• Title/Summary/Keyword: DLP

Search Result 225, Processing Time 0.024 seconds

Preparation of Photocurable Slurry for DLP 3D Printing Process using Synthesized Yttrium Oxyfluoride Powder (합성 불산화 이트륨 분말을 이용한 DLP 3D 프린팅용 광경화성 슬러리 제조)

  • Kim, Eunsung;Han, Kyusung;Choi, Junghoon;Kim, Jinho;Kim, Ungsoo
    • Korean Journal of Materials Research
    • /
    • v.31 no.9
    • /
    • pp.532-538
    • /
    • 2021
  • In this study, a spray dryer is used to make granules of Y2O3 and YF3, and then Y5O4F7 is synthesized following heat treatment of them under Ar gas atmosphere at 600 ℃. Single and binary monomer mixtures are compared and analyzed to optimize photocurable monomer system for DLP 3D printing. The mixture of HEA and TMPTA at 8:2 ratio exhibits the highest photocuring properties and low viscosity with shear thinning behavior. The optimized photocurable monomer and synthesized Y5O4F7 are therefore mixed and applied to printing process at variable solid contents (60, 70, 80, & 85 wt.%) and light exposure times. Under optimal light exposure conditions (initial exposure time: 1.2 s, basic exposure time: 5 s), YOF composites at 60, 70 & 80 wt.% solid contents are successfully printed. As a result of measuring the size of the printed samples compared to the dimensions of the designed bar type specimen, the deviation is found to increase as the YOF solid content increases. This shows that it is necessary to maximize the photocuring activity of the monomer system and to optimize the exposure time when printing using a high-solids ceramic slurry.

A Study on the Debinding Process of High Purity Alumina Ceramic Fabricated by DLP 3D Printing (DLP 3D 프린팅으로 제작된 고순도 알루미나 세라믹 탈지 공정 연구)

  • Lee, Hyun-Been;Lee, Hye-Ji;Kim, Kyung-Ho;Ryu, Sung-Soo;Han, Yoonsoo
    • Journal of Powder Materials
    • /
    • v.27 no.6
    • /
    • pp.490-497
    • /
    • 2020
  • The 3D printing process provides a higher degree of freedom when designing ceramic parts than the conventional press forming process. However, the generation and growth of the microcracks induced during heat treatment is thought to be due to the occurrence of local tensile stress caused by the thermal decomposition of the binder inside the green body. In this study, an alumina columnar specimen, which is a representative ceramic material, is fabricated using the digital light process (DLP) 3D printing method. DTG analysis is performed to investigate the cause of the occurrence of microcracks by analyzing the debinding process in which microcracks are mainly generated. HDDA of epoxy acrylates, which is the main binder, rapidly debinded in the range of 200 to 500℃, and microcracks are observed because of real-time microscopic image observation. For mitigating the rapid debinding process of HDDA, other types of acrylates PETA, PUA, and MMA are added, and the effect of these additives on the debinding rate is investigated. By analyzing the DTG in the 25 to 300℃ region, it is confirmed that the PETA monomer and the PUA monomer can suppress the rapid decomposition rate of HDDA in this temperature range.

Evaluation of marginal and internal accuracy of provisional crowns manufactured using digital light processing three-dimensional printer (DLP 방식의 3D 프린터로 제작된 임시 보철물의 변연 및 내면 정확도 평가)

  • Noh, Mi-Jun;Lee, Ha-Bin;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.44 no.2
    • /
    • pp.31-37
    • /
    • 2022
  • Purpose: The aim of this study was to evaluate the accuracy of provisional crowns manufactured using a milling machine and a digital light processing (DLP) printer. Methods: A full-contour crown was designed using computer-aided design software. Provisional crowns of this design were manufactured using a milling machine and using a DLP three-dimensional (3D) printer (N=20). The provisional crowns were digitized with an extraoral scanner, and 3D deviation analysis was applied to the scanned data to confirm their accuracy. An independent t-test was performed to detect the significant differences, and the Kolmogorov-Smirnov test was used for analysis (α=0.05). Results: No significant differences were found among the precision of marginal surface between the printed and milled crowns (p=0.181). The trueness of marginal and internal surfaces of the milled crowns were statistically higher than those of the printed crowns (p=0.024, p=0.001; respectively). Conclusion: The accuracy of provisional crowns manufactured using a milling machine and a 3D printer differed significantly except with regards to the precision of the internal surface. However, all the crowns were clinically acceptable, regardless of the manufacturing method used.

