• Title/Summary/Keyword: DC-link

Search Result 1,020, Processing Time 0.028 seconds

A Second-order Harmonic Current Reduction with a Fast Dynamic Response for a Two-stage Single-phase Grid-connected Inverter

  • Jung, Hong-Ju;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1988-1994
    • /
    • 2014
  • In a single-phase grid-connected power system consisting of a DC/DC converter and a DC/AC converter, the current drawn from renewable energy sources has a tendency to be pulsated and contains second-order frequency ripple components, which results in several drawback such as a power harvesting loss and a shortening of the energy source's life. This paper presents a new second-order harmonic current reduction scheme with a fast dc-link voltage loop for two-stage dc-dc-ac grid connected systems. In the frequency domain, an adequate control design is performed based on the small signal transfer function of a two-stage dc-dc-ac converter. To verify the effectiveness of proposed control algorithm, a 1 kW hardware prototype has been built and experimental results are presented.

AC/DC Converter Design of The Korean Type Multi-Propulsion System (한국형 다중추진시스템의 주전력변환기 설계)

  • Jho Jeong-Min;Jung Byung-Su;Cho Heung-Jae;Kim Su-Yong;Sung Ho-Kyung
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.3
    • /
    • pp.127-133
    • /
    • 2005
  • Korean multi-propulsion system consists of a synchronous alternator driven by a gas turbine driving synchronous alternator coupled to a rectifier - DC link - DC/DC converter and traction system based on modification of the G7 high-speed train. The simulation modules include turbine engine system, alternator, rectifier, DC/DC converter and power management module. Simulation for the multi-propulsion system such as a modular is presented in order to confirm the system stability for loads with uncertain input impedances and control loop speeds. This paper deals with various simulation modules with a specific control loop to help the development of the real lame-scaled system.

Design and Implementation of a Power Conversion Module for Solid State Transformers using SiC MOSFET Devices (배전용 반도체 변압기 구현을 위한 SiC MOSFET 기반 전력변환회로 단위모듈 설계에 관한 연구)

  • Lim, Jeong-Woo;Cho, Young-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.2
    • /
    • pp.109-117
    • /
    • 2017
  • This paper describes the design and implementation of a unit module for a 10 kVA class 13.2 kV/220 V unidirectional solid-state transformer (SST) with silicon-carbide metal-oxide-semiconductor field-effect transistors. The proposed module consists of an active-front-end (AFE) converter to interface 1320 V AC voltage source to 2500 V DC link and an isolated resonant DC-DC converter for 500 V low-voltage DC output. The design approaches of the AFE and the isolated resonant DC-DC converters are addressed. The control structures of the converters are described as well. The experiments for the converters are performed, and results verify that the proposed unit module can be successfully adopted for the entire SST operation.

PRACTICAL EVALUATIONS OF PARASITIC RESONANT PWM DC-DC CONVERTERS FOR HIGH-POWER MEDICAL USE

  • H. Takano;J. Takahashi;Sun, J.M.;L... Gamage;M. Nakaoka
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.701-708
    • /
    • 1998
  • This paper presents a novel non-resonant PWM DC-DC converter for X-ray high-voltage power generator using the parasitic impedances of the high-voltage high-frequency link transformer with its output high-voltage control scheme and steady-state characteristics compared to the conventional series-parallel resonant DC-DC converter. The key point of this approach is to evaluate effectiveness of reduction of the turn ratio of the high-voltage high-frequency transformer on improvements in power conversion efficiency and the power factor applying a boost AC-DC converter as DC voltage source, especially in the long exposure term and light output load ranges.

  • PDF

Implementation of a B-Link Interface Logic for a SCI Interconnect (SCI 연결망의 B-Link 인터페이스 회로 구현)

  • 한종석;모상만;기안도;한우종
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.412-415
    • /
    • 1999
  • In this paper, we describe an implementation of the B-Link bus interface logic for a directory controller and a remote access cash controller in the SCI-based CC-NUMA multimedia server developed by ETRI . The CC-NUMA multimedia server is composed of a number of Pentium III SHV nodes and a SCI interconnection network. To communicate with remote nodes, each node has a CC-Agent which consists of a processor bus interface(PIF). a directory controller(DC), a remote access cash controller(RC), and two SCI 1ink controllers(LCs). The B-Link bus interface logic is developed for a directory controller and a remote access cash controller in order to communicate with a SCI link controller on a B-Link bus. It consists of a sending master controller a receiving slave controller, and asynchronous data buffers. And It performs a self-arbitration, a data packet transmission, a queue allocation, an early terminal ion. and a cut-through data path.

