• Title/Summary/Keyword: D-Tube

Search Result 1,294, Processing Time 0.028 seconds

A Study of Legal Status of Artificial Insemination Child (인공수정자의 법적 지위에 관한 연구)

  • Kim, JI Yeon
    • The Korean Society of Law and Medicine
    • /
    • v.16 no.1
    • /
    • pp.83-124
    • /
    • 2015
  • Currently, infertility and artificial insemination have increased. However, there is no detailed legislation about this. In this study, I'll consider the legal status of artificial insemination child. Through the examination of the overseas legislation, we may get the reference of the future legislation. If we consider the increasing of infertility, artificial insemination should be allowed. And due to the well-being of artificial insemination child, such as the United States and France, the artificial insemination child should be regarded the legal child of the infertile couples. When the contradiction between the subject's basic rights has occurred, we need to consider the welfare of the child preferentially. Because the artificial insemination child has no selection of opportunity in birth, unlike adults who select the artificial insemination in their own free will. The development of biotechnology should be for the treatment of human. But creation and improvement of human must be prohibited. In addition, the social investigation of recognition about A.R.T. and general public administrative legal regulation should be made. There is a need for balanced discipline through a multi-disciplinary research. This study may be providing a legal interpretation criteria of other biotechnology researches.

  • PDF

A Prospective Study for Risk Factors Predicting Postoperative Pulmonary Complications (수술 후 폐 합병증 발생의 위험 인자에 대한 연구)

  • Chon, Su Yeon;Kim, Yu Jin;Kyung, Sun Young;Ahn, Chang Hyeok;Lee, Sang Pyo;Park, Jeong Woong;Jeong, Sung Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.6
    • /
    • pp.516-522
    • /
    • 2007
  • Background: Postoperative pulmonary complications are important problems that prolong the length of the hospital stay and increase patient mortality. However, our knowledge of the postoperative factors that increase the risk of these complications is less than complete. Methods: We conducted a prospective study to determine the risk factors for postoperative pulmonary complications. A total of 199 patients were referred to the Pulmonology Department for preoperative pulmonary evaluation. We reviewed the perioperative variables according to the National Surgical Quality Improvement Program (NSQIP). Postoperatively, we collected data on the occurrence of postoperative pulmonary complications and we evaluated the relationship between the perioperative variables and outcomes. Results: Twenty two patients (11%) had pulmonary complications; 6 had respiratory failure, 4 had pneumonia, 13 had pleural effusion and, 2 had atelectasis. Five variables were statistically significantly associated with pulmonary complications on the bivariate analyses. Multiple logistic regression analyses revealed that three of these variables were independently associated with an increased risk of pulmonary complications; a high cardiac risk index (OR 16.5, p=0.002), emergency surgery (OR 10.3, p=0.017), and thoracic/abdominal surgery (OR 3.8, p=0.047). Conclusion: The risk factors for postoperative pulmonary complications are a high cardiac risk index, emergency surgery and thoracic/abdominal surgery.

Determination of Volatile Organic Compounds emitted from Municipal Solid Waste Landfill Site by Thermal Desorption-Cryofocusing-GC/FID/FPD (열탈착-저온농축-GC/FID/FPD에 의한 도시 생활폐기물 매립장에서 방출되는 휘발성 유기화합물의 측정에 관한 연구)

  • Kim, Man-Goo;Jung, Young-Rim;Seo, Young-Min;Nam, Sung-Hyun;Kwon, Young-Jin
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.274-285
    • /
    • 2001
  • In this study, the thermal desorption-cryofocusing-gas chromatographic(TD-C-GC) method was developed for determination of volatile organic compounds(VOCs) in ambient air and was applied at the municipal solid waste landfill sites. On-column cryofocusing was possible only with a 100 ml dewars bottle in TD-C-GC method with a stainless steel column. However, high operating pressure was needed for purging VOCs from the absorbent trap, which was able to solve by pressure programming with a electric pressure controller. By using both pressure and temperature programming brought increasing of resolution power in on-column cryofocusing method, but the high pressure caused a leakage of sample tube with repeated use. A loop cryofocusing devise was also developed and compared with the direct on-column method. In loop cryofocusing method, VOCs were concentrated on a 0.8mm i.d. loop which is located between the injector and separation column by using liquid nitrogen. In order to purge VOCs from the absorbent trap, only 0.4 psi of pressure was need in the loop cryofocusing method. Dual detection system was applied for the analysis of VOCs; a FID was used for hydrocarbons and a FPD was used for sulfur-containing compounds. Qualitative analysis was done by on-column cryofocusing GC-MS system. Among the large number of VOCs, toluene was the most abundant. Hydrogen sulfide, dimethyl sulfide, carbon disulfide, dimethyl disulfide and methyl propyl disulfide were detected at landfill site by FPD.

