• Title/Summary/Keyword: DC Relay

Search Result 87, Processing Time 0.036 seconds

A Study on Detection of High Impedance Fault in Low Voltage DC Distribution System using Filter based on Mathematical Morphology (수학적 형태학 기반의 필터를 이용한 저압직류 배전계통의 고저항 지락고장 검출에 관한 연구)

  • Oh, Yun-Sik;Noh, Chul-Ho;Kim, Doo-Ung;Gwon, Gi-Hyeon;Han, Joon;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.89-95
    • /
    • 2015
  • As a solution of improving the energy efficiency in power system, Low Voltage DC (LVDC) distribution systems different from conventional ones have been constantly researched. As in conventional AC distribution system, LVDC distribution system can suffer from High Impedance Fault (HIF) which may cause a failure of protective relay due to relatively low change in magnitude of fault current. In order to solve the problem, a scheme for detecting HIFs is presented in this paper. Closing Opening Difference Operation (CODO) based on Mathematical Morphology (MM), one of the MM-based filters, is utilized to make fault signals discriminable. To verify performance of the scheme, a simple LVDC distribution system is modeled by using ElectroMagnetic Transient Program (EMTP) software. Computer simulations according to various conditions are performed and comparison studies with a scheme using Wavelet Transform (WT) in an aspect of simulation time are also conducted.

Current Limiting Characteristics of a Resistive SFCL for a Single-line-to-ground Fault in the 22.9 kV System (1선 지락사고에 대한 배전급 저항형 초전도 한류기의 전류제한특성)

  • 최효상;황시돌;현옥배
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.6
    • /
    • pp.505-510
    • /
    • 2001
  • We simulated the current limiting characteristics of a resistive superconducting fault current limiter (SFCL) for a single line-to-ground fault in the 22.9 kV system. The transient current during the fault increased to 6.33 kA, 5.80 kA and 3.71 kA without SFCL at the fault angles 0$^{\circ}$, 45$^{\circ}$ and 90$^{\circ}$, respectively, a resistive SFCL limited effectively the fault current to 2.27 kA in a half cycle without any DC components. The maximum quench resistance of an SFCL, 16Ω was suggested to be appropriate to limit the fault current in the 22.9 kV distribution system, considering the operating cooperation of a protective relay and the current limiting performance of an SFCL.

  • PDF

Establishment of 345kV transformer protective relay dynamic performance test environment (345kV 변압기 보호 계전기 동특성 성능검증 기반 구축)

  • Jang, B.T.;Choi, C.Y.;Kim, J.Y.;Lee, C.H.;Yang, G.J.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.101-102
    • /
    • 2006
  • 345kV 변전소는 국내 전력계통의 근간으로서 고장 시계통 안정도에 미치는 영향이 크기 때문에 고장 제거가 착신하고 신속해야 한다. 따라서 345kV 변전소의 보호 장치들은 CT, PT, 차단기(trip coil), 보호계전기, DC전원 등이 모두 2계열화되어 있으며 보호 계전기는 각 계열마다 주보호와 후비보호가 따로 구비되어 있다. 본 논문에서는 34skv 변압기 보호용 보호계전기에 내장된 계전요소들의 유기적인 성능 검증을 할 수 있는 동특성 시험에 관한 기반 구축 과정 및 결과에 대해서 기술한다.

  • PDF

The Modelling of digital filter of CT including saturation including Saturation phenomena (포화를 고려한 CT의 디지탈 필터로의 모델링)

  • Kang, Yong-Cheol;Kang, Sang-Hee;Kim, Nam-Ho;Kim, Il-Dong;Yoon, Man-Cheol;Park, Jong-Geun
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.55-58
    • /
    • 1992
  • Due to the fault signal containing high and/or slowly decaying dc off-set component, saturation of current transformers cause errors in reproducing secondary current and therefore, secondary current is distorted, which cause relay to maloperate. In this paper, a new method which determines whether current transfomer is saturated is proposed. By designing digital filter of current transfomer, although secondary is distorted, exact secondary current can be reproduced.

