• 제목/요약/키워드: DO meter

검색결과 193건 처리시간 0.024초

DO 미터를 이용한 탐구중심 물 환경교육 프로그램 개발 - 용존산소 측정 활동 - (Development of Inquiry-based Water Environmental Education Program using DO Meter - Measuring Activity of Dissolved Oxygen -)

  • 류재홍;이두곤
    • 한국환경교육학회지:환경교육
    • /
    • 제19권2호
    • /
    • pp.96-107
    • /
    • 2006
  • Inquiry has great value in environmental education(EE). Being able to see the world environmentally through 'inquiry-based environmental education' can be an important value and goal of EE. In this study, we intended to develop an EE program of measuring activity of dissolved oxygen(DO), based on the theory of 'inquiry-based EE'. Especially, we recognized the potential that DO meter can be used in 'inquiry-based EE', and we tried to develop a model of inquiry-based EE using DO meter. As a result of this research, we present specific models of inquiry-based EE about how to perform measuring activity of DO and how to use the DO meter in laboratories and streams from the perspective of inquiry of water environment. In the process of program development, we considered organization of the inquiry process, use of concept and knowledge, scientific inquiry and insightful inquiry, integration, sustain-ability, content components of 'Environmental Studies for EE', developmental level and in-forest of students. The developed EE model is a scientific inquiry model, pursuing 'explanation' based on data collection. Through this model, we tried to make students see water environment more deeply. The developed program can be applied to various water environments, like laboratories, streams, ponds, etc. It can be more effective inquiry activity if we perform measuring activities simultaneously with PH, electrical conductivity, and turbidity meters.

  • PDF

승용차 Combination Meter의 가독성 향상을 위한 색상 설계 (Color Design of Combination Meter in Passenger Car for Improving Readability)

  • 기도형
    • 산업공학
    • /
    • 제11권2호
    • /
    • pp.139-147
    • /
    • 1998
  • The purpose of this study is to survey colors of background, marker, and pointer being used in passenger car's combination meter, and to suggest ergonomic design guidelines of combination meter to enhance driver's readability. An experiment was conducted, in which colors of background, marker, and pointer were selected as independent variables, and reading time, reading error, and preference for combination meter were measured as dependent variables. Most of passenger cars sold in Korea were found to have combination meter with black background, while marker. The experimental results showed that reading time of combination meter with white background, black marker and point was shortest, reading error was lowest in combination meter with black background, yellow marker pointer, and preference for combination meter with white background, black marker and black or red pointer was highest. The results implied that combination meter with white background, black marker and black pointer should be used for comprehensively optimizing reading time, reading error, and preference for it. It was expected that these results could be used as valuable design guidelines when designing combination meter of passenger car.

  • PDF

휴대용 용존산소 측정 시스템의 설계 및 제작 (Design and Fabrication of Portable Dissolved Oxygen Measurement System)

  • 장중원;이성필
    • 융합신호처리학회논문지
    • /
    • 제9권3호
    • /
    • pp.219-223
    • /
    • 2008
  • 스크린 프린트법으로 저가형 후막 용존산소 센서를 제작하고, 휴대용 용존산소 측정 시스템을 구현하였다. 전류 특성은 인가전압(바이어스 전압)을 0.7 V로 하였을 때, 응답시간도 짧고 전류 값의 변화도 가장 크다는 것을 알 수 있었다. 시스템의 구현은 MCU, 증폭단, 필터단, 전원부 및 디스플레이로 구성하였다. 용존산소 농도는 아날로그 값을 디지털로 변환하여 백분율로 표현되도록 프로그램하였다. 제작된 용존산소 측정 시스템은 표준 용액 대비 오차 ${\pm}0.5%$의 정확도 및 약 100초의 응답시간을 나타내어 고가의 상용 용존산소 센서를 대치할 수 있을 것으로 기대된다.

  • PDF

릴리프밸브 쿠션기구 내장형 공기압 실린더의 구동 특성 (Driving Characteristics of Pneumatic Cylinder with Relief Valve Cushion Devices)

  • 김도태
    • 드라이브 ㆍ 컨트롤
    • /
    • 제13권4호
    • /
    • pp.7-13
    • /
    • 2016
  • This paper presents the meter-out and meter-in speed control characteristics of a pneumatic cylinder with relief valve type cushion device. The piston displacement and velocity are measured to investigate high speed driving performance with variation of the pressure setting in relief valve, air supply pressure, load mass, the supply and exhaust flow rate from the cylinder. Also, the internal pressures and temperatures driving pressure and cushion chamber are measured. The piston displacements and velocities of meter-out and meter-in control are compared experimentally determined data. A comparison experimental data meter-out and meter-in control show that a relief valve type cushion device is suitable for high speed pneumatic cylinders. The desired response characteristics of piston displacement and velocity are satisfactory adjust the pressure setting of a relief valve with varying system parameters such as air supply pressure, load mass and controlled flow rate.

