• Title/Summary/Keyword: DC Distribution

Search Result 596, Processing Time 0.027 seconds

Implement High Speed Bidirectional pulse power supply(BPPS) for plating

  • Kim, Tae-Eon;Park, Jong-Oh;Cho, Yong-Seong;Lee, Ihn-Yong;Kim, Young-Han;Lim, Young-Do
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.37.1-37
    • /
    • 2001
  • Electric plating is used in various industry field. Specially, pulse plating is able to deposit material at high current density compared to conventional DC plating. For example, pulse plating can get more fine grain, can improve adhesion and metal distribution and current efficiency, can reduce internal stress and crack. Therefore, we developed bidirection pulse power supply(BPPS) which has high speed pulse current and high current density and improve deposition quality and increase plating speed in this paper. BPPS(Bidirection pulse power supply) needs high speed rising time, falling time and output current accuracy. BPPS consists of rectifier part, chopper part, invertor part, and control part. Rectifier part changes outprt current direction.

  • PDF

An Islanding Detection Method for Distributed Generations Using the Voltage Unbalance (전압 불평형율을 이용한 분산전원의 고립운전 검출 기법)

  • Jang S. I.;Park J. K.;Kim K. H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.42-44
    • /
    • 2004
  • This paper introduced and proposed the voltage unbalance of DC terminal output as new monitoring parameter for power islanding detection. This paper also presented a simple and novel detection algorithm, which effectively combines the detection results of the conventional parameter, voltage magnitude, and a newly proposed parameter. We tested the proposed method using several distribution network conditions including not only islanding operation conditions, but also non-islanding conditions of normal network load variations. The test results showed that the proposed parameters and algorithm are capable of correctly detecting the islanding operation not affected by variation of DG loading and also have a good selectivity for islanding conditions and non-islanding conditions.

  • PDF

MAGNETISM OF NANOPHASE IRON PARTICLES LASER EVAPORATED IN A CONTROLLED OXYGEN ATMOSPHERE

  • Turkki, T.;Jonsson, B.J.;Strom, V.;Medelius, H.;El-Shall, M.S.;Rao, K.V.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.745-748
    • /
    • 1995
  • Magnetic nanoparticles of iron and iron oxide have been prepared in a modified upward thermal diffusion cloud chamber using pulsed laser evaporation. SEM/TEM studies of these particles reveal a size distribution with a mean diameter of about $60\;{\AA}$. FTIR spectrum measurements are used to investigate the difference in oxidation level between nanoparticles prepared at different partial oxygen pressures. The complex magnetic behaviour of these particles was studied using DC- and AC-susceptibility measurements. All samples exhibit superparamagnetism with blocking temperatures ranging from 50 K to above room temperature. The coercivity fields as well as the dependence of the blocking temperature on measuring frequency have been studied. magnetic anisotropy constants are found to be one order of magnitude higher than is known for the bulk values. The mean particle size estimated from the magnetic data is found to be in perfect agreement with the TEM observations.

  • PDF

Average Current Control for Parallel Connected Converters

  • Jassim, Bassim M.H.;Zahawi, Bashar;Atkinson, David J.
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1153-1161
    • /
    • 2019
  • A current sharing controller is proposed in this paper for parallel-connected converters. The proposed controller is based on the calculation of the magnitudes of system current space vectors. Good current distribution between parallel converters is achieved with only one Proportional-Integral (PI) compensator. The proposed controller is analyzed and the circulating current impedance is derived for paralleled systems. The performance of the new control strategy is experimentally verified using two parallel connected converters employing Space Vector Pulse Width Modulation (SVPWM) feeding a passive RL load and a 2.2 kW three-phase induction motor load. The obtained test results show a reduction in the current imbalance ratio between the converters in the experimental setup from 53.9% to only 0.2% with the induction motor load.