  • PDF

Protective Relay Malfunction Of 345kV Underground Transmission Line Due to CT Saturation (CT포화에 의한 345kV 지중선로 보호계전기 오동작 사례)

  • Jeon, Myeong-Ryeol;Lee, Se-Il;Kim, Joung-Woon;Kim, Ki-Il
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.25-26
    • /
    • 2008
  • A, B 변전소간에 345kV 지중선로 4회선으로 Loop 운전 중 1개의 지중선로에 절연파괴 고장이 발생하였으며, 이때 4개의 지중송전선로가 모두 운전정지 되는 고장이 발생하였다. 고장이 발생한 선로는 정상적으로 보호계전기가 동작하였으나, 그 외 다른 선로의 보호계전기가 오동작하여 원인규명시험을 한 결과 외부고장시 CT 포화로 인해 보호계전기가 자단고장으로 인식하여 동작된 것으로 분석되었다. 본 논문에서는 CT 포화와 관련하여 DC성분, Surge, 2차 부담 등 여러가지 조건에 대하여 고찰함으로서 향후 전력계통의 다양한 고장에 대비하는데 도움이 되기를 기대한다.

  • PDF

Fault Locating Improvement of Transmission Line (송전선로의 고장점 표정 개선)

  • Park, Yu-Yeong;Lee, Jae-Yun;Seok, Kwang-Ho;Kim, Yoon Sang;Park, Chul-Won
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.547-548
    • /
    • 2015
  • In order to reduce error of the distance relay, we propose an improved fault locating scheme using DC offset removal filter. We were modeled 154 kV transmission system using ATP software in order to demonstrate the usefulness of proposed scheme, and applied to the proposed scheme using collected voltage signal and current signal by line-to-ground fault.

  • PDF

The Interference Measurement Analysis between 3.412 GHz Band Broadcasting System and UWB Wireless Communication System

  • Song Hong-Jong;Kim Dong-Ku
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.1
    • /
    • pp.76-81
    • /
    • 2006
  • Ultra wideband(UWB) technologies have been developed to exploit a new spectrum resource in substances and to realize ultra-high-speed communication, high precision geo-location, and other applications. The energy of UWB signal is extremely spread from near DC to a few GHz. This means that the interference between conventional narrowband systems and UWB systems is inevitable. However, the interference effects had not previously been studied from UWB wireless systems to conventional wireless systems sharing the frequency bands such as Broadcasting system. This paper experimentally evaluates the interference from two kinds of UWB sources, namely a orthogonal frequency division Multiplex UWB source and an impulse radio UWB source, to a Broadcasting transmission system. The receive power degradations of broadcasting system are presented. From these experimental results, we show that in all practical cases UWB system can coexist 35 m distance in-band broadcasting network.

The Verification Method of Digital Protective Algorithm Using EMTDC (EMTDC를 이용한 Digital 보호 알고리즘 검증방법)

  • Lee, J.G.;An, B.S.;Jung, B.T.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.674-676
    • /
    • 1996
  • In this paper, we suggested the verification method of protective algorithms using EMTDC(Electro-Magnetic Transient DC). In other to verify protective algorithms using EMTDC, we first had to make a user defined component and then applied it to a simple power system with parallel line. By means of this method, We reduced the much time and effort to develop or improve the protective algorithm of digital protective relay. For the future, we apply this method to IDPACS(Integrated Digital Protection and Control System) and intend to implement more reliable digital protective relays.