  • PDF

Conditions for Stable light Production of Recombinant Escherichia coli Containing Lux Operon and Sensitivity to Toxic Chemicals (Lux operon을 함유한 유전자 재조합 Escherichia coli의 발광 안정화 조건 및 독성물질에 대한 민감성)

  • 배희경;이상민;정윤철;송방호;신평균
    • KSBB Journal
    • /
    • v.17 no.6
    • /
    • pp.571-576
    • /
    • 2002
  • Recombinant E. coli DH5 ${\alpha}$/pSB311 was made by cloning the genes encoding bacterial luciferase and aldehyde substrate proteins from Photohabdus luminescense, to complement defects of Lumistox, which is normally used in bioassays to monitor toxic substances in water environmental systems. The conditions for stable light production by the recombinant strains were investigated with respect to cell growth stage, cell number, and buffer conditions. The optimum growth stage was a middle-exponential stage with an OD$_{660nm}$ value of 0.6-0.7. ADout 10$^{6}$-10$^{7}$ cells per test tube was optimum for stable light emission. The effect of buffer was not significant if an optimum viable cell number was maintained. The bioluminescence of the recombinant E. coli harboring the lux operon of Photohabdus luminescense was not affected by temperature, while the bioluminescence of Lumistox was temperature sensitive. The recombinant E. coli was more sensitive to heavy metals (Cd, Cu, Hg, Zn) than Lumistox, because it does not require high concentrations of NaCl in the buffer.

Radiation Damage of Semiconductor Device by X-ray (엑스선에 의한 반도체 소자의 방사선 손상)

  • Kim, D.S.;Hong, H.S.;Park, H.M.;Kim, J.H.;Joo, K.S.
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.110-117
    • /
    • 2015
  • Recently, Due to the increased industry using radiation inspection equipment in the semiconductor, this demand of technology research is increasing. Although semiconductor inspection equipment is using low energy X-ray from 40 keV to 120 keV, Studies of radiation damage about the low energy X-ray are lacking circumstance in our country. Therefore, It is study that BJT (bipolar junction transistor) of one type of semiconductor elements are received radiation damage by low energy X-ray. BJT were used to the NXP semiconductor company's BC817-25 (NPN type), and Used the X-ray generator for the irradiation. Radiation damage of BJT was evaluated that confirm to analyse change of collector-emitter voltage of before and after X-ray irradiation when current gain fixed to 10. X-ray generator of tube voltage was setting 40 kVp, 60 kVp, 80 kVp, 100 kVp, 120 kVp and irradiation time was setting 180s, 360s, 540s into 180s intervals. As the result, We confirmed radiation damage in BJT by low energy X-ray under 120 keV energy, and Especially the biggest radiation damage was appeared at the 80 kVp. It is expected that ELDRS (enhanced low dose rate sensitivity) phenomenon occurs on the basis of 80 kVp. This studies expect to contribute effective dose administration of semiconductor inspection equipment using low energy X-ray, Also Research and Development of X-ray filter.

A Comparative study on Perceived Importance and Frequency of Core Nursing Skills between General and Special wards (일반병동과 특수병동의 핵심기본간호술에 대한 중요성인식과 수행 빈도 비교)

  • Chang, Eun-Hee;Mo, Moon-Hee;Choi, Eun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1264-1272
    • /
    • 2015
  • This study was performed to compare the perceived importance and performance frequency of the core nursing skills between general and special department. Subjects were 182 nurses who work on the hospital. Data was collected using items made by Korean accreditation board of nursing education and analyzed by frequency, mean and t-test. There were differences of importance and frequencies about nursing core skill between general and special wards. Core nursing skills of general wards were higher importance on intradermal injection(p=.011), transfusion(p=.028), simple catheterization(p=.047), cleansing enema(p=<.001), preoperative and postoperative care(p=.035), management administration(p=.027) and oxygenation with cannular(p=.002) than special wards. Actual performance frequency core nursing skills of general wards were higher similar on transfusion(p=.002), intermittent tube feeding(p=.032), simple catheterization(p=<.001), cleansing enema(p=<.001), preoperative care(p=.001), postoperative care(p=<.001), management administration(p=.001), protection equipment for quarantine room and waste disposal(p=.021), oxygenation with cannular(p=<.001) than special wards. It is needed to develop efficient and sequential program to learning the nursing core skills for nursing students.

