• Title/Summary/Keyword: DC Sensitivity

Search Result 220, Processing Time 0.023 seconds

Magnetoresistive of (NiFe/CoFe)/Cu/CoFe Spin-Valvec ((NiFe/CoFe)/Cu/CoFe Spin-Valve 박막의 자기저항 특성)

  • 오미영;이선영;이정미;김미양;이장로
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.5
    • /
    • pp.265-273
    • /
    • 1997
  • The MR ratios and the exchange biasing field and interlayer coupling field were investigated in $Ni_{91}Fe_{19}/Co_{90}Fe_{10}/Cu/Co_{90}Fe_{10}/NiO$ spin-valve sandwiches grown on antiferromagnetic NiO films as a function of the NiO thickness, the thickness of Cu and pinning layer $Co_{90}Fe_{10}$. The spin-valve sandwiches were deposited on the Corning glass 7059 by means of the 3-gun dc and 1-gun rf magnetron sputtering at a 5 mtorrpartial Ar pressure and room temperature. The deposition field was 50 Oe. The MR curve was measured by the four-terminal method with applied magnetic soft bilayer [NiFe/CoFe] (90$\AA$) decreased dramatically to less than 10 Oe when the NiFe/CoFe bilayer used an NiFe bilayer thicker that 20$\AA$. So NiFe layer improved the softmagnetic properties in the NiFe/CoFe bilayer. The GMR ratio and the magnetic field sensitivity of the spin-valve film $Ni_{91}Fe_{19}(40{\AA})/Co_{90}Fe_{10}(50{\AA}) /Cu(30{\AA})/Co_{90}Fe_{10}(35{\AA})/NiO(800{\AA})$ was 6.3% and about 0.5 (%/Oe), respectively. The MR ratio had 5.3% below an annealing temperature of 20$0^{\circ}C$ which slowly decreased to 3% above 30$0^{\circ}C$. The large blocking temperature of the spin-valve film was taken (as being) due to the good stability of the NiO films. Thus, the spin-valve films with a free NiFe/CoFe layer clearly had a high large GMR output and showed a effective magnetic field sensitivity for a suitable spin-valve head material.

  • PDF

DC Resistivity method to image the underground structure beneath river or lake bottom (하저 지반특성 규명을 위한 전기비저항 탐사)

  • Kim Jung-Ho;Yi Myeong-Jong;Song Yoonho;Cho Seong-Jun;Lee Seong-Kon;Son Jeongsul
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.139-162
    • /
    • 2002
  • Since weak zones or geological lineaments are likely to be eroded, weak zones may develop beneath rivers, and a careful evaluation of ground condition is important to construct structures passing through a river. Dc resistivity surveys, however, have seldomly applied to the investigation of water-covered area, possibly because of difficulties in data aquisition and interpretation. The data aquisition having high quality may be the most important factor, and is more difficult than that in land survey, due to the water layer overlying the underground structure to be imaged. Through the numerical modeling and the analysis of case histories, we studied the method of resistivity survey at the water-covered area, starting from the characteristics of measured data, via data acquisition method, to the interpretation method. We unfolded our discussion according to the installed locations of electrodes, ie., floating them on the water surface, and installing at the water bottom, since the methods of data acquisition and interpretation vary depending on the electrode location. Through this study, we could confirm that the dc resistivity method can provide the fairly reasonable subsurface images. It was also shown that installing electrodes at the water bottom can give the subsurface image with much higher resolution than floating them on the water surface. Since the data acquired at the water-covered area have much lower sensitivity to the underground structure than those at the land, and can be contaminated by the higher noise, such as streaming potential, it would be very important to select the acquisition method and electrode array being able to provide the higher signal-to-noise ratio data as well as the high resolving power. The method installing electrodes at the water bottom is suitable to the detailed survey because of much higher resolving power, whereas the method floating them, especially streamer dc resistivity survey, is to the reconnaissance survey owing of very high speed of field work.

