• 제목/요약/키워드: DC Distribution

검색결과 596건 처리시간 0.032초

새로운 선로용량을 고려한 전력계통의 상정사고 선택 (Contigency Ranking Technique Using New Line Capacity)

  • 박규홍;조양행
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.95-98
    • /
    • 2000
  • This paper presents a technique for contingency ranking using line capacity calculation method and outage distribution factors (LODF) which are established by generation shift distribution factors from DC load flow solutions. By using the LODF, the line flow can be calculated a ccording to the modification of base load flow if the contingency occur. To obtain contingency ranking, maximum power tansferred to the load is obtained when load impedance $Z_r$ equal to line impedance $Z_s$. The proposed algorithm has been validated in tests on a 6-bus test system.

  • PDF

고분자애자의 표면전하밀도 분포에 관한 연구 (A Study on The Distribution of Surface Charge Density on Polymer Insulators)

  • 양재진;황복명;김관성;이준호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.354-356
    • /
    • 1997
  • In this paper, we study the distribution of surface charge density on polymer insulators. The electric field of polymer insulators is calculated by axisymetric 3-D FEM with dc source. And the surface charge density is calculated by electric scalar potential and boundary condition for electrostatic fields. Simulation model is the inclined type polymer insulator with a shed.

  • PDF

PEA법에 의한 캐패시터내 전하분포 측정 (Charge Distribution in a capacitor observed by PEA Method)

  • ;한덕우;곽동주;성열문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1156-1157
    • /
    • 2008
  • The use of the pulsed electro acoustic (PEA) method allowed us to perform the direct observations of spatio-temporal charge distributions in Electric double layer capacitors (EDLCs) based on polarizable nanoporous carbonaceous electrode. The negative charge density became the maximum, about 205 $C/m^3$ at the region where was near to collector layer in EDLCs for case $V_{DC}$ = 2.5 V, while the positively charged density became the maximum, about 61.1 $C/m^3$ at the region where it was located around the cathode layer. The PEA measurement used here is a very useful method to quantitively investigates the spatio-temporal charge distribution in EDLCs.

  • PDF

유연송전시스템에서의 역률 보상을 위한 배전용 정지형 동기조상기의 전류제어 (Predictive Current Control of Distribution Static Condenser (D-STATCON) for Reactive Power Compensation in Flexible AC Transmission System(FACTS))

  • 오관일;문건우;전영수;이기선;추진부
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.447-454
    • /
    • 1998
  • This paper describes a modeling and current control techniques of Distribution static condenser (D-STATCON) for power factor compensation. The current control is based on the predictive and the space vector PWM scheme. The predictive current controlled PWM D-STATCON can maintain its performance with power factor compensation and fixed switching frequency. By using the space vector control low ripple and offset in the current and the voltage as well as fast dynamic responses are achieved with a small DC link capacitance employed.

  • PDF

분산전원 연계형 UPQC(Unified Power Quality Conditioner)의 성능해석 (Performance Analysis for the UPQC(Unified Power Quality Conditioner) Interconnected to the Distributed Generation System)

  • 김희중;배병열;한병문
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권3호
    • /
    • pp.152-160
    • /
    • 2004
  • A novel UPQC(Unified Power Quality Conditioner), which consists of series inverter, shunt inverter, distributed generation system, is proposed. The proposing system can compensate reactive power, harmonics, voltage sag and swell, voltage interruption etc. through the change of paralleling operation mode and islanding operation mode. The control strategy for the proposing system was derived using the instantaneous power method. The performance of proposing system was analyzed by means of the PSCAD/EMTDC simulation and the experimental work with the hardware prototype. The proposing system has the ultimate capability of improving power quality at the point of installation on power distribution systems or Industrial power systems and can be utilized for the custom power device in th future distribution system.

