• Title/Summary/Keyword: D/d ratio

Search Result 9,670, Processing Time 0.036 seconds

Cavity-Backed Slot Array Antenna for a Repeater System of a Satellite Digital Multimedia Broadcasting (위성 DMB 중계기용 Cavity-Backed슬롯 배열 안테나)

  • Jung Hee-Chul;Lee Hak-Yong;Jung Byungwoon;Kang Gi-Cho;Park Myun-Joo;Lee Byungje
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.4 s.95
    • /
    • pp.366-372
    • /
    • 2005
  • This paper presents analysis of a slot array antenna having a low side lobe level and high front-to-back ratio for a repeater system of a satellite DMB(Digital Multimedia Broadcasting) service. Antennas for this repeater system require a high gain and enough isolation to reduce interferences between signals in system. Therefore, it is necessary to suppress a side lobe level and to increase front-to-back ratio. Unlike a structure 134 by lossy microstrip lines, in this work a single cavity-backed slot antenna array using a single waveguide feed is proposed to obtain the reliability for high power handling and high radiation efficiency. The side lobe level and front-to-back ratio are enhanced with tapered array technique and an optimized vertical reflector. The measured side lobe levels in H- and E-plane are under $-33.24\;\cal{dB}$ and $-35.78\;\cal{dB}$, respectively. The front-to-back ratio over $37.84\;\cal{dB}$, and the peak gain of over $17\;\cal{dBi}$ are measured.

The Evaluation of Image Quality in Gradient Echo MRI of the Pancreas : Comparison with 2D T1 FFE and 3D T1 THRIVE Imaging (췌장 경사자기장에코 자기공명영상에서 영상의 질 평가)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.2
    • /
    • pp.73-79
    • /
    • 2016
  • The purpose of this analysis is to compare 2D T1 FEE and 3D T1 THRIVE for demonstration of the pancreas. A total of 85(45 men, 40 women; 58 years) PACS network datum were analysis clinically indicated pancreas MRI at 1.5 T. The SNRs and CNRs of 3D T1 THRIVE(SNR: $46.42{\pm}0.67$, CNR: $28.16{\pm}0.50$) showed significantly higher values than those from 2D T1 FEE(SNR: $53.84{\pm}1.20$, CNR: $35.48{\pm}0.70$), p<0.05, The image quality of the 3D T1 THRIVE($2.63 {\pm}0.14$) was significantly superior to that with the 2D T1 FEE($2.2{\pm}0.05$), but 3D T1 THRIVE revealed several artifacts resulting in poor quality. In conclusion, The 3D T1 THRIVE technique with a 1.5 T resulting in improved SNRs, CNRs and image quality was demonstrated.

Effects of dietary forage-to-concentrate ratio on nutrient digestibility and enteric methane production in growing goats (Capra hircus hircus) and Sika deer (Cervus nippon hortulorum)

  • Na, Youngjun;Li, Dong Hua;Lee, Sang Rak
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.7
    • /
    • pp.967-972
    • /
    • 2017
  • Objective: Two experiments were conducted to determine the effects of forage-to-concentrate (F:C) ratio on the nutrient digestibility and enteric methane ($CH_4$) emission in growing goats and Sika deer. Methods: Three male growing goats (body weight $[BW]=19.0{\pm}0.7kg$) and three male growing deer ($BW=19.3{\pm}1.2kg$) were respectively allotted to a $3{\times}3$ Latin square design with an adaptation period of 7 d and a data collection period of 3 d. Respiration-metabolism chambers were used for measuring the enteric $CH_4$ emission. Treatments of low (25:75), moderate (50:50), and high (73:27) F:C ratios were given to both goats and Sika deer. Results: Dry matter (DM) and organic matter (OM) digestibility decreased linearly with increasing F:C ratio in both goats and Sika deer. In both goats and Sika deer, the $CH_4$ emissions expressed as g/d, g/kg $BW^{0.75}$, % of gross energy intake, g/kg DM intake (DMI), and g/kg OM intake (OMI) decreased linearly as the F:C ratio increased, however, the $CH_4$ emissions expressed as g/kg digested DMI and OMI were not affected by the F:C ratio. Eight equations were derived for predicting the enteric $CH_4$ emission from goats and Sika deer. For goat, equation 1 was found to be of the highest accuracy: $CH_4(g/d)=3.36+4.71{\times}DMI(kg/d)-0.0036{\times}neutral$ detergent fiber concentrate (NDFC,g/kg)+$0.01563{\times}dry$ matter digestibility (DMD,g/kg)-$0.0108{\times}neutral$ detergent fiber digestibility (NDFD, g/kg). For Sika deer, equation 5 was found to be of the highest accuracy: $CH_4(g/d)=66.3+27.7{\times}DMI(kg/d)-5.91{\times}NDFC(g/kg)-7.11{\times}DMD(g/kg)+0.0809{\times}NDFD(g/kg)$. Conclusion: Digested nutrient intake could be considered when determining the $CH_4$ generation factor in goats and Sika deer. Finally, the enteric $CH_4$ prediction model for goats and Sika deer were estimated.

