• Title/Summary/Keyword: DC Circuit

Search Result 2,003, Processing Time 0.029 seconds

Low Conversion Loss 94 GHz MHEMT MIMIC Resistive Mixer (낮은 변환손실 특성의 94 GHz MHEMT MIMIC Resistive 믹서)

  • An Dan;Lee Bok-Hyung;Lim Byeong-Ok;Lee Mun-Kyo;Oh Jung-Hun;Baek Yong-Hyun;Kim Sung-Chan;Park Jung-Dong;Shin Dong-Hoon;Park Hyung-Moo;Park Hyun-Chang;Kim Sam-Dong;Rhee Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.5 s.335
    • /
    • pp.61-68
    • /
    • 2005
  • In this paper, low conversion loss 94 GHz MIMIC resistive mixer was designed and fabricated. The $0.1{\mu}m$ InGaAs/InAlAs/GaAs Metamorphic HEMT, which is applicable to MIMIC's, was fabricated. The DC characteristics of MHEMT are 665 mA/mm of drain current density, 691 mS/mm of maximum transconductance. The current gain cut-off frequency(fT) is 189 GHz and the maximum oscillation frequency(fmax) is 334 GHz. A 94 GHz resistive mixer was fabricated using $0.1{\mu}m$ MHEMT MIMIC process. From the measurement, the conversion loss of the 94 GHz resistive mixer was 8.2 dB at an LO power of 10 dBm. P1 dB(1 dB compression point) of input and output were 9 dBm and 0 dBm, respectively. LO-RF isolations of resistive mixer was obtained 15.6 dB at 94.03 GHz. We obtained in this study a lower conversion loss compared to some other resistive mixers in W-band frequencies.

The Development of Portable Digital X-ray Power Supply Unit for Emergency Medical Services (응급의료에서 이용될 휴대용 디지털 X-ray 전원장치 개발)

  • Cho, Dong-Heon;Koo, Kyung-Wan;Yong, Hae-Sool
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.125-131
    • /
    • 2006
  • The existing X-ray generators are either ones which are settled at fixed places or ones which are movable to sick rum. Movable generators can be very useful according to the circumstances of patients, but there remains a restraint that AC220[V] in the hospitals must be provided. When examining a first-aid patient who stays distant from the hospital or when grouping patients caused by disaster, the services of doctors at emergency centers should be very restrictive. Hence, this study developed a portable digital X-ray power supply unit that are utilizable at the accident spot or in a moving ambulance. By using the nit, the information of patients can be transmitted to the emergency center on the spot and thereby doctors can make a correct diagnosis. The properties of the unit are as follows: First, portable batteries(DCl2[V]) are utilized as electric source for the wit. Second PIC16F84A is utilized as control circuit in order to guarantee considerable reliance and to provide various functions. This portable digital X-ray power supply unit is expected to contribute to the emergency medical service system to be more advanced.

A Wideband ${\Delta}{\Sigma}$ Frequency Synthesizer for T-DMB/DAB/FM Applications in $0.13{\mu}m$ CMOS (T-DMB/DAB/FM 수신기를 위한 광대역 델타시그마 분수분주형 주파수합성기)

  • Shin, Jae-Wook;Shin, Hyun-Chol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.12
    • /
    • pp.75-82
    • /
    • 2010
  • This paper presents a wideband ${\Delta}{\Sigma}$ fractional-N frequency synthesizer for a multi-band single chip CMOS RFIC transceivers. A wideband VCO utilizes a 6-bit switched capacitor array bank for 2340~3940 MHz frequency range. VCO frequency calibration circuit is designed for optimal capacitor bank code selection before phase locking process. It finishes the calibration process in $2{\mu}s$ over the whole frequency band. The LO generation block has selectable multiple division ratios of ${\div}2$, ${\div}16$, and ${\div}32$ to generate LO I/Q signals for T-DMB/DAB/FM Radio systems in L-Band (1173~1973 MHz), VHF-III (147~246 MHz), VFH-II (74~123 MHz), respectively. The measured integrated phase noise is quite low as it is lower than 0.8 degree RMS over the whole frequency band. Total locking time of the ${\Delta}{\Sigma}$ frequency synthesizer including VCO frequency calibration time is less than $50{\mu}s$. The wideband ${\Delta}{\Sigma}$ fractional-N frequency synthesizer is fabricated in $0.13{\mu}m$ CMOS technology, and it consumes 15.8 mA from 1.2 V DC supply.

