• Title/Summary/Keyword: DBD

Search Result 259, Processing Time 0.034 seconds

Dielectric Barrier Discharge for Ultraviolet Light Generation and Its Efficient Driving Inverter Circuit

  • Oleg, Kudryavtsev;Ahmed, Tarek;Nakaoka, Mutsuo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.3
    • /
    • pp.101-105
    • /
    • 2004
  • The efficient power MOSFET inverter applied for a simple and low cost power supply is proposed for driving the dielectric barrier discharge (DBD) lamp load. For decades, the DBD phenomenon has been used for ozone gas production in industry. In this research, the ultraviolet and visible light sources utilizing the DBD lamp is considered as the load for solid-state high frequency power supply. It is found that the simple voltage-source single-ended quasi-resonant ZVS inverter with only one active power switch could effectively drive this load with the output power up to 700 W. The pulse density modulation based control scheme for the single-ended quasi-resonant ZVS inverter using a low voltage and high current power MOSFET switching device is proposed to provide a linear power regulation characteristic in the wide range 0-100% of the full power as compared with the conventional control based Royer type parallel resonant inverter type power supplies.

Dynamic Analysis on the Double Bill Detector of ATM (ATM 2매검지부의 동적해석)

  • Suh, Jun-Ho;Baek, Yoon-kil;Choi, Yeon-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.848-851
    • /
    • 2005
  • ATM(Automated-feller Machine) is a machine that receives and pays money directly. The double bill detector (DBD) module of an ATM detects double bill from its thickness. In this paper, the dynamic behavior of the DBD was analyzed numerically and experimentally. The moment of inertia of the double bill lever and the spring constant were measured respectively. And the displacements of the ]ever was measured experimentally. The measured dynamic behaviors were simulated numerically using vector equation. Through the analysis, the design factors were found to make a fast and reliable new ATM machine.

  • PDF

Inactivation of Zooplankton Artemia sp. Using Plasma Process (플라즈마 공정을 이용한 동물성 플랑크톤 Artemia sp. 불활성화)

  • Dong-Seog Kim;Young-Seek Park
    • Journal of Environmental Science International
    • /
    • v.32 no.3
    • /
    • pp.197-204
    • /
    • 2023
  • This study aims to inactivate Artemia sp. (Zooplankton) in ballast water through the dielectric barrier discharge (DBD) plasma process. The DBD plasma process has the advantage of enabling direct electric discharge in water and utilizing chemically active species generated by the plasma reaction. The experimental conditions for plasma reaction are as follows; high voltage of 9-22 kV, plasma reaction time of 15-600 s, and air flow rate of 0.5-5.5 L/min. The results showed that the optimal experimental conditions for Artemia sp inactivation were 16 kV, 60 s, 2.5 L/min, respectively. The concentrations of total residual oxidants and ozone generated by plasma reaction increased with an increase of in voltage and reaction time, and the concentration of generated air did not increase above a certain amount.

Development of a pulse input inverter circuit for plasma air cleaner (DBD 플라즈마 공기청정기를 위한 펄스 전원 입력 인버터 회로 개발)

  • Hwang, Hoon Ha;Jeon, Hyeong Geun;Oh, Hyeon Jun;Lee, Young Hwi;Roh, Chung Wook
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.227-229
    • /
    • 2020
  • 차량 또는 실내에서 사용되는 대부분의 공기청정기는 미세먼지(PM 또는 PM)를 필터만 이용해서 정화하기 때문에 일정 시간 사용하게 되면 필터를 교체해야 하고, 필터를 청소한다고 해도 점점 성능이 저하되어 교체만 한다. 이러한 점이 개선된 플라즈마 공기청정기의 경우 필터 공기청정기에 비해 소비전력이 크다는 문제가 있다. 본 논문에서는 기존 플라이백 컨버터를 이용한 플라즈마 구동이 아닌 단일 스위치 무손실 인버터(국민대 보유기슬)와 펄스 전원(맥동 전압) 인가를 통한 플라즈마 구동 방식을 제안하고, 기존 DBD 플라즈마 방식이 아닌 자력을 이용한 DBD 플라즈마 리액터의 사용을 제안한다. 그리고 실제 실험 및 측정을 통해 제안 방식의 실효성을 검증하였다.

