• 제목/요약/키워드: DC Electric Field

검색결과 286건 처리시간 0.034초

직류전동차용 피뢰기 진단기술 (Diagnostic Techniques of Lightning Arresters for DC Electric Traction Vehicles)

  • 길경석;송재용;김일권;문승보;신광철
    • 한국철도학회논문집
    • /
    • 제9권4호
    • /
    • pp.357-361
    • /
    • 2006
  • This paper dealt with the performance evaluation and the diagnostic techniques of lightning arresters for DC electric traction vehicle. Field Measurements on the protective operation of lightning arresters against surge currents were carried out on running vehicles to acquire the data necessary for the diagnosis. The frequency and the magnitude of surge events were analyzed. Surge currents of $1\sim3$ times were recorded in one running service route and their magnitudes were ranges of $150A\sim2kA$. Also, an acceleration experiment on a lightning arrester by the standard lightning impulse current of 8/20 us and 5 kA was performed to know the aging characteristics. After the surge current application of 3,000 times, the reference voltage decreased by 4.5 %, and the leakage current was below 10 uA at the continuous operating voltage and about 50 uA at the rated voltage. From the experimental results, we propose a decision level of leakage current for the arrester used in this paper and designed an arrester tester which analyzes arrester condition by the magnitude of leakage current.

전기탈수방법에 의한 하수 슬러지 탈수 특성 (Efficient Dewatering of the Sewage Sludge by Electrodewatering System)

  • 박찬정;이정언;안영철;신희수;이재근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.526-531
    • /
    • 2000
  • Application of electrodewatering (EDW) to mechanical dewatering system was studied to decrease water content in the sludge generated from waste water treatment process. Experiments realized the reduction of water content in the sewage sludge. EDW enhancing the conventional filtration by an electric field is an emerging technology with the potential to improve dewatering. In this study, a piston filter press was constructed, the digested sludges were dewatered by EDW under conditions of DC electric field and constant pressure in the piston filter press. Constant electric field from $0{\sim}120\;V/cm$ and constant pressure $98.1{\sim}392.4\;kPa$ were used. The results showed that as electric field was increased the dewatering rates increased and as pressure was increased the dewatering rates decreased. Also as polymer was added the dewatering rates increased. This experiments produced final sludge cake with water content of 60 wt% using EDW, compared with 80 wt% using pressure filtration alone.

  • PDF

권선 단선 고장 DC 모터의 진단 (Diagnosis for Winding Open Fault of DC Motor)

  • 양철오;표연준;김준영;박규남;송명현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2073-2074
    • /
    • 2011
  • In this study, an algorithm for diagnosis of dc motor with winding open fault is suggested. A dc motor used in this paper, is consisted of a permanent magnet field stator, double 16-turn series winding rotating armature with 12-slot, brush and 12-commutator, etc. A current signal of dc motor which has brushes and commutatorswas considered for fault diagnosis. By commutation, this current signal shows different wave form according to the fault condition of the motor. In this study, operation of the data was easily through simplification of the current signal by the signal processing. Computation method is presented reference value($C_{dv}$) for diagnosis of winding open fault and verified through experiments that can be diagnosed using the reference value($C_{dv}$).

  • PDF

AC/DC 하이브리드 선로의 전기환경특성 예측을 위한 축소모델 개발 (A Development of Reduced-scale Model to Predict of Environmental Characteristics of AC/DC Hybrid Overhead Transmission Line)

  • 최인혁;신구용;이동일;임재섭;김영홍;맹종호;주문노
    • 전기학회논문지
    • /
    • 제61권5호
    • /
    • pp.676-682
    • /
    • 2012
  • To review application of HVDC (High Voltage Direct Current) transmission line to HVAC T/L in operation, reduced-scale model was designed and manufactured. The arms of model were designed to change height and interval of conductors. Electrical environmental interferences were estimated by various configuration of AC 345kV and DC 250kV T/L. The interferences such as electric field intensity and ion current density were measured and converted reduced-scale factor to full-scaled. Additionally, effects between AC and DC T/L were studied.

