• Title/Summary/Keyword: DOPPLER

Search Result 2,266, Processing Time 0.029 seconds

Novel Doppler effects compensation schemes based on constellation estimation of OFDM system

  • Lee, Byung-Seub
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.2
    • /
    • pp.79-82
    • /
    • 2017
  • A new and effective Doppler effects compensation scheme for orthogonal frequency division multiplex(OFDM) system based on constellation estimation is presented with analytical descriptions which quantitatively clarify the mechanism of inter-carrier interference(ICI). The proposed compensation techniques, applicable both frequency and time domain with remarkable accuracy, are crucial to the future OFDM system operating on ultra high speed mobile vehicles.

The Technique and Normal Values of Transcranial Doppler Ultrasonography(TCD) (Transcranial Doppler Ultrasonography (TCD)의 시행 방법 및 정상치)

  • Sohn, Young Ho
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.1
    • /
    • pp.39-46
    • /
    • 1999
  • Transcranial doppler ultrasonography (TCD) is a new, non-invasive and easily applicable method to evaluate cerebral hemodynamics. Last 10 years, its use in Korea has been dramatically expanded, but the qualification of TCD laboratory has yet to be settled. Since duplex sonography is seldom used in Korea, we have to depend totally on TCD to evaluate cerebral hemodynamic changes. Thus, all of the available data from every detectabler cerebral arteries has to be obtained for accurate interpretation of TCD measurements. Moreover, flow direction and wave form should be concerned in addition to the flow velocity. In this article, I present technique to measure the anterior, meddle and posterior cerebral arteries, the internal carotid artery siphon and at cervical level, and the vertebral and the basilar artery, and normal values for these measurements which is essential for the adequate interpretation.

  • PDF

An Analysis and a 3D Prediction of vibration modes in a Laser Doppler (레이저 도플러의 진동에 대한 분석과 3차원 예측연구)

  • Baik, Ran
    • Journal of Digital Contents Society
    • /
    • v.11 no.2
    • /
    • pp.117-122
    • /
    • 2010
  • This is a study on the analysis of vibration mode of a laser doppler. We measure the vibration mode of a doppler and analyze each component, and want to estimate three dimensional properties from 2-dimensional data. The vibration mode relies on a range detector that uses a distance sensor. Since the outputs are determined by the measured distance, we want to study how 3-dimensional vibration mode is generated from 2-dimensional ones. The study will include the patterns of generating a 3-dimensional vibration mode as well as the relationship between the distance and the vibration mode.

A Study on the Uncertainty of MVRS (포구속도측정레이더의 불확도에 관한 연구)

  • Park, Yong-Suk;Choi, Ju-Ho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.94-100
    • /
    • 2007
  • MVRS's measuring principles are based on the Doppler principle. It measures the velocities near the muzzle using the doppler signal output from the antenna and then predicts the velocity of the bullet leaving the muzzle by performing the regression analysis on previous measured velocities. There are a number of error sources when calculating the muzzle velocity. Antenna has long term frequency stability error and the doppler signal from the antenna has noise. These two error sources influence the accuracy of estimated velocities from the doppler signal. Estimated velocity errors result in the random error of data statistics. And when performing a regression analysis these random error components are transferred to the fitting error component. This study also analyzed the error components according to the hardware limitations of MVRS-700 and the signal processing method, and presented the calculated uncertainty of muzzle velocity.

Effects of chemical restraint drugs on Doppler echocardiography in normal dogs (화학적 보정약이 정상견의 도플러 심초음파에 미치는 영향)

  • Yoon, Jung-hee
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.2
    • /
    • pp.413-418
    • /
    • 1998
  • Intracardiac velocities were determined and the wave-forms described for 4 flow areas of the normal canine heart following administration of chemical restraint drugs including xylazine HCl, ketamine HCl, and thiopental sodium using pulsed wave Doppler echocardiography. The result was that xylazine HCl and thiopental sodium reduced intracardiac flow velocities through mitral, tricuspid, aortic and pulmonary valves. It is also thought that precautions are required before using these drugs. Patterns of wave-forms had no changes between control and treatment groups. Doppler echocardiography allows the clinician to determine flow velocities across the different valves and within the various chambers of the heart. It is shown that establishing normal values and those related to chemical restraint administrations and knowing what influences them should allow the clinician to non-invasively diagnose a variety of pathological cardiac conditions.