  • PDF

A Foreign Cases Study of the Deep Borehole Disposal System for High-Level Radioactive Waste (고준위 방사성폐기물 심부시추공 처분시스템 개발 해외사례 분석)

  • Lee, Jongyoul;Kim, Geonyoung;Bae, Daeseok;Kim, Kyeongsoo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.2
    • /
    • pp.121-133
    • /
    • 2014
  • If the spent fuels or the high-level radioactive wastes can be disposed of in the depth of 3~5 km and more stable rock formation, it has several advantages. For example, (1)significant fluid flow through basement rock is prevented, in part, by low permeability, poorly connected transport pathways, and (2)overburden self-sealing. (3)Deep fluids also resist vertical movement because they are density stratified and reducing conditions will sharply limit solubility of most dose-critical radionuclides at the depth. Finally, (4) high ionic strengths of deep fluids will prevent colloidal transport. Therefore, as an alternative disposal concept to the deep geological disposal concept(DGD), very deep borehole disposal(DBD) technology is under consideration in number of countries in terms of its outstanding safety and cost effectiveness. In this paper, for the preliminary applicability analyses of the DBD system for the spent fuels or high level wastes, the DBD concepts which have been developed by some countries according to the rapid advance in the development of drilling technology were reviewed. To do this, the general concept of DBD system was checked and the study cases of foreign countries were described and analyzed. These results will be used as an input for the analyses of applicability for DBD in Korea.

Characteristics of Ozone Decomposition for DBD-type Air Cleaner Using Pelletized MnO$_2$ Catalyst and Activated Carbon (조립상 촉매(MnO$_2$)와 활성탄을 이용한 DBD방식 공기청정기에서의 발생 오존 분해특성)

  • 변정훈;지준호;강석훈;황정호
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.173-174
    • /
    • 2002
  • 실내 공기질은 재실자의 건강과 쾌적성 뿐만 아니라, 생산성 및 작업능률에도 영향을 미치며, 산업화와 자동차의 증가로 인한 대기오염은, 실내 공기질에 악영향을 미치고 있다. 또한, 에너지 절약을 위한 건물의 밀폐화와 환기율의 감소로 실내공기오염에 대한 관심도 증가되고 있다. 이는 결국, 보다 체계적이고 실용적인 공기정화 시스템의 필요로 이어지며, 그런 의미에서 현재 많은 상용 공기청정기에 대한 보다 효과적인 평가가 필요하다. (중략)

  • PDF

Interferon consensus sequence binding protein : Not essential for interferon α-mediated antiviral response to vesicular stomatitis virus infection in HL-60 cells

  • Park, Byung-Kiu
    • IMMUNE NETWORK
    • /
    • v.1 no.2
    • /
    • pp.109-115
    • /
    • 2001
  • Background: The role of the interferon consensus sequence binding protein (ICSBP), a member of interferon regulatory factor family, in protecting against a vesicular stomatitis virus (VSV) infection has not been firmly elucidated. Thus, it was investigated utilizing the human promyelocytic leukemia HL-60 cells which do not express ICSBP. Methods: HL-60 cells were stably transfected with plasmid containing cDNA for either ICSBP or DNA binding domain (DBD) and tested for their VSV-susceptibilities. The susceptibility of each transfectant group to a VSV infection was determined by a plaque assay at 1 h, 24 h, and 48 h post-infection in the presence (500 IU/ml) or absence of interferon ${\alpha}$ ($IFN{\alpha}$). Results: In the absence of $IFN{\alpha}$, the three groups showed similar sensitivities to a VSV infection. However, when pre-treated with IFN, the viral titers in both the ICSBP and control clones steadily decreased over 48 h of incubation, indicating the existence of $IFN{\alpha}$-mediated protection against VSV infection. The $IFN{\alpha}$-treated ICSBP clones appeared to be more resistant to infection compared with the control clones, although the difference was not great. On the contrary, the viral titers in the $IFN{\alpha}$-treated DBD clones increased at 24 h then decreased by 48 h. Conclusion: The expression of truncated ICSBP (DBD) does not appear to underlie the impaired protection against a VSV infection in the DBD clones, since even the control clones lacking ICSBP were protected from a VSV infection. This suggests that ICSBP does not play a critical role in the $IFN{\alpha}$- mediated anti-VSV response of HL-60 cells, although it appears to confer some resistance to a VSV infection.

