• Title/Summary/Keyword: DLP

Search Result 222, Processing Time 0.045 seconds

Analysis of Exposure Dose According to Chest and Abdomen Combine CT Exam Method (CT 흉·복부 통합검사 시 선량분석)

  • Mo, KyeongHwan;Han, DongKyoon;Lim, HyunSoo;Jeon, WooJin
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.401-408
    • /
    • 2014
  • The purpose of this study is confirmed to usefulness between division exam and combine exam of chest and abdomen according to comparing chest and abdomen radiation dose of division exam and combine exam in CT exam method. This study was conducted on patients who were admitted to the E hospital from July 2013 to March 2014 underwent CT studies for the diagnosis of chest and abdomen disease. In study result, male dose were more higher than female dose according to gender analysis of exposure dose that combine exam effective dose were male $33.10{\pm}2.75mSv$, female $31.66{\pm}3.12mSv$ and chest exam effective dose were male $9.07{\pm}2.62mSv$, female $8.30{\pm}2.18mSv$(p<0.05). And, division exam dose and combine exam dose were similar in gender comparison (p>0.05). And, combine exam effective dose, only chest exam effective dose, only abdomen exam effective dose were more higher than DRL(Diagnostic Reference Level) in comparison of patient exposure dose with DRL (p<0.05). In conclusion, chest-abdomen combine exam dose and division exam dose were similar. The chest-abdomen combine study can be used as follow-up and emergency trauma patients. That study will be reduce exam time and the occurrence risk of side effect of the contrast medium.

A Comparative Study on the Graphics Usage by Terrestrial Broadcasters TV News - Focusing on the Evening Main News of KBS, MBC, and SBS - (지상파방송사 TV뉴스의 그래픽 현황 비교 연구 -KBS, MBC, SBS 저녁 메인뉴스 중심으로-)

  • Kim, Sang-cheol;Kim, Kwang-Ho
    • Journal of Digital Contents Society
    • /
    • v.16 no.3
    • /
    • pp.397-406
    • /
    • 2015
  • Terrestrial broadcasters are devoting great efforts in order to increase sense of reality that would help viewers feel as if they were watching events on site by producing-depth, differentiated news and offering a variety of information to them. They maximize news video graphic effects by replacing news set and install large display units, rail camera, and Jimmy Jib camera. This study aims to grasp whether there is any difference among the main evening news of the three major terrestrial broadcasters. KBS, MBC, and SBS used 18%, 15%, and 12% of graphic usage hours respectively while the number of graphic usage cases amounted to 267, 329, and 276 for each of them. The number of cases where in-depth news report hours exceeded three minutes that require increasingly more virtual reality graphic technology production was 16 for KBS, 7 for MBC, and 5 for SBS. MBC showed the highest number of uses in graphics while KBS showed more graphic use hours than the other two. There have been a number of preceding studies on news contents, but it is significant that this study looked at how much graphics technologies are used in such news video contents.

Effects of Dandelion on Oxygen Free Radical Generating and Scavenging System of Brain in Streptozotocin-Induced Diabetic Rats (서양민들레가 Streptozotocin으로 유발한 당뇨 횐쥐의 뇌조직 중 유해 활성산소 생성 및 제거 효소계에 미치는 영향)

  • 김명주;조수열
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.3
    • /
    • pp.500-505
    • /
    • 2002
  • Many studies have shown that hyperglycemia leads to an increase of lipid peroxidation in diabetic patients and animals, reflecting a rise reactive oxygen species production. It is increasingly recognized that brain is another site of diabetic organ damage. Accordingly, this study was to investigate the effect of dandelion on oxygen free radical generating and scavenging system of brain in streptozotocin (STZ)-induced diabetic rats. Male Wistar rats were divided into diabetic (control) and diabetic-dandelion supplemented groups. Dandelion was supplemented for 4 weeks with dandelion leaf and root powder (DLP, DRP) or dandelion leaf and root water extract (DLW, DRW) based on 11.4 g of raw dandelion/kg diet. Diabetes was induced by single injection STZ (55 mg/kg B.W., i.p.)in a citrate buffer. Oxygen free radical generating enzymes, cytochrome P-450, amino-pyrine N-demethylase, aniline hydroxylase and xanthine oxidase, were lowered in dandelion supplemented-groups compared to the control group. Superoxide dismutase, catalase and gluthathione peroxidase activities of brain were also lower in dandelion leaf and root supplemented-group than in the control group, whereas glutathione S-transferase activity and gluthathione content were increased in dandelion supplemented-groups compared to the control group. With regard to the lipid peroxidation products, the malondialdehyde content of brain was lower in dandelion supplemented groups. Therefore, it could be suggested that powder and water extract of dandelion leaf or root are beneficial in preventing diabetic complication from lipid peroxidation and free radical in brain of diabetic rat brain.

