• 제목/요약/키워드: DC home appliance

검색결과 18건 처리시간 0.03초

LSEV용 SRM 구동시스템 (SR Drive System for LSEV)

  • 황형진;박한웅;안진우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.206-209
    • /
    • 2004
  • The switched reluctance motor(SRM) drive system provides a good adjustable speed and torque characteristics. SRM has the possibility of maintaining full power over a wide speed range. So, many attempts are being done from home appliances to industrial machinery and tools. Especially, a traction drive of an SRM is one of a good application for it's DC-series characteristic. However, because of the switching mechanism it has some disadvantage of noise and vibration. It is difficult to adopt to an appliance demanding silency. A noise simulation and design of 6/4 and 12/8 SRM was done in order to compare each other.

  • PDF

소음저감을 위한 EV용 SRM 구동 시스템의 설계 (Design of SRM for Low Noise Drive of EV)

  • 송현수;박성준;안진우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.840-843
    • /
    • 2003
  • The switched reluctance motor(SRM) drive system provides a good adjustable speed and torque characteristics. SRM has the possibility of maintaining full power over a wide speed range. So, many attempts are being done from home appliances to industrial machinery and tools. Especially, a traction drive of an SRM is one of a good application for it's DC-series characteristic. However, because of the switching mechanism, it has some disadvantage of noise and vibration. It is difficult to adopt to an appliance demanding silency. A noise simulation and design of 6/4 and 12/8 SRM was done in order to compare each other was done.

  • PDF

LSEV용 SR Drive System (SR Drive System for LSEV)

  • 송현수;안진우;안영주;박성준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.109-112
    • /
    • 2003
  • SRM(switched reluctance motor) provides a excellent adjustable speed and torque characteristics. SRM has the possibility of maintaining full power over a wide speed range. So, many attempts are being done from home appliances to industrial applications. Especially, a traction drive of an SRM is one of a good application for it's DC-series characteristic. However, because of the switching mechanism and reluctance torque, it has some disadvantage Of noise and Vibration. It is difficult to adopt to an appliance demanding silency. A performance and noise tests with 6/4 and 12/8 SRM were done to compare the characteristics.

  • PDF

스캘리턴 형상을 갖는 2상 BLDC 모터의 특성향상에 관한 연구 (A Study on the Performance Improvement for Skeleton type 2-Phase BLDC Motor)

  • 류세현;임태빈;정중기;하근수;장홍순;백수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.656-659
    • /
    • 2000
  • Recently, the skeleton type 2-phase brushless DC motor has been used in electric home appliance for low price and low energy consumption. In this paper, we analyzed a skeleton type 2-phase BLDC motor using time-step finite element method. And the validity of analysis is confirmed by measuring the flux distribution on the surface of permanent magnet and back-EMF. As well, we have calculated the dynamic characteristics of target motor considering the Hall sensor position. So, we have found the optimum switching position, and improved efficiency of 2-phase BLDC motor.

  • PDF

저속 전기자동차용 SRM의 구동특성 향상을 위한 제어시스템 (SR Drive System for LSEV)

  • 황형진;이동희;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1013-1015
    • /
    • 2004
  • SRM (switched reluctance motor) provides an excellent adjustable speed and torque characteristics. SRM has the possibility of maintaining full power over a wide speed range. So, many attempts are being done from home appliances to industrial applications. Especially, a traction drive of an SRM is one of a good application for it's DC-series characteristic. However, because of the switching mechanism and reluctance torque. it has some disadvantage of noise and vibration. It is difficult to adopt to an appliance demanding silency. Performance and noise tests with 6/4 and 12/8 SRM were excuted to compare the characteristics.

  • PDF

소음저감을 위한 EV용 SRM 및 제어기의 개발 (Development of Low Noise SRM Drive for EV Application)

  • 송현수;박성준;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.753-755
    • /
    • 2003
  • The switched reluctance motor(SRM) drive system provides a good adjustable speed and torque characteristics. SRM has the possibility of maintaining full power over a wide speed range. So, many attempts are being done from home appliances to industrial machinery and tools. Especially, a traction drive of an SRM is one of a good application for it's DC-series characteristic. However, because of the switching mechanism, it has some disadvantage of noise and vibration. It is difficult to adopt to an appliance demanding silency. A noise simulation of 6/4 and 12/8 SRM was done in order to compare each other, and the design was done carefully.

