• Title/Summary/Keyword: DLP

Search Result 225, Processing Time 0.027 seconds

The Study on the Non-Uniformity of PECVD SiO2 Deposition by the Plasma Diagnostics (플라즈마 진단에 의한 PECVD SiO2 증착의 불균일성 원인 연구)

  • Ham, Yong-Hyun;Kwon, Kwang-Ho;Lee, Hyun-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.2
    • /
    • pp.89-94
    • /
    • 2011
  • The cause of the thickness non-uniformity in the large area deposition of $SiO_2$ films by PECVD(Plasma Enhanced Chemical Vapor Deposition) was investigated by the plasma diagnostics. The spatial distribution of the plasma species in the chamber was obtained with DLP(Double Langmuir Probe) and the new-designed probe-type QMS(Quadrupole Mass Spectrometer). From the relationship between the spatial distribution of the plasma species and the depositing rate of the $SiO_2$ films, it was conformed that the non-uniform deposition of $SiO_2$ films was related with the spatial distribution of the oxygen radical density and electron temperature.

Study on the Performance of the Grooves for Fluid Dynamic Bearings (유체동압베어링의 그르브 성능에 관한 연구)

  • Kim, Yeung-Cheol;Seong, Se-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.2
    • /
    • pp.91-93
    • /
    • 2011
  • This paper is presented for the performance of the Fluid Dynamic Bearing(FDB) by the groove design and the tooling condition. Recently, spindle motors which require smaller size, lower sound noise, lower vibration, and higher speed of the rotation have been placed in high value-added products including Digital Lightening Processors(DLP), Hard Disk Drives(HDD), and ODDs. The spindle motors using the sintered porous metal bearing have higher vibration and acoustic noise by dry contact and large tolerance of the bearing parts. The Fluid Dynamic Bearing (FDB) with grooves is appropriate for spindle motors adequate in regards to mechanical vibration and acoustic noise. The paper shows the performance comparisons of between sintered porous metal bearing and FDB, and each FDBs according to the tooling deviations of grooves by the Finite Element Analysis(FEA) of the mechanical field. This paper shows the methods to make the grooves, the groove's depth, and the prototype of the motor with the fluid dynamic bearing. The performance characteristics of the grooves with the FDB are verified by the experimental results.

Ultra Grain Refinement and High Strengthening of Deoxidized Low-Phosphorous Copper by Accumulative Roll-Bonding Process (ARB법에 의한 인탈산동의 결정립초미세화 및 고강도화)

  • Lee, Seong-Hee;Han, Seung-Zeon;Lim, Cha-Yong
    • Korean Journal of Materials Research
    • /
    • v.16 no.9
    • /
    • pp.592-597
    • /
    • 2006
  • A deoxidized low-phosphorous (DLP) copper was processed by accumulative roll-bonding (ARB) for ultra grain refinement and high strengthening. Two copper sheets 1 mm thick, 30 mm wide and 300 mm long are first degreased and wire-brushed for sound bonding. The sheets are then stacked to each other, and roll-bonded by about 50% reduction rolling without lubrication at ambient temperature. The bonded sheet is then cut to the two pieces of same dimensions and the same procedure was repeated to the sheets up to eight cycles (${\varepsilon}{\sim}6.3$). TEM observation revealed that ultrafine grains were developed after the 4th cycle, and their size decreased at higher cycles. Tensile strength of the copper increased with the equivalent strain, and it reached 547 MPa which was 3 times higher than that of the initial material. It is concluded that the ARB process is an effective method for high strengthening of the DLP copper.

