• Title/Summary/Keyword: DC-AC Inverter

Search Result 458, Processing Time 0.037 seconds

Battery Discharge System Configuration using Photovoltaic Simulator and PCS (태양광 시뮬레이터와 PCS를 이용한 배터리 방전시스템 구성)

  • Jeong, Da-Woom;Park, Sung-Min;Park, Seong-Mi;Park, Sung-Jun;Moon, Seung-Pil
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.3
    • /
    • pp.491-498
    • /
    • 2020
  • Recently, In the production line of batteries, charge and discharge tests are essential to verify battery characteristics. In this case, the battery charging uses a unidirectional AC/DC converter capable of output voltage and current control, and the discharge uses a resistive load. Since this method consumes energy during discharge, it must be replaced with a bi-directional AC/DC converter system capable of charging and discharging. Although it is difficult to replace the connected inverter part of the bi-directional AC/DC converter system due to the high cost, the spread of the solar-connected inverter rapidly increases as the current solar supply business is activated, and thereby the solar-connected type Inverter prices are plunging. If it can be used as a power converter for battery discharge without program modification of the solar-powered inverter, it will have competition. In this paper, propose a new battery discharge system using a combination of a photovoltaic DC/DC simulator and photovoltaic PCS using a battery to be used as a power converter for battery discharge without program modification of a low-cost photovoltaic inverter. In addition, propose an optimal solar characteristic curve for the stable operation of PCS. The validity of the proposed system was verified using a 500[W] class solar DC/DC simulator and a solar PCS prototype.

Regenerative Inverter System for Railway with DC Line Voltage Simulator (직류가선전압 모의장치를 적용한 지하철용 회생인버터 시스템)

  • Ji, Young-Hyok;Cho, Ki-Hyun;Jang, Su-Jin;Won, Chung-Yuen;Kim, Yong-Ki
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1515-1521
    • /
    • 2007
  • In this paper, a unified regenerative inverter system for railway with DC line voltage simulator is proposed. In order to determine the operation characteristics of the regenerative inverter, the DC line voltage simulator is proposed. The DC line voltage simulator, which is based on the AC-DC PWM converter, varies the DC voltage according to the fluctuating voltage which is measured in the actual DC line. The suitable operating point of the regenerative inverter can be estimated from the simulation result. The regenerative inverter operates two modes. When the DC line voltage exceed the operating point, already set up, it works as regenerative inverter to return the excessive power of DC line to the grid. When the DC line voltage is under the operating point, it works as active power filter to compensate harmonic currents. In this paper, the control algorithm of the DC line voltage simulator and that of the regenerative inverter is proposed.

  • PDF

Single-Phase Inverter Based on Class E dc/dc Converter for Automotive application

  • Boonyaroonate, Itsda;Mori, Shinsaku
    • Proceedings of the IEEK Conference
    • /
    • 2002.07b
    • /
    • pp.1027-1029
    • /
    • 2002
  • In this paper, we present the circuit topology and control scheme of single-phase dc/ac inverter based on class E dc/dc converter for automotive application. The proposed inverter consists of class E series resonant inverter and class E low dv/dt PWM synchronous rectifier with bi-directional switch.

  • PDF

A Study on the Off-Grid Photovoltaic Generation System with Sequential Voltage System (순차전압시스템을 고려한 독립형 태양광 발전 시스템에 관한 연구)

  • Kim, Gu-Yong;Bae, Jun-Hyung;Kim, Jong-Hae
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.364-367
    • /
    • 2020
  • This paper presents the off-grid PV-ESS system of sequential voltage control method applied to OR logic gate. The conventional off-grid PV-ESS system with the low-voltage series connection has problems due to capacity expansion. To solve these problems, this paper proposes a noble PV-ESS system with high efficiency and low cost by applying sequential voltage control technique of the high-voltage series connection of analog circuit type. The input voltage of DC to AC inverter can be converted from the low-voltage by the combinations of series connection of the conventional cascaded 24V solar cell unit modules to the high-voltage of 384V in battery. The output voltage of the battery was 384V as the each input voltage of three phase DC to AC inverter, and the each output voltage of three phase 10kW DC to AC inverter is designed to be AC380V@60Hz as the line to line rms voltage value. To prove the validity of the theoretical analysis by PSIM simulation, the operating characteristics of sequential voltage control system with OR logic gate were confirmed through experiment results.

Dual Utility AC Line Voltage Operated Voltage Source and Soft Switching PWM DC-DC Converter with High Frequency Transformer Link for Arc Welding Equipment

  • Morimoto Keiki;Ahmed NabilA.;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.366-373
    • /
    • 2005
  • This paper presents two new circuit topologies of the dc busline side active resonant snubber assisted voltage source high frequency link soft switching PWM full-bridge dc-dc power converters acceptable for either utility ac 200V-rms or ac 400V-rms input grid. These high frequency switching dc-dc converters proposed in this paper are composed of a typical voltage source-fed full-bridge PWM inverter, high frequency transformer with center tap, high frequency diode rectifier with inductor input filter and dc busline side series switches with the aid of a dc busline parallel capacitive lossless snubber. All the active switches in the full-bridge arms as well as dc busline snubber can achieve ZCS turn-on and ZVS turn-off transition commutation with the aid of a transformer leakage inductive component and consequently the total switching power losses can be effectively reduced. So that, a high switching frequency operation of IGBTs in the voltage source full bridge inverter can be actually designed more than about 20 kHz. It is confirmed that the more the switching frequency of full-bridge soft switching inverter increases, the more soft switching PWM dc-dc converter with a high frequency transformer link has remarkable advantages for its power conversion efficiency and power density implementations as compared with the conventional hard switching PWM inverter type dc-dc power converter. The effectiveness of these new dc-dc power converter topologies can be proved to be more suitable for low voltage and large current dc-dc power supply as arc welding equipment from a practical point of view.

