• 제목/요약/키워드: DG (Distributed Generation)

검색결과 162건 처리시간 0.025초

전압변동과 부하량을 고려한 저압배전계통의 분산전원 설치용량 분석 (The Study on Permissible Capacity of Distributed Generation Considering Voltage Variation and Load Capacity at the LV Distribution Power System)

  • 문원식;조성민;신희상;이희태;한운기;추동욱;김재철
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.100-105
    • /
    • 2010
  • This paper describes a capacity of distributed generation which will be interconnected at low voltage distribution systems. In order to set the capacity of distributed generation, a voltage variation of distribution system is considered. Besides, the capacity of distributed generation is classified according to a capacity of pole transformer and loads. The system constructions in this paper are analyzed by using PSCAD/EMTDC. In the immediate future, it is expected to increase the installation of New and renewable energy systems which are generally interconnected to distribution power systems in the form of distributed generations like photovoltaic system, wind power and fuel cell. So the study of this kind would be needed to limit the capacity of distributed generation.

차세대전력공급네트워크(Micro-grid)의 운용제어앨고리즘 (An Operation and Control Algorithm of Micro-grid)

  • 노대석;김재언
    • 한국산학기술학회논문지
    • /
    • 제8권2호
    • /
    • pp.232-239
    • /
    • 2007
  • 전력산업의 구조개편과 더불어 분산전원의 배전계통연계운용 및 전력품질이 전력회사의 배전사업자, 구역전기사업자, 전기공급 신뢰도와 밀접한 관계에 있는 산업용 수용가들에게 많은 관심을 불러일으키고 있다. 최근, 이러한 주변정세는 차세대의 배전계통이 다수의 차세대 전력공급네트워크(Micro-grid)들로 구성될 것이라고 하는 예상을 전문가들로부터 제기되기에 이르렀다. 그러나, 제안된 Micro-grid는 몇몇의 분산전원과 전력품질을 보상하는 기기, 그리고 통신제어설비와 부하들로 구성된다는 기본적인 내용에 지나지 않는다. 따라서, 본 논문에서는 수용가에 고신뢰 고품질의 전력공급을 가능하게 하는 차세대 전력공급네트워크인 Micro-grid의 Topology와 그 운전제어앨고리즘을 제안한다.

  • PDF

배전계통에서 분산전원을 증가시키는 새로운 전압조정방법에 관한 연구 (A Study for Novel Voltage Regulation Increasing DG Introduction in Distribution Systems)

  • 손준호;김미영;노대석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.450_451
    • /
    • 2009
  • 최근 부하증가에 대한 안정적 전력공급과 환경문제 해결은 전 세계적 이슈로 등장되고 있으며, 그 해결책으로써 분산형전원(Distributed generation, DG)에 대한 관심이 높아지고 있다. DG는 경제적 효율적 이유로 기존 전력계통과 연계해 운전되는데, 태양광이나 풍력과 같은 재생에너지를 이용한 DG의 불확실하며 빈번한 출력변동은 배전계통의 전압조정을 어렵게 만든다. 배전계통의 전압조정을 위해 배전용변전소의 부하시 탭 변환기(Under Load Tap Changer, ULTC)가 이용되고 있다. ULTC는 부하변동에 따른 배전선로상 전압강하를 보상하는 선로 전압강하보상법(Line Drop Compensation, LDC)에 의해 조정된다. LDC 전압조정법에서, 측정된 뱅크전류와 미리 설정된 LDC 정정치(LDC parameters, 부하중심점 전압과 등가 임피던스)를 이용해 ULTC의 송출전압을 결정한다. LDC 정정치 설계시, 기존에는 ULTC 탭 동작횟수를 줄이는 것이 주요 목표였고, 이 목표는 DG 도입을 제한하는 큰 원인이 되고 있다. 그러므로 본 논문에서는 DG 도입을 증가시키는 새로운 ULTC 전압조정법을 제시하고 모델 배전계통 시뮬레이션을 통해 그 유효성을 확인한다.

  • PDF

Secondary Voltage Control for Reactive Power Sharing in an Islanded Microgrid

  • Guo, Qian;Wu, Hongyan;Lin, Liaoyuan;Bai, Zhihong;Ma, Hao
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.329-339
    • /
    • 2016
  • Owing to mismatched feeder impedances in an islanded microgrid, the conventional droop control method typically results in errors in reactive power sharing among distributed generation (DG) units. In this study, an improved droop control strategy based on secondary voltage control is proposed to enhance the reactive power sharing accuracy in an islanded microgrid. In a DG local controller, an integral term is introduced into the voltage droop function, in which the voltage compensation signal from the secondary voltage control is utilized as the common reactive power reference for each DG unit. Therefore, accurate reactive power sharing can be realized without any power information exchange among DG units or between DG units and the central controller. Meanwhile, the voltage deviation in the microgrid common bus is removed. Communication in the proposed strategy is simple to implement because the information of the voltage compensation signal is broadcasted from the central controller to each DG unit. The reactive power sharing accuracy is also not sensitive to time-delay mismatch in the communication channels. Simulation and experimental results are provided to validate the effectiveness of the proposed method.