코로나 방전에 대한 자계의 영향 (The effect of magnet fields on the corona discharge)

  • 박재윤;정장근;김익균
    • 조명전기설비학회논문지
    • /
    • 제15권3호
    • /
    • pp.51-56
    • /
    • 2001
  • 본 논문에서는 침대평판 전극구조를 구성하여 침전극에 직류 정 ·부 고전압을 인가한 경우 전계와 자계가 직각방향으로 형성되도록 하고 자계가 코로나 방전현상에 미치는 영향을 측정하고 분석하였다. 정의 고전압을 인가한 경우 자계인가에 의해 방전코로나 영역이 확장되고 이때 흐르는 코로나전류가 감소하였고, 절연파괴전압은 증가되었다. 그러나 부의 고전압을 인가한 경우는 방전코로나 영역이 오히려 축소되고 흐르는 전류가 증가되었으며 절연파괴전압은 감소되었다. 이는 전자계가 동시에 존재하는 영역에서 코로나방전에 의해 생성된 전하들의 로렌쯔력에 의한 싸이크로트론 운동 때문인 것으로 생각된다.

  • PDF

슈퍼 커패시터를 이용한 직류철도 회생에너지 저장장치 (DC Traction Regenerative Energy Storage Devices using Super-capacitor)

  • 김종윤;정두용;장수진;이병국;원충연
    • 전력전자학회논문지
    • /
    • 제13권4호
    • /
    • pp.247-256
    • /
    • 2008
  • 직류철도의 회생제동 시 발생되는 회생에너지는 급전선로의 직류가선전압의 상승에 의해 시스템의 오동작이나 차량 정류기의 파손, 또는 급전 시스템의 전력변환 장치의 고장을 일으키는 원인이 될 수 있다. 슈퍼 커패시터를 이용한 회생에너지 저장장치는 직류가선전압을 안정화 하게하는 방법이다. 본 논문에서는 슈퍼 커패시터 뱅크를 이용하여 직류철도 시스템의 에너지 저장장치를 구현하였고, 지하철 2호선 N역과 S역의 실측값을 이용하여 가선전압이 전동차에 의한 회생에너지 발생에 따른 동작 특성과 슈퍼 커패시터의 충 방전 특성을 확인하였다. 본 논문을 통하여 직류철도 시스템에 설치된 회생에너지 저장시스템용 슈퍼 커패시터 뱅크의 동작 특성을 알 수 있고, 향 후 직류철도 모든 변전소의 직류 가선전압 실측 데이터를 이용한다면, 특정 직류철도 운행 구간에 대한 회생에너지 저장장치의 운전특성과 슈퍼커패시터의 용량 및 수명 예측으로 가격을 절감 할 수 있고 전체 시스템의 안정도 와 신뢰성을 향상시킬 수 있다.

직류전기장이 인가된 층류제트화염에서 물질 -열 확산과 부력에 의한 진동비교에 관한 연구 (A Comparative Study Between Diffusive-thermal and Buoyancy-driven Self-excitations in Laminar Free Jet Flames with Applied DC Electric Fields)

  • 한종규;윤성환;박정;권오붕;김태형;박종호
    • 한국연소학회지
    • /
    • 제17권1호
    • /
    • pp.37-47
    • /
    • 2012
  • Experimental study on comparison of diffusive-thermal self-excitation with buoyancy-driven one due to accumulation of partially premixed, preheated mixture in front of edge flame was conducted in horizontally and vertically injected laminar free-jet flames with an applied DC electric field of -10 kV. The application of horizontal injection method with the DC electric field to jet flames was experimentally designed to suppress heat-loss-induced self-excitation and thereby to highlight the definite difference between both diffusive-thermal and buoyancy-driven self-excitations with the same order of O(1.0 Hz), in that diffusive-thermal self-excitation has not been so far found experimentally in laminar jet flames. Flame stability maps in vertically and horizontally injected jet flames are presented. The distinct modes of individual self-excitation are shown to be well described by their own phase diagrams. The results show that buoyancy-driven self-excitation due to the accumulation of partially premixed, preheated mixtures in front of edge flame is branched from the buoyancy-induced self-excitation with O(10 Hz) due to a flame flicker. Once the buoyancy-driven self-excitation appears, it suppresses buoyancy-induced as well as diffusive-thermal self-excitation. The key characteristics for individual self-excitation are discussed and their functional dependencies of Strouhal number upon related physical parameters are also presented.

