• 제목/요약/키워드: DLP

검색결과 222건 처리시간 0.024초

DLP 프로젝션 TV의 화소 증진 엑추에이터 개발 (Development of Improved Pixel Enhancement Actuator for DLP Projection TV)

  • 윤기탁;김재은;이경택;홍삼열;고의석;한상훈;구희술
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.463-466
    • /
    • 2005
  • While recent display devices are becoming light and slim, the size of a screen is especially the important issue in the field of display devices. Furthermore, it is also required that the projection TV, a large screen display device, be able to represent higher resolutions as the digital broadcasting is set off. In order to realize high resolutions in a DLP projection TV, the number of pixel on DMD should be increased. However, a large number of pixels make it difficult to realize resulting small sized pixels and this cause the increase in cost. Therefore, we propose a simple and improved pixel enhancement actuator using the existing DMD by offsetting half pixels repeatedly in the vertical direction.

  • PDF

흉부 및 복부에서 AEC 적용에 따른 MDCT의 선량 감소 효과 (Radiation Dose Reducing Effect during the AEC System in the Chest and Abdomen of the MDCT Scanning)

  • 이종석;권대철;유병규
    • 한국콘텐츠학회논문지
    • /
    • 제9권3호
    • /
    • pp.225-231
    • /
    • 2009
  • CT검사에 따른 방사선 선량의 유해성에 대한 관심이 고조되고 있어, 고정관전류기법과 AEC(automatic exposure control)를 적용하여 선량의 감소 효과를 비교하였다. 64MDCT를 이용하여 인체조직등가물질 팬텀으로 흉부 및 복부 부위를 고정관전류기법과 AEC를 적용하여 CTDIvol과 DLP를 비교하였고, 영상의 평가는 관심영역으로 CT감약계수와 노이즈를 측정하여 비교하였다. 흉부에서 고정관전류기법과 AEC적용에 따른 선량감소 효과는 CTDIvol 35.2%, DLP 49.3%, 복부에서는 CTDIvol 5.9%, DLP 3.2% 감소 효과가 있었다. CT검사에서 자동노출장치인 AEC를 이용하여 선량의 감소효과가 있다. CT 검사에 따른 환자의 피폭선량을 줄이기 위해서는 AEC를 이용하여야 한다.

디지털도서관의 경제성 평가 : 국립디지털도서관 DLP 사례 연구 (Economic Efficiency of Digital Library : A Case Study on the DLP of the National Digital Library)

  • 김동석;조동호;고영만
    • 정보관리학회지
    • /
    • 제20권4호통권50호
    • /
    • pp.159-193
    • /
    • 2003
  • 본 연구는 국립중앙도서관의 국립디지털도서관 건립사업 중 서고 건축 부분을 제외한 디지털도서관프로그램을 대상으로 경제적 타당성을 분석한 사례연구이다. 평가 결과의 정량화를 위하여 비용편익 분석 방법을 사용하였으며, 추정치의 오차를 보완하고 분석 결과의 신뢰도를 높이기 위하여 결과 값에 대한 민감도 분석을 실시하였다. 연구 결과 편익/비용 비율이 1.70으로 분석되어 경제성이 매우 양호한 것으로 나타났다. 본 연구는 도서관이 사회전반에 걸쳐 장기적으로 파급하는 효과를 실증적으로 분석한 것으로 실용적인 기능을 할 수 있을 것이며, 또한 본 연구에서 적용한 비용편익 분석 모형은 앞으로 이루어질 보다 전문적이고 깊이 있는 연구의 기초로 적용될 수 있을 것이다.

