yun, Sang-Yun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.107-116
    • /
    • 2007
  • The introduction of new renewable energy is going on increase with the second plan of the Korean Government "Technology Development, Utilization and Popularization of New Renewable Energy". In general, it is connected to the power system due to the nature of it's source characteristics but it's interconnection operation impacts on the power system planning and operation. The operation schemes of the existing power distribution system are based on the unidirectional power flow, but unidirectional power flow changes to bidirectional power flow due to the interconnection operation of new renewable energy. It degrade the existing protection coordination system and power quality of the power distribution system. Thus, the technical evaluation process of the interconnection of new renewable energy are necessary. In this paper, the characteristics of the existing automatic recloser and sectionalizer are reviewed and interconnection capacity evaluation method of the DR(distributed resources) in the existing automatic recloser-sectionalizer protective coordination system are proposed.

Preliminary Study for Development of System for Oriental Nurse-specialist (한방전문간호사제도를 위한 예비조사)

  • Baek, Ji-Young
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.7 no.2
    • /
    • pp.275-284
    • /
    • 2001
  • This study was conducted to examine the nurses' role in Oriental medical hospital and the necessity of Oriental medical nursing system. Data were collected from 194 nurses in 14 Oriental medical hospitals located in Seoul, Busan, Daegu, Kwangju, Kangwon Province, Kyungbuk Province from July 1, 2000 to September 10, 2000. The results of this study are summarized as follows. 1. In nurse's level of knowledge of acupuncture point in current Oriental nursing practice, 28.4% of the respondents did not know acupuncture points at all, while 30.9% knew them a little. 40.7% of them did not almost know them. 2. According to nurses' role in Oriental medical hospital, they did a lot of duty for measurement of vitality, medical record, Dr. notifying, communication with medical team and related departments, and observation of patients' conditions. They did a little duty for handling Oriental medical practice. 3. As the subject of curriculum for Oriental medical nursing, 52.1% chose training course for Oriental medical nursing, while 25.8% chose inclusion of the curriculum in the school of nursing. 39.2% replied that they would take the training course for Oriental medical nursing, while 3.6% answered that they would not take it. 68.6% of them thought that Oriental medical nursing system should be introduced, while 4.1% objected to introducing the system. The nurses in Oriental medical hospitals are working with many problems because of their role confusion and low level of knowledge in Oriental medicine. Therefore, systematic curriculum and research related to Oriental medical nursing are necessary. Oriental medical nursing system must be introduced in order to make nurses have professional knowledge and skill in Oriental medicine. The nurses then can provide services of good quality for the patients.

  • PDF

Evaluation of Drought Effect on Groundwater System using Groundwater Level Data in Jeju Island (지하수위 자료를 이용한 제주도 지하수계의 가뭄 영향 평가)

  • Song, Sung-Ho;Lee, Byung-Sun;Choi, Kwang-Jun;Kim, Jin-Sung;Kim, Gi-Pyo
    • Journal of Environmental Science International
    • /
    • v.23 no.4
    • /
    • pp.637-647
    • /
    • 2014
  • Quantitative assessment of groundwater level change under extreme event is important since groundwater system is directly affected by drought. Substantially, groundwater level fluctuation reveals to be delayed from several hours to few months after raining according to the aquifer characteristics. Groundwater system in Jeju Island would be also affected by drought and almost all regions were suffered from a severe drought during summer season (July to September) in 2013. To estimate the effect of precipitation to groundwater system, monthly mean groundwater levels in 2013 compared to those in the past from 48 monitoring wells belong to be largely affected by rainfall(Dr) over Jeju Island were analyzed. Mean groundwater levels during summer season recorded 100 mm lowered of precipitation compared to the past 30 years became decreased to range from 2.63 m to 5.42 m in southern region compared to the past and continued to December. These decreasing trends are also found in western(from -1.21 m to -4.06 m), eastern(-0.91 m to -3.24 m), and northern region(from 0.58 m to -4.02 m), respectively. Moreover, the response of groundwater level from drought turned out to be -3.80 m in August after delaying about one month. Therefore, severe drought in 2013 played an important role on groundwater system in Jeju Island and the effect of drought for groundwater level fluctuation was higher in southern region than other ones according to the regional difference of precipitation decrease.