Numerical Analysis on Performance Improvement for Wind Blade by the Groove (Groove를 활용한 풍력블레이드 성능향상을 위한 수치적 연구)

  • Hong, Cheol-Hyun;Seo, Seong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.475-482
    • /
    • 2011
  • This study, a basic study to improve aerodynamic characteristic of a wind blade, explored through CFD how much the lift to drag ratio improves according to the shape of groove formed on the surface of airfoil NACA0015. This study found out that the ratio improves by 8.7% when the ratio between boundary layer(${\delta}$) and the depth of groove(h), the ratio between the depth of groove(h) and the width of groove(d) and the ratio between the length(p) from one groove to the other and the width of groove are 1.1, 0.1 and 1.2 respectively. The number of grooves is two. It was also confirmed that the improvement of the lift to drag ratio is maintained after certain angle of attack.

Capacity and the moment-curvature relationship of high-strength concrete filled steel tube columns under eccentric loads

  • Lee, Seung-Jo
    • Steel and Composite Structures
    • /
    • v.7 no.2
    • /
    • pp.135-160
    • /
    • 2007
  • Recently, CFT column has been well-studied and reported on, because a CFT column has certain superior structural properties as well as good productivity, execution efficiency, and improved rigidity over existing columns. However, CFT column still has problems clearing the capacity evaluation between its steel tube member and high-strength concrete materials. Also, research on concrete has examined numerical values for high-strength concrete filled steel square tube columns (HCFT) to explain transformation performance (M-${\phi}$) when a short-column receives equal flexure-moment from axial stress. Moment-curvature formulas are proposed for HCFT columns based on analytic assumption described in this paper. This study investigated structural properties (capacity, curvature), through a series of experiments for HCFT with key parameters, such as strength of concrete mixed design (58.8 MPa), width-thickness ratio (D/t), buckling length to sectional width ratio (Lk/D) and concrete types (Zeolite, Fly-ash, Silica-fume) under eccentric loads. A comparative analysis executed for the AISC-LRFD, AIJ and Takanori Sato, etc. Design formulas to estimate the axial load (N)-moment (M)-curvature (${\phi}$) are proposed for HCFT columns based on tests results described in this paper.

An Experimental Study on the Performance Improvement and Emission Reduction in a Turbocharged D.I. Diesel Engine (과급식 디젤엔진의 성능개선 및 배기가스 저감에 관한 실험적 연구)

  • 윤준규;차경옥
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.5
    • /
    • pp.36-46
    • /
    • 2000
  • The performance improvement and emission reduction in a turbocharged D.I. diesel engine was studied experimentally in this paper. The system of intake port, fuel injection and turbochager are very important factors which have influence on the engine performance and exhaust emission because the properties in the injected fuel depend on the combustion characteristics. Through these experiments it can be expected to meet performance and emission by optimizing the main parameters; the swirl ratio of intake port, fuel injection system and turbocharger. The swirl ratio of intake port was modified by hand-working and measured by impulse swirl meter. Through this steady flow test, we knew that the increase of swirl ratio is decreasing the mean flow coefficient, whereas the gulf factor is increasing. And the optimum results of engine performance and emission are as follows; the swirl ratio is 2.43, injection timing is BTDC 13。 CA, compression ratio is 16, combustion bowl is re-entrant 5$^{\circ}$, nozzle hole diameter is $\Phi$0.28*6, turbocharger is GT40 model which are compressor A/R 0.58 AND turbine A/R 1.19.

  • PDF

Effects of Length-to-Diameter Ratio on the Three-Dimensional Flow Within an Injection Hole Normally Oriented to the Mainflow (분사구멍의 길이가 수직 분사구멍 내부에서의 3차원 유동에 미치는 영향)

  • Lee, Sang Woo;Joo, Seong Kuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.9
    • /
    • pp.1255-1266
    • /
    • 1998
  • Effects of a length-to-diameter ratio, L/D, on the three-dimensional flow and aerodynamic loss within an injection hole, which is normally oriented to the mainflow, have been investigated by using a straight five-hole probe. The length-to-diameter ratio of the injection hole is varied to be 0.5 and 2.0 for blowing ratios of 0.5, 1.0 and 2.0. Regardless of the blowing ratio, flows within the hole and at the jet exit are strongly affected by the length-to-diameter ratio. In the case of L/D=0.5, the inside flow is considerably influenced by the mainflow, and the exit flow variation is found to be the greatest. The aerodynamic loss in this case is usually attributed to jet -mainflow interactions. In the case of L/D=2.0, the flow separation and reattachment in the inlet region are completely separated from the complicated exit flow, and the aerodynamic-loss production is mainly due to the inlet flow separation.