  • PDF

Design and Fabrication of a Field Mill for Ground-Level Electric Field Measurement (대지전계 측정을 위한 필드밀의 설계 및 제작)

  • Kil, Gyung-Suk;Song, Jae-Yong;Kim, Il-Kwon;Kwon, Jang-Woo;Ahn, Chang-Hwan;Lee, Young-Keun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.52-59
    • /
    • 2007
  • A field mill capable of measuring the magnitude and polarity of electric fields at the ground level was studied to apply to a lightning warning system as a sensor. We designed and fabricated a planar-shutter type field mill with a rotating-vanes. A calibration of the field mill was performed in a vertically symmetrical arrangement which consists of two equal size parallel round plates to form a homogeneous electrical fields. The sensitivity of the field mill was adjusted at 0.5[V/kV/m], and this covers a ranges from 200[V/m] to 20[kV/m]. After the calibration experiment, the field mill was installed on the roof of a building to measure the changes of electric field intensity caused by thunderclouds. During the period from July 1. 2006 to July 15. 2006, the electric field intensity was recorded a ranges of $+2[kV/m]{\sim}-6[kV/m]$ depending on generation, extinction and movement of thunderclouds. From the actual test on the ground it is confirmed that the field mill has a good performance necessary for the measurement of DC electric fields.

Analysis and Mechanistic Investigation of Redox Process of 2-Amino-1-cyclopentene-1-dithiocarboxylate by Adsorptive Stripping Voltammetry on Glassy Carbon Electrode (Glassy Carbon 전극에서의 벗김 전압-전류법을 이용한 2-Amino-1-cyclopentene-1-dithiocarboxylate 의 분석과 전극 반응 메카니즘의 연구)

  • Yoon-Bo Shim;Duk-Soo Park;Sung-Nak Choi;Mi-Sook Won
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.1
    • /
    • pp.37-47
    • /
    • 1988
  • The electrochemical behavior of 2-Amino-1-cyclopentene-1-dithiocarboxylate (acdc) was investigated by the use of polarography, cyclic voltammetry and cathodic stripping voltammetry at glassy carbon electrode. In this study, it was found that the dimer of the acdc was deposited on the glassy carbon electrode via one-electron oxidation process at +0.25V vs. SCE. The ring formation between two dithio group occurs along with the elimination of one sulfur atom. The elimination of sulfur atom occurs via two electron oxidation process at +0.8V vs. SCE. The most sensitive cathodic stripping peak due to the formation of the dimer was observed at -0.85V vs. SCE. The peak relationship between current and concentration was fairly linear in the range of 3${\times}10^{-5}{\sim}1.0{\times}10^{-6}$M. The preconcentration procedure enhanced the sensitivity about 100 times for the analysis of acdc using diffusion current. Detection limit was found to be $2.5{\times}10^{-7}$M and relative standard deviation was ${\pm}$4.1 % at $5.0{\times}10^{-6}$M DC polarography.

  • PDF

Doppler Radar System for Long Range Detection of Respiration and Heart Rate (원거리에서 측정 가능한 호흡 및 심박 수 측정을 위한 도플러 레이더 시스템)

  • Lee, Jee-Hoon;Kim, Ki-Beom;Park, Seong-Ook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.4
    • /
    • pp.418-425
    • /
    • 2014
  • This paper presents a Ku-Band Doppler Radar System to measure respiration and heart rate. It was measured by using simultaneous radar and ECG(Electrocardiogram). Arctangent demodulation without dc offset compensation can be applied to transmitted I/Q(In-phase & Quadrature-phase) signal in order to improve the RMSE(Root Mean Square Error) about 50 %. The power leaked to receiving antenna from the transmitting antenna is always generated because of continuously opening the transceiver of CW(Continuous Wave) Doppler radar. As the output power increase, leakage power has an effect on the SNR(Signal-to-Noise Ratio) of the system. Therefore, in this paper, leakage cancellation technique that adds the signal having the opposite phase of the leakage power to the leakage power was implemented in order to minimize the decline of receiver sensitivity. By applying the leakage cancellation techniques described above, it is possible to measure the heart rate and respiration of the human at a distance of up to 35 m. the heart rate of the measured data at a distance of 35 m accords with the heart rate extracted from the ECG data.

