• 제목/요약/키워드: DC feeding system

검색결과 66건 처리시간 0.022초

전기철도 절연구분장치의 효율적 운용에 관한 연구 (A Study on Efficient Operation of Dead Section in Electric Railway)

  • 박정균;최현영;류형선;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.416-418
    • /
    • 2001
  • In the feeding system of electric railways it is necessary to divide the power lines for either ac or dc system. At this dead section, the system is damaged by the abrupt change of the coming-in power. This paper present the relationships. Between the feeding system and the trail-cars, and the counter plans to reduce the electrical arc and the breakdown at the dead section.

  • PDF

가동 자석형 선형 직류 전동기의 설계 (Design of a Moving Magnet Type Linear DC Motor)

  • 정헌준;김용;백수현;윤신용;김필수;권순도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.224-227
    • /
    • 1998
  • Linear motors are increasingly employed as direct actuators replacing the more conventional systems composed by a rotating motor and a mechanical device. Linear DC motor is useful in a high speed and high accuracy positioning system with a feedback controller. Because of these advantages, linear DC motors have already been used as motors of pen recorders and magnetic disk storage devices, these are moving coil type linear DC motors as these movers are light. Moving magnet type linear DC motor has advantages at long stroke motors because its mover's feeding wires for driving is not necessary. This paper is concerned with the analysis of linear DC motor that is moving magnet type with unipolar. In order to analyze the dynamic behaviour a mathematical model based on a simplified field analysis developed. A two dimensional finite element field solution is employed in order to illustrate the effect of yoke saturation and motor performance. It is deduced the relation between the limit value of the thrust of the linear DC motor and the dimension of the yokes.

  • PDF

인천 국제공항청사 경전철 도입에 따른 고조파 영향 분석 (Harmonic Evaluation of An Imported IAT(Intra Airport Transit) System in Incheon International Airport)

  • 이준경;이승혁;김진오;정현수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.788-793
    • /
    • 2005
  • This paper presents harmonic evaluation of an IAT(Intra Airport Transit) system in Incheon International Airport. It will be used electric vehicles with 80 kW per car that are produced Mitsubishi Heavy Industries Ltd, and one car is constructed with SIV(Static Inverter), VVVF(Variable Voltage and Variable Frequency) and two induction motor. The operated vehicles in the IAT system are rapidly changing DC load, and at a feeding substation, 3-phase electric power is transferred to DC 750 V by rectifier. Since, vehicles are also changing continuously, the voltages for the DC load fluctuate in the IAT system, and moreover, the fluctuating voltages generate high-order harmonics. This means that there is the difficulty in maintaining power quality in KEPCO systems' side. Therefore, the power quality of the IAT system in Incheon International Airport is evaluated using PSCAD/EMTDC simulator in the paper. The THD(Total Harmonic Distortion) of voltages and TDD(Total Demand Distortion) of currents, indices are calculated for the IAT system using the results of PSCAD/EMTDC dynamic simulation.

  • PDF

Battery Energy Storage Based Voltage and Frequency Controller for Isolated Pico Hydro Systems

  • Singh, Bhim;Rajagopal, V.
    • Journal of Power Electronics
    • /
    • 제9권6호
    • /
    • pp.874-883
    • /
    • 2009
  • This paper deals with an integrated voltage and frequency (VF) controller for isolated asynchronous generators (IAG) driven by a constant power pico-hydro uncontrolled turbine feeding three-phase four-wire loads. The proposed VF controller is used to control the frequency and voltage of an IAG with load leveling. Such a VF controller is also known as an integrated electronic load controller (IELC) which is realized using an isolated star/polygon transformer with a voltage source converter (VSC) and a battery at its DC bus. The proposed generating system with a VFC is modeled and simulated in MATLAB along with Simulink and Simpower system (SPS) toolboxes. The simulated results are presented to demonstrate the performance of an isolated asynchronous generator feeding three-phase four-wire loads with neutral current compensation.

계통연계형 태양광발전시스템을 위한 고주파 DC 링크 인버터 (High-Frequency DC Link Inverter for Grid-connected PV System)

  • 정영석;유권종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.46-49
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kVA) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kVA high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier. four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

Improvement of Tracking Accuracy of Positioning Systems with Iron Core Linear DC Motors

  • Song, Chang-Kyu;Kim, Gyung-Ho
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제6권1호
    • /
    • pp.31-35
    • /
    • 2005
  • Higher productivity requires high-speed motion of machine tool axes. The iron core linear DC motor (LDM) is widely accepted as a viable candidate for high-speed machine tool feed unit. LDM, however, has two inherent disturbance force components, namely cogging and thrust force ripple. These disturbance forces directly affect the tracking accuracy of the feeding system and must be eliminated or reduced. In order to reduce motor ripple, this research adapted the feedforward compensation method and neural network control. Experiments carried out with the linear motor test setup show that these control methods are effective in reducing motor ripple.

