• Title/Summary/Keyword: DO meter

Search Result 193, Processing Time 0.022 seconds

Photochromic Lens development to use Nano particle (1) - Photochromic Lens' estimation method and application - (Nano 입자를 이용한 Photochromic Lens 개발(1) - Photochromic Lens의 평가방법 및 적용 -)

  • Kim, Yong Geun;Seong, Jeong Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.169-174
    • /
    • 2002
  • Make Photochromic lens Photochromism estimation method, and gouge photochromic lens and investigated UV light source to apply. UV light source irradiation ago and after wavelength dependence of photo-transmittance (T%) of darkening and fading state by do optical equipment which is consisted of spectrophotometer, light source, power meter and detecter. Use relative ratio value of maximum $T%{\times}{\lambda}$ area and saturated state area in light off. Dependences estimation introduced darkening efficiency $(K_d)=(1-C_1/A_1)/t_{on}$ relationship value course fading efficiency$(K_f)=(C_2/A_2)/t_{on}$ value during Photochromism's irradiation time in Photochromic lens. Wavelength dependence of transmittance (T%) has form of $T_m+T_1{\exp}[-(x_0-t)/a]$ in Darkening course fading state. Can receive each estimation parameter value as result that apply Photochromism's estimation parameter Z, $K_d$, $K_f$ in Photochromic lens.

  • PDF

Characterization of the Material Properties of 0.68Pb ($Mg_{1}$3/$Nb_{2}$3/)$O_3$-0.32PbT$iO_3$ Single Crystals Grown by the Solid-State-Crystal-Growth Method (고상단결정법으로 성장시킨 0.68Pb ($Mg_{1}$3/$Nb_{2}$3/)$O_3$-0.32PbT$iO_3$ 압전단결정의 물성평가)

  • 이상한;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.103-108
    • /
    • 2004
  • In this paper, all the materials constants of the PMN-32%PT single crystals grown by the solid state crystal growth method were measured by the resonance method. PMN-PT crystals of tetragonal symmetry have six elastic constants, three piezoelectric constants and two dielectric constants for their independent material constants. These materials constants were extracted from six sets of crystal samples of each different geometry to have different vibration modes respectively. Measured results showed that the crystal has larger electromechanical coupling factor k/sub 33/ (∼86%) and piezoelectric constant d/sub 33/ (∼1200pC/N) than conventional piezoceramics. Validity of the measurement was confirmed through comparison of the results with the impedance spectrum from finite element analysis of the samples and the results measured with a commercial do meter.

A Simple Method for Measuring the Immobilization Solids of Coating Colors Using an AA-CWR Water Retention Meter

  • Park, Chang-hak;Lee, Do-Ik;Margaret K. Joyce
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.34 no.5
    • /
    • pp.39-48
    • /
    • 2002
  • The water retention of coating colors can be accurately measured by devices such as an AA-GWR water retention meter whose principle of measurement Is based on pressure filtration of coatings under an externally applied air pressure over a certain period of time. It was hypothesized that such devices could be also used to determine the immobilization solids (IMS) of coating colors by determining a sudden drop in the rate of dewatering, that is, a sudden change in the drainage curves. To test this hypothesis, the immobilization solids of coating colors containing various thickeners and water retention additives at different levels were first accurately measured by a modified immobilization tester based on the well-known gloss drop method, and then their values were compared with those obtained by an AA-GWR water retention tester. They agreed very well and showed that the standard deviation is only 0.14% in the IMS points between both methods. This good agreement was not surprising because both test methods are based on the same end-point, that is, the immobilization solids point at which menisci begin to form at the coating surface. Theoretical considerations supporting this new method for measuring the immobilization solids of coating colors are presented and some recommendations for the test method are discussed. Also, the effect of various thickeners and water retention additives on the properties and printability of coated papers is discussed.