An efficient 2.5D inversion of loop-loop electromagnetic data (루프-루프 전자탐사자료의 효과적인 2.5차원 역산)

  • Song, Yoon-Ho;Kim, Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.1
    • /
    • pp.68-77
    • /
    • 2008
  • We have developed an inversion algorithm for loop-loop electromagnetic (EM) data, based on the localised non-linear or extended Born approximation to the solution of the 2.5D integral equation describing an EM scattering problem. Source and receiver configuration may be horizontal co-planar (HCP) or vertical co-planar (VCP). Both multi-frequency and multi-separation data can be incorporated. Our inversion code runs on a PC platform without heavy computational load. For the sake of stable and high-resolution performance of the inversion, we implemented an algorithm determining an optimum spatially varying Lagrangian multiplier as a function of sensitivity distribution, through parameter resolution matrix and Backus-Gilbert spread function analysis. Considering that the different source-receiver orientation characteristics cause inconsistent sensitivities to the resistivity structure in simultaneous inversion of HCP and VCP data, which affects the stability and resolution of the inversion result, we adapted a weighting scheme based on the variances of misfits between the measured and calculated datasets. The accuracy of the modelling code that we have developed has been proven over the frequency, conductivity, and geometric ranges typically used in a loop-loop EM system through comparison with 2.5D finite-element modelling results. We first applied the inversion to synthetic data, from a model with resistive as well as conductive inhomogeneities embedded in a homogeneous half-space, to validate its performance. Applying the inversion to field data and comparing the result with that of dc resistivity data, we conclude that the newly developed algorithm provides a reasonable image of the subsurface.

Fiber-optic Mach-Zehnder Interferometer for the Detection of Small AC Magnetic Field (미소 교류 자기장 측정을 위한 Mach-Zehnder 광섬유 간섭계 자기센서 특성분석)

  • 김대연;안준태;공홍진;김병윤
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.139-148
    • /
    • 1991
  • A fiber-optic magnetic sensor system for the detection of small ac magnetic field(200Hz-2 kHz) was constructed. Magnetic field sensing part was fabricated by bonding a section of optical fiber to amorphous metallic glass(2605SC) having large magnetostriction effect. And with the directional coupler, all fiber type Mach-Zehnder interferometer was constructed to measure the variation of the external magnetic field by translating it into the optical phase shift in the interferometer. The signal fading problem of the interferometer, which is due to random phase drifts originated from the environment, i.e., temperature fluctuation, vibrations, etc., was elliminated by feedback phase compensation. This allows the sensitivity to be maintained at the maximum by keeping the interferometer in quadrature phase condition. The frequency response of metallic glass was found to be nearly flat in the range of 90 Hz-2 kHz and dc bias field for the maximum ac response was 3.5 Oe. The interferometer output showed good linearity over the range $\pm$0.5 Oe. For 1 kHz ac magnetic field the scale factor S and the minimum detectable magnetic field were measured to be 8.0 rad/Oe and $3X10^{-6} Oe/\sqrt{Hz}$at 1 Hz detection bandwidth respectively.

  • PDF

The Effect of Transcranial Direct Current Stimulation over the Primary Somatosensory Cortex in Patients with Chronic Stroke on Somatosensory and Upper Limb Function for Improving Life Care (만성 뇌졸중 환자를 대상으로 한 일차 체성 감각 피질을 자극한 경두개 직류 전류 자극이 라이프 케어 증진을 위한 체성감각과 상지기능에 미치는 영향)