A Second-order Harmonic Current Reduction with a Fast Dynamic Response for a Two-stage Single-phase Grid-connected Inverter

  • Jung, Hong-Ju;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1988-1994
    • /
    • 2014
  • In a single-phase grid-connected power system consisting of a DC/DC converter and a DC/AC converter, the current drawn from renewable energy sources has a tendency to be pulsated and contains second-order frequency ripple components, which results in several drawback such as a power harvesting loss and a shortening of the energy source's life. This paper presents a new second-order harmonic current reduction scheme with a fast dc-link voltage loop for two-stage dc-dc-ac grid connected systems. In the frequency domain, an adequate control design is performed based on the small signal transfer function of a two-stage dc-dc-ac converter. To verify the effectiveness of proposed control algorithm, a 1 kW hardware prototype has been built and experimental results are presented.

A Study on High Efficiency DC-AC Inverter of Solar Cell Power System Used in Fire Emergency Equipment (소방 비상용 태양전지 발전시스템의 고효율 직류-교류 인버터 설계에 관한 연구)

  • Kwak, Dong-Kurl;Lee, Bong-Seob
    • Journal of Energy Engineering
    • /
    • v.15 no.3 s.47
    • /
    • pp.181-187
    • /
    • 2006
  • This paper is proposed to a solar cell power system used in fire emergency equipment. Also it is designed with a high efficiency power converter in order to increase efficiency of power system. The controlling switches used in DC-DC booster chopper and DC-AC inverter are operated with soft switching, which is applied to resonant circuit method to reduce switching loss. The result is that the system gets to high efficiency. In this paper, A detection circuit of maximum power point of solar cell is described in this paper. And the performance evaluations for the photovoltaic power system of high efficiency are examined by the analysis of a new tracking controller with a maximum power $P_{max}$ detection of solar cell.

Extended Boost Single-phase qZ-Source Inverter for Photovoltaic Systems

  • Shin, Hyun-Hak;Cha, Honnyong;Kim, Hongjoon;Kim, Heung-Geun
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.918-925
    • /
    • 2014
  • This study presents an extended boost single-phase qZ-source DC-AC inverter for a single-phase photovoltaic system. Unlike the previously proposed single-phase qZ-source and semi-qZ-source inverters that achieve the same output voltage as that of the traditional voltage-fed full-bridge inverter, the proposed inverter can obtain higher output than input voltage. The proposed inverter also shares a common ground between DC input voltage and AC output voltage. Thus, possible ground leakage current problem in non-isolated grid-tied inverters can be eliminated with the proposed inverter. A 120 W prototype inverter is built and tested to verify the performance of the proposed inverter.

Output AC Voltage Control of a Three-Phase Z-Source Inverter by the Voltage Gain and Modulation Index Control (전압 이득과 변조지수 제어에 의한 3상 Z-소스 인버터의 출력 교류 전압 제어)

  • Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol;Yang, Seung-Hak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.1996-2005
    • /
    • 2010
  • This paper proposes a new method for constant control of the output AC voltage of a voltage-fed three phase Z-source inverter (ZSI), in case of Z-network DC voltage variation or heavy change of load. The modulation index for the reference output AC voltage of ZSI can be calculated by the basic definition of ZSI, the input DC voltage and capacitor voltage of Z-network. And, the output AC voltage of ZSI is controlled by the modified space vector modulation (SVM) with the calculated modulation index. By the proposed method, the modulation index of output AC voltage is closely following in the reference modulation index. The validity of the proposed method is verified using PSIM simulation. In case which the input DC voltage of ZSI is heavily changed from 100[V] to 70[V] (or to 150[V]) and in case which load is changed from $30[\Omega]$ to $10[\Omega]$, we confirmed that the output AC voltage of ZSI is constantly controlled by the proposed method because the modulation index of ZSI is also simultaneously changed. Finally, FFT and %THD of the output voltage and current of ZSI by the proposed method are analyzed.

Improved LCCT Z-Source DC-AC Inverter for Ripple Reduction of Input Current and Capacitor Voltage (입력전류와 커패시터 전압의 맥동저감을 위한 개선된 LCCT Z-소스 DC-AC 인버터)

  • Shin, Yeon-Soo;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1432-1441
    • /
    • 2012
  • In this study, an improved LCCT(Inductor-Capacitor-Capacitor-Trans) Z-source inverter(Improved LCCT ZSI) with characteristics of Quasi Z-source inverter(QZSI) and LCCT Z-source inverter(LCCT ZSI) is proposed. The proposed inverter can also reduce the voltage stress and input current/capacitor voltage ripples compared with conventional LCCT ZSI and Quasi ZSI. A two winding trans in Z-impedance network of the conventional LCCT ZSI is replaced by a three winding trans in the proposed inverter. To verify the validity of the proposed inverter, a DSP controlled hardware was made and PSIM simulation was executed for each method. Comparing the current and voltage ripples of each method under the condition of input DC voltage 70[V] and output AC voltage 76[Vrms], the input current and capacitor voltage ripple factors of the proposed inverter were low as 11[%] and 1.4[%] respectively. And, for generation of the same output AC voltage of each method, voltage stress of the proposed inverter was low as 175[V] under the condition of duty ratio D=0.15. As mentioned above, we could know that the proposed inverter have the characteristics of low voltage stress, low ripple factor and low operation duty ratio compared with the conventional methods. Finally, the efficiency according to load change/duty ratio and the transient state characteristics were discussed.