Evaluating the impacts of using piles and geosynthetics in reducing the settlement of fine-grained soils under static load

  • Shariati, Mahdi;Azar, Sadaf Mahmoudi;Arjomand, Mohammad-Ali;Tehrani, Hesam Salmani;Daei, Mojtaba;Safa, Maryam
    • Geomechanics and Engineering
    • /
    • v.20 no.2
    • /
    • pp.87-101
    • /
    • 2020
  • The construction of combined pile-raft foundations is considered as the main option in designing foundations in high-rise buildings, especially in soils close to the ground surface which do not have sufficient bearing capacity to withstand building loads. This paper deals with the geotechnical report of the Northern Fereshteh area of Tabriz, Iran, and compares the characteristics of the single pile foundation with the two foundations of pile group and geogrid. Besides, we investigate the effects of five principal parameters including pile diameter and length, the number of geogrid layers, the depth of groundwater level, and pore water pressure on vertical consolidation settlement and pore water pressure changes over a year. This study assessed the mechanism of the failure of the soil under the foundation using numerical analysis as well. Numerical analysis was performed using the two-dimensional finite element PLAXIS software. The results of fifty-four models indicate that the diameter of the pile tip, either as a pile group or as a single pile, did not have a significant effect on the reduction of the consolidation settlement in the soil in the Northern Fereshteh Street region. The optimum length for the pile in the Northern Fereshteh area is 12 meters, which is economically feasible. In addition, the construction of four-layered ten-meter-long geogrids at intervals of 1 meter beneath the deep foundation had a significant preventive impact on the consolidation settlement in clayey soils.

STUDY ON COLOR DIFFERENCE BETWEEN NATURAL TEETH AND COMPOSITE RESINS (자연치와 복합레진의 색분포에 관한 연구)

  • 김희선;이인복;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.2
    • /
    • pp.180-187
    • /
    • 2001
  • The structure of current guides is largely illogical and without any rational use of color ordering. The shade guides are generally made of plastic (rather than the actual composite material) and do not accurately depict the true shade. translucency. or opacity of the composite resin after polymerization. To solve this problem, information based on evaluations of natural teeth and material that use the same method and experimental conditions is necessary. The present investigation measured the color of natural maxillary anterior teeth in vivo and compared the results with those of composite resins. 269 Korean subjects were selected for this study. Intact central incisor. lateral incisor. and canine were selected. The clinical crowns were free of caries or restorations. The middle site of the coronal portion on the labial surface of the tooth was measured by Chroma Meter. The five light activated. resin-based materials (Amelogen, Denfil, Elitefil, Spectrum, Z100) were used in this study. Resin composite was condensed into plastic mold with a diameter of 8mm and a thickness of 4mm. pressed between glass plates to flatten the surfaces. and polymerized using a Visilux II visible light activation unit. The surfaces were polished sequentially on wet sandpaper. Color measurements of each specimen were accomplished by Chroma Meter. A computer program that compares each tooth color with each composite resin color was written and the minimum CIELAB color difference ($\Delta$E$^*$) between tooth and each material was calculated. Under the conditions of this study: 1. Teeth tend to become darker with advancing age. 2. Canines were darker. more yellow. and less green than incisors. 3. The teeth from the women were lighter. more green. and less yellow than the male teeth. 4. In general. composite resins were lighter. more green. and less yellow than teeth. Deficiencies were noted in Hues in YR range. 5. Mean color differences between the five composite resin products and teeth were detectable to the naked eye($\Delta$E$^*$>1.0). 6. In comparing the mean $\Delta$E$^*$ values of materials. Spectrum showed the least followed by Z100, Elitefil, Amelogen, Denfil in increasing order.

  • PDF

A Study on Minimum Separation Distance for Aboveground High-pressure Natural Gas Pipelines (지상 고압 천연가스 배관의 최소 이격거리 기준에 관한 연구)

  • Lee, Jin-Han;Jo, Young-Do
    • Korean Chemical Engineering Research
    • /
    • v.57 no.2
    • /
    • pp.225-231
    • /
    • 2019
  • In Korea, the minimum separation distance between aboveground high-pressure natural gas pipeline and buildings is regulated by Korea gas safety (KGS) code. In this paper, The technical backgrounds for the revision of the KGS code related to the minimum separation distance was presented. A consequence-based approach was adopted to determine the minimum separation distance by a reasonable accident scenario, which was a jet fire caused by the rupture of one inch branch line attached the gas pipeline. Where, the higher thermal radiation flux threshold was selected for workers in industrial area than for people in non-industrial area, because the workers in industrial area were able to escape in a shorter time than the people in public. As result of consequence analysis for the accident scenario, we suggested the KGS code revision that the minimum separation distances between high-pressure natural gas pipeline installed above ground and buildings should be 30 meter in non-industrial area and 15 meter in industrial area. The revised code was accepted by the committee of the KGS code and now in effect.