Short-term Mechanical Circulatory Support with a Centrifugal Pump - Results of Peripheral Extracorporeal Membrane Oxygenator According to Clinical Situation

  • Lee, Woo-Surng;Chee, Hyun-Keun;Song, Meong-Gun;Kim, Yo-Han;Shin, Je-Kyoun;Kim, Jun-Seok;Lee, Song-Am;Hwang, Jae-Joon
    • Journal of Chest Surgery
    • /
    • v.44 no.1
    • /
    • pp.9-17
    • /
    • 2011
  • Background: A peripheral extracorporeal membrane oxygenator (p-ECMO) has been developed to support patients who are dying due to a serious cardiopulmonary condition. This analysis was planned to define the clinical situation in which the patient benefits most from a p-ECMO. Material and Methods: Between June 2007 and Aug 2009, a total of 41 adult patients used the p-ECMO. There were 23 males and 18 females (mean age $54.4{\pm}15.1$ years). All patients had very unstable vital signs with hypoxia and complex cardiac problems. We divided the patients into 4 groups. In the first group, a p-ECMO was used as a bridge to cardiac operation. In the second group, patients did not have the opportunity to undergo any cardiac procedures; nevertheless, they were treated with a p-ECMO. In the third group, patients mostly had difficulty in weaning from CPB (cardiopulmonary bypass) after cardiac operation. The fourth group suffered from many complications, such as pneumonia, bleeding, infections, and LV dysfunction with underlying cardiac problems. All cannulations were performed by the Seldinger technique or cutting down the femoral vessel. A long venous cannula of $DLP^{(R)}$ (Medtronic Inc, Minneapolis, MN) or $RMI^{(R)}$ (Edwards Lifesciences LLC, Irvine, CA) was used together with a 17~21 Fr arterial cannula and a 21 Fr venous cannula. As a bypass pump, a Capiox emergency bypass system ($EBS^{(R)}$; Terumo, Tokyo, Japan) was used. We attempted to maintain a flow rate of $2.4{\sim}3.0\;L/min/m^2$ and an activated clotting time (ACT) of around 180 seconds. Results: Nine patients survived by the use of the p-ECMO. Ten patients were weaned from a p-ECMO but they did not survive, and the remainder had no chance to be weaned from the p-ECMO. The best clinical situation to apply the p-ECMO was to use it as a bridge to cardiac operation and for weaning from CPB after cardiac operation. Conclusion: Various clinical results were derived by p-ECMO according to the clinical situation. For the best results, early adoption of the p-ECMO for anatomical correction appears important.

고효율 태양전지를 위한 ICP-RIE기반 결정질 실리콘 표면 Texturing 공정연구

  • Lee, Myeong-Bok;Lee, Byeong-Chan;Park, Gwang-Muk;Jeong, Ji-Hui;Yun, Gyeong-Sik
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.315-315
    • /
    • 2010
  • 결정질 실리콘을 포함하는 태양전지의 광전효율은 표면에 입사되는 태양광의 반사를 제외하면 흡수된 광자에 의해 생성되는 전자-정공쌍의 상대적인 비율인 내부양자효율에 의존하게 된다. 실제 생성된 전자-정공쌍은 기판재료의 결정상태와 전기광학적 물성 등에 의해 일부가 재결합되어 2차적인 광자의 생성이나 열로서 작용하고 최종적으로 전자와 정공이 완전히 분리되고 전극에 포집되어 실질적인 유효전류로 작용한다. 16% 이상의 고효율 결정질 실리콘 태양전지양산이 요구되고 있는 현실에서 광전효율 개선 위해 가장 우선적으로 고려되어야 할 변수는 입력 태양광스펙트럼에 대한 결정질 실리콘 표면반사율을 최소화하여 광흡수를 극대화하는 것이라 할 수 있다. 이의 해결을 위하여 대기와 실리콘표면 사이의 굴절률차이가 크면 클수록 태양광스펙트럼에 대한 결정질 실리콘의 광반사는 증가하기 때문에 상대적으로 낮은 굴절률의 $SiO_x$$SiN_x$와 같은 반사방지막을 광입력 실리콘표면에 증착하여 광반사율 저감공정을 적용하고 있다. 이와 더불어 결정질 실리콘표면을 화학적으로 혹은 플라즈마이온으로 50-100nm 직경의 바늘형 피라미드형상으로 texturing 함으로 광자들의 다중반사 등에 기인하는 광흡수율의 증가를 기대할 수 있기 때문에 태양전지효율 개선에 긍정적인 영향을 미치는 것으로 이해된다. 본 실험에서도 고효율 다결정 실리콘 태양전지 양산공정에 적용 가능한 ICP-RIE기반 결정질 실리콘표면에 대한 texturing 공정기술을 연구하였다. Double Langmuir 플라즈마 진단시스템(DLP2000)을 적용하여 사용한 $SF_6$$O_2$ 개스유량과 챔버압력, 플라즈마 파워에 따른 이온밀도, 전자온도, 포화이온전류밀도, 플라즈마포텐셜의 공간분포를 모니터링하였고 texturing이 완료된 시료에 대하여 A1.5G 표준태양광스펙트럼의 300-1100nm 파장대역에서 반사율을 측정하여 그 변화를 관찰하였다. 본 연구에서 얻어진 결과를 간략히 정리하면 Si texturing에 가장 적합한 플라즈마파워는 100W, $SF_6/O_2$ 혼합비는 18:22, 챔버압력은 30mtorr 등이고 이에 상응하는 플라즈마의 이온밀도는 $2{\sim}3{\times}10^8\;ions/cm^3$, 전자온도는 14~15eV, 포화전류밀도는 $0.014{\sim}0.015mA/cm^2$, 플라즈마포텐셜은 38~39V 범위 등이었다. 현재까지 얻어진 최소 평균반사율은 14.2% 였으며 최적의 texturing패턴 플라즈마공정 조건은 이온에 의한 Si표면원자들의 스퍼터링과 화학반응에 의한 증착이 교차하는 플라즈마 에너지 및 밀도 상태인 것으로 해석된다.

