• 제목/요약/키워드: DEGRADATION

검색결과 13,722건 처리시간 0.054초

LED 열화데이터의 신뢰성 분석 (Reliability Analysis of Degradation Data for LEDs)

  • 박창규
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제9권1호
    • /
    • pp.59-69
    • /
    • 2009
  • LEDs have rapidly replaced old light devices such as incandescent or fluorescent lamps, and have been widely applied in general lighting, signals, automobile, signs and others. Since LEDs are for both indoor and outdoor use, temperature and humidity inevitably affect its reliability. We explain the result of the degradation life test on LEDs, and guide to reliability analysis procedure. Analysis on reliability measures are performed by Weibull++6 program, and a common shape parameter of Weibull distribution on the LED is suggested. Also, we make a description of reliability analysis procedures for the degradation data using collected test data from degradation tests. Reliability analysis procedures are consisted of estimating degradation models and failure time, verifying of distribution and parameters of the distribution, and estimating of reliability measures. Finally, this paper suggests reliability analysis method for light characteristics on LEDs.

  • PDF

Phenol을 이용한 균주에 의한 Trichloroethylene분해 (Biodegradation of Triehloroethylene by a Phenol-Utilizing Bacterium)

  • 이숙희;홍성용;하지홍
    • 한국미생물·생명공학회지
    • /
    • 제22권2호
    • /
    • pp.203-209
    • /
    • 1994
  • The bacterial strain which utilizes phenol and degrade TCE was isolated from an industrial waste site. The bacterial strain was named as T5-7 and identified as an Acinetobacter species. After phenol-induction, the strain T5-7 removed TCE efficiently without cell growth. So, it seems that TCE degradation was not related to cell growth. TCE degradation increased when initial cell concentrations of phenol-grown T5-7 were high. In the presence of phenol, initial degradation of TCE was delayed but total amount of degradation was not affected at final stage. The strain cultured in 0.1% yeast extract did not degrade TCE, which indicates that phenol induction was essential to the TCE degradation.

  • PDF

원자가 제어에 의한 ZnO 세라믹 소자의 열화특성 연구 (A Study on the Degradation Characteristics of ZnO Ceramic Devices by the Valence Controls)

  • 소순진;김영진;소병문;박춘배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.157-160
    • /
    • 2001
  • Three sets of ZnO ceramic devices (reference samples with Matsuoka\`s composition; added 7o MgO, A1$_2$O$_3$, SiO$_2$) have been prepared by the conventional mixed oxide route. These additives were determined by the factors of valences and ionic radiuses. DC accelerated degradation test was performed for analysis of degradation characteristics versus the various additives. The conditions of DC degradation test were 115${\pm}$2$^{\circ}C$ for 12h. Using XRD and SEM, the Phase and microstructure of samples were analyzed respectively. E-J analysis was used to determine ${\alpha}$. Frequency analysis was accomplished to understand the relationship between R$\sub$g/ and $R_{b}$ with the electric stress at the equivalent circuit.

  • PDF

에폭시 몰드형 BCT의 절연열화 특성 (Characteristics of Insulation Degradation in Epoxy Mold Type BCT)

  • 송재주;이정철;임성훈;고석철;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제18권10호
    • /
    • pp.902-908
    • /
    • 2005
  • Various stresses (such as electrical stress, mechanical stress, environmental and electrochemical stress, and defects of structure) result in insulation degradation of epoxy mold type insulators. Since the insulation degradation of BCT(Bushing Current Transformer) and bushing proceeds during fabrication process or operation time due to these causes, various methods to reduce the degradation in their insulation ability have been suggested. In this paper, we investigated surface temperature increment of these insulators due to PD(partial discharge). After the voltage applied into the insulator to generate the artificial PD, the surface temperature of the insulator was measured with non-contact thermometer using infrared rays. It was confirmed through the analysis based on PD experiments that the procession in the insulation degradation of the insulator could be estimated through the measurement of the surface temperature in the insulator.

자연저감 모델링 연구 (Evaluation of Natural Attenuation of Petroleum Hydrocarbons in a Shallow Sand Aquifer: a Modeling Study)

  • 이진용;이명재;이강근;이민효;윤정기
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 총회 및 춘계학술발표회
    • /
    • pp.128-131
    • /
    • 2001
  • We evaluated natural attenuation of petroleum hydrocarbons in a shallow aquifer using a modeling study. The studied shallow aquifer was severely contaminated with petroleum hydrocarbons, especially toluene, ethylbenzene and xylenes (i.e, TEX). The exact spill history was not known. Therefor we used a contaminant level in May 1999 (the first sampling date of our integrated study) as an initial contaminant concentration. we calibrated required transport parameters using the contamination levels obtained from groundwater analyses in September of 1999. For fate and transport of the petroleum contaminants, five case 2 with sorption and degradation. case 3 with sorption and degradation (half decay constant compared with case 2), case 4 with degradation but no sorption, and case 5 with sorption but no degradation. For sorption and degradation, a linear sorption isotherm and first order irreversible decay was assumed, respectively and no additional contamination source to groundwater is also assumed.