A 2 GHz Compact Analog Phase Shifter with a Linear Phase-Tune Characteristic (2 GHz 선형 위상 천이 특성을 갖는 소형 아날로그 위상천이기)

  • Oh, Hyun-Seok;Choi, Jae-Hong;Jeong, Hae-Chang;Heo, Yun-Seong;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.1
    • /
    • pp.114-124
    • /
    • 2011
  • In this paper, we present a 2 GHz compact analog phase shifter with linear phase-tune characteristic. The compact phase shifter was designed base on a lumped all pass network and implemented using a ceramic substrate fabricated with thin-film technique. For a linear phase-tune characteristic, a capacitance of the varactor diode for a tuning voltage was linearized by connecting series capacitor and subsequently produced an almost linear capacitance change. The inductor and bias circuit in the all pass network was implemented using a spiral inductors for small size, which results in the size reduction to $4\;mm{\times}4\;mm$. In order to measure the phase shifter using the probe station, two CPW pads are included at the input and output. The fabricated phase shifter showed an insertion loss of about 4.2~4.7 dB at 2 GHz band and a total $79^{\circ}$ phase change for DC control voltage from 0 to 5 V, and showed linear phase-tune characteristic as expected in the design.

High Gain and Broadband Millimeter-wave MHEMT Cascode Amplifier (고이득 및 광대역 특성의 밀리미터파 MHEMT Cascode 증폭기)

  • An, Dan;Lee, Bok-Hyung;Lim, Byeong-Ok;Lee, Mun-Kyo;Baek, Yong-Hyun;Chae, Yeon-Sik;Park, Hyung-Moo;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.8
    • /
    • pp.105-111
    • /
    • 2004
  • In this paper, millimeter-wave high gain and broadband MHEMT cascode amplifiers were designed and fabricated. The 0.1 ${\mu}{\textrm}{m}$ InGaAs/InAlAs/GaAs Metamorphic HEMT was fabricated for cascode amplifiers. The DC characteristics of MHEMT are 640 mA/mm of drain current density, 653 mS/mm of maximum transconductance. The current gain cut-off frequency(f$_{T}$) is 173 GHz and the maximum oscillation frequency(f$_{max}$) is 271 GHz. By using the CPW transmission line, the cascode amplifier was designed the matched circuit for getting the broadband characteristics. The designed amplifier was fabricated by the MHEMT MIMIC process that was developed through this research. As the results of measurement, the 1 stage amplifier obtained 3 dB bandwidth of 37 GHz between 31.3 to 68.3 GHz. Also, this amplifier represents the S21 gain with the average 9.7 dB gain in bandwidth and the maximum gain of 11.3 dB at 40 GHz. The 2 stage amplifier has the broadband characteristics with 3 dB bandwidth of 29.5 GHz in the frequency range from 32.5 to 62.0 GHz. The 2 stage cascode amplifier represents the high gain characteristics with the average gain of 20.4 dB in bandwidth and the maximum gain of 22.3 dB at 36.5 GHz.z.z.

