• Title/Summary/Keyword: DAA

Search Result 84, Processing Time 0.026 seconds

Design of a Mobile DAA Model through Java Test Module for the DAA Protocol (DAA 자바 실험모듈 구현을 통한 모바일 DAA 모델 설계)

  • Yang, Seok-Hwan;Lee, Ki-Yeal;Chung, Mok-Dong
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.8
    • /
    • pp.773-777
    • /
    • 2008
  • Today's mobile devices have characteristic of random mobility in the heterogeneous networks. Thus they should have various kinds of security requirements. To satisfy these requirements, there are many researches on security and authentication for mobile devices. TCG(Trusted Computing Group) designed TPM(Trusted Platform Module) for providing privacy and authentication to users. Also TCG suggest a protocol, called DAA(Direct Anonymous Attestation) which uses zero knowledge proof theory. In this paper, we will implement DAA protocol using Java and show the efficiency and the problems in the DAA protocol. Finally, we will suggest an efficient mobile DAA model through Java test module for the DAA protocol.

Confidentiality Service Scheme Extending the DAA on HTTP Environment (HTTP환경에서 DAA를 이용한 비밀성 보안서비스 지원 방안)

  • 조인준;정희경;송기평;이준섭;구경철
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.11a
    • /
    • pp.305-311
    • /
    • 1999
  • IETF(Internet Engineering Task Force) RFC 2069 recommend to accept the DAA(Digest Access Authentication) scheme ill the HTTP 1.1(Hype. Text Transfer Protocol 1.1). When the client want to access the protected URI resources with Web Server, the BAA scheme is not considered to be a secure method of user authentication, as the user name and password are passed over the network as clear text. But, The DAA scheme is proposed to create a access authentication method which avoids the serious flaws of BAA(ie, passed over the network as clear text). The flaw of DAA is not supported the confidentiality services between client and server. This paper is proposed a confidentiality service scheme for HTTP environment, as an extension to DAA

  • PDF

A Performance Evaluation of MB-OFDM UWB System Considering the Domestic DAA Regulation (국내 DAA 기술 기준을 고려한 MB-OFDM UWB 성능 평가)

  • Shin, Cheol-Ho;Choi, Sang-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.9
    • /
    • pp.1000-1009
    • /
    • 2008
  • The purpose of this paper is to analyze the performance of MB-OFDM UWB system when the interference signal that can be WIMAX signal or 4 G system signal is received by detection limit of -80 dBm/MHz proposed in Korea for DAA(Detect And Avoid) to permit UWB in $3.1{\sim}4.8$ GHz. MB-OFDM UWB system supports two transmission modes; one is TFI(Time frequency Interleaving) mode that transmits OFDM symbols using different carrier frequency from symbol to symbol according to Time Frequency(TF) codes, the other is FFI(Fixed Frequency Interleaving) mode that transmits OFDM symbols using a specific carrier frequency. In this paper, we considered the TX average power and the synchronization structure to reflect the effect of frequency hopping according to TFC. Interference analysis results show that the WiMAX system is fenced thoroughly from UWB interference in domestic DAA regulation, but the performance of MB-OFDM UWB system is degraded seriously by an interference signal with the DAA detection limit even in frequency Hopping mode that can get frequency diversity effect.

Comparison of the Outcomes after Primary Total Hip Arthroplasty Using a Short Stem between the Modified Anterolateral Approach and Direct Anterior Approach with a Standard Operation Table (일반 수술 침대와 짧은 대퇴 주대를 이용한 인공 고관절 전 치환술의 직접 전방 도달법과 변형된 전 측방 도달법에 따른 결과 비교)