  • PDF

펄프 표백시 산소와 이산화염소의 상호작용 (제1보) - 리그닌 모델화합물 연구 - (Interaction of Oxygen and Chlorine Dioxide in Pulp Bleaching (I) -Studies on the Degradation of Lignin Model Compounds-)

  • 윤병호;황병호;김세종;최경화
    • 펄프종이기술
    • /
    • 제35권3호
    • /
    • pp.74-78
    • /
    • 2003
  • The structural property of phenolic and non-phenolic lignin has an effect on the reaction rate of lignin by oxygen and chlorine dioxide respectively. Moreover, the undesirable degradation of cellulose followed by lignin degradation is influenced by chemical charge and reaction time. In this paper, several lignin model compounds were used to illuminate the interaction of oxygen and chlorine dioxide by varying the position of O and D(OD, DO, ODO and DOD), and gas chromatography method was used to investigate the degradation of lignin by determining the content of methoxyl groups in lignin. It was shown that structural properties of lignin models were more influential on the degradation and demethylation of lignin than the above combination. Combination of oxygen and chlorine dioxide, however, was more effective in degradation of lignin than only one stage, and three stages than two stages.

Degradation of Chlorinated Organic Compounds by Zero Valent Metals and an Electron carrier

  • Kim, Young-Hun
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 총회 및 춘계학술발표회
    • /
    • pp.53-56
    • /
    • 2001
  • The degradation of tetrachloroethene (PCE) and trichloroethene (TCE) by vitamin B$_{12}$, an electron mediator was examined when zero valent metals (ZVMs) were used as built electron donors. Dechlorination of PCE and TCE by iron and zinc in the presence of vitamin B$_{12}$ showed that the zinc and vitamin B$_{12}$ combination greatly enhances the reaction rates for both PCE and TCE, but iron and vitamin B$_{12}$ result in an increase in reactivity only for PCE degradation, not for TCE degradation in comparing with meta]s only. This result indicates vitamin B$_{12}$(I) Is active towards both PCE and TCE degradation while vitamin B$_{12}$(II) is active towards both PCE. Calculated activation energies for the dechlorination of PCE in the presence of Vitamin B$_{12}$ showed that vitamin B$_{12}$ lowered the activation energy about 40-60 kJ/㏖ for the both metals.the both metals.

  • PDF

시동/정지 반복에 따른 고분자전해질 연료전지의 성능 저하에 관한 연구 (A Study on Performance Degradation of PEMFC by Repetitive Startup/Shutdown Cycling)

  • 조유연;조은애;김정현
    • 한국수소및신에너지학회논문집
    • /
    • 제20권4호
    • /
    • pp.317-322
    • /
    • 2009
  • To investigate degradation mechanism of PEMFC operated with repetitive startup/shutdown cycling, i-V characteristics, impedance, cyclic voltamograms were measured. OCV decreased from 0.967 to 0.951 V while the cell voltage at 800mA/$cm^2$ from 0.657 to 0.563V, implying that the electrodes rather than membrane electrolyte was damaged during the cycling operation. Electrochemical analyses supported that the performance degradation could be mainly attributed to degradation of the electrodes such as a decrease in electrochemical active surface area rather than degradation of membrane.

TiO2현탁액에 의한 Brilliant Blue FCF의 광촉매 분해 (Photocatalytic Degradation of Brilliant Blue FCF with TiO2 Suspension)

  • 정갑섭;최수일
    • 한국환경과학회지
    • /
    • 제13권6호
    • /
    • pp.599-603
    • /
    • 2004
  • In a batch reactor, the characteristics of photocatalytic degradation of brilliant blue FCF in titanium dioxide suspension was studied under the irradiation of ultra-violet ray. Photocatalytic degradation in anatase type of TiO$_2$ was more effective than in rutile type of $TiO_2$ below the dosage of 5g. The degradation rate was slightly increased with decreasing initial pH of brilliant blue FCF aqueous solution, but rapidly increased with the addition of oxidant. Potassium bromate acted as more effective oxidant than ammonium persulfate. The photocatalytic degradation rate of brilliant blue FCF was pseudo-first order with rate constants of 0.012, 0.006 and $0.003min^{-1}$ at initial pH 3.1, 5.2 and 7.1 of brilliant blue FCF solution, respectively.

홍채 인식 성능에 영향을 미치는 화질 저하 요인 분석 (Analysis on Iris Image Degradation Factors)

  • 윤소원;김재희
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.863-864
    • /
    • 2008
  • To predict the iris matching performance and guarantee its reliability, image quality measure prior to matching is desired. An analysis on iris image degradation factors which deteriorate matching performance is a basic step for iris image quality measure. We considered five degradation factors-white-out, black-out, noise, blur, and occlusion by specular reflection-which happen generally during the iris image acquisition process. Experimental results show that noise and white-out degraded the EER most significantly, while others on EER were either insignificant or degradation images resulted in even better performance in some cases of blur. This means that degradation factors that affect the performance can be different from those based on human perception or image degradation evaluation.

  • PDF