MDCT 관상동맥 조영 검사에서 전향적 동조화 및 후향적 동조화 기법의 화질과 선량 관계 (An Estimate of Image Quality and Radiation Doses of Coronary Artery in MDCT Using Prospective and Retrospective ECG Gating Scan Mode)

  • 오종갑
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권4호
    • /
    • pp.315-321
    • /
    • 2011
  • 본 연구는 검사 기법에 따른 영상의 질과 방사선 피폭의 정도를 제시하여 검사자가 받는 방사선 피폭을 저감시키는 데 목적이 있다. 관상동맥 전산화 단층 혈관조영(Coronary CTA, coronary computed tomography angiography) 검사자를 대상으로 SnapShot Pulse의 전향적 동조화 기법과 SnapShot Segment의 후향적 동조화 기법으로 coronary CTA 검사에서 검사자가 받는 단면 피폭선량(CTDIvol, volume computed tomography dose index), 총 피폭선량(dose-length product; DLP)을 각각 측정하였다. 또한, Coronary CTA 촬영조건을 동일하게 팬텀을 이용하여 CT감약계수, 노이즈 및 균일도, 공간분해능을 측정하였다. 연구 결과 두기법에서 CT감약계수, 노이즈 및 균일도, 공간분해능의 질적 수준이 비슷하게 나타났으며, CTDIvol, DLP는 SnapShot Segment의 후향적 동조화 기법에 비해 피폭선량이 약 37.5%, 40.3% 감소되었다. 임상에서 coronary CTA 검사 시 SnapShot Pulse의 전향적 동조화 기법을 적극 채택하여 검사자가 받는 방사선 피폭을 감소시키기 위한 노력이 절실히 요구된다.

디지털 광학기술인 3D 프린터로 제작된 임시수복용 레진의 두께별 색 평가 (Color evaluation by thickness of interim restorative resin produced by digital light processing 3D printer)

  • 강월;김원기
    • 대한치과기공학회지
    • /
    • 제43권3호
    • /
    • pp.77-83
    • /
    • 2021
  • Purpose: The purpose of this in vitro study was to measure and compare the thickness-dependent color dimensions of digital light processing (DLP) three-dimensional (3D) printer and conventional interim restorative resin. Methods: Specimens (N=60) were fabricated using either subtractive manufacturing (S group) or DLP 3D printing (D group) material. All milled and 3D-printed specimens were allocated into three different groups (n=10) according to different thicknesses as follows: 1.0, 1.5, and 2.0 mm. Color measurements in the CIELab coordinates were made using a spectrophotometer under room light conditions (1,003 lux). The color differences (𝚫E*) between the specimen and control target data were calculated. Data were analyzed using the oneway analysis of variance (ANOVA). Post hoc comparisons were conducted using Tukey's honestly significant difference method (α=0.05 for all tests). Results: The 𝚫L*, 𝚫a*, 𝚫b*, and 𝚫E* values of interim restorative resin produced by DLP 3D printing were obtained in terms of the specimen's thickness increased compared with the increases by subtractive manufacturing. When the thickness was similar, the color difference between subtractive manufacturing and DLP 3D printing was ≥5.5, which is a value required by the dentist for remanufacturing. Conclusion: Color was influenced by the thickness of the interim restorative resin produced by DLP 3D printing.

광개시제 함량과 노광 시간이 DLP기반 알루미나 3D 프린팅 공정에 미치는 영향 (Effect of Photo Initiator Content and Light Exposure Time on the Fabrication of Al2O3 Ceramic by DLP-3D Printing Method)

  • 김경민;정현덕;한윤수;백수현;김영도;류성수
    • 한국분말재료학회지
    • /
    • 제26권4호
    • /
    • pp.327-333
    • /
    • 2019
  • In this study, a process is developed for 3D printing with alumina ($Al_2O_3$). First, a photocurable slurry made from nanoparticle $Al_2O_3$ powder is mixed with hexanediol diacrylate binder and phenylbis(2,4,6-trimethylbenzoyl) phosphine oxide photoinitiator. The optimum solid content of $Al_2O_3$ is determined by measuring the rheological properties of the slurry. Then, green bodies of $Al_2O_3$ with different photoinitiator contents and UV exposure times are fabricated with a digital light processing (DLP) 3D printer. The dimensional accuracy of the printed $Al_2O_3$ green bodies and the number of defects are evaluated by carefully measuring the samples and imaging them with a scanning electron microscope. The optimum photoinitiator content and exposure time are 0.5 wt% and 0.8 s, respectively. These results show that $Al_2O_3$ products of various sizes and shapes can be fabricated by DLP 3D printing.

