• 제목/요약/키워드: DC feeder cable

검색결과 4건 처리시간 0.016초

Investigation of On-line Monitoring Method on 1500 V Direct Current Cable of Subway

  • Shen, Xiaojun;Jiang, Xiuchen;Yi, Zeng
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.247-251
    • /
    • 2006
  • The traction DC feeder cable is one of the key devices for the safety operation of subway system, but for low voltage DC feeder cable (<3000 V) for subway, little attention has been paid by investigators on its online monitoring technology. With an introduction of cable laying and operation environment for the cable, this paper investigated the on-line monitoring technology of 1500 V DC feeder cable of subway. Firstly, in the text, the fault model of 1500 V DC cable was proposed based on the analysis of the fault type of the DC feeder cable, and then put forward synthetically on-line monitoring discharge signal and DC leakage current signal to assess DC feeder cable insulating state. The results of laboratory experiment prove that the proposed methods are feasible and can be implemented on-line monitor on DC feeder cable of subway.

DC 급전케이블 지락사고 보호방안에 관한 연구 (The study on the prevention of DC feeder line cable grounding fault)

  • 박지수;송중호;박정욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.202-207
    • /
    • 2008
  • This study provides review and improvement plans for the possible problems caused when the CV cable is used as a positive feeder line which supplies power from the DC HSCB (high-speed circuit breaker) to the catenariesin Seoul Metro which is using direct-current feeder method. In detail, this study contributes to stabilizing the power line by triggering a protective device by instantly detecting potential rise which happens when grounding fault occurs in non-grounding type CV cable shield.

  • PDF

금속블록 채널이 있는 유도형 전력선통신에 관한 연구 (A Study on Inductive Power Line Communication with Metal Block Channel)

  • 손경락;김현식
    • 전기전자학회논문지
    • /
    • 제25권1호
    • /
    • pp.95-100
    • /
    • 2021
  • 조선소에서 선체 블록과 용접 피더의 위치를 알면 작업자의 위치 정보를 쉽게 얻을 수 있다. 이 데이터는 작업장 안전 모니터링 시스템 구축에 매우 유용하다. 그러나 선체 구조와 용접 공정의 특수성 때문에 작업장에 고정 통신망을 적용하기 어렵다. 본 연구에서는 전용 통신선을 대신할 수 있는 유도 전력선 통신을 선체블록과 같은 금속매체에 적용하는 기술을 검토하였다. 용접기의 전원 케이블에 설치할 유도 결합기로 페라이트 코어를 사용하였고, 금속 블록의 지지대에 체결할 결합기로 나노 결정질 코어를 적용하였다. 제안된 커플러는 COMSOL AC/DC 모듈로 3차원 모델링 하였고 동작 원리를 시각화하기 위하여 유한 요소 해석을 수행하였다. 알루미늄 프로파일을 사용한 금속블록 통신 성능 테스트에서 용접 전극의 블록 접촉으로 통신 채널이 형성되었을 때 대역폭은 6 Mbps 이상 유지되었다.

지하철 전력계통의 고조파 영향 분석 및 그 대책에 관한 연구 (Analysis of Harmonic Effects on Substation Power System and its Countermeasure)

  • 송진호;황유모
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권4호
    • /
    • pp.210-220
    • /
    • 2002
  • We analysised the effect of harmonics on electric machines of substation power system barred on quantitatively measured harmonics and proposed the methods for prevention of harmonics through checking on transformer, rectifier and cable's capacities against harmonics with reference to KEPCO's electricity service standard. In order to analysis harmoninics of silicon rectifier that is power source in DC substation, computer simulations for a substation with TR of high voltage distribution switchboard are performed. Simulation results show that the total harmonic distortion factor becomes smaller for TR primary and receiving points in order rather than silicon rectifier which is harmonic generation source so that the harmonics generated frets each rectifier are outflowed to power supply and high voltage distribution switchboard The result of higher distortion factors of voltage and current for rectifier with 100% load than those with 50 % and 30% indicates that the waveform of voltage and current for the real substation power system at the office-going and the closing hours with heavy loads might be more distorted. As proposed methods for harmonic reduction, the conventional 6 pulse-type for substation is required to be replaced by 12 pulse-type for reduction of 5th and 7th harmonics. The active filter rather than the passive filter is more effective due to severe variance of rectifier loads, but the high cost is price to be paid. In view of installation area and costs, the use of 12 pulse-type transformer is desirable and then the parallel transformer and the rectifier within the substation must be replaced at the same time. Other substations with parallel feeder can use 6 pulse-type transformer.