Highly Integrated DNA Chip Microarrays by Hydrophobic Interaction

  • Park, Yong-Sung;Kim, Do-Kyin;Kwon, Young-Soo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.11C no.2
    • /
    • pp.23-27
    • /
    • 2001
  • Microarray-based DNA chips provide an architecture for multi-analyte sensing. In this paper, we report a new approach for DNA chip microarray fabrication. Multifunctional DNA chip microarrays were made by immobilizing many kinds if DNAs on transducers (particles). DNA chip microarrays were prepared by randomly distributing a mixture of the particles on a chip pattern containing thousands of micro meter-scale sites. The particles occupied different sites from array to array. Each particle cam be distinguished by a tag that is established on the particle. The particles were arranged on the chip pattern by the random fluidic self-assembly (RFSA) method, using hydrophobic interaction.

A Study on the Investigation of Performance for Evaluation Method of Unit Water Content of Fresh Concrete (굳지 않은 콘크리트 단위수량 추정기법의 성능 검토에 관한 연구)

  • Kim, Yong-Ro;Choi, Il-Ho;Jung, Yang-Hee;Kim, Hyo-Rak;Lee, Do-Bum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.367-370
    • /
    • 2005
  • In this study, air meter method and capacitance measurement method to apply economically at quality control of ready-mixed concrete among various unit water content measurement technique was selected. Then, it was evaluated estimating performance of unit water content according to the change of water-binder ratio and unit water content. Also, it was examined influence about error occurrence of unit water content by change of properties of used materials. Finally, based on this study, it was proposed fundamental data to utilize measurement technique of unit water content to quality control. of ready-mixed concrete in construction field.

  • PDF

KMAG payload instrument of Korea Pathfinder Lunar Orbiter

  • Jin, Ho;Kim, Khan-Hyuck;Son, Derac;Lee, Seongwhan;Lee, Hyojeong;Lee, Jung-Kyu;Lee, Mangyu;Lee, Seungah;Shin, Jehyuck;Garrick-Bethell, Ian
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.89.2-89.2
    • /
    • 2017
  • Korea Pathfinder Lunar Orbiter (KPLO) is a first Korean Lunar exploration mission. KPLO is equipped with four payloads in Korea and one payload in United States. KMAG is one of Korean payloads to measure the Moon's magnetic field. Moon has a no dipole magnetic field such as earth's global magnetic field. But there are many curious crustal magnetic anomalies. these features still do not well understood. This is a main scientific objective of KMAG payload and the study of space environment around moon is a second objective. KMAG has three magnetometers which are mounted in the edge of the 1.2 meter boom. This paper shows a KMAG's requirements, instrument description, and a preliminary function test results.

  • PDF

Acomparison of Sao2 & PACO2 Changes of pre & post vocal training Classical singer (발성훈련 전 후의 혈중산소포화도(SaO2)와 폐포 내 이산화탄소분압(PaCO2)의 비교 연구)

  • Nam, Do-Hyun;Ahn, Chul-Min
    • Proceedings of the KSPS conference
    • /
    • 2007.05a
    • /
    • pp.261-264
    • /
    • 2007
  • Five males trained singers (age:25.0${\pm}$1.4years, career:6.8${\pm}$1.1 years) and five female trained singers (age:22.0${\pm}$1.0years, career:5.8${\pm}$1.2 years) participated in this study. SaO2(Oxi Hemoglobin saturation) measured by Oxy-Pulse meter and PAC02 (Pressure Alveolar Co2) measured by Quick et CO2 are compared with pre and post vocal training. As the result, PAC02 was lower than normal range (36-40mmHg) after vocal training, leading to Hypocapnia. This causes headache and dizziness

  • PDF