  • Park, Myung-Sik;Yoon, Sun-Jung;Choi, Seung-Min;Cho, Hong-Man;Chung, Woochull;Kang, Kyung-Rok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.244-253
    • /
    • 2019
  • Purpose: Total hip arthroplasty was performed using a direct anterior approach (DAA) on an ordinary operation table and a short femoral stem. The clinical radiographic results were evaluated by a comparison with those performed using the modified hardinge (anterolateral approach, ALA) method. Materials and Methods: From January 2013 to November 2015, 102 patients who underwent total hip arthroplasty using DAA (DAA group) and the same number of patients using ALA (ALA group), both performed by a single surgeon, were compared and analyzed retrospectively. The operation time and amounts of bleeding were compared, and the improvement in post-operative pain, ambulatory capacity and functional recovery of the hip joint were checked. The location of insertion of the acetabular cup and femoral stem were evaluated radiologically, and the complications that occurred in the two groups were investigated. Results: The amount of bleeding was significantly smaller in the DAA group (p=0.018). Up to 3 weeks postoperatively, recovery of hip muscle strength was significantly higher in the DAA group (flexion/extension strength p=0.023, abduction strength p=0.031). The Harris hip score was significantly better in the DAA group for up to 3 months (p<0.001) and the Koval score showed significantly better results in the DAA group up to 6 weeks (p≤0.001). The visual analogue scale score improvement was significantly higher in the DAA group by day 7 (p=0.035). The inclination angle (p<0.001) and anteversion angle (p<0.001) of the acetabular cup were located in the safe zone of the DAA group more than in the ALA group, and there was no statistically significant difference in the position of the femur stem and leg length difference. During surgery, two cases of greater trochanter fracture occurred in the DAA group (p=0.155). Conclusion: The DAA performed in the ordinary operation table using a short femoral stem showed post-operative early functional recovery. Because a simple to use fluoroscope was used during surgery with an anatomical position familiar to the surgeon, it is considered to be useful for the insertion of implants into the desired position and for an approach that is useful for the prevention of leg length differences.

Transitioning from the Posterior Approach to the Direct Anterior Approach for Total Hip Arthroplasty

  • Cameron M. Metzger;Hassan Farooq;Jacqueline O. Hur;John Hur
    • Hip & pelvis
    • /
    • v.34 no.4
    • /
    • pp.203-210
    • /
    • 2022
  • Purpose: Total hip arthroplasty (THA) using the direct anterior approach (DAA) is known to have a learning curve. The purpose of this study was to review cases where surgery was performed by an arthroplasty surgeon transitioning from the posterior approach (PA) to the DAA. We hypothesized similar complication rates and improvements in surgical duration over time. Materials and Methods: A review of 2,452 consecutive primary THAs was conducted. Surgical duration, length of stay (LOS), surgical complications, decrease in postoperative day (POD) 1 hemoglobin, transfusion rates, POD 0 and POD 1 pain scores, incision length, leg length discrepancy (LLD), and radiographic cup position were recorded. Results: No differences in surgical duration were observed after the first 50 DAA cases. A shorter LOS was observed for the DAA, and statistical difference was appreciated after the first 100 DAA cases. There were no differences in periprosthetic fractures. A higher rate of infections and hip dislocations were observed with the PA. The PA showed an association with higher transfusion rates without significant difference in POD 1 decrease in hemoglobin over the first 100 DAA cases. Similar POD 0 and POD 1 pain scores with a smaller incision were observed for the first 100 DAA cases. The DAA cohort showed less variation in cup inclination, version, and LLD. Conclusion: DAA is safe and non-inferior in terms of reduced LOS, smaller incision, and less variation in cup position. Fifty DAA cases was noted to be the learning curve required before no differences in duration between approaches were observed.

Improvement of Ultra-wideband Link Performance over Bands Requiring Interference Mitigation in Korea

  • Rateb, Ahmad M.;Syed-Yusof, Syarifah Kamilah;Fisal, Norsheila
    • ETRI Journal
    • /
    • v.32 no.1
    • /
    • pp.44-52
    • /
    • 2010
  • Ultra-wideband (UWB) systems have witnessed a debate over whether they may cause interference to other existing and future narrowband systems sharing their band of operation. The detect and avoid (DAA) mechanism was developed as a solution to reduce interference to narrowband systems in order to ease regulatory concerns. It works by adaptively reducing the transmitted power at the overlapping bands upon detecting an active narrowband link. However, employing DAA degrades the performance of UWB transmissions. In this paper, we present the Korean UWB regulations as an example of regulations that require DAA in certain bands. We investigate DAA's impact on performance and propose a method to mitigate it, which provides UWB with the more efficient support of the DAA mechanism and enables it to avoid a larger number of narrowband users while sustaining the data rate. Results show significant improvement in performance with the application of our technique compared to conventional performance.

Establishment of Days after Anthesis(DAA) and Fruit After-ripening Period(FAP) for High-Quality Seed Production of Watermelon (우량 수박종자 생산을 위한 적정 성숙일수 및 후숙일수 확립)

  • Park, Eun-Ji;Lee, Gyu-Bin;Park, Young-Gil;Suh, Jeong-Min;Kang, Jum-Soon
    • Journal of Environmental Science International
    • /
    • v.24 no.12
    • /
    • pp.1681-1689
    • /
    • 2015
  • This study was conducted to investigate days after anthesis (DAA) and fruit after-ripening period (FAP) for seed-harvesting of high quality watermelon seeds. Fruit weight and number of seed per fruit increased according to DAA, while those did not significant about FAP. Ratio of cotyledon at whole seed was higher about 2 to 4% compared to seed coat irrespective of DAA and FAP. Germinability of watermelon was not a significant effect by DAA, however, it had differences by FAP. Percent of germination (PB) was below 50%, when 30 days maturated fruits after anthesis was omitted ripening, while PB was increased to 92% by ripening. In addition, seeds at DAA 40 and FAP 20 were higher general seedling vigors (hypocotyl length, diameter etc.) in BP test. Results indicated that considering seed productivity, it had maximized seed viability at DAA 40 and FAP 20.