Fabrication of ZrO2 Nano Tube by Atomic Layer Deposition with Exposure Time Control System (전구체 노출 시간을 조절하는 원자층 증착기술에 의한 ZrO2 나노 튜브 제조)

  • Shin, Woong-Chul;Ryu, Sang-Ouk;Seong, Nak-Jin;Yoon, Soon-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.39-39
    • /
    • 2007
  • 원자층 증착(Atomic Layer Deposition: ALD) 방법은 반응물질들을 펄스형태로 챔버에 공급하여 기판표면에 반응물질의 표면 포화반응에 의한 화학적 흡착과 탈착을 이용한 박막증착기술이다. ALD법은 기존의 화학적 기상증착(Chemical Vapor Deposition: CVD)과 달리 자기 제한적 반응(self-limiting reaction) 에 의하여 반응가스가 기판 표면에서만 반응하고 가스와 가스 간에는 반응하지 않는다. 따라서 박막의 조성 정밀제어가 쉽고, 파티클 발생이 없으며, 대면적의 박막 증착시 균일성이 우수하고, 박막 두께의 정밀 조절이 용이한 장점이 있다. 이러한 ALD 방식으로 3차원의 반도체 장치 구조물에 산화막 등을 형성하는 공정에서 중요한 요소 중의 하나는 전구체의 충분한 공급이다. 따라서 증기압이 높은 전구체를 선호하는 경향이 있다. 그러나 증기압이 낮은 전구체를 사용할 경우, 공급량이 부족하여 단차 도포성(step coverage)이 떨어지는 문제가 있다. 원자층 증착 공정에서 전구체를 충분히 공급하기 위해전구체 온도를 증가시키거나 전구체의 공급시간을 늘리는 방법을 사용한다. 그러나 전구체 온도를 상승시키는 경우, 전구체의 변질이나 수명을 단축시키는 문제점을 발생시킬 수 있으며. 전구체를 충분히 공급하기 위하여 전구체의 공급시간을 늘이는 방법을 사용하면, 원하는 박막을 형성하기 위하여 소요되는 공정시간과 전구체 사용량이 증가된다. 본 논문에서는 이러한 문제점을 해결하기 위해 반응기 안에서 전구체 노출 시간을 조절하는 새로운 ALD 공정을 소개한다. 특히 이러한 기술을 적용하면 나노튜브를 성장시키는데 매우 유리하다. 본 연구에서 전구체 노출 시간을 조절하기 위하여 사용된 ALD 장비는 Lucida-D200-PL (NCD Technology사)이며 (TEMA)Zr와 H2O를 사용하여 ZrO2 나노튜브를 폴리카보네이트 위에 성장시켰다. 전구체의 노출 시간은 반응기의 Stop 밸브를 이용하여 조절하였으며, SEM, TEM 등을 이용하여 나노튜브의 균일성과 단차피복성 등의 특성을 관찰하였다. 그 결과 전구체 노출시간을 조절함으로써 높은 종횡비를 갖는 나노튜브를 성장 시킬 수 있음을 확인하였다. 또한 낮은 증기압을 가지는 전구체를 이용하여도 우수한 특성의 나노튜브를 균일하게 성장시킬 수 있었다.

  • PDF

A Study on the Image Quality of Mammography and the Average Glandular Dose (맘모그래피의 화질과 평균유선조직선량에 관한 검토)

  • Lee, In-Ja;Kim, Hak-Sung;Kim, Sung-Soo;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.25 no.2
    • /
    • pp.47-55
    • /
    • 2002
  • We came to the following conclusion as the results of experiment on the image quality of mammography and the average glandular dose using 4 apparatuses at 3 hospitals in Seoul. 1. Whereas the measurement of half value layer showed no differences among the apparatuses, the measurement by an attenuation curve method showed some differences by 5.9%. There were 9.1% differences in the measurement by aluminum conversion method. 2. The basic density of an automatic exposure control unit must be D = 1.40, but there was no automatic exposure unit adjusted precisely at any hospitals. The unit at the B hospital exceeded the allowable limit by ${\pm}0.15$. 3. In the photographing using an automatic exposure control unit and the management of an automatic film processor using a sensitometer, most automatic film processors were well kept. But in some cases the mean value of a fluctuation coefficient exceeded the allowable limit. There is a need for more cautious management. 4. The image quality of breast phantom photography was affected by the screen/film system among the hospitals. 5. The average glandular dose at a breast of 4.2 cm thickness depended on the tube voltage, In the case of Mo/Mo, it was measured $0.26{\sim}1.39\;mGy$ less than ACR standard 3.0 mGy.