Effect of Annealing on c-axis Orientation of $PbTiO_3$ Thin Films by D.C magnetron Reactive Sputtering (D.C Magnetron Reactive Sputtering 법으로 증착한 $PbTiO_3$ 박막의 열처리에 따른 c-축 배향성의 변화)

  • 이승현;권순용;최한메;최시경
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.7
    • /
    • pp.802-808
    • /
    • 1996
  • PbTiO3 thin films were fabricated onto MgO(100) single crystal substrate by reactive D. C magnetron sput-tering of Pb and Ti metal in an oxygen and argon gas mixture. The annealing of the thin films resulted in the decrease of both the c-axis orientation ratio and the lattice parameter. It is well known that the c-axis lattice parameter of thin film is dependent on the Pb/(Pb+Ti)ratio and the residual stress in the film The PbTiO3 thin films with a Pb/(Pb+T) ratio ranging from 0.45 to 0.57 were fabricated and annealed. The structure of the film the c-axis orientation ratio and the lattice parameter were not dependent on the Pb/(Pb+Ti) ratio before and after annealing. These experimental results proved that the decrease of the c-axis lattice parameter under the annealing conditions was due to the relaxation of the intrinsic stress in the film. This relaxation of the intrinsic stress caused the decrease of the c-axis orientation ratio and this phenomenon can be explained by c-axis growth lattice model.

  • PDF

Autonomic Nervous Response of Female College Students with Type D Personality during an Acute Stress Task: Heart Rate Variability (Type D 성격 여대생의 급성 스트레스에 따른 자율신경계 반응 : 심박률 변동성을 중심으로)

  • Ko, Seon-Young;Kim, Myung-Sun
    • Korean Journal of Health Psychology
    • /
    • v.14 no.2
    • /
    • pp.277-292
    • /
    • 2009
  • This study investigated the responses of the autonomic nervous system of individuals with Type D personality during an acute stressful situation. Twenty-three female students of Type D personality and 23 female students with non-Type D personality. Stroop Color-Word Task was used to induce a stressful situation, heart rate variability (HRV) was used to measure the responses of the autonomic nervous system during the baseline, acute stress, recovery periods. To analyze the data, the repeated measures analysis of variance was used to compare the autonomic nervous system of the Type D group to that of the non-Type D group. Regression analysis is used to determine if the Type D scale and stress vulnerability predicted the activities of the autonomic nervous system during the baseline period. The results of this study demonstrated that the Type D group's normalized low frequency (LF norm) and ratio of low frequency to high frequency (LF/HF ratio) were higher than those for the non-Type D group, while its normalized high frequency (HF norm) was lower than that for the non-Type D group in all three periods. There were no statistically significant differences among the three periods in terms of LF norm, HF norm, and LF/HF ratio in the Type D group. The study demonstrated that the total scores of the Type DS-14 and scores of social inhibition and negative affect were independent predictors of LF norm and HF norm during the baseline. The Type D group showed increased activation of the sympathetic nervous system and/or decreased activation of the parasympathetic nervous system. These results support the hypothesis that the Type D personality is vulnerable to the stress. Also, the highly activated sympathetic and/or lowly activated parasympathetic nervous systems, which were observed in the Type D group during the baseline, indicated that the Type D individual is susceptible to psychosomatic disorders.

A Study on Estimation of Forest Burn Severity Using Kompsat-3A Images (Kompsat-3A호 영상을 활용한 산불피해 강도 산정에 관한 연구)

  • Minsun Yang;Min-A Kim
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1299-1308
    • /
    • 2023
  • Forest fires are becoming more frequent and larger around the world due to climate change. Remote sensing such as satellite images can be used as an alternative or assistance data because it reduces various difficulties of field survey. Forest burn severity (differenced normalized burn ratio, dNBR) is calculated through the difference in normalized burn ratio (NBR) before and after a forest fire. The images used in the NBR formula are based on Landsat's near-infrared (NIR) and short-wavelength infrared (SWIR) bands. South Korea's satellite images don't have a SWIR band. So domestic studies related to forest burn severity calculated dNBR using overseas images or indirectly using the normalized difference vegetation index (NDVI) using South Korea's satellite images. Therefore, in this study, dNBR was calculated by substituting the mid-wavelength infrared (MWIR) band of Kompsat-3A (K3A) instead of the SWIR band in the NBR formula. The results were compared with the dNBR results obtained through Landsat which is the standard for dNBR formula. As a result, it was shown that dNBR using K3A's MWIR band has a wider range of values and can be expressed in more detail than dNBR using Landsat's SWIR band. Therefore, it is considered that K3A images will be highly useful in surveying burn areas and severity affected by forest fires. In addition, this study used the K3A's MWIR band images degraded to 30 m. It is considered that much better results will be obtained if a higher-resolution MWIR band is used.