  • PDF

Tread Mill 구동용 BLDC 전동기 제어시스템 설계 및 운전특성 (Design and Drive Characteristics of BLDC Motor Control System for Tread Mill Application)

  • 안진우;이동희
    • 전력전자학회논문지
    • /
    • 제8권3호
    • /
    • pp.239-246
    • /
    • 2003
  • BLDC 전동기는 높은 효율과 출력밀도로 인하여, 현재 산업응용 분야에 널리 적용되고 있으며, 특히 고성능 제어 특성과 저소음 운전특성으로 인하여 가정용 전자제품의 활용도가 높아지고 있다. 본 논문에서는 제한적인 설계조건에서 요구성능을 만족하는 트레드 밀 구동용 BLDC 전동기를 설계하고, 이에 적합한 제어기를 제작하였다. 전동기설계에서 제한된 고정자 구조에 대하여, 제작의 용이성과 경제성을 고려하여 CAD와 FEM 해석을 통하여 영구자석의 형상을 설계하였다. 설계된 제어기는 트레드 밀의 안정된 구동과 성능을 위하여 운전자의 무게와 회전속도에 따라 학습된 제어기의 이득이 사용되도록 제작되었다. 제시된 트레드 밀 구동용 BLDCM과 제어기는 실험을 통하여 성능을 확인하였다.

국내 전철 및 가전제품을 대상으로 한 전자장 수준 실태조사 (A survey on the EMF Levels of Study and Electric Appliances in Korea)

  • 장성기;조용성;이석조;유승화;정경미;임준호
    • 한국산업보건학회지
    • /
    • 제15권1호
    • /
    • pp.71-81
    • /
    • 2005
  • The purposes of this study was to collect, analyze, and describe the MF exposure levels from subways in Korea and to measure and evaluate the MF levels generated from electric appliances used at general homes. The target subway lines were Seoul Metropolitan Line 1 to Line 8, Bundang Line, Incheon Line, Daegu Line, Gwangju Line, and Busan Line 1 and Line 2. We measured at each station in those subway lines and, all the train types (pantograph-equipped, motor-equipped, and common), and platform types(facing and isolating) were investigated by the distance(80, 200, 400 cm) from the train on 19 targeted subway lines using 3 magnetic field measuring devices (EMDEXII, Enertech Co.) during the survey from January till October, 2004. On the other hand, the levels of the 60Hz magnetic fields generated from 14 items of home electric appliances such as electric blankets, hair dryers, electric razors, etc. were measured at 10 general homes using 5 EMDEXII meters with a sampling interval of 1.5 second by the distance(surface, 30, 50, 100, 300cm ) from the target electric appliances. The survey results in the whole subway lines examined in this study were as follows; Seoul Metropolitan Line 4 using AC(alternating current) power source showed the highest mean value of $2.85{\mu}T$, followed by Seoul Metropolitan Line 1 running between Seoul and Incheon using AC($2.78{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Uijongbu using AC($2.73{\mu}T$), Bundang Line using AC($1.79{\mu}T$), Seoul Metropolitan Line 1 connected from Yongsan using AC($1.67{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Suwon using AC($0.79{\mu}T$), and so on. In general, the intensity of the magnetic field in the subway systems in Korea was significantly higher when using AC($2.14{\pm}0.91{\mu}T$) than when using DC($0.29{\pm}0.44{\mu}T$) power source. Among the home electric appliances examined, microwave ovens showed the highest mean value of $7.69{\mu}T$, followed by hair dryers($6.47{\mu}T$), vacuum cleaners($5.27{\mu}T$), televisions ($2.26{\mu}T$), electric blankets($1.38{\mu}T$), personal computers ($0.81{\mu}T$), and so on. Two items of electric appliances showed the excess value of $0.2{\mu}T$ at the distance of 30cm in the MF exposure level; electric razors $1.58{\pm}2.13{\mu}T$ and vacuum cleaners $0.48{\pm}0.44{\mu}T$. As a whole, this study showed a tendency that the shift of the MF levels according to the increase of distance from the electric appliances was lower than those of the results surveyed in UK and USA. As a result, this study is expected to suggest meaningful data for the future study in exposure assessment of magnetic fields and for the establishment of guidelines for subways and electric appliances in Korea. More detailed and large scaled exposure assessment studies should be performed continuously to get the various and useful information on health risk assessment of MFs in Korea.