• Title/Summary/Keyword: DGS

Search Result 270, Processing Time 0.027 seconds

Design of An Amplifier using DGS Block (DGS 방식 DC Block을 이용한 증폭기의 설계)

  • 이경희;정용채
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.3
    • /
    • pp.432-438
    • /
    • 2001
  • In this paper, after applying Defected Ground Structure(DGS) to DC block, changes of gap and length of λ/4 coupled line are investigated by EM simulation and fabrication. As a result, on condition of the same output with the case using typical DC block, the gap between λ/4 coupled line is widen from 0.1 mm to 0.46 mm by 0.36 mm and the length of λ/4 coupled line gets shorter from 17.7 mm to 13.2 mm by 4.5 mm. Also three type power amplifiers using blocking capacitor, typical DC block and DGS DC block are fabricated and investigated. At first, when S parameter characteristics of each amplifier are considered at frequency band of 3.2 +-0.O5 GHz, every amplifier has similar characteristics of gain and S parameter. Second when the output power of amplifiers is 25 dBm after putting CW signal of 3.2 GHz into three type amplifiers, the difference of dominant signal and 2nd harmonic signal using blocking capacitor, typical DC block and DGS DC block is each -44.83 dBc, -66.84 dBc and -64.33 dBc. Therefore harmonic characteristics of amplifiers using typical DC block and DGS DC block is almost same.

  • PDF

Impedance Analysis of DGS Slot in Spectral Domain and Its Application of LPF(Low Pass Filter) (스펙트럴 영역에서 DGS 슬롯 임피던스 특성 해석 및 LPF 응용)

  • Rhee, Seung-Yeop;Kim, On;Chang, Jae-Soo;Go, Jin-Hyun;Ha, Jae-Kwon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.4
    • /
    • pp.418-426
    • /
    • 2008
  • In this paper, investigations on the impedance characteristics of a DGS(Defected Ground Structure) slot in the groud plane of microstripline are presented in spectral domain and applied to the characteristic improvement of stepped impedance microstrip low pass filter(LPF). In this method, expressions for the impedance of a DGS slot are derived from self-reaction of the angular spectrum of plane waves and the discontinuity in the modal voltage. The numerical results are compared with those of the rigorous full-wave method and are shown to produce reasonably accurate data. And the stepped impedance microstrip low pass filter is designed and fabricated with the uniform and nonuniform DGS slots for improving the frequency responses. The experiments show that the proposed filter with slots in the ground plane has a wider stopband and sharper cutoff response.

A Novel Design of Frequency Multiplier Using Feedforward Technique and Defected Ground Structure (Feedforward와 Defected Ground Structure를 이용한 주파수 체배기 설계)

  • Park Sang-Keun;Lim Jong-Sik;Jeong Yong-Chae;Kim Chul-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.8 s.111
    • /
    • pp.725-731
    • /
    • 2006
  • A novel design of frequency multiplier using a feedforward technique and a defected ground structure(DGS) is proposed. The feedforward loop in the proposed frequency multiplier suppresses the fundamental component $(f_0)$, the dumb-bell or spiral shaped DGS diminish unwanted harmonics such as second, third and fourth. Due to the combination of the feedforward structure and the DGS, only the multiplied frequency component$(2f_0,\;3f_0,\;4f_0)$ appears at the output port and the other unwanted components are suppressed excellently. The frequency multiplier is designed at 1 GHz $(f_0)$, by the proposed technique and measured. The measured output power of $2f_0,\;3f_0$ and $4f_0$ is -2.59 dBm, -5.36dBm and -4.57dBm, respectively, when the input power is 0dBm.

Placement and Operation of Dispersed Generation Systems using Fuzzy Goal Programming (Fuzzy Goal Programming을 응용한 분산형전원의 설치 및 운영)

  • 송현선;김규호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.146-153
    • /
    • 2004
  • This paper presents the method for the placement and operation of dispersed generator systems(DGs) using fuzzy goal programming in distribution systems. For the placement and operation of DGs the problem is formulated with reduction of search spaces and flexibility of system situations. Especially, the original objective function and constraints are transformed by fuzzy goal programming to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithm.

A Study of WLAN Switch Stucture using DGS (DGS 구조를 이용한 WLAN용 스위치 구조 연구)

  • An Ka-Ram;Park Jun-Seok;Kim Hyung-Seok;Cho Hong-Goo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.295-297
    • /
    • 2004
  • A double-role double through switch with defected ground structure (DGS) is Proposed. The equivalent circuit for the proposed switch structure is derived based on equivalent circuit of newly proposed DGS unit structure. The equivalent circuit parameters of DGS unit are extracted by using the circuit analysis method The on/off operation of the proposed switch Is obtained by varying the capacitance in the ground metallic plane The experimental results show excellent insertion loss characteristic at on state and isolation characteristic at off state.