EFFECTS OF SMEAR LAYER AND DENTIN PRIMERS ON THE SEALING ABILITY OF ROOT CANAL (근관 밀폐도에 미치는 도말층 및 상아질 접착강화제의 영향)

  • Yang, Jin-Suck;Hwang, In-Nam;Kim, Won-Jae;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.527-535
    • /
    • 2000
  • The purpose of this study was to evaluate effects of smear layer and dentin primers on the sealing ability of root canals. 126 extracted human teeth with single, straight canals and mature apices were used. The Samples were first classified into six groups as follows: presence of smear layer; absence of smear layer; Scotchbond Bond Multi-Purpose; All Bond 2; Mac Bond 2; Clearfil Liner Bond 2. A Positive control was also established. All teeth except the control group were then obturated with thermoplasticized gutta-percha and AH26. Electrochemical and dye penetration technique were later used to evaluate the degree of micro leakage through the root canal. Seventy teeth were then immersed in a 1% potassium chloride solution and An external power supply(DC 10 V) was then applied to the circuit for the electrochemical microleakage test. The degree of Microleakage was determined over period of 28 days before being evaluated. In total, 48 teeth were submitted to the dye infiltration technique. All specimen were suspended in 2% methylene blue dye for 1 week before being longitudinally split. The degree of dye infiltration was measured under a stereo microscope at ${\times}10$ magnification and evaluated. The results were as follows: 1. Apical microleakage increased throughout the test period in all group and one group having a smear layer showed a dramatic increase under electrochemical test (p<0.05). In the group having smear layer, the degree of apical microleakage was the highest, and the micro leakage was much higher than in the smear layer removed group in electrochemical test (p<0.05). Scotchbond Multi-Purpose, All Bond 2, Mac Bond 2 and Clearfil Liner Bond 2 showed lower micro leakage than one group having smear layer. The All Bond 2 and Clearfil Liner Bond 2 treated groups showed the lowest microleakage in electrochemical test (p<0.05). 2. There was no significant difference between the experimental groups in dye penetration technique. These results suggested that the removal of the smear layer from root canal and concomitantly the application of dentin primer into root canal could improve the sealing ability of root canal obturation.

  • PDF

Harmonic Reduction Scheme By the Advanced Auxiliary Voltage Supply (개선된 보조전원장치에 의한 고조파 저감대책)

  • Yoon, Doo-O;Yoon, Kyoung-Kuk;Kim, Sung-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.6
    • /
    • pp.759-769
    • /
    • 2015
  • Diode rectifiers are very popular in industry. However, they include large low-order harmonics in the input current and do not satisfy harmonic current content restrictions. To reduce the harmonics to the power system, several methods have been introduced. It is heavy and expensive solution to use passive filters as the solution for high power application. Another solution for the harmonic filter is utilization of active filter, but it is too expensive solution. Diode rectifiers with configurations using switching device have been introduced, but they are very complicated. The combined 12-pulse diode rectifier with the square auxiliary voltage supply has been introduced. It has the advantages that auxiliary circuit is simple and inexpensive compared to other strategies. The advanced auxiliary voltage supply in this thesis is presented as a new solution. When the square auxiliary voltage supply applied, the improvement of THD is 6~60[%] in whole load range. But when the advanced auxiliary voltage supply applied, it shows stable and excellent reduction effect of THD as 57~71[%]. Especially, for the case with 10[%] load factor, reduction effect of THD has little effect as 6[%] in the case of inserting a square auxiliary voltage supply. But when the proposed new solution applied, reduction effect has excellent effect as 71[%]. Theoretical analysis of the combined 12-pulse diode rectifier with the advanced auxiliary voltage supply is presented and control methods of the auxiliary supply is proposed. The reduction in the input current harmonics is verified by simulation using software PSIM.

A Study on Implementation and Performance Evaluation of Error Amplifier for the Feedforward Linear Power Amplifier (Feedforward 선형 전력증폭기를 위한 에러증폭기의 구현 및 성능평가에 관한 연구)

  • Jeon, Joong-Sung;Cho, Hee-Jea;Kim, Seon-Keun;Kim, Ki-Moon
    • Journal of Navigation and Port Research
    • /
    • v.27 no.2
    • /
    • pp.209-215
    • /
    • 2003
  • In this paper. We tested and fabricated the error amplifier for the 15 Watt linear power amplifier for the IMT-2000 baseband station. The error amplifier was comprised of subtractor for detecting intermodulation distortion, variable attenuator for control amplitude, variable phase shifter for control phase, low power amplifier and high power amplifier. This component was designed on the RO4350 substrate and integrated the aluminum case with active biasing circuit. For suppression of spurious, the through capacitance was used. The characteristics of error amplifier measured up to 45 dB gain, $\pm$0.66 dB gain flatness and -15 dB input return loss. Results of application to the 15 Watt feedforward Linear Power Amplifier, the error amplifier improved with 27 dB cancellation from 34 dBc to 61 dBc IM$_3$.