  • PDF

Application of DBD Plasma Catalysis Hybrid Process to remove Organic Acids in Odors (악취물질인 유기산 제거를 위한 DBD 플라즈마 촉매 복합공정의 적용)

  • Hong, Eun-Gi;Suh, Jeong-Min;Choi, Kum-Chan
    • Journal of Environmental Science International
    • /
    • v.23 no.9
    • /
    • pp.1627-1634
    • /
    • 2014
  • Odor control technology include absorption, adsorption, incineration and biological treatments. But, most of processes have some problems such as secondary organic acids discharge at the final odor treatment facility. In order to solve the problems for effective treatment of organic acids in odor, it is necessary to develop a new type advanced odor control technology. Some of the technology are plasma only process and plasma hybrid process as key process of the advanced technology. In this study, odor removal performance was compared DBD(Dielectric Barrier Discharge)plasma process with PCHP(plasma catalysis hybrid process) by gaseous ammonia, formaldehyde and acetic acid. Plasma only process by acetic acid obtained higher treatment efficiency above 90%, and PCHP reached its efficiency up to 96%. Acetic acid is relatively easy pollutant to control its concentration other than sulfur and nitrogen odor compounds, because it has tendency to react with water quickly. To test of the performance of DBD plasma process by applied voltage, the tests were conducted to find the dependence of experimental conditions of the applied voltage at 13 kV and 15 kV separately. With an applied voltage at 15 kV, the treatment efficiency was achieved to more higher than 13 kV from 83% to 99% on ammonia, formaldehyde and acetic acid. It seems to the odor treatment efficiency depends on the applied voltage, temperature, humidity and chemical bonding of odors.

Preferential Killing of Human Lung Cancer Cell Lines with Mitochondrial Dysfunction by Non-Thermal Dbd Plasma

  • Panngom, Kamonporn;Baik, Ku Youn;Nam, Min-Kyung;Rhim, Hyang-Shuk;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.199-199
    • /
    • 2013
  • The distinctive cellular and mitochondrial dysfunctions of a human epithelial lung cancer cell line (H460) from a human lung fibroblastic normal cell line (MRC5) have been studied by dielectric barrier discharge (DBD) plasma treatment. The DBD plasma device have generated large amount of H2O2 and NOx in culture media which is dependent on plasma exposure time. It is found that the cell number of lung cancer cell H460 has been reduced more than the lung normal cell MRC5 as being increased exposure and incubation time. Also these both cell lines have showed mitochondria fragmentation under 5 minutes' plasma exposure, which is a clue of apoptosis. It is noted in this study that AnnexinV staining has showed not only early apoptosis, but also late apoptosis in lung cancer cell H460. Mitochondria enzyme activity and ATP generation have been also much reduced in lung cancer cell H460. Their mitochondrial membrane potential (${\Delta}{\psi}m$) has been found to be reduced in magnitude and shifted to the induced-potential level of cccp, while MRC5 mitochondrial membrane potential has been shifted slightly to that. These distinctively selective responses of lung cancer cell H460 from lung normal cell MRC5 gives us possibility of applying plasma to cancer therapy.

  • PDF