  • PDF

A Study on Operation Method of Power Distribution System Integrated with Dispersed Generation System (분산형전원이 도입된 복합배전계통의 운용방안에 대한 고찰)

  • Kim, Jae-Eon;Jo, Seong-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.6
    • /
    • pp.692-698
    • /
    • 1999
  • This paper analyzes the effect of DGS(Dispersed Generation System) on the voltage regulation of the traditional distribution system of which the voltage is controlled by the bank LDC(Line Drop Compensator). Through the simulation results for 22.9kV class distribution system with DGSs, some general relationships among the operating power factor and introduction limit of DGS, and the sending-end reference voltage determined by internal setting coefficients of the LDC are derived. Those relationships are that the introduction limit of DGS increases as the power factor of DGS goes from lagging to leading and also as the allowance of the sending-end reference voltage increases. From the relationships, a operation method of the power distribution system integrated with DGSs is proposed from the view point of the operating power factor of DGS and new voltage regulation method.

  • PDF

Fuzzy-GA Application for Allocation and Operation of Dispersed Generation Systems in Composite Distribution Systems (복합배전계통에서 분산형전원의 설치 및 운영을 위한 Fuzzy-GA 응용)

  • 김규호;이유정;이상봉;유석구
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.10
    • /
    • pp.584-592
    • /
    • 2003
  • This paper presents a fuzzy-GA method for the allocation and operation of dispersed generator systems(DGs) based on load model in composite distribution systems. Groups of each individual load model consist of residential, industrial, commercial, official and agricultural load. The problem formulation considers an objective to reduce power loss of distribution systems and the constraints such as the number or total capacity of DGs and the deviation of the bus voltage. The main idea of solving fuzzy goal programming is to transform the original objective function and constraints into the equivalent multi-objectives functions with fuzzy sets to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithm. The method proposed is applied to IEEE 12 bus and 33 bus test systems to demonstrate its effectiveness. .

A Study for DPDT Switch Design with Defected Ground Structure (DGS 구조를 이용한 DPDT 스위치 설계에 관한 연구)

  • An Ka-Ram;Jeoung Myeung-Sub;Lim Jae-Bong;Cho Hong-Goo;Park Jun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.3
    • /
    • pp.132-138
    • /
    • 2005
  • In this paper a DPDT(Double-Pole Double Through) switch with defected ground structure(DGS) is proposed. The equivalent circuit for the proposed switch structure is derived according to based on equivalent circuit of proposed DGS unit structure. The equivalent circuit parameters of DGS unit are extracted by using the circuit analysis method. The on/off operation of the proposed switch is obtained by varying the capacitance of the varactor diode at the defected ground plane. In the case of ON state, the insertion loss of the fabricated DPDT was shown under 1dB. And in OFF state, we found the rejection characteristic over 20dB at the designed frequency 2.45GHz. The experimental results show excellent insertion loss at on state and isolation at off state.

Optimal Capacity and Allocation of Distributed Generation by Minimum Operation Cost in Distribution Systems

  • Shim Hun;Park Jung-Hoon;Bae In-Su;Kim Jin-O
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.1
    • /
    • pp.9-15
    • /
    • 2005
  • In the operation of distribution systems, DGs (Distributed Generations) are installed as an alternative to extension and the establishment of substations, transmission and distribution lines according to the increasing power demand. In the operation planning of DGs, determining optimal capacity and allocation achieves economical profitability and improves the reliability of power distribution systems. This paper proposes a determining method for the optimal number, size and allocation of DGs in order to minimize the operation costs of distribution systems. Capacity and allocation of DGs for economical operation planning duration are determined to minimize total cost composed with power buying cost, operation cost of DGs, loss cost and outage cost using the GA (Genetic Algorithm).

Homogeneous Dual Composite Right/Left-Handed Metamaterial Using Subwavelength Defected Ground Structure(DGS) (Subwavelength 결함접지구조(defected grounded structure : DGS)를 이용한 Homogeneous Dual Composite Right/Left-Handed 메타물질 구현)

  • Park, Woo-Young;Lim, Sung-Joon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2242-2246
    • /
    • 2009
  • In this paper, a homogeneous dual composite right/left-handed (D-CRLH) transmission line (TL) is proposed by using a defected ground structure (DGS) on the ground plane. In order to satisfy a homogeneity condition of metamaterial, a subwavelength unit cell is designed by way of a spiral DGS and a meander stub. From a dispersion diagram, it is expected that the frequency bands for the left-handed (LH) property is 3.5 - 4.4 GHz. At 3.8 GHz in the LH band, backward propagating phenomenon is observed from full-wave analysis. The experimental results show that the proposed TL has a stop-band in 1.75 - 3.6 GHz.