흡수열화에 따른 Epoxy/$SiO_2$ 복합체의 전기적 특성 및 수명예측 (Electrical Properties and Lifetime Prediction of Epoxy/$SiO_2$Composites with Water Absorption Ageing)

  • 김탁용;이덕진;홍진웅
    • 한국전기전자재료학회논문지
    • /
    • 제13권9호
    • /
    • pp.758-763
    • /
    • 2000
  • Dielectric strength of insulators made of epoxy composites rapidly decreases due to ageing to interfaces between the matric resin and filler particles. The adhesion variation of interfaces caused by moisture absorption also alters electrical properties that are the basic characteristics of insulators, particularly, in outdoor use. In this paper, electrical properties of epox/SiO$_2$composites were investigated at boiling absorption condition to observe the influences of moisture. In order to analyze the basic physical properties of samples, scanning electron microscopy and DC, AC and impulse voltage dielectric strength were measured. Also, the breakdown time of samples was measured under AC 6[kV] applied voltage, and the variation of lifetime was verified by using Weibull distribution function.

  • PDF

Effect of RF Bias on Plasma Parameters and Electron Energy Distribution in RF Biased Inductively Coupled Plasma

  • Lee, Hyo-Chang;Chung, Chin-Wook
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.492-492
    • /
    • 2012
  • RF biased inductively coupled plasma (ICP) has been widely used in various semiconductor etching processes and laboratory plasma researches. However, almost researches for the RF bias have been focused on the controls of dc self-bias voltages, even though the RF bias can change plasma parameters, such as electron temperature, plasma density, electron energy distribution (EED), and their spatial distributions. In this study, we report on the effect of the RF bias on the plasma parameters and the EEDs with various external parameters, such the RF bias power, the ICP power, the gas pressure, the gas mixture, and the frequency of RF bias. Our study shows the correlation between the RF bias and the plasma parameters and gives a crucial key for the understanding of collisionless electron heating mechanism in the RF biased ICP.

  • PDF

C type 영구자석을 갖는 BLDC 모터의 특성 해석 (Characteristics Analysis of BLOC Motor with C type Permanent Magnet)

  • 류세현;임태빈;정중기;하근수;이성호;이병호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.50-52
    • /
    • 2001
  • The BLDC(Brushless DC) motor with the permanent magnet has many merits such as high efficiency and efficiency. These characteristics of the BLDC motor makes them one of the most popular motors in the world today. The C type ferrite magnet is many used in BLDC motor for high performance, especilly low price. Many papers have been written on the analysis of the BLDC motor with C type ferrite magnet. But, most of these target models are contained symmetric distribution of permanent magnet. In this paper, investigations are made on different distribution of permanent magnets for a understanding of the effects of unequal permanent magnet location on the unbalanced cogging torque. Motor torque and cogging torque are obtained by using the 2 dimensional finite element method.

  • PDF

유통업체간 제휴를 위한 공급체인 재설계에 의한 물동량 감소효과 분석: 시스템다이내믹스를 이용한 시뮬레이션 (An Analysis on the Reduction Effect of Freight Volume by Supply Chain Redesign for the Alliance of Distributors: A Simulation Using System Dynamics)

  • 박세훈;문성암
    • 한국시스템다이내믹스연구
    • /
    • 제12권3호
    • /
    • pp.67-86
    • /
    • 2011
  • This study shows the reduction effect of freight volume by the supply chain redesign for the alliance of distributors with system dynamics simulation. The as-is model is composed of 3 independent companies which one has 3 distribution centers (DCS) and 24 agents, another has 1 dc and 9 agents, the other has 3 DCS and 15 agents each. The to-be model is an integrated logistics model and composed of 1 company having 5 areal DCS and 38 agents. Each agent in the same area is integrated with each other. Two models have same demands but very different result. As a result, the freight volume between DCS and agents is reduced by 33.55%. This case study will be useful to analyze the similar cases about the logistics integration by supply chain redesign.

  • PDF

전기이중층 캐패시터 내의 전하분포 고찰 (Investigation of Charge distribution in an Electric double layer capacitor)

  • ;;성열문;김광태
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.201-204
    • /
    • 2008
  • The use of the pulsed electro acoustic (PEA) method allowed us to perform the direct observations of spatio-temporal charge distributions in Electric double layer capacitors (EDLCs) based on polarizable nanoporous carbonaceous electrode. The negative charge density became the maximum, about 205 C/$m^3$ at the region where was near to collector layer in EDLCs for case $V_{DC}$ = 2.5 V, while the positively charged density became the maximum, about 61.1 C/$m^3$ at the region where it was located around the cathode layer. The PEA measurement used here is a very useful method to quantitively investigates the spatio-temporal charge distribution in EDLCs.

  • PDF