A Comparative Study of Bipolar Hemiarthroplasty for Intertrochanteric Fracture: Direct Anterior Approach versus Conventional Posterolateral Approach

  • Young Yool Chung;Seung-Woo Shim;Min Young Kim;Young-Jae Kim
    • Hip & pelvis
    • /
    • v.35 no.4
    • /
    • pp.246-252
    • /
    • 2023
  • Purpose: The aim of this study was to compare short-term results from use of the direct anterior approach (DAA) and the conventional posterolateral approach (PLA) in performance of bipolar hemiarthroplasty for treatment of femoral intertrochanteric fractures in elderly patients. Materials and Methods: A retrospective review of 100 patients with intertrochanteric fractures who underwent bipolar hemiarthroplasty was conducted. The PLA was used in 50 cases from 2016 to 2019; since that time we have used the DAA in 50 cases from 2019 to 2021. Measurements of mean operative time, blood loss, hospitalization period, and ambulation status, greater trochanter (GT) migration and stem subsidence were performed. And the incidence of complications was examined. Results: Operative time was 73.60±14.56 minutes in the PLA group and 79.80±8.89 minutes in the DAA group (P<0.05). However, after experiencing 20 cases using DAA, there was no statistically difference in operative time between two groups (P=0.331). Blood loss was 380.76±180.67 mL in the PLA group and 318.14± 138.51 mL in the DAA group (P<0.05). The hospitalization was 23.76±11.89 days in the PLA group and 21.45 ±4.18 days in the DAA group (P=0.207). In both groups, there were no progressive GT migration, intraoperative fractures or dislocations, although there was one case of infection in the PLA group. Conclusion: Although use of the DAA in performance of bipolar hemiarthroplasty required slightly more time in the beginning compared with the PLA, the DAA may well be an alternative, safe surgical technique as a muscle preserving procedure in elderly patients with intertrochanteric fractures.

A Detection Algorithm Study of the Victim Signal for the DAA Regulation in MB-OFDM UWB System (MB-OFDM UWB 시스템에서 DAA 기술 기준 적용을 위한 피 간섭 신호 검출 방안 연구)

  • Shin, Cheol-Ho;Choi, Sang-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.12
    • /
    • pp.1297-1307
    • /
    • 2009
  • The purpose of this paper is to propose a detection algorithm and a tracking algorithm based on silent time using MB-OFDM UWB(Multi-Band Orthogonal Frequency Division Multiplexing Ultra Wide Band) receiver in order to satisfy DAA(Detect And Avoid) regulation of Korea to permit UWB in 3.1~4.8 GHz. In DAA regulation of Korea, if UWB device receives a signal more than -80 dBm/MHz from the victim system during UWB operation, the UWB system should avoid the collision within 2 sec. In this paper, we proposed the detection algorithm to detect the victim signal received by -80 dBm/MHz for the avoidance process that changes the operating UWB frequency to other UWB frequency and the subcarrier tracking algorithm to follow up the subcarrier positions of the victim signal for the tonenulling avoidance process that decreases the TX power of subcarriers occupied by the victim signal by -70 dBm/MHz. The performance of the detection algorithm and the tracking algorithm suggested in this paper is verified in simulation results considering various conditions.

Detection algorithm for DAA using Decision Directed method in MB-OFDM (MB-OFDM에서 충돌회피를 위한 결정궤환방식의 간섭신호 검출 기법)

  • Oh, Woo-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.2
    • /
    • pp.315-321
    • /
    • 2011
  • Since the MB-OFDM(Multi-Band Orthogonal Frequency Division Multiplexing) is an ultra wideband communication system operated on ISM(Industrial, Scientific and Medical) band, DAA(Detect-And-Avoid) is required for co-existence with the other communication service. In this paper we propose the new detection algorithm based on decision-feedback, which shows faster convergence time and less complexity than previous works. The proposed algorithm detects interference above -20dB in AWGN(Additive White Gaussian Noise) and LOS(Line-Of-Sight) channel, and close to AWGN in non-LOS channel under appropriate channel clipping.