• Title/Summary/Keyword: DOPPLER

Search Result 2,266, Processing Time 0.029 seconds

Design and Performance Evaluation of MIMO(Multiple Input Multiple Output) System Using OTFS(Orthogonal Time Frequency Space) Modulation (OTFS(Orthogonal Time Frequency Space) 변조를 사용하는 MIMO(Multiple Input Multiple Output) 시스템 설계와 성능 평가)

  • An, Changyoung;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.6
    • /
    • pp.444-451
    • /
    • 2017
  • In this paper, we have evaluated and analyzed OTFS(Orthogonal Time Frequency Space) modulation and OTFS-MIMO(Multiple Input Multiple Output) system. OTFS modulation can concisely compensate delay-Doppler spreading effect by using 2D(2-Dimension) iDFT (inverse Discrete Fourier Transform) and DFT(Discrete Fourier Transform) operation. It enables OTFS system to transmit high-speed data. Especially, OTFS-MIMO system can transmit all data streams without performance degradation on high Doppler frequency channel. As simulation results, we have confirmed that $1{\times}1$ OTFS system's achievable rate is a similar to each stream of $2{\times}2$ OTFS-MIMO system. That is, we have also confirmed that $2{\times}2$ MIMO system can completely achieve double achievable rate in comparison with OTFS system on high Doppler frequency channel.

Volumetric Blood Velocity Measurement on Multigate Pulsed Doppler System based on the Single Channel RF Sampling using the Optimized Sampling Factor (최적화된 샘플링 인수를 갖는 단일 채널 RF 샘플링 방식의 다중점 펄스 도플러 시스템을 사용한 혈류 속도분포 측정)

  • 임춘성;민경선
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.143-152
    • /
    • 1998
  • In this paper, we present the performances of a Doppler system using single channel RF(Radio Frequency) sampling. This technique consists of undersampling the ultrasonic blood backscattered RF signal on a single channel. Conventional undersampling method in Doppler imaging system have to use a minimum of two identical parallel demodulation channels to reconstruct the multigate analytic Doppler signal. However, this system suffers from hardware complexity and problem of unbalance(gain and phase) between the channels. In order to reduce these problems, we have realized a multigate pulsed Doppler system using undersampling on a single channel, It requires sampling frequency at $4f_o$(where $f_o$ is the center frequency of the transducer) and 12bits A/D converter. The proposed " single-Channel RF Sampling" method aims to decrease the required sampling frequency proportionally to $4f_o$/(2k+1). To show the influence of the factor k on the measurements, we have compared the velocity profiles obtained in vitro and in vivo for different intersequence delays time (k=0 to 10). We have used a 4MHz center frequency transducer and a Phantom Doppler system with a laminar stationary flow. The axial and volumetric velocity profiles in the vessel have been computed according to factor k and have been compared. The influence of the angle between the ultrasonic beam and the flow axis direction, and the fluid viscosity on the velocity profiles obtained for different values of k factor is presented. For experiment in vivo on the carotid, we have used a data acquisition system with a sampling frequency of 20MHz and a dynamic range of 12bits. We have compared the axial velocity profiles in systole and diastole phase obtained for single channel RF sampling factor.ng factor.

  • PDF

Removal of Clutter from Doppler Radar Signal to Measure Accurate Muzzle Velocity (도플러 레이더를 이용한 포구속도 계측 시 클러터 제거 방법)

  • Kim, Hyoung-rae
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.2
    • /
    • pp.142-150
    • /
    • 2019
  • Muzzle Velocity is one of the most important measurement items for evaluation of ammunition. The muzzle velocity is defined as the velocity when the projectile leaves the muzzle. Particularly, since the muzzle velocity is closely related to the performance of the propellant, precise measurement of muzzle velocity is required. Doppler radar is used to measure the muzzle velocity, but the quality of Doppler radar signal depends on the test site environment. In this paper, a method to remove the clutter that degrades the signal quality of Doppler radar by improving the structure of the test site and the signal processing method is suggested. For the application of the improved signal processing method, a program for acquiring Doppler radar's raw Doppler data was created. Statistical verification of the velocity data obtained through the improvement of the test site structure and signal processing method proved that the proposed method is effective for the removal of clutter as compared with the existing method.

A Review of the Study Trends on the Relationship between Primary Dysmenorrhea and Doppler Indicies of Uterine Artery (일차성 월경통과 자궁동맥의 혈류역학적 측정값의 관련성에 대한 최신 연구 동향)

  • Kim, Hyo-Jung;Hwang, Deok-Sang;Lee, Jin-Moo;Lee, Chang-Hoon;Jang, Jun-Bock
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.34 no.4
    • /
    • pp.97-110
    • /
    • 2021
  • Objectives: This study was performed to review the research trends in the relationship between primary dysmenorrhea and doppler indicies of uterine artery. Methods: The search for related papers used 'Pubmed', a reserch engine in the America National Library of Medicine and Korean studies Information Service System (KISS). Used searching terms were 'primary dysmenorrhea', 'menstrual pain' in all cases. And among these studies, we searched by using key word 'uterine artery', 'doppler indices', 'doppler parameters', 'pulsatile index', 'resistance index'. Results: Overall 49 studies, 8 studies were finally selected to this study. There were 6 controlled studies and 2 randomised-controlled studies. In all 8 studies, transvaginal ultrasound was used to measure the resistance of uterine blood vessels. All of these studies reported that in patients with primary dysmenorrhea, hemodynamic values of uterine arteries measured by Doppler ultrasound were significantly higher than in normal subjects. Conclusions: According to the results, it was found that there was a positive correlation between the pain level of primary dysmenorrhea and the pulsation index and resistance index of the uterine artery. Based on these results, it can be seen that the doppler indicies of uterine artery have the potential to be used as an evaluation scale for Korean traditional medicine for primary dysmenorrhea.