  • Kim, Sun-Ho
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.6
    • /
    • pp.269-277
    • /
    • 2020
  • The purpose of this study is to investigate the recovery of sensation and the restoration of upper limb function according to transcranial direct current stimulation over the primary somatosensory cortex in patients with chronic stroke with sensory deficit. 20 patients with chronic stroke divided into 10 experimental groups and 10 control groups. Patients received transcranial direct current stimulations over the primary somatosensory cortex on the side of the stroke lesion, and The control group applied sham tDCS to the same location. Intervention was conducted 5 times a week, 20 minutes per session for a total of 2 weeks. Assessment was performed using the Erasmus MC modifications to the Nottingham Sensory Assessment(EmNSA), Semmes-Weinstein monofilament examination(SWME) for somatosensory, and Fugle-Meyer Assessment(FMA), Motor Activity Log(MAL), and accelerometer for upper extremity function. Assessment was conducted before and after the intervention. As a result of the study, the experimental group showed a significant improvement in the overall tactile sense, proprioception, cortical sense, and perception sensitivity than the control group, and showed a statistically significant difference in the usage amount of the upper limb. Based on the results of this study, it is thought that the possibility of effective clinical application of transcranial direct current stimulation for recovery of somatosensory and upper extremity function is thought to be increased.

Studies on the Mechanism of the Ameliorative Activities on Hyperglycemia and Dyslipidemia of Red Ginseng Herbal Acupuncture in C57BL/KsJ db/db Mice (홍삼약침(藥鍼)이 제2형 당뇨병 동물모델의 항고혈당(抗高血糖)및 항고지질(抗高脂質) 기전(機轉)에 미치는 영향(影響))

  • Kim, Jong-Deok;Kim, Jong-In;Koh, Hyung-Kyun;Lee, Yun-Ho;Kang, Sung-Keel
    • Journal of Acupuncture Research
    • /
    • v.25 no.2
    • /
    • pp.11-26
    • /
    • 2008
  • 목적 : 홍삼약침(藥鍼)이 고혈당 및 지질대사장애에 미치는 개선효과와 그 기전을 조사하고자 한다. 방법 : 홍삼약침(藥鍼)의 anti-diabetic 활성과 그 기전을 C57BL/KsJ db/db mice를 이용하여 관찰하였다. 실험 동물은 대조군(DC), 홍삼약침(藥鍼)군(RGL, RGH) 및 양성대조군(MET, GPZ, PIO)의 6군으로 나누었다. 홍삼약침(藥鍼)군은 $0.2m{\ell}$의 홍삼약침멸(藥鍼滅)을 각각 100mg/kg(RGL) 및 200mg/kg(RGH)씩 인체의 간유(肝兪)($BL_{18}$)에 상응하는 혈위에 1일 1회 10주간 좌우 혈을 번갈아가며 약침 시술하였다. 양성대조군은 metformin 300mg/kg(MET), glipizide 15mg/kg(GPZ) 및 pioglitazone 30mg/kg(PIO)을 각각 1일 1회 10주간 경구투여 하였다. 체중과 혈당은 매주 측정하였다. 실험 10주 후에는 혈액채취로 혈중 glucose, 당화혈색소(HbAlc), insulin, 중성지방(TG), adiponectin, leptin, non-esterified fatty acid(NEFA)를 측정 하였고, 간 조직을 채취하여 조직학적 검사 및 gene expression 분석을 시행하였다. 결과 : 홍삼약침(藥鍼)(RGL, RGH)은 10주 동안 C57BL/KsJ db/db mice의 체중을 증가시키는 부작용은 나타나지 않았다. 홍삼약침(藥鍼)군(RGL, RGH)의 사료섭취량은 대조군과 비슷하였으나 음수량은 증가하였다. 홍삼약침(藥鍼)(RGL, RGH)은 대조군에 비하여 각각 19.8% 및 18.3% 혈당을 낮추었고, 홍삼약침(藥鍼)(RGL)은 insulin resistance를 27.7% 감소시켰으며, 경구내당능 검사의 혈중 glucose에서는 대조군에 비해 홍삼약침(藥鍼)군(RGL, RGH)과 양성대조군(MET, GPZ, PIO)에서 각각 19.8%, 18.3%, 67.7%, 52.3% 및 56.9% 감소시켰다. 당화혈색소(HbAlc)는 홍삼약침(藥鍼)(RGL, RGH), MET, GPZ 및 PIO군에서 대조군에 비하여 각각 11.0%, 6.4%, 18.9%, 16.1% 및 27.9% 감소시켰으며, 혈중 glucose감소와 유사한 경향을 나타내었다. 홍삼약침(藥鍼)(RGL)은 대조군에 비해 TG와 NEFA를 각각 18.8% 및 16.8% 감소시켰고, adiponectin과 leptin을 각각 20.6% 및 12.1% 증가시켰다. 홍삼약침(藥鍼)(RGL, RGH)은 중성지방의 침착으로 인한 간의 질량비 증가를 억제하지 못하였으나, 지방구를 감소시겼음을 관찰할 수 있었다. Microarray 분석에서는 홍삼약침(藥鍼)(RGL, RGH)이 간에서 glycolysis, gluconeogenesis 및 fatty acid beta-oxidation과 관련된 유전자 발현에 영향을 미치는 것으로 나타나 양성대조군 metformin과 유사한 기전을 나타내었다. 요약 : 홍삼약침(藥鍼)은 T2DM동물모델(C57BL/KsJ db/db mice)에서 항당뇨 및 지질대사 개선활성이 있었다. 홍삼약침(藥鍼)은 C57BL/KsJ db/db mice의 간조직에서 lipogenesis억제 및 fatty acid beta-oxidation활성을 통해 혈당 이용을 높이고, insulin sensitivity를 향상시켰다. 또한 유전자 발현분석을 통해 그 기전이 metformin과 유사함을 확인할 수 있었으므로 향후 홍삼약침(藥鍼)의 새로운 약침 기술 개발 근거가 될 수 있을 것으로 사료된다.