Evaluation of Modeling Design and Dyeability of DLP 3D Printed Textiles (DLP 3D Printed Textile의 유연성 향상을 위한 모델링 디자인 및 염색성 평가)

  • Shim, Yeon Je;Kim, Hyunjin;Kim, Hye Rim
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.3
    • /
    • pp.375-389
    • /
    • 2022
  • 3D printing has been considered a key technology, leading the fourth industrial revolution. However, 3D printed textile still has a lot of limitations to overcome before it can be adopted as a clothing material in terms of design, flexibility and dyeability. This study aims to provide modeling design for imparting the flexibility and post-dyeing process for 3D printed textiles. The modeling types were designed to test the flexibility of 3D printed textiles. The post-dyeing process was evaluated through dye absorption depending on the resin and modeling types, respectively. The results were as follows: two types of modeling (Modeling A and B) were designed with a ring structure to test the flexibility of the 3D printed textiles. The 3D printed textiles with ring-based structure Modeling A had flexibility regardless of the hardness of resin types. In the dyeability test, softening resin (S-Resin) and hardening resin (H-Resin) were found to have good dyeability with acid dye and direct dye, respectively. The condition of S-Resin with acid dye and H-Resin with direct dye was controlled by dye absorption rate.

Optical System Design of Compact Head-Up Display(HUD) using Micro Display (마이크로 디스플레이를 이용한 소형 헤드업 디스플레이 광학계 설계)

  • Han, Dong-Jin;Kim, Hyun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6227-6235
    • /
    • 2015
  • The HUD has recently been downsized due to the development of micro display and LED technology as a see through information display device, gradually expands the application areas. In this paper, using a DLP micro display device designed a compact head-up display(HUD) optical system for biocular observation of the image exhibition area 5 inches. It was analyzed for each design element of the optical system in order to design a compacted HUD. DLP, projection optical system and concave image combiner were discussed the design approach and the characteristics. Through a connection structure analysis of each optical system, detailed design specifications were set up and designed the optical system in detail. Put a folded configuration in the form of a white diffuse reflector between the projection lens and concave image combiner was designed to be independent, respectively. Distance of the projected image is adjustable up to approximately 2m ~ infinity and observation distance is 1m. Resolution could be recognized by 1 ~ 2pixels in HD($1,280{\times}720pixels$) class, various characters and symbols could be read. In addition, color navigation map, daytime video camera and thermal imaging cameras can be displayed.

The clinical usefulness of 64 channel MDCT and 128 channel DSCT in coronary CT angiography (관상동맥 전산화단층촬영에서 64 channel MDCT와 128 channel DSCT의 임상 유용성 평가)

  • Choi, Nam-Gil;Choi, Jae-Seong;Han, Jae-Bok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4411-4417
    • /
    • 2010
  • This study was retrospectively to compare the exposure dose and the imaging quality in coronary CT angiography by using the 64 channel multidetector computed tomography and the 128 channel DSCT. Effective dose was calculated dose length product (DLP) by multiplied the convention factor of chest (0.017). Imaging quality was assessed by radiologists using the 5-point Likert scale. The DLP was ranged from 851 to $1277mGy{\cdot}cm$ (mean: 17.23 mSv) in the 64 channel MDCT and from 82 to $110mGy{\cdot}cm$ (mean: 1.58 mSv) in the of 128 channel DSCT, respectively. The score of imaging quality was respectively $3.31{\pm}0.62$ in 64 channel MDCT and $4.05{\pm}0.46$ in the 128 channel DSCT. The exposure dose of 128 channel DSCT has decreased 1ess 1/10. The score of imaging quality was significant difference between two modalities and the frequency (>4 good) in the 128 channel DSCT is about three times than that of the 64 channel MDCT. Therefore, the 128 channel DSCT in coronary CT angiography is clinically more effective modality for both investigators and patients.

Comparison of Image Quality and Dose between Intra-Venous and Intra-Arterial Liver Dynamic CT using MDCT (MDCT를 이용한 역동적 간 컴퓨터단층촬영 검사에서 정맥과 동맥 주입법에 따른 영상의 화질 및 선량 비교)