A Study on the Multi-Tactical Data Link Data Management (다중 전술 데이터링크 데이터 관리에 대한 연구)

  • Hwang, Jung-Eun;Lee, Kang;Jung, Suk-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.3
    • /
    • pp.457-464
    • /
    • 2020
  • ROK Forces operate Link-11, Link-16 and Korean Tactical Data Link System with Link-K(JTDLS: Joint Tactical Data Link System). As the change from Link-11 to Link-22 approaches, in the JTDLS Completed Business will be added tactical data link processing such as Link-22. In this paper, we propose the data management structure for data from multiple tactical data links. Also, we simulate to find ways to process a lot of data quickly using Shared Memory, In-Memory DB, Self Development DB in DLP, and then we confirm the result.

A Study on the Surface Modification Mechanism of Copper Foil Using O2 / Ar Plasma (O2 / Ar 플라즈마를 이용한 구리호일 표면 개질에 관한 연구)

  • Lee, Jongchan;Son, Jinyoung;Kim, Moonkeun;Kwon, Kwang-Ho;Lee, Hyunwoo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.11
    • /
    • pp.836-840
    • /
    • 2013
  • In this study, the surface modification of copper foil using an inductively coupled $O_2$ / Ar plasma as $O_2$ gas fraction (0~100%) was investigated in order to improve the surface characteristics. After plasma treatment, the measurement of the surface roughness, surface contact angle and surface energy were performed for the surface analysis of copper foil. As a result, the surface roughness and the surface energy were increased. And plasma diagnostics was performed by a double Langmuir probe (DLP) and optical emission spectroscopy (OES). Using these results, the plasma surface modification mechanism was investigated.

A study on the efficient 1-pass password-based key exchange protocol (효율적인 1-pass 패스워드 기반 키 분배 프로토콜에 관한 연구)

  • Ahn, Sang-Man;Oh, Soo-Hyun;Won, Dong-Ho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.11b
    • /
    • pp.1119-1122
    • /
    • 2002
  • 본 논문에서는 Ford와 Kaliski[6]가 제안한 패스워드 은닉 기술을 적용하여 클라이언트와 서버의 은닉 변수로 은닉된 값을 서버가 패스워드 검증자로 사용하는 새로운 패스워드 기반 키 교환 프로토콜을 제안한다. 제안하는 프로토콜은 패스워드 검증자를 비밀리에 보관하여야하는 다른 검증자 기반 방식과 달리 클라이언트와 서버의 은닉 변수가 적용된 검증자를 사용하여 서버의 패스워드 검증자에 대한 안전성을 증가시켰다. 또한 Nyberg-Ruppel 방식[4]을 적용하여, 한번의 통신으로 사용자 인증과 키 교환을 할 수 있다. 본 논문에서 제안하는 프로토콜 안전성은 이산대수문제인 DLP(Discrete logarithm Problem)와 DHP(Diffie-Hellman Problem)[6]에 의존한다. 따라서 DLP와 DHP의 가정하에, 제안된 프로토콜은 오프라인 사진공격(off-line dictionary attack), 서버 데이터 도청(server data eavesdropping), 전향적 안전성(forward secrecy), Denning-Sacco 공격[1]에 대하여 안전하다.

  • PDF

Light-weight System Design & Implementation for Wireless Intrusion Detection System (무선랜 침입탐지를 위한 경량 시스템 설계 및 구현)

  • Kim, Han-Kil;Kim, Su-Jin;Lee, Hwan-Kyu;Jung, Hoe-Kyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.3
    • /
    • pp.602-608
    • /
    • 2014
  • Smartphones have become commonplace to use smart, BYOD (Bring Your Own Device) spread the trend of domestic WLAN use is intensifying as a result, the security threat will be greatly increased. Even though WLAN vendors such as Cisco Systems Inc,. Aruba networks released WIPS, MDM, DLP etc, however, these solutions can not be easily introduced for small business due to high cost or administrative reasons. In this paper, without the introduction of expensive H/W equipment, in WLAN environments, packet analysis, AP, Station management, security vulnerabilities can be analyzed by the proposed intrusion detection system.