  • PDF

Development of Prevotella nigrescens ATCC $33563^T$-Specific PCR Primers (Prevotella nigrescens ATCC $33563^T$ 균주-특이 중합효소연쇄반응 프라이머 개발)

  • Song, Soo-Keun;Yoo, So-Young;Kim, Mi-Kwang;Kim, Hwa-Sook;Lim, Sun-A;Kim, Do-Kyung;Park, Jae-Yoon;Kook, Joong-Ki
    • Korean Journal of Microbiology
    • /
    • v.44 no.3
    • /
    • pp.212-220
    • /
    • 2008
  • A Pn10 DNA probe was introduced as a Prevotella nigrescens ATCC $33563^T$-specific DNA probe. In that study, the specificity of the Pn10 was tested with only type or reference strains of 5 oral bacterial species. The purpose of this study is to evaluate the specificity of the Pn10 using the wild type strains of P. nigrescens and is to develop the P. nigrescens ATCC $33563^T$-specific PCR primers based on the nucleotide sequence of the Pn10. The specificity of the Pn10 DNA probe was determined by Southern blot analysis. The nucleotide sequence of Pn10 DNA probes was determined by chain termination method. The PCR primers were designed based on the nucleotide sequence of cloned DNA fragment. The data showed that Pn10 DNA probe were hybridized with the genomic DNAs from P. nigrescens ATCC $33563^T$ and KB6. The Pn10 homologous region, KB6-Pn10, of P. nigrescens KB6 was cloned by PCR and sequenced. The Pn10 and KB6-Pn10 DNA fragments were consisted of 1,875 bp and 1,873 bp, respectively. The percent identity of the two was 98.8% and the divergence of them was 0.6%. The two primer sets (Pn10-F-AC/ Pn10-R-AC and Pn10-F-A/ Pn10-R-A), designed base on the nucleotide sequences of Pn10 DNA probe, were specific to the P. nigrescens ATCC $33563^T$. The two PCR primer sets could detect as little as 4 pg of genomic DNA of P. nigrescens ATCC $33563^T$. These results indicate that the two PCR primer sets have proven useful for the identification of P. nigrescens ATCC $33563^T$, especially with regard to the maintenance of the strain.