  • PDF

소형위성 ETB에서의 전력계 기능시험

  • 윤영수;박종오;최종연;권재욱;안재철;조승원;김영윤
    • Bulletin of the Korean Space Science Society
    • /
    • 2003.10a
    • /
    • pp.91-91
    • /
    • 2003
  • 위성을 발사하기 전까지는 지상에서 EGSE(Electrical Ground Support Equipment)를 이용하여 충분한 시스템 단위의 위성체 기능 시험을 수행한다. KOMPSAT-2(Korea Multi-Purpose Satellite - 2)와 같은 소형 위성의 서브시스템 각각이 요구사항에서 제시하는 규격을 만족하는지 여부를 점검하는 단계에서 전력계 관련 서브시스템의 기능 시험도 EPS(Electrical Power Subsystem) Test Plan에 의해 순차적으로 수행한다. KOMPSAT-2 ETB(Engineering Test Bed)에서의 전력계 시험은 먼저 Test Fuse Modules Check를 수행하였다. 퓨즈 모듈은 PCU(Power Control Unit) 상에 설치되어 있는 장치로써 퓨즈 모듈의 입력과 출력 사이에 도통성 및 다른 출력과의 절연성을 검증한다. 다음으로 EGSE 중 PMTS(Power Monitor Test Set)와 PCU와의 직렬 인터페이스를 점검하는 PCU Interface Check를 수행하였다 시험절차서에 따라 PCU가 가지는 릴레이 스위치에 대하여 명령어를 보내어 릴레이의 동작 상태 및 출력 전압 등을 점검한다. 다음 단계에서는 DC Integration을 수행하여 ETB 하니스 중 전원 관련 라인을 점검하였다 PCU는 모든 위성체 하드웨어에 전력을 공급하는 장비로써 과전력으로부터 하드웨어를 보호하기 위하여 하니스를 연결하기 전에 우선적으로 시험한다. 다음으로는 ECU(EPS Control Unit)가 각각에 해당하는 하드웨어에 명령어를 보내어 전력계 전체적인 동작 상태 검증하는 EPS Hardware Command & Telemetry Checkout을 수행하였다. ECU는 전력계의 모든 하드웨어를 제어하고 그 상태를 모니터링하는 기능을 한다. PCU와의 인터페이스를 통하여 전력의 제어 및 분배에 관련되는 특성을 제어 및 모니터하며 DDC(Deploy Device Controller)는 ECU로부터 명령어를 받아서 arm 및 safe 상태에 대한 텔리 메트리 데이터를 제공한다 그리고, SAR(Solar Array Regulator)는 ECU로부터 Bypass Relay 및 ARM Relay에 관한 명령어를 받아 수행되며 그에 따른 텔리 메트리 데이터를 제공한다. 마지막으로 EPS 소프트웨어를 검증하는 EPS Software Verification을 수행하였다 전력계 소프트웨어의 설계의 검증 부분은 현재 설계 제작된 전력계 .소프트웨어의 동작 특성 이 위성 의 전체 운용개념과 연계하여 전력계 소프트웨어가 전력계 및 위성체의 요구조건을 만족시키는지를 확인하는데 있다. 전력계 운용 소프트웨어는 배터리의 충ㆍ방전을 효율적으로 관리해 3년의 임무 기간동안 위성체에 전력을 공급할 수 있도록 설계되어 있다

  • PDF

A New Design of Power Folding Controller for Deterioration Detection (열화방지형 파워폴딩 제어기 설계에 관한 연구)

  • Kim, Ji-Hyeon;Lee, Dong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.3
    • /
    • pp.51-58
    • /
    • 2008
  • This paper is a study of a prevention of power folding controller's thermal degradation. Power folding technology has been applied for many fields such as side rear vision mirror of vehicles, windshield wiper, antenna, power window. These controllers have been comprised with traditional DC moors, Switching electronic devices, and relays. But this methods have a limitation to overcome such problems of product reliability, endurance, noise margins. Therefore on this paper, to detect the movement of motor, sensing motor brush noise on a load sensing part has been used and controlling a precise RC timing control minimizes the thermal deterioration of motor. And using MOS FETs as a electronic switching device increases life-time and liability of control circuit. After testing such circuit and control method, repetition of operating time, cut-off time, wide operation voltage, power noise margin ware increased over eleven-fold.