Z-axis automatic tube current modulation technique automatically adjusts tube current based on size of body region scanned. The purpose of the current study was to compare noise, and radiation dose of multi-detector row CT (MDCT) of lower extremity performed with Z-axis modulation technique of automatic tube current modulation with manual selection fixed tube current. Fifty consecutive underwent MDCT venography of lower extremity with use of a MDCT scanner fixed tube current and Z-axis automatic tube current modulation technique (10, 11 and 12 HU noise index, $70{\sim}450\;mA$). Scanning parameters included 120 kVp, 0.5 second gantry rotation time, 1.35:1 beam pitch, and 1 mm reconstructed section thickness. For each subject, images obtained with Z-axis modulation were compared with previous images obtained with fixed tube current (200, 250, 300 mA) and with other parameters identical. Images were compared for noise at five levels: iliac, femoral, popliteal, tibial, and peroneal vein of lower extremity. Tube current and gantry rotation time used for acquisitions at these levels were recorded. All CT examinations of study and control groups were diagnostically acceptable, though objective noise was significantly more with Z-axis automatic tube current modulation. Compared with fixed tube current, 2-axis modulation resulted in reduction of CTDIvol (range, $-6.5%{\sim}-35.6%$) and DLP (range, $-0.2%{\sim}-20.2%$). Compared with manually selected fixed tube current, 2-axis automatic tube current modulation resulted in reduced radiation dose at MDCT of lower extremity venography.
The purpose of this experiment intend to evaluate the quality of the image based on the orbit and basal ganglia with high radiosensitivity for the noise, SNR and dose using the five kinds patient fixing pad in brain phantom MDCT(BrillianceTM CT 64 slice, PHILIPS, Netherward). The noise had a higher values in AP than those of others, but the SNR was lower in AP than those of others. The SNR was higher in UP than those of RP, PP, SP and AP. The UP, RP and PP were no statistically significant(p>0.05), whereas it was significant difference between UP, RP, PP and SP, AP(p<0.05). This is causes of the noise difference is generated due to the differences in the radiation absorption dose in accordance with each the component of the absorbed dose level of the detector according to the reference line and each of SOML when the radiation exposured. The CTDIvol(mGy) and DLP of orbit and basal ganglia were 56.95, 911.50, respectively. There is no difference between both mean dose. In conclusion, it is possible to distinguish among a kind of 5 patient fixing pad by using brain phantom MDCT. Overall, patient fixing pad of UP, RP and PP based on a brain phantom MDCT can provide useful information.
The aim of this study was to assess the effect of exposure factors such as kVp and mA applied by BMI on the image quality and patients absorbed dose of Coronary angiography in CT. Each data sets were into 4groups with different exposure values : Group A at 100kVp, 240mAs, Group B at 120kVp, 240mAs, Group C at 100kVp, 270mAs and Group D at 120kVp, 270mAs, and the mean of the scores of 4 groups was calculated for image quality as 4grades that is, 1(poor), 2(fair), 3(good) and 4(very good). Patient absorbed dose was calculated as DLP on the monitor. In case of absorbed dose, deviation in 2groups at 100kVp was 5.6 $mGy{\cdot}cm$, 11 $mGy{\cdot}cm$, was at 120kVp(DLP) with p<0.05. There was rather difference between groups with 100kVp or 120kVp respectively but the gaps were very little. No significant correlation was found between exposure factors and image quality in any images assessed(p>0.05), and the image quality was sufficient for diagnosis. As we applying coronary angiography, the selection of adequate exposure factors considering BMI identified might be effective for reduction of patient absorbed dose, improvement of image quality and diagnostic accuracy.
Using the 3D printing method in the product manufacturing is a very innovative and useful technology. However, in the field of jewelry, it is a limited technology used only in a field of manufacturing process. To overcome this limitations in the jewelry production process, most popular and easy 3D printing method was selected, and the printing time and condition was limited. In this study, to find out the 3D printing method applicability to jewelry work manufacturing, the prototypes through casting and non-casting methods were completed and compared. As a result, the FDM printing method has a very positive advantage in terms of cost and time, but there is a disadvantage that the layered structure is not erased on the surface and the completeness of the surface forming is poor due to the residue of the filament generated during the printing process. The DLP printing method has the advantage that the surface treatment is even and completion is high, while the cost and time are inefficient. However, both printing methods were found to be suitable for the use of jewelry manufacturing, and if the efficient printing method was selected for the design of the jewelry in the future, better work research could be conducted.
Journal of the Institute of Electronics Engineers of Korea SP
/
v.49
no.4
/
pp.40-48
/
2012
This paper models the hue shift phenomenon and proposes a hue correction method to give perceptual matching between projector with and without additional white channel. To quantify the hue shift phenomenon for whole hue angle, 24 color patches with the same lightness are frist created along equally-spaced hue angle, and these are displayed one by one both displays with different luminance levels. Next, each hue value of the patches appeared on the projector with additional white channel is adjusted by observers until the hue values of patches on both displays appear the same visually. After obtaining the hue shift values from the color matching experiment, these values are piecewise fit into six polynomial functions, which approximately determine shifted hue amounts for an arbitrary hue values of each pixel in projector with additional white channel and are utilized to correct them. Actually, an input RGB image is converted to CIELAB LCH color space to get hue values of each pixel and this hue value is shifted as much as the amount calculated by the functions of hue shift model for correction. Finally, corrected image is inversely converted to an output RGB image. For an evaluation, the matching experiment with several test images and the z-score comparisons were performed.