Evaluation of dimension stability according to UV-C ultrasonic cleaning of full arch artificial teeth made with DLP printer for photopolymerization (광중합용 DLP 프린터로 제작한 전악 인공치아의 UV-C 초음파 세척에 따른 체적 안정성 평가)

  • Kim, Dong-Yeon;Lee, Gwang-Young
    • Journal of Technologic Dentistry
    • /
    • v.43 no.3
    • /
    • pp.84-92
    • /
    • 2021
  • Purpose: The purpose of this study was to compare the dimension safety evaluation between a general ultrasonic cleaner and an ultrasonic cleaner equipped with UV-C (ultraviolet-C). Methods: An edentulous model was prepared. A denture base and an occlusal rim were fabricated, and scanning was performed. After scanning, a denture base and full arch artificial teeth were designed. The full arch artificial teeth were printed using a three-dimensional printer (n=10). The residual resin was washed with alcohol and then scanned (reference data). The printed specimens were classified and cleaned using a general ultrasonic cleaner (GU group) and an ultrasonic cleaner equipped with UV-C (UC group). After each washing, a rescan was performed (scan data). Reference data and scan data were superimposed using overlapping software. Data were statistically analyzed using the Mann-Whitney test (α=0.05). Results: In the deviation values of full arch artificial teeth, the GU group showed a high deviation of 18.02 ㎛ and the UC group showed a low deviation of 15.02 ㎛. The two groups demonstrated a statistically significant difference (p<0.05). Conclusion: Full arch artificial teeth prepared using photopolymerized resin were deformed according to the temperature of water generated in the ultrasonic cleaner. It is judged that there is no deformation according to the UV-C ultrasonic cleaner.

A Study on the Application Ratio of ASIR in Abdominal CT (복부 CT 검사에서 ASIR의 적용율에 대한 연구)

  • Kim, Hyeon-jin;Jeong, Bong-jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.95-101
    • /
    • 2019
  • The purpose of this study is to reduce the dose to the patient by different application of ASIR according to the Body Mass Index (BMI). In particular, we wanted to find out the application values of ASIR that are most appropriate for the standard weight. Studies have shown that increasing the application of ASIR to 50% in patients with a body mass index of 25 or less reduces CTDIvol 58.17% and DLP 60.49% compared to using only FBP. A comparative analysis of the noise by the BMI and the SNR values found that the noise increased as the BMI increased, but the application of ASIR resulted in less noise than the FBP alone. In addition, it was found that the more ASIR is applied, the more SNR is increased.

Image Evaluation and Exposure Dose with the Application of Tube Voltage and Adaptive Statistical Iterative Reconstruction of Low Dose Computed Tomography (저 선량 전산화단층촬영의 관전압과 적응식 통계적 반복 재구성법 적용에 따른 영상평가 및 피폭선량)

  • Moon, Tae-Joon;Kim, Ki-Jeong;Lee, Hye-Nam
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.261-267
    • /
    • 2017
  • The study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying filter back projection (FBP), the existing test method, and adaptive statistical iterative reconstruction (ASIR) with different values of tube voltage during the low dose computed tomography (LDCT). With the image reconstruction method as basis, chest phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of tube voltage (100 kVp, 120 kVp). For image evaluation, back ground noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were measured, and, for dose assessment, CTDIvol and DLP were measured respectively. In terms of image evaluation, there was significant difference in ascending aorta (AA) SNR and inpraspinatus muscle (IM) SNR with the different amount of tube voltage (p < 0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120 kVp were 2.6 mGy with no-ASIR and 2.17 mGy with 20%-ASIR respectively, decreased by 0.43 mGy, and the values with 100 kVp were 1.61 mGy with no-ASIR and 1.34 mGy with 20%-ASIR, decreased by 0.27 mGy. In terms of DLP, the measured values with 120 kVp were $103.21mGy{\cdot}cm$ with no-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$ (about 16.7%), and the values with 100 kVp were $63.84mGy{\cdot}cm$ with no-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$ (about 16.7%). At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise.