• 제목/요약/키워드: DCPD법J-R 곡선

검색결과 1건 처리시간 0.013초

직류전위차법을 이용한 배관 균열 길이 측정에 관한 연구 (A Study on the Measurement of the Crack Length Using the DCPD Method for the Fracture Test of the Pipe Specimen)

  • 박재실;석창성
    • 대한기계학회논문집A
    • /
    • 제28권5호
    • /
    • pp.640-647
    • /
    • 2004
  • In order to perform elastic-plastic fracture mechanical analyses, fracture resistance curves for concerned materials are required. The unloading compliance method and the DCPD(Direct Current Potential Drop) method have been widely used for measuring the crack length and the extension for a standard specimen fracture resistance curve test. However it is difficult to apply the unloading compliance method to a real pipe fracture resistance curve test. The objective of this paper is to propose the calibration equation between the normalized crack length and the normalized electric potential, and to apply to pipe fracture experiments. For these, finite element analyses were performed with various current input locations and crack front configurations. Also the 4-point bending jig was manufactured for a pipe test and the DCPD method was used to measure crack extensions and crack lengths for a pipe test. The calculated crack length by the DCPD method agreed with the measured crack length within 5% error.