리니어모터를 이용한 초정밀 공기정압안내면 개발 (Development of a Aerostatic Guideway Driven by the Linear Motor)

  • 박종하;황주호;박천홍;홍준희
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.36-40
    • /
    • 2003
  • In order to discuss the availability of aerostatic guideways driven by the coreless linear motor to ultra precision machine tools, a prototype of guideway is designed and tested in this research. A coreless linear DC motor with the continuous force of 156N and a laser scale with the resolution of $0.01\mu\textrm{m}$ are used as the feeding system. The experiments are performed on the static stiffness, motion accuracy, positioning accuracy, microstep response and variation of velocity. The guideway also has $0.21\mu\textrm{m}$ of positioning error and $0.09\mu\textrm{m}$ of repeatability, and it shows the stable response against the $0.01\mu\textrm{m}$ resolution step command. The velocity variation of feeding system is less than 0.6%. From these results, it is confirmed that the aerostatic guideway driven by the coreless linear motion is very useful for the ultra precision machine tools.

  • PDF

직류전기철도 시스템에 있어서의 변전소 송출전압에 따른 회생전력유효이용 (An Effective Utilization of Regenerative Power According to the Output Voltage of Substations in the DC Electric Railways)

  • Kim, Yang-Mo
    • 대한전기학회논문지
    • /
    • 제39권2호
    • /
    • pp.149-156
    • /
    • 1990
  • In DC electric railway systems, the feeding currrnt is not permitted to flow backward in almost all the substations and the pantograph voltages at the regenerating cars rise extremely by the voltage drop of the resistance of the feeder line. In order to prevent the overrise of the pantograph voltage in power regenerating cars, the squeezing circuits for the regenerative current are equipped and this leads to double losses, which are an extra worn-out of the brake-shoes and an ineffective use of regenerative power. In this study, the insertion of resistors in the feeder line system is proposed as a possible method for the effective utilization of the regenerative power in the electric railways. Also it is investigated how the output voltages of substations affect the effective use of regenertive capability. The investigation results show that the energy savings and the reduction of the worn-out of the brake-shoe can be achieved at the same time by the insertion of resistors in the feeder line system.

  • PDF

인천 국제공항청사 경전철 도입에 따른 고조파 영향 분석 (Power Quality Evaluation of An IAT(Intra Airport Transit) System in Incheon International Airport)

  • 이준경;이승혁;김진오;정현수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.238-240
    • /
    • 2005
  • This paper presents harmonic evaluation of an IAT(Intra Airport Transit) system in Incheon International Airport. It will be used electric vehicles with 80 kW per car that are produced Mitsubishi Heavy Industries Ltd, and one car is constructed with SIV(Static Inverter), VVVF controller and two induction motor. The operated vehicles in the IAT system are rapidly changing DC load and at a feeding substation, 3-phase electric power is transferred to DC 750 V by rectifier. Since, vehicles are also changing continuously, the voltages for the load fluctuate in the IAT system, and moreover, the fluctuating voltages generate high-order har -monies. This means that there is the difficulty in maintaining power quality in KEPCO systems' side. Therefore, the power quality of the IAT system in Incheon International Airport is evaluated using PSCAD/EMTDC simulator in the paper The THD(Total Harmonic Distortion) of voltages and TDD(Total Demand Distortion) of currents, indices are calculated for the IAT system using the results of PSCAD/EMTDC dynamic simulation.

  • PDF

B-PON 시스템을 위한 전원 공급망의 고전압 구현기술 (HIGH VOLTAGE DC POWER FEEDING TECHNOLOGY IN B-PON SYSTEM)

  • 이진영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.226-227
    • /
    • 2001
  • 일반거주지역의 초고속 광가입자망 구축을 위해 B-PON(Broadband Passive optical network)시스템과 이를 위한 급전방안으로 공유급전이 고려되고 있다. 한곳의 Power-Node가 최대 32개의 ONU에 전력을 공급하기 위해서는 고 전위의 구동 source가 필요하게 된다. 고압실현을 위하여 검토되는 회로는 범용으로 사용되는 linear 방식보다는 SMPS(Switching Mode Power Supply)방식의 소형경량화의 회로를 채택하며, 고 용량화에 수반되는 역률 문제를 보상하고, 고효율을 실현하여 전체시스템의 전력밀도의 극대화를 이루었다.

  • PDF