Delay and Doppler Profiler based Channel Transfer Function Estimation for 2×2 MIMO Receivers in 5G System Targeting a 500km/h Linear Motor Car

  • Suguru Kuniyoshi;Rie Saotome;Shiho Oshiro;Tomohisa Wada
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.9
    • /
    • pp.8-16
    • /
    • 2023
  • In Japan, high-speed ground transportation service using linear motors at speeds of 500 km/h is scheduled to begin in 2027. To accommodate 5G services in trains, a subcarrier spacing frequency of 30 kHz will be used instead of the typical 15 kHz subcarrier spacing to mitigate Doppler effects in such high-speed transport. Furthermore, to increase the cell size of the 5G mobile system, multiple base station antennas will transmit identical downlink (DL) signals to form an expanded cell size along the train rails. In this situation, the forward and backward antenna signals are Doppler-shifted in opposite directions, respectively, so the receiver in the train may suffer from estimating the exact Channel Transfer Function (CTF) for demodulation. In a previously published paper, we proposed a channel estimator based on Delay and Doppler Profiler (DDP) in a 5G SISO (Single Input Single Output) environment and successfully implemented it in a signal processing simulation system. In this paper, we extend it to 2×2 MIMO (Multiple Input Multiple Output) with spatial multiplexing environment and confirm that the delay and DDP based channel estimator is also effective in 2×2 MIMO environment. Its simulation performance is compared with that of a conventional time-domain linear interpolation estimator. The simulation results show that in a 2×2 MIMO environment, the conventional channel estimator can barely achieve QPSK modulation at speeds below 100 km/h and has poor CNR performance versus SISO. The performance degradation of CNR against DDP SISO is only 6dB to 7dB. And even under severe channel conditions such as 500km/h and 8-path inverse Doppler shift environment, the error rate can be reduced by combining the error with LDPC to reduce the error rate and improve the performance in 2×2 MIMO. QPSK modulation scheme in 2×2 MIMO can be used under severe channel conditions such as 500 km/h and 8-path inverse Doppler shift environment.

Performance analysis of joint equalizer and phase-locked loop in underwater acoustic communications (수중 음향통신에서 위상고정루프와 결합된 등화기의 성능분석)

  • Kim, Seunghwan;Kim, In Soo;Do, Dae-Won;Ko, Seokjun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.2
    • /
    • pp.166-173
    • /
    • 2022
  • In this paper, the performance of joint equalizer and phase-locked loop in underwater communications is analyzed. In the channel where the Doppler frequency exists, it is difficult to recover the transmitted data only by the equalizer. To compensate for the Doppler frequency, the phase-locked loop is used. For removing the time-varying multipath and the Doppler frequency simultaneously, the equalizer and the phase-locked loop operate jointly. Also, if the initial Doppler frequency error obtained by Fast Fourier Transform (FFT) is compensated, the convergence speed of the joint equalizer and phase-locked loop can be improved. To verify the performance, lake and sea experiments were conducted. As a result, it was showed that the joint equalizer and phase-locked loop converges sufficiently in the preamble (known data) period regardless of whether the Doppler frequency is compensated or not. And, the bit error in random data period is not occurred. However, we can increase the convergence speed of the equalizer more than twice through the compensation of Doppler frequency.

Range estimation of underwater vehicles using superimposed chirp signals (중첩된 처프 신호를 이용한 수중 이동체의 거리 추정)

  • Hyung-in Ra;Kyung-won Lee;Chang-hyun Youn;Ki-man Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.511-518
    • /
    • 2023
  • Accurate ranging is one of the key factors in the test and evaluation process of underwater vehicles. In particular, when estimating range using Time of Arrival (ToA) values, signals such as Linear Frequency Modulation (LFM), a chirp signal, are highly applicable due to their correlated nature. However, in a Doppler shift environment with mobility, measurement errors may occur due to the range-Doppler coupling effect. In this paper, we propose a signal that compensates for the distance-Doppler coupling effect to reduce the measurement error of the arrival time value. The proposed signal is constructed by superimposing two types of LFM signals, and the range-Doppler coupling effect can be minimized. Through simulations, it is confirmed that the proposed signal is a way to compensate for the distance-Doppler coupling effect in the distance estimation of underwater mobile bodies, reducing the measurement error of the arrival time value.