  • PDF

GNSS Precise Positioning Design for Intelligent Transportation System (지능형 교통시스템에 적합한 위성항법 기반의 정밀측위 구조 설계)

  • Lee, Byung-Hyun;Im, Sung-Hyuck;Heo, Moon-Beom;Jee, Gyu-In
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.11
    • /
    • pp.1034-1039
    • /
    • 2012
  • In this paper, a structure of precise positioning based on satellite navigation system is proposed. The proposed system is consisted with three parts, range domain filter, navigation filter and position domain filter. The range domain filter generates carrier phase-smoothed-Doppler and Doppler-smoothed-code measurements. And the navigation filter calculates position and velocity using double-differenced code/carrier phase/Doppler measurements. Finally, position domain filter smooth position error, and it means enhancement of positioning performance. The proposed positioning method is evaluated by trajectory analysis using precise map date. As a result, the position error occurred by multipath or cycle slip was reduced and the calculated trajectory was in true lane.

High Resolution Pitch Determination Algorithm for Fetal Heart Rate Extraction (태아심음주기의 검출을 위한 고해상 피치 검출 알고리즘)

  • 이응구;이두수
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.2
    • /
    • pp.80-87
    • /
    • 1994
  • Fetal monitoring is a routine procedure to obtain a record of physiologic functions during pregnancy and labor. It is required to determine fetal heart frequency accurately. There are various types of fetal heart rate(FHR) determination and the most frequently applied method is transabdominal Doppler ultrasound. However, in the case of weak or noise corrupted Doppler ultrasound signals, conventional peak detections and the autocorrelation function method have many difficulties to determine FHR precisely. Also the autocorrelation function is effected by threshold level and window size. To solve these problems, the high resolution pitch determination algorinthm is introduced to detect FHR from Doppler ultrasound signals. This scheme digitally processes Doppler ultrasound signal for digital rectification, envelope detection, decimation and correlation calculation of two interconnected segments and then FHR is determined by its maximal value. Even in the case of a greatly smeared noise signal, this algorithm is able to search FHR more accurately than autocorrelation function by means of compensating FHR with a constant correlation threshold. This algorithm is simulated by 386-MATLAB on PC 486/DX and verified that it is superior to the autocorrelation function method.

  • PDF

Blood Flow in an Aortic Bifurcation Model: Pulsed Doppler Ultrasound and Laser Doppler Anemometry Studies (대동맥분기에서의 혈액유동: 맥도플러초음파 및 레이저도플러계측기를 사용한 연구)

  • Kim, Young-H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.11
    • /
    • pp.43-46
    • /
    • 1992
  • $\underline{In\;vitro}$ velocity measurements were made using both the pulsed Doppler ultrasound (PDU) machine and laser Doppler anemometer (LDA) system in order to investigate the flow characteristics near the aortic bifurcation. Velocities measured from the PDU machine was in good agreement with those from the LDA. The flow in the daughter branches was three-dimensional with a secondary flow. The oscillating wall shear stress with this secondary fluid motion is well correlated with the localization of the atherosclerosis.

  • PDF

Analysis of Field Noise from High Speed Train Using Dedopplerization (도플러 보정을 통한 고속열차 현장 측정 소음 분석)

  • Lee, Yong Woo;Lee, Duck Joo;Kwon, Hyeok Bin;Yun, Su Hwan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.5
    • /
    • pp.431-437
    • /
    • 2013
  • Measured acoustic signal from operating high speed train contains frequency change called doppler shift due to its motion. To avoid this doppler shift wind tunnel test is required. But scaledown of model can cause change of source characteristics. And measurements using some part of train cannot reproduce real flow condition. The best way to recognize real noise source characteristics is measurement from operating high speed train but doppler shift makes it hard. So, we developed simple dedopplerization technique for one microphone and applied to field test data of high speed train. Through this, we could capture real frequency of noise from operating high speed train.

A Continuous Scanning Laser Doppler Vibrometer for Mode Shape Analysis (모드형상분석을 위한 연속 스캐닝 레이저 도플러 진동측정기)

  • 라종필;최지은;박기환;경용수;왕세명;김경석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.274-280
    • /
    • 2002
  • This paper addresses the vibration mode shape measurement technique utilizing a Continuous Scanning Laser Doppler Vibrometer (CSLDV). The continuous scanning capability is added to the conventional discrete Laser Doppler Vibrometer by reflecting the laser beams on the surface of the object using two oscillating mirrors. The bow scanning resulted from the proposed scanning method is eliminated by feedback control. The velocity output signal from the CSLDV is modulated to give the spatial velocity distribution in terms of coefficients which are obtained from the Fast Fourier Transformation of the time dependent velocity signal. Using the Chebyshev series form, the analysis of the vibration mode shape techniques for straight Bine scanning and 2 dimensional scanning are presented and discussed. The performance of the proposed SLDV is presented using the experimental results of the vibration mode shape of a plate

  • PDF