Characteristic Distributions of Hydrogen Peroxide and Methyl Hydroperoxide and over the North Pacific Ocean

  • Lee, Meehye;Brian G. Heikes
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E2
    • /
    • pp.85-95
    • /
    • 2002
  • Hydrogen peroxide and methyl hydroperoxide were measured over the northwestern Pacific Ocean during NASA's PEM (Pacific Exploratory Mission) -West. The first experiment (PEM -West A) was conducted in the fall of 1991 and PEM-West B in the early spring of 1994. Hydroperoxide data were obtained on board the NASA DC -8 aircraft through the entire depth of the troposphere. Average concentrations of both H$_2$O$_2$and CH$_3$OOH were higher during PEM -West A than B. The seasonal difference in hydroperoxide distribution was determined by the degree of photochemical activities and the strength and location of jetstream, which led to extensive and rapid continental outflow during the PEM-West B. While for H$_2$O$_2$distribution, a longitudinal gradient was more apparent than a latitudinal gradient, it was opposite for the CH$_3$OOH distribution. The longitudinal gradient indicates the proximity to the anthropogenic sources from the Asian continent, but the latitudinal gradient reflects photochemical activity. During PEM -West B, the ratio of C$_2$H$_2$/CO, a tracer for continental emission was raised and high concentrations of H$_2$O$_2$were associated with high ratios. The flux of hydroperoxide toward the North Pacific was also enhanced in the early spring. The eastward fluxes of H$_2$O$_2$ were 9% and 17% of the average photochemical production over the Pacific Basin between 140°E and 130°W during PEM-West A and B, respectively. For CH$_3$OOH, these ratios were 8% and 13%. Considering the lifetime of hydroperoxide and the rapid transport of pollutants, the export of hydroperoxide with other oxidants would have a significant influence on oxidant cycles over the North Pacific during winter/spring.

Method of Location Decision far a Transfer Center Distributing a Necessary Resource Item while Considering Characteristics of the Material in Wartime (전시 군수물자의 효율적 분배와 수송을 위한 TC 위치선정 방법론 연구)

  • Jung, Byung-Ho;Kim, Ik-Ki
    • Journal of the military operations research society of Korea
    • /
    • v.35 no.2
    • /
    • pp.1-14
    • /
    • 2009
  • During wartime, the Air Force have to plan where, and how much, and what need to be distributed to surrounding local area from a chosen central bases. Each base, which has surplus more than needed amount of a certain material collected from near area of the base, is expected to distribute such surplus to other bases in shortage of it. By sending such surplus to other bases in shortage of the material, every base may get sufficient amount of all kinds of materials needed for each base during wartime. Because number of items of materials needed in each military bases during wartime are usually quite large and the frequencies of delivery from a place to other place are also pretty large if each item is delivered from a surplus place to other places in shortage, the Head Quarter of Air Force or the Logistics Command will face to difficulty to decide a reasonable delivery plan between bases for efficient and fast allocation of all materials needed to all bases during wartime. Therefore, this study suggests a solving algorithm with an established TC (transfer center: collecting and distributing center for all materials) to solve such a distribution and transportation problem.

Induced Polarization Surveys of Contaminants and Introduction to Case Studies (오염원에 대한 유도분극탐사 반응 및 사례 소개)

  • Kim, Bitnarae;Caesary, Desy;Yu, Huieun;Cho, AHyun;Song, Seo Young;Cho, Sung Oh;Joung, Inseok;Nam, Myung Jin
    • Journal of Soil and Groundwater Environment
    • /
    • v.25 no.2_spc
    • /
    • pp.86-100
    • /
    • 2020
  • Analyzing and monitoring environmental contaminants based on geophysical exploration techniques have become important and it is now widely applied to delineate spatial distribution geophysical characteristics in wide area. Among the techniques, induced polarization (IP) method, which measures polarization effects on electrical potential distribution, has drawn much attention as an effective tool for environmental monitoring since IP is sensitive to changes in biochemical reactions. However, various reactions stemming from the presence of multiple contaminants have greatly enhanced heterogeneity of polluted sites to result in highly variable electrical characteristics of the site. Those contaminants influence chemical and physical state of soil and groundwater to alter electrical double layer, which in turn influences polarization of the media. Since biochemical reactions between microbes and contaminants result in various IP effects, IP laboratory experiments were conducted to investigate IP responses of the contaminated soil samples under various conditions. Field IP surveys can delineate the spatial distribution of contamination, while providing additional information about electrical properties of a target medium, together with DC resistivity. Reviewing IP effects of contaminants as well as IP surveys can serve as a good starting point for the application of IP survey in site assessment for environmental remediation.