  • PDF

The Evaluation of Dose Reduction and Quality of Images According to 80 kVp of Scan Mode Change in Pediatric Chest CT (소아 흉부 CT 검사에서 관전압 80 kVp 조건으로 스캔 모드별 방사선량 감소와 화질 평가)

  • Kim, Gu;Kim, Gyeong-Rip;Lee, Eun-Sook;Cho, Hee-Jung;Sung, Soon-Ki;Moon, Seul-ji-a;Kwak, Jong-Hyeok
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.284-292
    • /
    • 2019
  • To evaluate the usefulness of pediatric chest CT scans by comparing the dose, examination time, and image quality by applying Helical mode, High-pitch mode, and Volume Axial mode to minimize the radiation exposure and obtain high diagnostic value. Revolution (GE Healthcare, Wisconsin USA) was used to divide PBU-70 phantom into Helical mode, High-pitch mode, and Volume Axial mode. After acquiring images, ROI is set for each image, heart, bone, lung, and back-ground air, and the average value is obtained by measuring CT number (HU) and noise (SD). SNR and CNR were measured and compared with DLP values provided directly by the equipment. Determining statistical significance Statistical analysis was performed using ONE-WAY-ANAOVA using SPSS 21.0. In this experiment, it was possible to inspect at a short time without deterioration of image quality with the lowest dose when using volume axial mode. Although the detector coverage of 16 cm is limited to all pediatric chest CT scans, it is recommended to be actively used in pediatric patients, and further study is needed to apply other test sites in volume axial mode.

Comparative evaluation of the subtractive and additive manufacturing on the color stability of fixed provisional prosthesis materials (고정성 임시 보철물 재료의 색 안정성에 대한 절삭 및 적층가공법의 비교평가)

  • Lee, Young-Ji;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.2
    • /
    • pp.73-80
    • /
    • 2021
  • Purpose: The purpose of this study is to compare the color stability of provisional restorative materials fabricated by subtractive and additive manufacturing. Materials and Methods: PMMA specimens by subtractive manufacturing and conventional method and bis-acryl specimens by additive manufacturing were fabricated each 20. After immersing specimens in the coffee solution and the wine solution, the color was measured as CIE Lab with a colorimeter weekly for 4 weeks. Color change was calculated and data were analyzed with one-way ANOVA and the Tukey multiple comparisons test (α = 0.05). Results: PMMA provisional prosthetic materials by subtractive manufacturing showed superior color stability compared to bis-acryl provisional prosthetic materials by additive manufacturing (P < 0.05), and showed similar color stability to the PMMA provisional prosthetic materials by conventional method (P > 0.05). Conclusion: It is recommended to fabricate provisional restorations by subtractive manufacturing in areas where esthetics is important, such as anterior teeth, and consideration of the color stability will be required when making provisional prosthetic using additive manufacturing.