  • Ji-Young, Kim;Ye-Jin, Cho;Hui-Hyeon, Im;Ju-Hyung, Lee;Yeong-Cheol, Heo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.123-129
    • /
    • 2023
  • The purpose of this study was to analyze differences in imaging quality and dose difference between intra-venous (IV) and intra-arterial (IA) liver dynamic computed tomography (CT). Herein, retrospective, blinded analysis was conducted to analyze signal-to-noise and contrast-to-noise ratios in cases of patients who underwent IV or IA liver dynamic CT for transarterial chemoembolization (TACE), an interventional procedure for hepatocellular carcinoma. The dose length product (DLP) value stored in Picture Archive and Communication System (PACS) was used to calculate the effective dose and thereby compare differences in the dose between the two methods. The mean liver and spleen signal to noise ratio (SNR) was greater in IV-liver dynamic CT than in IA-liver dynamic CT; however, contrast to noise ratio (CNR) was higher in IA-liver dynamic CT than in IV-liver dynamic CT. However, there were no differences in DLP and effective dose between the two methods. In conclusion, our findings showed that IA-liver dynamic CT showed a similar effective dose and superior CNR compared with IV-liver dynamic CT. Further studies must analyze 3D angiography CT of the hepatic artery to clearly distinguish the feeding artery, which is the essential step in interventional procedures for hepatocellular carcinoma.

Comparisons of Image Quality and Entrance Surface Doses according to Care Dose 4D + Care kV in Chest CT (Chest CT에서 Care Dose 4D+Care kV에 따른 화질과 입사표면선량 비교)

  • Kang, Eun-Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.45-51
    • /
    • 2022
  • This study compared DLP values along with phantom entrance surface doses and the image quality of chest CT scans made using a Care Dose 4D+Care kV System, scans that are made using only the Care Dose 4D function, and scans that are made with changes made by applying 80 kVp, 100 kVp, 120 kVp, and 140 kVp to the Care Dose 4D and tube voltage to search for methods to maintain the highest image quality with minimal patient doses. It was shown that DLP values decreased 6.727% when scans were taken with Chest Care Dose 4D + Care kV semi 100 and 6.481% when scans were taken with Chest Care Dose 4D + Care kV. With Chest Non as a standard, skin surface doses decreased 16.519% when scans were taken with Chest Care Dose 4D + Care kV semi 100 and 15.705% when scans were taken with Chest Care Dose 4D + Care kV. With comparisons of image quality, when comparisons were made with Chest Non, comparisons made of SNR values and CNR values in all scanning conditions including Care Dose 4D + Care kV showed that there were no significant differences at P>0.05. Imaging using Chest Care Dose 4D + Care kV in chest CT showed that exposure doses decreased similarly to result values gained from the best conditions through manual adjustments of kV and mAS, and there were no significant differences in image SNR and CNR. If the Chest Care Dose 4D + Care kV function is used, image quality is maintained and patient exposure to radiation can be reduced.

Case study of Lighting method to improve TV news viewers' attention span -Based on KBS News 9 Lighting Method Analysis- (TV뉴스 시청자의 집중도 향상을 위한 조명 기법의 사례 연구 -KBS 9시 뉴스 조명 기법 분석을 중심으로-)

  • Han, Hak-Soo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.12
    • /
    • pp.97-107
    • /
    • 2009
  • Television News has significant impact on the information analysis of viewers by delivering world news to anonymous individuals everyday. We need to pay more attention to resolution considering the fact that even slight facial expression and the dress of TV anchor can be noticed by viewers in the high definition age, called HD TV, by radical changes in broadcasting situation. As a result, the beauty of expression that lighting technology has is extremely important in the high definition age. In news broadcast, as a phenomenon according to this change in trend, people have been looking for change in order to break with traditional TV news production by adopting DLP(Digital Lighting Processing) or LED(Light Emitting Diode). This effort has contributed to creating proper picture quality appropriate for HD TV. Nowadays Digital imaging is creating new trend in TV news production method from traditional analog-based lighting environment thanks to the development of IT(Information Technology) and digitalized lighting equipment. This change has led to building of HD studio and appropriate sets and lighting system. There are film set and projector which projects image on the screen and PDP, LCD, and DLP which has been used widely in recent years and LED which is often used as background in news program as examples, which has appeared since 1990s with HD TV. In this article, I analyzed the KBS News 9 lnce 1990s with in order to research the influence of television image component on the alyzed the KBS of TV article, I. I wille uggest the category of TV anchor image formulation in delivering information by means of lnce 1990s with based on the analysis result.

제 12회 대한민국멀티미디어기술대상 수상작

  • Korean Associaton of Information & Telecommunication
    • 정보화사회
    • /
    • s.175
    • /
    • pp.30-31
    • /
    • 2005
  • 정보통신 핵심 기술과 제품 개발을 촉진하기 위해 마련된 '제12회 대한민국 멀티미디어 기술대상' 에서 삼성전자(주)의 Slim DLP TV가 대통령상을 수상했다. 정보통신부가 주최하고 한국경제신문사와 한국정보통신산업협회가 공동으로 주관한 이번 행사에서는 대통령상을 비롯해 7개 제품과 기술이 수상했다.

  • PDF