직류 방전과 펄스 직류 방전에 의한 플라즈마 형상 관찰 (Observation of Plasma Shape by Continuous dc and Pulsed dc)

  • 양원균;주정훈
    • 한국표면공학회지
    • /
    • 제42권3호
    • /
    • pp.133-138
    • /
    • 2009
  • Effects of bipolar pulse driving frequency between 50 kHz and 250 kHz on the discharge shapes were analyzed by measuring plasma characteristics by OES (Optical Emission Spectroscopy) and Langmuir probe. Plasma characteristics were modeled by a simple electric field analysis and fluid plasma modeling. Discharge shapes by a continuous dc and bipolar pulsed dc were different as a dome-type and a vertical column-type at the cathode. From OES, the intensity of 811.5 nm wavelength, the one of the main peaks of Ar, decreased to about 43% from a continuous dc to 100 kHz. For increasing from 100 kHz to 250 kHz, the intensity of 811.5 nm wavelength also decreased by 46%. The electron density decreased by 74% and the electron temperature increased by 36% at the specific position due to the smaller and denser discharge shape for increasing pulse frequency. Through the numerical analysis, the negative glow shape of a continuous dc were similar to the electric potential distribution by FEM (Finite Element Method). For the bipolar pulsed dc, we found that the electron temperature increased to maximum 10 eV due to the voltage spikes by the fast electron acceleration generated in pre-sheath. This may induce the electrons and ions from plasma to increase the energetic substrate bombardment for the dense thin film growth.

케미컬오일을 이용한 ERF 연마 특성 (Characteristics of ERF Polishing using Chemical-oil)

  • 윤종호;이재종;이응숙;이동주;김영호
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.27-33
    • /
    • 2004
  • Electro-theological fluid is recently used for the micro polishing of 3-dimensional micro-aspherical lens. It's also used for polishing small area defects on the wide flat wafer. Since ER fluid shows a behavior of viscosity changing under certain electric fields. micro polishing efficiency may be enhanced for certain cases. In this paper, a perfluorinated carbonyl fluoride oil based ER fluids was used to improve surface polishing rate and submicron-scale accuracy. As the polishing electrodes, micro size cylindrical tools had been used for maximizing the electric field. An experimental device, which was applied for micro polishing a number of wafers of 4inches in size and other workpiece. was made on a precision polishing system. It consisted of a steel electrode. a wafer fixture. l0㎃ current and DC 5㎸ power supply unit, and a controller unit. From the Experiments. the ER fluid is applicable for micro polishing of small parts.

  • PDF

PCB 절연체에서 전하 형성과 수분 흡수 (Water Absorption and Charge Formation in PCB)

  • 이정수;황종선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.233-234
    • /
    • 2008
  • We observed internal space charge behavior for two types of epoxy composites under dc electric fields to investigate the influence of water at high temperature. In the case of glass/epoxy specimen, homocharge is observed at water-treated specimen, and spatial oscillations become clearer in the water-treated specimens. Electric field in the vicinity of the electrodes shows the injection of homocharge. In aramid/epoxy specimens, heterocharge is observed at water-treated specimens, i.e. negative charge accumulates near the anode, while positive charge accumulates near the cathode. Electric field is enhanced just before each electrode. In order to further examine the mechanism of space charge formation, we have developed a new system that allows in situ space charge observation during ion migration tests at high temperature and high humidity. Using this in situ system.

  • PDF