공기압 쿠션 실린더의 미터아웃/미터인 속도제어 특성에 관한 연구 (A Study on the Meter-Out and Meter-In Speed Control Characteristics in Pneumatic Cushion Cylinders)

  • 김도태
    • 한국생산제조학회지
    • /
    • 제22권1호
    • /
    • pp.1-7
    • /
    • 2013
  • Pneumatic cylinders are widely used to actuators in automatic equipments because they are relatively inexpensive, simple to install and maintain, offer robust design and operation, are available in a wide range of standard sizes and design alternatives. This paper presents a comparative study among the dynamic characteristics of meter-out and meter-in speed control of pneumatic cushion cylinders with a relief valve type cushion mechanism. Because of the nonlinear differential equations and a requirement for simultaneous iterative solution in a mathematical model of a double acting pneumatic cushion cylinder, a computer simulation is carried out to investigate pressure, temperature, mass flow rate in cushion chamber and displacement and velocity time histories of piston under various operating conditions. It is found that the piston velocity and pressure response in meter-in speed control are more oscillatory than with meter-out those when pneumatic cushion cylinders are driven at a high-speed. In meter-out speed control, the effective area of the flow control valve is larger than that of meter-in, and the supply pressure has to be much higher than the pressure required to move the load because it has also to overcome the back pressure in cushion chamber.

FTA를 이용한 수변전설비의 최소절단집합 도출 (Minimal Cut Set of Electric Power Installations using Fault Tree Analysis)

  • 박영호;김두현;김성철
    • 한국안전학회지
    • /
    • 제32권1호
    • /
    • pp.41-46
    • /
    • 2017
  • In this paper, from making an electrical fire which is thought to be the most damaging among potential dangers as a top event, minimal cut sets (MCS) about it were analyzed. For this, components of a power substation were classified into 15 items. Failure rates and modes were extracted based on Korea Electrical Safety Corporation, IEEE Gold Book, and RAC. To analyze the top event (an electrical fire), main events were assorted into "safety devices for overcurrent" and "ampere meter of detecter". Failure of components was divided into failure of VCB, COS, and MCCB. A fault tree was composed of 3 AND gate, 5 OR gates and 17 basic events. Overlapped events among the basic events are things which occur from relevant components. They were attached to the tree by distinguishing identifiers. In case of FT, two minimal cut sets of "IO_METER", "MF_METER", "DO_MCCB" and "IO_METER", "MF_METER", "DO_VCB" take 46% of electrical fires. Therefore, about basic events which are included in the top two minimum cut sets, strict control is necessary.

A study on the dynamics of a turbine-meter-type flowmeter for hydraulic systems

  • Yokota, Shinichi;Kim, Do-Tae;Suzuki, Kenji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.60-65
    • /
    • 1994
  • In this study, the dynamic characteristics of a turbine-meter-type flowmeter is investigated by making use of the remote instantaneous flow rate measurement method (RIFM). The results of the frequency response test indicated that the gain of the flow rate of the turbine-meter-type flowmeter relative to the flow rate of the RIFM was nearly unity up to 40Hz and the phase lag of the flow rate became 90 degrees at 70Hz.

  • PDF

pH meter

  • 오도석
    • 월간산업보건
    • /
    • 통권85호
    • /
    • pp.25-31
    • /
    • 1995
  • PDF

생체신호 측정기와 스마트 디바이스를 활용한 심전도 데이터 기반의 원격진료 시스템 (The Telemedicine System based ECG Data using Bio-Signal Meter and Smart Device)

  • 김이슬;조진수
    • 반도체디스플레이기술학회지
    • /
    • 제11권3호
    • /
    • pp.51-56
    • /
    • 2012
  • In this paper, we propose a telemedicine system based ECG data using a bio-signal meter and a smart device for treating faraway patients. This system is composed of a patch-shaped portable bio-signal meter, patient's smart device application, and doctor's PC software. Using these components, doctors and patients can do telemedicine. First, a patient measures his own ECG signal with a bio-signal meter and send the data to a doctor using a smart device application. Then, the doctor checks the ECG data, and make and send a diagnosis chart to web server. Likewise, doctors and patients can be offered a medical environment without time and space restraints. Applying this system to real medical system can improve the problem of low accessibility and efficiency and also can reduce medical expenses.