  • PDF

Formal Verification of I-Link Bus for CCA Board (CCA 보드를 위한 I-Link 버스의 정형 검증)

  • 남원홍;성창훈;최진영;기안도;한우종
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2000.04a
    • /
    • pp.45-47
    • /
    • 2000
  • 본 연구는 심볼릭 모델 체커 중의 하나인 SMV(Symbolic Model Verifier)를 이용하여 한국전자통신연구원(ETRI)에서 개발한 CCA(Cache Coherent Agent) 보드를 위한 I-Link Bus(Inside Bus)의 몇 가지 특성(property)들을 검증하여 I-Link Bus의 요구사항(requirement)이 만족됨을 보인다. 이 검증에서는 I-Link Bus의 모델을 SMV 입력 언어로 명세하며, 검증할 특성들을 시제 논리(temporal logic)를 이용하여 나타낸다. 검증을 통해서 I-Link Bus와 PIF(Processor Interface), DC(Directory Controller), RC(Remote access cache Controller)모듈들이 중재기 우선 순위, send 우선 순위, 중재 요청 신호의 관리, liveness등의 특성들을 만족한다라는 것을 검증하였다.

  • PDF

The grid-connected bidirectional PCS technology of the ESS (에너지 저장장치의 계통 연계형 양방향 PCS 기술)

  • Ko, Bong-Woon
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1280-1287
    • /
    • 2019
  • Grid-connected bidirectional PCS(Power Conditioning System) technology is a technology for implementing distributed renewable energy smart grid. And it is always charged by using power collected from solar modules and commercial grid power among vast smart grid systems, and stored when needed.It is a hybrid energy storage device that allows power to be released into the low voltage system. To this end, a PV input power converter with MPPT function, a bidirectional power converter for battery charging and discharging, and a DC Link input are output to a 3 phase 380V AC system, and if nessary, the bidirectional DC/DC converter We designed and developed a PCS with three power converter structures composed of inverters that perform battery charging. Currently, this system is applied to the site of Jeju, which is vulnerable to power outages and fire accidents.

AC-DC Converter Control for Power Factor Correction of Inverter Air Conditioner System (인버터 에어컨 시스템의 역률보상을 위한 AC-DC 컨버터 제어)

  • Park, Gwi-Geun;Choi, Jae-Weon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.154-162
    • /
    • 2007
  • In this paper, we propose a new AC-DC converter control method to comply with harmonics regulation(IEC 61000-3) effective for the inverter system of an air conditioner whose power consumption is less than 2,500W. There are many different ways of AC-DC converter control, but this paper focuses on the converter control method that is adopting an input reactor with low cost silicon steel core to strengthen cost competitiveness of the manufacturer. The proposed control method controls input current every half cycle of the line frequency to get unit power factor and at the same time to reduce switching loss of devices and acoustic noise from reactor. This kind of converter is known as a Partial Switching Converter(PSC). In this study, theoretical analysis of the PSC has been performed using Matlab/Simulink while a 16-bit micro-processor based converter has been used to perform the experimental analysis. In the theoretical analysis, electrical circuit models and equations of the PSC are derived and simulated. In the experiments, micro-processor controls input current to keep the power factor above 0.95 by reducing the phase difference between input voltage and current and at the same time to maintain a reference DC-link voltage against voltage drop which depends on DC-link load. Therefore it becomes possible to comply with harmonic regulations while the power factor is maximized by optimizing the time of current flow through the input reactor for every half cycle of line frequency.

The Load Current Observer Design for Torque Control of DC Meter (직류 전동기의 속도 토크 제어를 위한 부하 전류 관측기 설계)

  • Seo Young-Soo;Kim Eun-Gi;Kim Yong-Ju
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.155-158
    • /
    • 2001
  • In this paper, the Load Current Observer Design for 3-phase Voltage Type PWM Converter with DC Meter Load. The sinusoidal input current and unity input power factor are realised based on the estimated source voltage performed by the Load Current Observer using actual currents and DC link voltage.

  • PDF

Fault Diagnosis and Tolerant Control of DC-Link Voltage Sensor in Three-Phase AC/DC PWM Converters (3상 AC/DC PWM 컨버터의 직류링크 전압센서 고장 진단 및 허용 제어)

  • Kim, Soo-Cheol;Lee, Dong-Choon;Kim, Jang-Mok;Lee, Kyo-Beum
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.470-471
    • /
    • 2012
  • 본 논문은 루엔버거 관측기를 이용하여 직류링크 전압을 추정하고 추정치와 측정치를 비교하여 전압센서의 고장을 진단하는 방법을 제안한다. 또한 전압센서 고장 시에 추정치를 이용하여 제어함으로써 전압센서 고장 허용제어가 가능함을 보인다. 제안된 알고리즘은 시뮬레이션을 통해 그 타당성이 검증된다.

  • PDF