Optimal Coordination of Overcurrent Relays in the Presence of Distributed Generation Using an Adaptive Method

  • Mohammadi, Reza;Farrokhifar, Meysam;Abyaneh, Hossein Askarian;Khoob, Ehsan
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1590-1599
    • /
    • 2016
  • The installation of distributed generation (DG) in the electrical networks has numerous advantages. However, connecting and disconnecting of DGs (CADD) leads to some problems in coordination of protection devices due to the changes in the short circuit levels in the different points of network. In this paper, an adaptive method is proposed based on available setting groups (SG) of relays. Since the number of available SG is less than possible CADD states, a classifying index (CI) is defined to categorize the several states in restricted setting groups. Genetic algorithm (GA) with a suitable objective function (OF) is used as an optimization method for the classification. After grouping, a modified coordination method is applied to achieve optimal coordination for each group. The efficiency of the proposed technique is demonstrated by simulation results.

Coordinated Voltage and Reactive Power Control Strategy with Distributed Generator for Improving the Operational Efficiency

  • Jeong, Ki-Seok;Lee, Hyun-Chul;Baek, Young-Sik;Park, Ji-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1261-1268
    • /
    • 2013
  • This study proposes a voltage and reactive coordinative control strategy with distributed generator (DG) in a distribution power system. The aim is to determine the optimum dispatch schedules for an on-load tap changer (OLTC), distributed generator settings and all shunt capacitor switching on the load and DG generation profile in a day. The proposed method minimizes the real power losses and improves the voltage profile using squared deviations of bus voltages. The results indicate that the proposed method reduces the real losses and voltage fluctuations and improve receiving power factor. This paper proposes coordinated voltage and reactive power control methods that adjust optimal control values of capacitor banks, OLTC, and the AVR of DGs by using a voltage sensitivity factor (VSF) and dynamic programming (DP) with branch-and-bound (B&B) method. To avoid the computational burden, we try to limit the possible states to 24 stages by using a flexible searching space at each stage. Finally, we will show the effectiveness of the proposed method by using operational cost of real power losses and voltage deviation factor as evaluation index for a whole day in a power system with distributed generators.

Unbalanced Power Sharing for Islanded Droop-Controlled Microgrids

  • Jia, Yaoqin;Li, Daoyang;Chen, Zhen
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.234-243
    • /
    • 2019
  • Studying the control strategy of a microgrid under the load unbalanced state helps to improve the stability of the system. The magnitude of the power fluctuation, which occurs between the power supply and the load, is generated in a microgrid under the load unbalanced state is called negative sequence reactive power $Q^-$. Traditional power distribution methods such as P-f, Q-E droop control can only distribute power with positive sequence current information. However, they have no effect on $Q^-$ with negative sequence current information. In this paper, a stationary-frame control method for power sharing and voltage unbalance compensation in islanded microgrids is proposed. This method is based on the proper output impedance control of distributed generation unit (DG unit) interface converters. The control system of a DG unit mainly consists of an active-power-frequency and reactive-power-voltage droop controller, an output impedance controller, and voltage and current controllers. The proposed method allows for the sharing of imbalance current among the DG unit and it can compensate voltage unbalance at the same time. The design approach of the control system is discussed in detail. Simulation and experimental results are presented. These results demonstrate that the proposed method is effective in the compensation of voltage unbalance and the power distribution.

마이크로터빈용 고속 영구자석 동기발전기 운전 특성 (Operating Characteristics of High Speed PM Synchronous Generator for Microturbine)

  • 안종보;정연호;강도현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.141-143
    • /
    • 2004
  • Distributed generation(DG) using microturbine will be adopted widely because of its various usages and merits such as high heat efficiency, environmental-friendliness. Commercialized DG using microtubine that rotates up to $60,000\~100,000[rpm]$ converters mechanical power to electricity by permanent magnet synchronous machine. This paper presents comparative test and simulation results of PMSM as generator. Test was done by diode rectifier and inverter. Parameters used in the simulation are driven from FEM analysis. Under various speed and load conditions, V-I characteristics matches well and it suggests the possibility of high speed PMSM as generator. DG operating at stand alone and grid connection mode will be developed.

  • PDF

풍력발전단지가 도입되는 한전 실배전계통의 전압변동에 대한 분석 (A Study on Voltage Variation in KEPCO Distribution System by Introducing the Wind Power Plant)

  • 황진수;정원재;강성수;김병숙;강흥식;김재언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.16-18
    • /
    • 2001
  • Recently, a study on operation in parallel between Distributed Generation(DG) unit and power distribution system has been growing interest in power distribution system. But, introducing the DG unit causes the problem due to rising the voltage variation on power distribution system. So, This paper presents the effect of introducing DG unit on distribution system. For this simulation, KEPCO distribution system is used.

  • PDF

독립형 마이크로그리드에서 비선형 부하에 대한 고품질 전압제어 (Effective Voltage Quality Control under Nonlinear Loads in Islanded Microgrid)

  • ;이홍희
    • 전력전자학회논문지
    • /
    • 제21권6호
    • /
    • pp.465-472
    • /
    • 2016
  • A nonlinear load causes harmonic distortion and hampers the performance of other loads or distributed generation (DG) sources connected to the point of common coupling (PCC). This study proposes a new control strategy to reduce harmonic components, such as fifth and seventh harmonics, at the PCC under nonlinear loads in islanded microgrids, which comprise more than two DG sources. The proposed control scheme enables the DG source to share the power commanded by the control center as well as to compensate for the voltage harmonics at the PCC. The reference current is estimated from the voltage harmonics and injecting power; thus, the control scheme is implemented without any additional hardware devices. The simulation and experimental results are presented to verify the effectiveness of the proposed control method.