• Title/Summary/Keyword: D 002

Search Result 492, Processing Time 0.03 seconds

Improvement of Corrosion Resistance and Nano-hardness of Ti-Al-N Deposit Formed by Arc Ion Plating (아크 이온 증착된 TiAlN 도포층의 내식성과 나노 경도 개선)

  • Gang, Bo-Gyeong;Choe, Yong;Gwon, Sik-Cheol;Zang, Shi-Hong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.213-213
    • /
    • 2014
  • $300^{\circ}C$$500^{\circ}C$에서 아크 이온 증착된 도포층의 조성은 각각 Fe : Al : Ti : Si : N = 1.31 : 36.52 : 31.31 : 0.48 : 30.38 [wt.%]와 Fe : Cr : Al : Ti : Si : N = 1.24 : 0.56 : 36.82 : 32.72 : 0.59 : 28.07 [wt.%] 이었다. 0.1N $H_2SO_4$ 수용액과 인공해수 (ASTM D1141-98) 분위기에서 $300^{\circ}C$, $500^{\circ}C$에서 증착된 도포층의 부식전압과 부식속도는 각각 $-0.2787V_{SHE}$, $0.002A/cm^2$, $-2.764V_{SHE}$, $0.002A/cm^2$$-0.2799V_{SHE}$, $0.002A/cm^2$, $-0.0394V_{SHE}$, $0.002A/cm^2$이었다. 나노 경도값은 각각 23.6, 25.8 GPa 이었다. 이는 각각 2208.2, $2434.2H_V$에 해당되었다.

  • PDF

Effectiveness of Simulation Prctice Education on Emergency Using Debriefing for Meaningful Learning of Nursing Student (간호대학생의 DML(Debriefing for Meaning Learning)를 적용한 응급 시뮬레이션 실습의 효과)

  • Kim, So-Myeong;Kim, Su-Ol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.6
    • /
    • pp.1577-1586
    • /
    • 2021
  • The purpose of this study was to evaluate the effects of debriefing for meaning learning on critical thinking ability, problem-solving ability, communication abilit of nursing students. A nonequivalent control group pretest-posttest design was used in this study. And the subjects were 73 students in D city, including 38 students in experimental group and 35 students in control group. The result critical thinking ability (t=-3.144, p=.002), problem-solving ability (t=-3.248, p=.002), and critical communication ability (t=-4.051, p=<.001) improved more significantly in the experimental group, compared with the control group. Therefor debriefing for meaning learning on nursing students' was effective education method on critical thinking skills, problem-solving skills, communication skills.

A Study on the Effect of O$_2$ annealing on Structural, Optical, and Electrical Characteristics of Undoped ZnO Thin Films Deposited by Magnetron Sputtering (산소 어닐링이 마그네 트론 스퍼터링으로 증착된 undoped ZnO박막의 구조적, 광학적, 전기적 특성에 미치는 영향에 대한 연구)

  • Yun, Eui-Jung;Park, Hyeong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.7
    • /
    • pp.7-14
    • /
    • 2009
  • In this paper, the effects of annealing conditions on the structural ((002) intensity, FWHM, d-spacing, grain size, (002) peak position), optical (UV peak, UV peak position) and electrical properties (carrier concentrations, resistivity, mobility) of ZnO films were investigated. ZnO films were deposited onto SiO$_2$/si substrates by RF magnetron sputtering from a ZnO target. The substrate was not heated during deposition. ZnO films were annealed in temperature ranges of $500\sim650^{\circ}C$ in the O$_2$ flow for 5$\sim$20 min. The film average thicknesses were in the range of 291 nm. The surface morphologies and structures of the samples were characterize by SEM and XRD, respectively. The optical properties were evaluated by photoluminescence (PL) measurement at room temperature (RT) using a He-Cd 325 nm laser. As the annealing temperature and time vary, the following relations were also observed: (1) proportional relationships among UV intensity (002) intensity, and grain size exist, (2) UV intensity is inversely proportional to FWHM, (3) there is no special relationship between UV intensity and electron carrier concentrations, (4) d-spacing is inversely proportional to (002) peak position, (5) UV peak position in the range of 3.20$\sim$3.24 eV means that ZnO films have a n-type conductivity which was consistent with that obtained from the electrical property, (6) the optimal conditions for the best optical and structural characteristics were found to be oxygen fraction, (O$_2$/(O$_2$+Ar)) of 0.2, RF power of 240W, substrate temperature of RT, annealing condition of 600$^{\circ}C$ for 20 min, and sputtering pressure of 20 mTorr.