Effect of Magnetic Field Annealing on Microstructure and Magnetic Properties of FeCuNbSiB Nanocrystalline Magnetic Core with High Inductance

  • Fan, Xingdu;Zhu, Fangliang;Wang, Qianqian;Jiang, Mufeng;Shen, Baolong
    • Applied Microscopy
    • /
    • v.47 no.1
    • /
    • pp.29-35
    • /
    • 2017
  • Transverse magnetic field annealing (TFA) was carried out on $Fe_{73.5}Cu_1Nb_3Si_{15.5}B_7$ nano-crystalline magnetic core with the aim at decreasing coercivity ($H_c$) while keeping high inductance ($L_s$). The magnetic field generated by direct current (DC) was applied on the magnetic core during different selected annealing stages and it was proved that the nanocrystalline magnetic core achieved lowest $H_c$ when applying transverse field during the whole annealing process (TFA1). Although the microstructure and crystallization degree of the nanocrystalline magnetic core exhibited no obvious difference after TFA1 compared to no field annealing, the TFA1 sample showed a more uniform nanostructure with a smaller mean square deviation of grain size distribution. $H_c$ of the nanocrystalline magnetic core annealed under TFA1 decreased along with the increasing magnetic field. As a result, the certain size nanocrystalline magnetic core with low $H_c$ of 0.6 A/m, low core loss (W at 20 kHz) of 1.6 W/kg under flux density of 0.2 T and high $L_s$ of $13.8{\mu}H$ were obtained after TFA1 with the DC intensity of 140 A. The combination of high $L_s$ with excellent magnetic properties promised this nanocrystalline alloy an outstanding economical application in high frequency transformers.

A Study on the Sodium and Moisture Gettering in PSG/SiO2 Passivated Al-1%Si Thin Film Interconnections (PSG/SiO2 보호막 처리된 Al-1%Si 박막배선에서의 Sodium과 수분 게터링에 관한 연구)

  • Kim, Jin Young
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.3
    • /
    • pp.126-130
    • /
    • 2013
  • The sodium (Na) and moisture ($H_2O$) gettering phenomena were measured and analyzed in PSG/$SiO_2$ passivated Al-1%Si thin film interconnections. PSG/$SiO_2$ passivation and Al-1%Si thin films were deposited by using APCVD (atmosphere pressure chemical vapor deposition) and DC magnetron sputter techniques, respectively. SIMS (secondary ion mass spectrometry) depth profiling analysis was used to determine the distribution of sodium and moisture throughout the PSG/$SiO_2$ passivated Al-1%Si thin film interconnections. Both sodium and moisture peaks were observed strongly at the interfaces between layers rather than within the Al-1%Si thin film interconnections. Sodium peaks were observed at the interface between PSG and $SiO_2$ passivations, while moisture peaks were not observed.

Characteristics of Fracture System of the Upper Devonian Grosmont Formation, Alberta, Canada (캐나다 앨버타 상부 데본기 Grosmont층의 불연속면 구조 특성)

  • Um, Jeong-Gi;Kim, Min-Sung;Choh, Suk-Joo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.790-799
    • /
    • 2010
  • The Upper Devonian Grossmont Formation in Alberta, Canada reserves an estimated 50 billion cubic meters of bitumen and possess about 1/6 of the total bitumen resources in northern Alberta. However, unlike the overlying Athabasca oil sands, non conventional bitumen resources has not been developed as yet. The carbonate rocks of Grosmont Formation have been subject to various stages of diagenesis, including dolomatization and karstification with a strong effect on the distribution of porosity and permeability, which resulted in highly heterogeneous reservoirs. An extensive fracture logging and mapping was performed on total of six boreholes located in the study area to explore the characteristics of fracture geometry system and the subsurface structures of carbonates reservoir that holds bitumen. Fractal dimension was used as a measure of the statistical homogeneity of the fractured rock masses. The applicability of random Cantor dust, Dc, as a fractal parameter was examined systematically. The statistical homogeneity of fractured carbonates rock masses was investigated in the study area. The structural domains of the rock masses were delineated depthwise according to estimated Dc. The major fracture orientation was dominated by horizontal beddings having dip of $0-20^{\circ}$. Also, fractures having high dip angles existed with relatively low frequency. Three dimensional fracture network modeling for each structural domain has been performed based on fracture orientation and intensity, and some representative conceptual models for carbonates reservoir in the study area has been proposed. The developed subsurface conceptual models will be used to capture the geomechanical characteristics of the carbonates reservoir.

  • PDF