New Implementation Method of the Pulsed Nuclear Magnetic Resonance Apparatus (펄스방식의 핵자기 공명장치에 관한 새로운 구현방법)

  • 김청월
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.10
    • /
    • pp.1-11
    • /
    • 1998
  • This paper presents a new implementation method of the pulsed NMR(nuclear magnetic resonance) apparatus, which contains a single coil in a magnet console, to detect a NMR signal. Applying an RF magnetic field of 5MHz to the magnet console which is designed to have Larmor frequency of 5MHz for hydrogen atom, the hydrogen NMR signal was obtained from the glycerin which was put in the magnet console as a sample. The DC magnetic field in the magnet console was implemented with a permanent magnet of 1168 gauss and the RF magnetic field was generated appling an RF signal with the frequency of 5MHz and the current magnitude of 8A to a coil of 5.73${\mu}$H. The magnitude of the NMR signal was maximum when the RF magnetic field was generated for 2.8 ${\mu}$sec, and the period of generating the RF magnetic field was designed to 100msec for detecting the NMR signal repeatedly. The NMR signal, radiated from the sample in the magnetic console, was appeared as an amplitude-modulated signal with a frequency equal to the Larmor frequency. The signal, induced in the coil, was amplified in the tx/rx separation circuit, preamplifier and intermediate amplifier by a factor of 20.7dB, 36dB and 40dB, respectively, and the signal was detected by a synchronous detection circuits, then the NMR signal was obtained.

  • PDF

DEVELOPMENT OF THE READOUT CONTROLLER FOR INFRARED ARRAY (적외선검출기 READOUT CONTROLLER 개발)

  • Cho, Seoung-Hyun;Jin, Ho;Nam, Uk-Won;Cha, Sang-Mok;Lee, Sung-Ho;Yuk, In-Soo;Park, Young-Sik;Pak, Soo-Jong;Han, Won-Yong;Kim, Sung-Soo
    • Publications of The Korean Astronomical Society
    • /
    • v.21 no.2
    • /
    • pp.67-74
    • /
    • 2006
  • We have developed a control electronics system for an infrared detector array of KASINICS (KASI Near Infrared Camera System), which is a new ground-based instrument of the Korea Astronomy and Space science Institute (KASI). Equipped with a $512{\times}512$ InSb array (ALADDIN III Quadrant, manufactured by Raytheon) sensitive from 1 to $5{\mu}m$, KASINICS will be used at J, H, Ks, and L-bands. The controller consists of DSP(Digital Signal Processor), Bias, Clock, and Video boards which are installed on a single VME-bus backplane. TMS320C6713DSP, FPGA(Field Programmable Gate Array), and 384-MB SDRAM(Synchronous Dynamic Random Access Memory) are included in the DSP board. DSP board manages entire electronics system, generates digital clock patterns and communicates with a PC using USB 2.0 interface. The clock patterns are downloaded from a PC and stored on the FPGA. UART is used for the communication with peripherals. Video board has 4 channel ADC which converts video signal into 16-bit digital numbers. Two video boards are installed on the controller for ALADDIN array. The Bias board provides 16 dc bias voltages and the Clock board has 15 clock channels. We have also coded a DSP firmware and a test version of control software in C-language. The controller is flexible enough to operate a wide range of IR array and CCD. Operational tests of the controller have been successfully finished using a test ROIC (Read-Out Integrated Circuit).