  • PDF

A Study on Removal Efficiency of VOCs using Vortex Cyclones (보텍스 사이클론을 이용한 VOCs 제거효율에 관한 연구)

  • Lim, Gye-Gyu
    • Applied Chemistry for Engineering
    • /
    • v.16 no.2
    • /
    • pp.194-199
    • /
    • 2005
  • The principle of vortex cyclone was applied to enhance the treatment efficiency of waste air streams containing particulate matters, phenol, and others. Adsorption, condensation, and/or coagulation could be induced at low temperature zone formed by Joule-Thomson expansion as the pressurized air and pulverized activated carbon were introduced at the tangential direction into the cyclone system applied with the coaxial funnel tube of vortex cyclone. Easily condensible vapors were adsorbed and/or condensed forcibly on coagulated or condensed materials which were formed as cores for coagulation or condensation by themselves or on pulverized activated carbons. These types of coagulation or condensation rates were rapidly promoted by increase in their diameter. The maximum removal efficiency obtained from this experiment for the removal of carbon dioxide and phenol was about 87.3 and 93.8 percent, respectively. Phenol removal efficiency was increased with the relative humidities and enhanced by pulverized activated carbon added. The Joule-Thomson coefficients were increased with the pressure of air injected in the range of the relative humidities between 10% and 50%. It is believed that the moisture, particulate matters, and the pressure of the process air introduced could control the removal efficiency of VOCs.

Simulation of the effect of inclusions length and angle on the failure behavior of concrete structure under 3D compressive test: Experimental test and numerical simulation

  • Mohammad Saeed, Amini;Vahab, Sarfarazi;Kaveh, Asgari;Xiao, Wang;Mojtaba Moheb, Hoori
    • Steel and Composite Structures
    • /
    • v.46 no.1
    • /
    • pp.53-73
    • /
    • 2023
  • Man-made structure materials like concrete usually contain inclusions. These inclusions affect the mechanical properties of concrete. In this investigation, the influence of inclusion length and inclination angle on three-dimensional failure mechanism of concrete under uniaxial compression were performed using experimental test and numerical simulation. Approach of acoustic emission were jointly used to analyze the damage and fracture process. Besides, by combining the stress-strain behavior, quantitative determination of the thresholds of crack stress were done. concrete specimens with dimensions of 120 mm × 150 mm × 100 mm were provided. One and two holes filled by gypsum are incorporated in concrete samples. To build the inclusion, firstly cylinder steel tube was pre-inserting into the concrete and removing them after the initial hardening of the specimen. Secondly, the gypsum was poured into the holes. Tensile strengths of concrete and gypsum were 2.45 MPa and 1.5 MPa, respectively. The angle bertween inclusions and axial loadind ary from 0 to 90 with increases of 30. The length of inclusion vary from 25 mm to 100 mm with increases of 25 mm. Diameter of the hole was 20 mm. Entirely 20 various models were examined under uniaxial test. Simultaneous with experimental tests, numerical simulation (Particle flow code in two dimension) were carried out on the numerical models containing the inclusions. The numerical model were calibrated firstly by experimental outputs and then failure behavior of models containing inclusions have been investigated. The angle bertween inclusions and axial loadind vary from 0 to 90 with increases of 15. The length of inclusion vary from 25 mm to 100 mm with increases of 25 mm. Entirely 32 various models were examined under uniaxial test. Loading rate was 0.05 mm/sec. The results indicated that when inclusion has occupied 100% of sample thickness, two tensile cracks originated from boundaries of sample and spread parallel to the loading direction until being integrated together. When inclusion has occupied 75% of sample thickness, four tensile cracks originated from boundaries of sample and spread parallel to the loading direction until being integrated together. When inclusions have occupied 50% and 25% of sample thickness, four tensile cracks originated from boundaries of sample and spread parallel to the loading direction until being integrated together. Also the inclusion was failed by one tensile crack. The compressive strength of samples decease with the decreases of the inclusions length, and inclusion angle had some effects on that. Failure of concrete is mostly due to the tensile crack. The behavior of crack, was affected by the inclusion length and inclusion number.