Marginal microleakage of cervical composite resin restorations bonded using etch-and-rinse and self-etch adhesives: two dimensional vs. three dimensional methods

  • Khoroushi, Maryam;Ehteshami, Ailin
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.2
    • /
    • pp.83-90
    • /
    • 2016
  • Objectives: This study was evaluated the marginal microleakage of two different adhesive systems before and after aging with two different dye penetration techniques. Materials and Methods: Class V cavities were prepared on the buccal and lingual surfaces of 48 human molars. Clearfil SE Bond and Single Bond (self-etching and etchand-rinse systems, respectively) were applied, each to half of the prepared cavities, which were restored with composite resin. Half of the specimens in each group underwent 10,000 cycles of thermocycling. Microleakage was evaluated using two dimensional (2D) and three dimensional (3D) dye penetration techniques separately for each half of each specimen. Data were analyzed with SPSS 11.5 (SPSS Inc.), using the Kruskal-Wallis and Mann-Whitney U tests (${\alpha}=0.05$). Results: The difference between the 2D and 3D microleakage evaluation techniques was significant at the occlusal margins of Single bond groups (p = 0.002). The differences between 2D and 3D microleakage evaluation techniques were significant at both the occlusal and cervical margins of Clearfil SE Bond groups (p = 0.017 and p = 0.002, respectively). The difference between the 2D and 3D techniques was significant at the occlusal margins of non-aged groups (p = 0.003). The difference between these two techniques was significant at the occlusal margins of the aged groups (p = 0.001). The Mann-Whitney test showed significant differences between the two techniques only at the occlusal margins in all specimens. Conclusions: Under the limitations of the present study, it can be concluded that the 3D technique has the capacity to detect occlusal microleakage more precisely than the 2D technique.

Effect of Ferrous Ion on the Formation of Exotoxin A from Pseudomonas sp. PY002 and Cloning of it's Gene (Pseudomonas sp. PY002에서 Exotoxin A의 생성에 미치는 철 이온의 영향과 Exotoxin A 유전자의 클로닝)

  • Choi, Sun-Ah;Kim, Ho-Sang;Choi, Ji-Young;Kang, Jeong-Suk;Kim, Chun-Sung;Kim, Duck-Lae;Kim, Young-Ju;Yeo, Myeong-Gu;Park, Yeol
    • Korean Journal of Microbiology
    • /
    • v.35 no.1
    • /
    • pp.7-12
    • /
    • 1999
  • By SDS-polyacrylamide gel elcctrophoresis (SDS-PAGE) and immunoblot analysis that a protein with 66,000 daltons in size was recognized by P. aeruginosa anti-exotoxin A from P. sp. PY002. The yields of exotoxin A in P. sp. PY002 culture were influenced by the concentration of iron in the culture media. Increasing of the exotoxin A production and siderophore production was made slight increasing in the MKB medium. On the other hand, to clone the gene encoding the exoloxin A genomic library of P. sp. PY002 was constructed in pBluescript SK(+). From this library a exotoxin A homologous gene was isolated by immunological hybridization method using P. aemginosa anti-exoloxin A as a probe. Two putative clones were isolated and designated pETA23 and pETA42. Thc restriction analysis ol pETA42 demonstrated that thc 1760 bp insert contained one NcoI, PvuII, SstI, Kpnl and EcoRI site and three SmaI and HaeD sites.

  • PDF

Cross-Borehole Incoherent Tomography for High-Contrast Cylindrical Cavity in Lossy Medium by Using Single-Frequency Time-Harmonic Signal (단일 주파수 시간조화 신호를 사용한 손실 매질내에 있는 high-contrast 원기둥 공동의 cross-borehole incoherent 단면영상법)

  • 강진섭
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.11
    • /
    • pp.1-9
    • /
    • 1998
  • In this paper, an incoherent imaging of a high-contrast cylindrical cavity in a lossy medium illuminated by the time-harmonic cylindrical wave is obtained via the backprojections of the intensity patterns of the forward total electric field in the cross-borehole measurement configuration. The phenomenon that the interference fringes in the intensity pattern, which are caused by the superposition of the incident field and the scattered field with different optical paths, are removed in the backprojection process is interpreted numerically. This imaging method is validated by imaging an air circular cylinder in a lossy medium of $\varepsilon$$_{r}$=9 and $\sigma$ = 0.0005, 0.002 S/m, and the conditions for obtaining better images are investigated.d.

  • PDF

Microstrip Antenna using Multi-layer and Folded Structure for GPS Application (적층 폴디드 구조를 이용한 GPS용 마이크로스트립 안테나)

  • Keum, Jae-min;Woo, Jong-myung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.16 no.2
    • /
    • pp.171-179
    • /
    • 2017
  • In this paper, microstrip antenna using multi-layer and folded structure for GPS application is presented for aircraft loading. Existing microstrip patch antenna used dielectric of high specific inductive capacity to miniaturize that cause smaller bandwidth and decline of efficiency due to dielectric loss. To compensate the existing flaws, Rogers TMM 10i(dielectric constant=9.8, loss tangent=0.002) is used for multi-layer dielectric miniaturization, and we construct folded radiating element on the surface of the dielectric applying perturbation effect. The antenna is designed in the bandwidth of GPS $L_1$ band, and the size of the antenna's radiating element is $20.3mm{\times}19.93mm$, and it gets 94.2% miniaturized characteristic of basic ${\lambda}/2$ microstrip patch antenna. Also the measured -10 dB bandwidth is 32.3 MHz(2.05%), 3 dB axial ratio bandwidth is 6.7 MHz(0.43%). Measured radiation patterns was maximum gain of 0.56 dBi at x axis polarization, 1.23 dBi at y axis polarization.