Image Quality and Dose Assessment According to Examination Mode during Head CT Examination (두부 CT 검사 시 검사 모드에 따른 화질 및 선량평가)

  • Gang, Heon-Hyo;Choi, Woo-Jeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.437-444
    • /
    • 2021
  • To evaluate the usefulness of Volume Axial Mode by comparing analyzing the exposure dose of the patients and the quality of each images from CT images obtained from high pitch mode using the local phantom or volume axial mode to determine the usefulness of he volume axial mode in diagnosing the head and cervical disease in adults. High Pitch Mode, Helical Mode, and Volume axial Mode as adult phantom were tested according to 70 kVp, 80 kVp, and 100 kVp tube voltages during an adult frontal CT scans. The equipment used was GE's Revolution (GE Healthcare, Wisconsin USA) model and iMED X-ray Phantom. The exposure dose of phantom was compared using the images obtained from each protocol, and the image quality was compared by calculating SNR and CNR by setting ROI on each image. When examined using Volume Axial Mode, the exposure dose of phantom was measured 17.12% lower than Helical Mode, 5.35% lower than High Pitch Mode, and both SNR and CNR were improved. Volume Axial Mode is a useful test that reduces investigation time without table movement using high speed rotary scanner, and in which exposure dose is reduced and image quality is improved by acquiring images in a short time of 0.28 seconds of phantom than using High Pitch Mode and Helical Mode. In addition, the fast testing time of Volume Axial Mode can be seen as the biggest advantage CT scans of emergency patients or patients with physical discomfort.

A Study on the Radiation Dose in Computed Tomographic Examinations (전산화단층촬영 검사의 방사선 선량에 관한 연구)

  • Lim, Chung-Hwang;Cho, Jung-Keun;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.381-389
    • /
    • 2007
  • The purpose of this study is investigation of radiation dose in CT scan. Data were collected from various references and organizations. Doses measured by CT scanners of each medical organization were analyzed and they were calculated through the examination protocol. The results are as follows : 1. $CTDI_W$ value per 100mAs measured by Head Phantom was the highest in <4-slice MDCT scanner> of 24.20 mGy. $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 2. $CTDI_W$ value per 100 mAs measured using body phantom was the highest in <4-slice MDCT scanner> of 13.58 mGy and the $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 3. When contrast medium was not used, the highest scanner was <16 slice MDCT> of $818.83\;mGy{\codt}cm$ in exposure dose in brain scan(p < 0.05). When the contrast medium was used, the highest scanner was <4 slice MDCT> and its average was $1,460.77\;mGy{\cdot}cm$(p < 0.1). 4. When the contrast medium was not used, the highest scanner was <16-slice MDCT> of $521.63\;mGy{\cdot}cm$ on average in terms of the exposure dose in chest inspection(p<0.05). when the contrast medium was used, the highest scanner was found in 8 slice MDCT scanner and its average was $1,174.70\;mGy{\cdot}cm$. There was no statistically significant difference among scanners. 5. When the contrast medium was not used, the highest scanner was <16-slice MDCT> and its average was $856.27\;mGy{\cdot}cm$ in exposure dose on the abdomen-pelvis(p<0.05). when the contrast medium was used, the highest scanner was <16-slice MDCT> and its average was $1,720.64\;mGy{\cdot}cm$ on average (p < 0.05). 6. When the contrast medium was not used, the highest scanner was <8-slice MDCT> and its average was $612.07\;mGy{\cdot}cm$ in exposure dose in liver inspection(p < 0.05). when the contrast medium was used, the highest scanner was <8-slice MDCT scanner> and its average was $2,197.93\;mGy{\cdot}cm$ in exposure dose(p < 0.1). seventy six point two percent of medical facilities were in risk of radiation exposure while the number of phase was three to four times in their dose inspection of contrast medium.

  • PDF

Survey of Caffeine levels in the Favorite Diets of Children (어린이 기호식품 중 카페인 함량에 대한 조사)

  • Lee, E-Na;Kim, Hee-Jin;Im, Ji-Young;Kim, Jeoung-A;Park, Hye-Young;Ryu, Ju-Young;Ko, Kwang-Rack;Kim, Hyung-Sik
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.3
    • /
    • pp.173-178
    • /
    • 2007
  • Children may respond differently to the caffeine from adults because they have different physiologic makeup and are functionally immature in terms of hepatic and renal function; this leads to the slower clearance of caffeine in early life. Therefore, children are often assumed to be more susceptible to caffeine effects. Alarge number of food supplements may interfere with these processes, and therefore caffeine exposure may have more serious consequences for children than for adults, irrespective of sensitivity. However, there has never been a national dietary survey on caffeine intakes in children. The purpose of our study was to identify caffeine intakes and beverage sources of caffeine in a representative sample of children in Busan, Korea. Caffeine intakes were based only on beverages included in the Continuing Surveys of Food Intakes by individuals. The caffeine content of the beverages ranged from 2.8 to 65.2mg/100ml for cola, soft drinks, and teas. Caffeine was not completely absent from caffeine-free colas, juice, and milk. In this study, cola-type beverages were an important dietary source of caffeine in the children. Daily caffeine intake for children was estimated to range from 12.5 to 250 mg/day. In general, the acceptable daily intake (ADI) of caffeine should cover the entire population including children. Therefore, special considerations should be needed regarding the consumption of soft drinks containing caffeine to children below the 12 years of age.