3.5 GHz 대역에서 동작하는 DLP 배열 안테나의 설계 및 제작 (Design and Fabrication of DLP Array Antenna for 3.5 GHz Band)

  • 윤중한
    • 한국전자통신학회논문지
    • /
    • 제16권6호
    • /
    • pp.1037-1044
    • /
    • 2021
  • 본 논문에서는 3.5 GHz 대역에 적용 가능한 DLP(Dual Linear Polarization) 배열 안테나를 제안하였다. 제안된 안테나는 1×4 배열 안테나로 구성되어 있으며 두 개의 입력포트를 갖도록 설계하였다. 또한 임피던스매칭을 위해 십자가 구조가 패치 아래 부분과 연결하였다. 각 안테나는 18.85 mm(W1)×18.85 mm(L1)의 크기를 갖으며 1×4 배열 안테나 전체 구조는 236.0 mm(W)×60.2 mm(L)의 크기를 갖으며 두께(h) 1.6 mm, 그리고 비유전율이 4.3인 FR-4 기판 위에 설계하였다. 제작 및 측정결과로부터, -10 dB 반사손실을 기준으로 입력포트 1에서 70 MHz (3.54~3.61 GHz), 입력포트 2에서 75 MHz (3.55~3.625 GHz)의 대역폭을 얻었으며 전달계수 S21은 -20dB 이하의 값을 얻었다. 또한 두 입력단자 사이의 교차편파의 값을 얻었다.

광중합형 프린터로 제작한 임시 의치용 인공치아의 UV형 초음파 세척에 따른 선형측정 평가 (Linear measurement evaluation according to UV-type ultrasonic cleaning of artificial teeth for temporary dentures manufactured using a light-curing type printer produced by a DLP printer)

  • 김동연;이광영
    • 대한치과기공학회지
    • /
    • 제46권1호
    • /
    • pp.8-14
    • /
    • 2024
  • Purpose: This study compares the deformation of traditional resin dentures to resin dentures printed with digital light processing (DLP). Methods: Eleven edentulous research models were developed. Ten of them were made with traditional resin dentures. The remaining one was prepared for scanning and 3D (three-dimensional) printing. Ten traditional resin dentures were made, with the remaining artificial teeth created using 3D software and a DLP printer. Traditional resin dentures, 3D printed resin denture artificial teeth, and a denture base with artificial teeth were all cleaned simultaneously in an ultrasonic cleaner for 3 minutes. Three groups were assigned four artificial tooth measurement points, which were then measured with digital calipers. The measured data was analyzed using descriptive statistics. The significance test was conducted using a nonparametric test Kruskal-Wallis test due to the small number of specimens (α=0.05). Results: The traditional resin dentures had the lowest strain rate at -0.04%, while the group that manufactured only artificial teeth had the highest strain rate at -0.09%. However, no statistically significant difference was observed between the 3 groups (p>0.05). Conclusion: During ultraviolet-type ultrasonic cleaning, traditional resin dentures (TD group) and denture base with artificial teeth made of DLP (DD group) demonstrated stable durability, whereas the artificial teeth made of DLP (AD group) with only artificial teeth did not show a good deformation rate.

wwMD 프로젝션 TV의 명암비 향상 액츄에이터 개발 (Development of a Contrast Enhancer for MD Projection TV)

  • 김재은;윤기탁;이종진;홍삼열;고의석;주채민;양상식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.656-659
    • /
    • 2006
  • MD (DLP, LCoS) Projection TV is appropriate for large screen display with high definition at a relatively low price and thus, has been popular in the digital TV market. In order to realize high resolutions in the DLP projection TV, we successfully developed the Pixel Enhancement Actuator. Furthermore, it is also required that the contrast ratio of projected video signals onto a large screen should be improved. Therefore, we propose a contrast enhancer which adjusts the amount of projected lights by a dynamic aperture and a attached position sensor.

  • PDF