Combination Therapy with a PI3K/mTOR Dual Inhibitor and Chloroquine Enhances Synergistic Apoptotic Cell Death in Epstein-Barr Virus-Infected Gastric Cancer Cells

  • Kim, Mi-Young;Kruger, Annie J.;Jeong, Ju-Yeon;Kim, Jaehee;Shin, Phil kyung;Kim, Sun Young;Cho, Joo Young;Hahm, Ki Baik;Hong, Sung Pyo
    • Molecules and Cells
    • /
    • v.42 no.6
    • /
    • pp.448-459
    • /
    • 2019
  • The phosphoinositide 3-kinase/protein kinase B/mammalian target of rapamycin (PI3K/AKT/mTOR) signaling pathway is a promising target for gastric cancer (GC) treatment; however the efficacy of PI3K/mTOR dual inhibitors in GC has not yet been maximized. Additionally, the effect of autophagy regulation by PI3K/mTOR dual inhibitors has not been clearly elucidated in GC treatment. We aimed to show that our newly developed PI3K/mTOR dual inhibitor, CMG002, when combined with an autophagy inhibitor, chloroquine (CQ), potently induces effective cancer cell death in Epstein-Barr virus (EBV)-associated gastric cancer (EBVaGC) cells, where both the PI3K/AKT/mTOR and autophagy pathways play important roles in disease pathogenesis. EBV- and mock-infected AGS and NUGC3 GC cell lines were treated with CMG002 +/- CQ. PI3K/AKT/mTOR signaling pathway mediators, cellular apoptosis and autophagy markers were confirmed by Western blot assay. Cell viability was assessed using the Cell Counting Kit-8 (CCK-8) assay. CMG002 effectively blocked the PI3K/AKT/mTOR pathway by markedly decreasing phosphorylation of AKT and its downstream mediator S6. CMG002 induced G0/G1 cell cycle arrest and enhanced apoptotic cell death in AGS and NUGC3 cells, particularly EBV-infected cells compared with mock-infected cells, as confirmed by flow cytometric analyses and TUNEL (terminal deoxynucleotidyl transferase dUTP nick end labeling) assays. The combination of CMG002 plus CQ synergistically increased apoptotic cell death in EBV-infected GC cell lines when compared with CMG002 alone (P < 0.05). Our results suggest that the new PI3K/mTOR dual inhibitor, CMG002, when used in combination with the autophagy inhibitor, CQ, provides enhanced therapeutic efficacy against EBVaGC.

X-ray diffraction analysis of the effect of ball milling time on crystallinity of milled polyacrylonitrile-based carbon fiber

  • Lee, Sang-Hye;Kang, Dong-Su;Lee, Sang-Min;Roh, Jae-Seung
    • Carbon letters
    • /
    • v.26
    • /
    • pp.11-17
    • /
    • 2018
  • Milled carbon fiber (mCF) was prepared by a ball milling process, and X-ray diffraction (XRD) diffractograms were obtained by a $2{\theta}$ continuous scanning analysis to study mCF crystallinity as a function of milling time. The raw material for the mCF was polyacrylonitrile-based carbon fiber (T700). As the milling time increased, the mean particle size of the mCF consistently decreased, reaching $1.826{\mu}m$ at a milling time of 18 h. The XRD analysis showed that, as the milling time increased, the fraction of the crystalline carbon decreased, while the fraction of the amorphous carbon increased. The (002) peak became asymmetric before and after milling as the left side of the peak showed an increasingly gentle slope. For analysis, the asymmetric (002) peak was deconvoluted into two peaks, less-developed crystalline carbon (LDCC) and more-developed crystalline carbon. In both peaks, Lc decreased and $d_{002}$ increased, but no significant change was observed after 6 h of milling time. In addition, the fraction of LDCC increased. As the milling continued, the mCF became more amorphous, possibly due to damage to the crystal lattices by the milling.

Effects of Substrate Temperature on the Properties Sputtered Fe Films Epitaxially Grown on Mgo(001) (기판온도가 MgO(001) 기판위에서 에피택시성장한 Fe스파터박막의 특성에 미치는 영향)

  • 김동우;장평우;김원태;유성초
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.4
    • /
    • pp.184-189
    • /
    • 1999
  • 1000 $\AA$ thick Fe films were epitaxially grown on MgO(001) by an rf sputtering and effects of substrate temperature on the structural and magnetic properties were investigated. X-ray diffraction intensity increased with increasing substrate temperature and inter-planar spacing $d_{(002)}$ decrease with increasing the temperature up to 25$0^{\circ}C$. The increased intensity and decreased inter-planar spacing were thought to be attributed to the enhancement of lattice match between Fe films and MgO, thus yielding good epitaxial growth. By using torque magnetometer, VSM and pole figure, very nice epitaxial growth of sputtered Fe films on MgO could be confirmed and $K_1$ value of Fe films grown at 25$0^{\circ}C$ was $4.6{\times}10^5\;erg/cc$, which was very similar to that of bulk single Fe crystal.

  • PDF