A Study on the accuracy of speed measuring system by the Doppler effect -The error of speed single beam Doppler log over the ground by various trim- (Doppler 효과(效果)에 의한 속도계측장치(速力計測裝置)의 정도(精度)에 관(關)한 연구(硏究) -Single beam Doppler log의 트림 변화에 따른 대지속력(對地速力) 오차(誤差)-)

  • Kim, Koang-Hong
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.9 no.2
    • /
    • pp.179-187
    • /
    • 1997
  • Doppler log and current meter are based on the measurment of the doppler effect. Ship's speed over the ground measured by means of doppler log effect of underwater ultrasonic intends to get infulence by the difference of sound velocity, the ship's course, the sea bottom inclination, the trim and tranducer installation etc. This paper investigated on the error of speed over the ground by change of the trim comparing the real speed obtained by the mile post with the speed of single beam type doppler log on the trainning ship Kyeongyangho. The results are as follows ; 1. Indicating speed of doppler log is very much greatly influenced on variation of trim, but the real speed is less affected variation by trim. 2. The range of variation and error of speed over ground are smallest when ship's trim is 2.15m trim by the stern.

  • PDF

Changes in pulpal blood flow during orthodontic tooth movement studied by Doppler ultrasound (Doppler ultrasound를 이용한 교정적 치아 이동 시 치수 혈류량의 변화의 측정- 예비실험)

  • Lim, Kyoung-Sub;Bae, Young-Min;Cha, Jung-Yul;Yu, Hyung-Seog;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.39 no.6
    • /
    • pp.372-382
    • /
    • 2009
  • Objective: This study was to change of pulp blood flow among maxillary and mandibular anterior tooth with mild crowding and adjacent teeth using Ultrasound Doppler graphy. Methods: The change of pulp blood flow was measured three times using Ultrasound Doppler graphy; before the attachment of brackets, after 3 week, and after 6 week. The sample consists of 15 year old eighteen patients. Results: Before the attachment of brackets, after 3 weeks, and after 6 weeks, there were no significant differences in the change of pulp blood flow in each part (maxilla and mandible) and each tooth according to period. In addition, to compare internal dangerousness of loss of the pulp vitality, when pulp blood flow is compared in each tooth before orthodontic treatment, there were no statistically significant differences in maxillary lateral incisor and mandibular canine but it showed low values in all measurement items (p > 0.05). Conclusions: Results of this study can be not only methodological preliminary data in further study such as tooth movement type of Ultrasound Doppler graphy and particular study considered the patient age, but also reference materials for the loss of pulp vitality in orthodontic treatment.

Transcranial Doppler Ultrasonography(TCD) in diagnosis of Cerebrovascular Accident (CVA) (뇌졸중의 진단에 대한 TCD의 활용 (Brain CT, Brain MRI와 Transcranial Doppler Ultrasonography 비교를 통한 뇌졸중 진단의 상호 보완에 관한 연구))

  • Park, Se-Gi;Kang, Myeong-Seog;Jun, Chan-Yong;Park, Chong-Hyeong
    • The Journal of Korean Medicine
    • /
    • v.17 no.1 s.31
    • /
    • pp.171-189
    • /
    • 1996
  • Background and Purpose: The greater part of patients to visit Hospital of Oriental Medicine suffer from cerebrovascular accident(CVA). There is transcranial Doppler(TCD) in the diagnostic method to confirm cerebrovascular accident(CVA). Transcranial Doppler(TCD) is an accurate method of monitoring the blood flow velocities of the cerebral vessels and have been generally used to prevent symptomatic vasospasm and confirm cerebral infarction. So we studied, in the crebrovascular accident(CVA), to estimate whether transcranial Doppler(TCD) is useful to. Methods: Using transcranial doppler(Multigon Model 500M Transcranial Doppler System), we measured the mean and peak velocity and the direction of blood flow in 10 cerebrovascular accident(CVA)'s subjects who had been examined by Computed Tomography(CT) or Magnetic Resonance Imaging (MRI). Results : As an anticipation, in cerebrovascular accident(CVA)'s subject with Cb-infarction, the mean and peak velocity of blood flow fell down remarkably and the direction of blood flow was change or irritable. But didn't find out any signal in lacunar infarction. Also, in case with spontaneous hemorrhage, the velocity and direction of blood flow was change but this signal was short of diagnosis for Cb-hemorrhage. Besides, we found signals about embolism, stenosis, thrombosis and occlusion in cerebrovascular accident(CVA)'s subjects. Conclusion: In Cb-infarction, the result of TCD was equal to diagnosis with Computed Tomography(CT) or Magnetic Resonance Imaging (MRI). But about lacunar infarction or spontaneous hemorrhage, signals of TCD couldn't be found out or was insufficient more than Computed Tomography(CT) or Magnetic Resonance Imaging(MRI). In cerebrovascular accident(CVA)'s subject with embolism, stenosis, thrombosis or occlusion, signals of TCD were found out more than Computed Tomography(CT) or Magnetic Resonance Imaging(MRI). Therefore transcranial doppler(TCD) is necessary method which makes a diagnosis of cerebrovascular accident(CVA), with Computed Tomography(CT) or Magnetic Resonance Imaging(MRI).

  • PDF