Purpose: The purpose of this study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying Filtered Back Projection(FBP), the existing test method, and Adaptive Statistical Iterative Reconstruction(ASIR) with different values of tube voltage during the Low Dose Computed Tomography(LDCT). Materials and Methods: With the image reconstruction method as basis, Chest Phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of Tube Voltage (100kVp, 120kVp). For image evaluation, Back ground noise, Signal to Noise ratio(SNR) and Contrast to Noise ratio(CNR) were measured, and, for dose evaluation, CTDIvol and DLP were measured respectively. The statistical analysis was tested with SPSS(ver. 22.0), followed by ANOVA Test conducted after normality test and homogeneity test. (p<0.05). Results: In terms of image evaluation, there was no outstanding difference in Ascending Aorta(AA) SNR and Infraspinatus Muscle(IM) SNR with the different values of ASIR application(p<0.05), but a significant difference with the different amount of tube voltage(p>0.05). Also, there wasn't noticeable change in CNR with ASIR and different amount of Tube Voltage (p<0.05). However, in terms of dose evaluation, CTDIvol and DLP showed contrasting results(p<0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120kVp were 2.6mGy with No-ASIR and 2.17mGy with 20%-ASIR respectively, decreased by 0.43mGy, and the values with 100kVp were 1.61mGy with No-ASIR and 1.34mGy with 20%-ASIR, decreased by 0.27mGy. In terms of DLP, the measured values with 120kVp were $103.21mGy{\cdot}cm$ with No-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$(about 16.7%), and the values with 100kVp were $63.84mGy{\cdot}cm$ with No-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$(about 16.7%). Conclusion: At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise. For the future, through the result of the experiment, it is considered that the method above would be recommended for follow-up patients or those who get health checkup as long as there is no interference on the process of diagnosis due to the characteristics of Low Dose examination.
The purpose of this study is to find out the factors that affect the patient's exposure dose during the abdominal CT scan using the bolus tracking technique, and reducing the radiation exposure to the patient during the abdominal CT scan using the bolus tracking technique by adjusting the delay time according to the corresponding factor. The experiment was divided into two parts, and the first experiment was conducted with 300 patients There were 188 males and 112 females, and their average age was 58±12.18(19~85). In the second experiment, 150 subjects (100 males and 50 females) who were undergoing their follow-up examination among the first experiment subjects, and the difference in dose before and after was compared by applying the delay time according to the influencing factor. As a result of the first experiment, there was a relationship between the arrival time of the contrast media and the heart rate, and it was found that the arrival time decreased as the heart rate increased for both men and women. As a result of the second experiment, the average dose of CTDIvol and DLP before/after applying the delay time according to the heart rate decreased 4.98 mGy and 5.33 mGy·cm in the male group, and 3.54 mGy and 3.88 mGy·cm in the female group. By applying proper delay time according to the patient's heart rate during abdominal CT scan with the bolus tracking technique, the radiation exposure dose of the patient can be reduced.
The Journal of the Korea institute of electronic communication sciences
/
v.18
no.2
/
pp.251-258
/
2023
In this paper, we propose DLP(Dual Linear Polarization) stack antenna for private network. The proposed antenna has general stack structure and design airgap between two substrate to obtain the maximum gain. Also, to improve cross polarization isolation, two feeding port is designed to separate for each substrate. The size of each patch antenna is 17.80 mm(W1)×16.70 mm(L1) for lower patch and 18.56 mm(W2)×18.73 mm(L2) for upper patch, which is designed on the FR-4 substrate which thickness (h) is 1.6 mm, and the dielectric constant is 4.3, and which is 40.0 mm(W)×40.0 mm(L) for total size of substrate. From the fabrication and measurement results, bandwidths of 100 MHz (4.74 to 4.84 GHz) for feeding port 1, and 150 MHz (4.67 to 4.82 GHz) for feeding port 2 are obtained on the basis of -10 dB return loss and transmission coefficient S21 is got under the -20 dB. Also, cross polarization isolation between each feeding port obtained
New display technologies including LCD and plasma panels and Digital Light Projection (DLP) systems all offer large screens and impressive picture quality. However, flat-panel displays require a sophisticated picture processing to let these panels perform at their optimum levels. This paper explains why motion compensating techniques combined with frame rate conversion and quasi-impulse driving reduces motion blur and film judder for flat panel displays and presents the IC and its system application using this technique.
프로젝터와 프로젝션 TV는 공통적으로 광학엔진내에 신호 처리된 영상 정보를 표시해주는 CRT(Cathode Ray Tube), LCD(Liquid Crystal Device), LCoS(Liquid Crystal on Silicon), 디지털 마이크로 미러 디바이스(Digital Micromirror Device;DMD)등의 디스플레이 소자가 사용된다. 최근 이러한 디스플레이 소자는 소형화·경량화 되어지는 추세에 있으며 무겁고 두꺼운 CRT보다는 LCD를 이용한 프로젝션 시스템들이 속속 출시되고 있다. LCoS 및 DMD를 이용한 시스템들도 출시 또는 개발되고 있는 실정이다. 특히, 현재까지는 LCD가 주류였지만, 고해상도 구현에 유리한 반면, 개발속도가 느린 LCoS에 비해 하이 콘트라스트(High Contrast) 구현에 탁월하고 개발 속도가 빠른 DMD를 이용한 프로젝션 시스템의 개발 및 출시가 주로 진행되고 있다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.